Kenmore 110.8674*, 110.8675*, 110.8676* Owner's Manual

Electric Dryer with SteamCare™

Use & Care Guide

Secadora eléctrica con cuidado con vapor SteamCare™

Manual de uso y cuidado

Models/Modelos 110.8674, 8675, 8676 = color number/número de color

TABLE OF CONTENTS

WARRANTY.....................................................................................2
DRYER SAFETY..............................................................................3
INSTALLATION INSTRUCTIONS ..................................................4
Tools and Parts ............................................................................4
Optional Pedestal .........................................................................5
Location Requirements ...............................................................5
Electrical Requirements................................................................7
Electrical Connection ...................................................................9
Venting Requirements ............................................................... 14
Plan Vent System ...................................................................... 15
Install Vent System.................................................................... 16
Install Leveling Legs .................................................................. 16
Connect Vent............................................................................. 17
Connect Inlet Hoses .................................................................. 17
Level Dryer................................................................................. 17
Reverse Door Swing.................................................................. 18
Complete Installation................................................................. 19
DRYER USE ................................................................................. 20
Starting Your Dryer.................................................................... 20
Stopping Your Dryer.................................................................. 21
Pausing or Restarting................................................................ 21

KENMORE ELITE® APPLIANCE WARRANTY

Control Locked .......................................................................... 22
Drying and Cycle Tips ............................................................... 22
Status Lights.............................................................................. 22
Cycles ........................................................................................ 23
Options ...................................................................................... 24
Modifiers .................................................................................... 25
Changing Cycles, Options, and Modifiers ................................ 25
End of Cycle Signal ................................................................... 25
TUMBLE FREE™ Heated Drying Rack ..................................... 25
DRYER CARE............................................................................... 26
Cleaning the Dryer Location...................................................... 26
Cleaning the Lint Screen ........................................................... 26
Cleaning the Dryer Interior......................................................... 27
Removing Accumulated Lint ..................................................... 27
Water Inlet Hoses ...................................................................... 27
Vacation, Storage, and Moving Care ........................................ 27
Changing the Drum Light .......................................................... 28
TROUBLESHOOTING.................................................................. 28
Dryer Operation ......................................................................... 28
Dryer Results ............................................................................. 29
PROTECTION AGREEMENTS ................................................ 30
SERVICE NUMBERS ...............................................BACK COVER
ONE YEAR LIMITED WARRANTY
When installed, operated and maintained according to all instructions supplied with the product, if this appliance fails due to a defect in material or workmanship within one year from the date of purchase, call 1-800-4-MY-HOME repair.
TWO YEAR LIMITED WARRANTY ON SENSOR SMART™ ELECTRONIC BOARD
For two years from the date of purchase, when this dryer is installed, operated and maintained according to all instructions supplied with the product, Sears will replace the electronic control board if defective in materials or workmanship. After the first year, customer assumes any labor costs associated with replacement of these parts.

If this appliance is used for other than private family purposes, this warranty applies for only 90 days from the date of purchase.

THIS WARRANTY COVERS ONLY DEFECTS IN MATERIAL AND WORKMANSHIP. SEARS WILL NOT PAY FOR:
1. Expendable items that can wear out from normal use,
including but not limited to filters, belts, light bulbs, and bags.
2. A service technician to instruct the user in correct product
installation, operation or maintenance.

3. A service technician to clean or maintain this product.

4. Damage to or failure of this product if it is not installed,
operated or maintained according to all instructions supplied with the product.
5. Damage to or failure of this product resulting from accident,
abuse, misuse or use for other than its intended purpose.
6. Damage to or failure of this product caused by the use of
detergents, cleaners, chemicals or utensils other than those recommended in all instructions supplied with the product.
7. Damage to or failure of parts or systems resulting from
unauthorized modifications made to this product.
®
to arrange for free
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
Customer’s sole and exclusive remedy under this limited warranty shall be product repair as provided herein. Implied warranties, including warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law. Sears shall not be liable for incidental or consequential damages. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, or limitations on the duration of implied warranties of merchantability or fitness, so these exclusions or limitations may not apply to you.

This warranty applies only while this appliance is used in the United States and Canada.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Sears, Roebuck and Co.
Dept. 817WA, Hoffman Estates, IL 60179
Sears Canada Inc.
Toronto, Ontario, Canada M5B 2B8
PRODUCT RECORD

In the space below, record your complete model number, serial number, and purchase date. You can find this information on the model and serial number label located on the product.

Have this information available to help you obtain assistance or service more quickly whenever you contact Sears concerning your appliance.

Model number __ __ __. __________________________________________
Serial number ___________________________________________________
Purchase date___________________________________________________
Save these instructions and your sales receipt for future reference.
2

DRYER SAFETY

Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
follow instructions.
can be killed or seriously injured if you don't
You instructions.
follow
3

INSTALLATION INSTRUCTIONS

Tools a nd Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Flat-blade screwdriver

#2 Phillips screwdriver

Adjustable wrench that
opens to 1" (25 mm) or hex-head socket wrench
adjusting dryer feet)
(for
Wire stripper (for direct wire
installations)

Level

Vent cl amps

Caulking gun and
compound (for installing new exhaust vent)
Tin snips (new vent
installations)
¼" nut driver or socket
wrench (recommended)

Tap e me as u re

Parts supplied

Remove parts package from dryer drum. Check that all parts are included.

A
B
C
A. Leveling legs (4) B. “Y” connector C. Short inlet hose D. Long inlet hose E. Rubber washer
D

NOTE: Do not use leveling legs supplied with dryer if installing on a pedestal.

E
4
Parts needed

Check local codes. Check existing electrical supply and venting. See “Electrical Requirements” and “Venting Requirements” before purchasing parts.

For close-clearance installations between 31.5" (800 mm)
and 37" (940 mm), see “Plan Vent System” section for venting requirements.
37"
(940 mm)
Mobile home installations require metal exhaust system hardware available for purchase from your local Sears store or Se
ars Service Center. For further information, please call
1-800-4-MY-HOME® (1-800-469-4663). If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes
A UL listed 30-amp power supply cord, rated 120/240 volt
dryers. The kit should contain:
minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.

A UL listed strain relief.

Optional Pedestal

Are you placing the dryer on a pedestal? You have the option of purchasing pedestals of different heights separately for this dryer. You may select a 10" (254 mm) pedestal or a 15.5" (394 mm) pedestal with a storage drawer. The pedestal will add to the total height of the dryer for a total height of approximately 46" (1168 mm) or 51.5" (1308 mm), respectively.
For a garage installation, you will need to place the 10" (254 mm) pedestal at least 8" (203 mm) above the floor. You will need to plac
e the 15.5" (394 mm) pedestal at least 3" (76 mm) above the
floor.
Optional pedestal (15.5" [394 mm] model shown)
The pedestals are available in several colors. To order, call your local Sears store. For further information,
se call 1-800-4-MY-HOME
plea
Pedestal Height Color Part Number

10" (254 mm) White 46822

15.5" (394 mm) White 57822

®
(1-800-469-4663).
Location Requirements
You will need
A location that allows for proper exhaust installation. See
“Venting Requirements.”

A separate 30-amp circuit.

If you are using a power supply cord, a grounded electrical
outlet located within 2 ft (610 mm) of either side of the dryer. See “Electrical Requirements.”
A sturdy floor to support the total dryer weight of 200 lbs
(90.7 kg). The combined weight of a companion appliance should also be considered.
Cold water faucets located within 4 ft (1.2 m) of the water fill
valves, and water pressure of 20-100 psi (138-690 kPa). You may use the water supply for your washer using the “Y” connector and short hose (if needed) which are provided.

20-100 psi (138-690 kPa) for best performance.

A level floor with a maximum slope of 1" (25 mm) under entire
dryer. (If slope is greater than 1" [25 mm], install Extended Dryer Feet Kit, Part Number 279810.) Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level.
For a garage installation, you will need to place the dryer at
least 18" (460 mm) above the floor. If you are using a pedestal, you will need 18" (460 mm) to the bottom of the dryer.

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will be exposed to
Check code requirements. Some codes limit, or do not permit, inst
allation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation clearances

The location must be large enough to allow the dryer door to open fully.

water and/or weather.

15.5" (394 mm) Barolo 58829

5
Dryer Dimensions
1
/2"
50
(1283 mm)
38"
(965 mm)
*311/2"
(800 mm)
27"
(686 mm)
*Most installations require a minimum 5" (127 mm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 mm) cle
arance on the sides and rear. Recommended spacing should
be considered for the following reasons:
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

Custom undercounter installation - Dryer only

0"
(0 mm)
38" min.
(965 mm)

Closet installation - Dryer only

14" max.*
(356 mm)
18" min.*
(457 mm)
1
31
/2"
1"*
(25 mm)
(800 mm)
A. Side view - closet or confined area B. Closet door with vents
5"**
(127 mm)
2
*
48 in.
2
(310 cm
)
2
*
24 in.
2
(155 cm
)
3"*
(76 mm)
3"*
(76 mm)
*Required spacing
**For side or bottom venting, 2" (51 mm) spacing is allowed.
Recessed or closet installation
1"*
(25 mm)
27"
(686 mm)
A. Recessed area B. Side view - closet or confined area
- Dryer on pedestal
1"*
(25 mm)
31
(800 mm)
14" max.*
(356 mm)
1
/2"
(127 mm)
5"**
18" min.*
(457 mm)
*Required spacing
**For side or bottom venting, 2" (51 mm) spacing is allowed.

Installation spacing for cabinet installation

For cabinet installation, with a door, minimum ventilation
openings in the top of the cabinet are required.
*Required spacing
6
1"*
(25 mm)
27"
(686 mm)
1"*
(25 mm)
7"*
(178 mm)
5"**
(127 mm)
7"* (178 mm)
1
31
/2"
(800 mm)
1"*
(25 mm)
27"
(686 mm)
(229 mm)
1"*
(25 mm)
*Required spacing
**For side or bottom venting, 2" (51 mm) spacing is allowed.
9"*

Recommended installation spacing for recessed or closet installation, with stacked washer and dryer

The dimensions shown are for the recommended spacing.
2
*
48 in.
2
(310 cm
)
2
*
24 in.
2
(155 cm
)
3"*
(76 mm)
3"*
(76 mm)
1"*
(25 mm)
*Required spacing
6"* (152 mm)
76"
(1930 mm)
1
5
/2"
(140 mm)
1"*
(25 mm)
27"
(686 mm)
1"*
(25 mm)
*Required spacing
or venting out the side, 2" (51 mm) spacing is allowed.
**F
Mobile home - additional installation requirements
This dryer is suitable for mobile home installations. The installation must conform to Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).
Mobile home installations require:
Metal exhaust system hardware, which is available for
purchase from your local Sears store or Sears Service Center.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
the Manufactured Home

Electrical Requirements

It is your responsibility

To contact a qualified electrical installer.

To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire supply
nection for homes built after 1996, dryer circuits involved
con in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from: Na
tional Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt el
ectrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

Do not use an extension cord.

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the ground path is adequate.
Electrical Connection

To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

If local codes do not permit the connection of a neutral
ground wire to the neutral wire, see “Optional 3-wire connection” in the “Electrical Connection” section.
This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The neutral ground wire is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the external ground conductor screw (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground wire is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.
A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.
7
If using a power supply cord:

Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:

A UL listed 30-amp power supply cord, rated
120/240 volt minimum. The cord should be type SRD
or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the
dryer must end in ring terminals or spade
terminals with upturned ends.

A UL listed strain relief.

If your outlet looks like this:

4-wire receptacle (14-30R)

Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.
If your outlet looks like this:

At least 5 ft (1.52 m) long.

3-wire receptacle (10-30R)

Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.

If connecting by direct wire:
Power supply cable must match p
ower supply (4-wire or 3-wire)
and be:
Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.

10-gauge solid copper wire (do not use aluminum).

8

Electrical Connection

Power Supply Cord

WARNING
Fire Hazard Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief. Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center
terminal (silver). Ground wire (green or bare wire) must be connected to
green ground connector. Connect remaining 2 supply wires to remaining
2 terminals (gold). Securely tighten all electrical connections. Failure to do so can result in death, re, or
electrical shock.

Direct Wire

WARNING
Fire Hazard Use 10 gauge solid copper wire. Use a UL listed strain relief. Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections. Failure to do so can result in death, re, or
electrical shock.

1. Disconnect power.

move the hold-down screw and terminal block cover.
2. Re
C
B
A
A. Neutral ground wire
B. External ground conductor scr C. Center, silver-colored ter D. Terminal block cover and hold-down screw

3. Install strain relief.

ew
minal block screw

Style 1: Power supply cord strain relief

Remove the screws from a
relief (UL marking on strain relief). Put the tabs of the two clamp sections into the hole below the terminal block opening so that one tab is pointing up and the other is
D
pointing down, and hold in place. Tighten strain relief screws enough to hold the two clamp sections together.
A. Strain relief tab pointing up B. Hole below terminal block opening C. Clamp section D. Strain relief tab pointing down
3
/4" (19 mm) UL listed strain
A
B
C
D
9
Put power supply cord through the strain relief. Be sure
A
that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.
Electrical Connection Options
If your home has: And you will be
connecting to:
4-wire receptacle (NEMA Type 14-30R)
A UL listed, 120/240-volt minimum
, 30-amp, dryer power supply cord*
Go to Section
4-wire connection: Power supply cord

Style 2: Direct wire strain relief

Unscrew the removable conduit connector and any
screws from a
3
/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief through the hole below the terminal block opening. Reaching inside the terminal block opening, screw the removable conduit connector onto the strain relief threads.
A
B
C
4-wire direct
A fused disconnect or
4-wire connection: Direct Wire
circuit breaker
5"
(127 mm)
3-wire receptacle (NEMA type 10-30R)
box*
A UL listed, 120/240-volt minimum
,
3-wire connection: Power supply cord
30-amp, dryer power supply cor
d*
3-wire direct
A fused disconnect or
3-wire connection: Direct Wire
circuit breaker
3½"
(89 mm)
box*
*If local codes do not permit the connection of a cabinet-ground
condu
ctor to the neutral wire, go to “Optional 3-wire
connection” section.
4-wire connection: Power supply cord
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire connections.
BF
A. Removable conduit connector B. Hole below terminal block opening C. Strain relief threads
Put direct wire cable through the strain relief. The strain
relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.
4. Now complete installation following instructions for your type
of electrical connection: 4-wire (recommended)
(if 4-wire is not available)
3-wire
C
D
A. 4-wire receptacle (NEMA type 14-30R) B. 4-prong plug C. Ground prong D. Neutral prong E. Spade terminals with upturned ends
F. ¾" (19 mm) UL listed strain relief
G. Ring terminals
E
1. Remove center, silver-colored terminal block screw.
G
10
2. Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center, silver-colored terminal block screw. Tighten screw.
A
C
B
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center, silver-colored terminal block screw. B. Center, silver-colored terminal block screw C. Neutral ground wire D. Neutral wire (white or center wire) E. ¾" (19 mm) UL listed strain relief
D
E
3. Connect ground wire (green or bare) of power supply cord to
external ground conductor screw. Tighten screw.
A
D
4-wire connection: Direct wire
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be m
Strip 5" (127 mm) of outer covering fr bare ground wire at 5" (127 mm). Cut 1
oved if needed.
om end of cable, leaving
1
/2" (38 mm) from
3 remaining wires. Strip insulation back 1" (25 mm). Shape ends
wires into a hook shape.
of
1"
(25 mm)
5"
(127 mm)
When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.
B
C
A. External ground conductor screw B. Ground wire (green or bar C. ¾" (19 mm) UL listed strain relief D. Center, silver-colored terminal block screw
E. Neutral ground wire
F. Neutral wire (white or
e) of power supply cord
center wire)
E
F
4. Connect the other wires to outer terminal block screws.
Tighten screws.

5. Tighten strain relief screws.

6. Insert
tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. Y
ou have completed your electrical connection. Now go to
“Venting Requirements.”
1. Remove center, silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the terminal block. Squeeze hooked ends together. Tighten screw.
A
C
B
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center, silver-colored terminal block screw. B. Center, silver-colored terminal block screw C. Neutral ground wire D. Neutral wire (white or E. ¾" (19 mm) UL listed strain relief
center wire)
D
E
11
3. Connect ground wire (green or bare) of direct wire cable to
A
A
external ground conductor screw. Tighten screw.
A
D
2. Connect neutral wire (white or center wire) of power supply
cord to the center, silver-colored terminal screw of the terminal block. Tighten screw.
C
B
C
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cable C. ¾" (19 mm) UL listed strain relief D. Center silver-colored ter
E. Neutral ground wire
F. Neutral wire (white or
minal block screw
center wire)
E
F
4. Place the hooked ends of the other direct wire cable wires
under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
B
A. External ground conductor screw B. Neutral ground wire C. Center, silver-colored terminal block screw D. Neutral wire (white E. ¾" (19 mm) UL listed strain relief
or center wire)
D
E
3. Connect the other wires to outer terminal block screws.
Tighten screws.

5. Tighten strain relief screw.

6. Insert
tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
ou have completed your electrical connection. Now go to
7. Y
“Venting Requirements.”
3-wire connection: Power supply cord

4. Tighten strain relief screws.

5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go to
“Venting Requirements.”
3-wire connection: Direct wire
Use where local codes permit connecting cabinet-ground
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
B
D
E
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be m
Strip 3
oved if needed.
1
/2" (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of wires
C
A. 3-wire receptacle (NEMA type 10-30R) B. 3-wire plug C. Neutral prong D. Spade terminals with up turned ends E. ¾" (19 mm) UL listed strain r
F. R i ng te r mi n a l s
G. Neutral (white or center wire)
1. Loosen or remove center, silver-colored terminal block screw.
elief
F
G
into a hook shape.
1"
(25 mm)
3½"
(89 mm)
12
When connecting to the terminal block, place the hooked end of
A
the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.
2. Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord/cable under center, silver-colored terminal block screw. Tighten screw.
1. Loosen or remove center, silver-colored terminal block screw.
2. Place the hooked end of the neutral wire (white or center wire)
of direct wire cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.
C
B
A. External ground conductor screw B. Neutral ground wire C. Center, silver-colored ter D. Neutral wire (white or
E. ¾" (19 mm) UL listed strain relief
minal block screw
center wire)
D
E
A
A. External ground conductor screw
B. Center, silver-colored ter C. Neutral ground wire D. Neutral wire (white or center wire)
E. ¾" (19 mm) UL listed strain relief
F. Grounding path determined by
minal block screw
a qualified electrician
3. Connect the other wires to outer terminal block screws.
Tighten screws.
B
C
D
E
F
3. Place the hooked ends of the other direct wire cable wires
under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.

4. Tighten strain relief screw.

5. Insert
tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. Y
ou have completed your electrical connection. Now go to
“Venting Requirements.”
Optional 3-wire connection
Use for direct wire or power supply cord where local codes do not permit connecting cabinet-ground conductor to neutral wire.
1. Remov
e center, silver-colored terminal block screw.

4. Tighten strain relief screws.

5. Connect a separate
copper ground wire from the external
ground conductor screw to an adequate ground.
6. Insert tab of
terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
13
Venting Requirements
WARNING
Fire Hazard Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death
or re.
Flexible metal vent must be fully extended and supported
when the dryer is in its final location.
Remove excess flexible metal vent to avoid sagging and
kinking that may result in reduced airflow and poor performance.
Do not install flexible metal vent in enclosed walls, ceilings,
or floors.
The total length of flexible metal vent should not exceed
7¾ ft (2.4 m).
Elbows
45° elbows provide better airflow than 90° elbows.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS. IMPORTANT: O The dryer exhaust must not be connected into any gas vent,
himney, wall, ceiling, attic, crawlspace, or a concealed space of
c a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid heavy metal
vent or flexible metal vent.
Review Vent system chart. Modify existing vent system if
necessary to achieve the best drying performance. Only rigid or flexible metal vent shall be used for exhausting.
If this is a new vent system
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (102 mm) heavy metal exhaust vent and clamps must be
used. DURASAFE™ venting products are recommended.
bserve all governing codes and ordinances.
Good Better
Clamps
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into the interior of the vent and catch lint. Do not use duct tape.
Clamp
Exhaust
Recommended hood styles are shown here.
B
A
4" (102 mm)
4" (102 mm)
A. Louvered hood style
B. Box hood style
4" (102 mm) heavy metal exhaust vent
DURASAFE™ vent products can be purchased from your dealer. For further information, please call
1-800-4-MY-HOME
®
(1-800-469-4663) or visit our website at
www.sears.com or www.sears.ca.
Rigid metal vent
For best drying performance, rigid metal vents are
recommended.
Rigid metal vent is recommended to avoid crushing and
kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for
cleaning.
14
The angled hood style (shown here) is acceptable.
4"
(102 mm)
An exhaust hood should cap the vent to keep rodents and
C
2½"
(64 mm)
insects from entering the home.
Exhaust hood must be at least 12" (305 mm) from the ground
or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).
Do not use an exhaust hood with a magnetic latch.
A
Improper venting can cause moisture and lint to collect indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.
Housecleaning problems and health problems.
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer. Other installations are possible.
B
C
D
E
Optional exhaust installations
This dryer can be converted to exhaust out the right side, left side, or through the bottom. dryer converted.
Contact your local dealer to have the
WARNING
Fire Hazard
Cover unused exhaust holes with one of the following kits:
279818 (white)
280189 (barolo)
Contact your local dealer.
Failure to follow these instructions can result in death, fire, electrical shock, or serious injury.
A. Dryer B. Elbow C. Wall D. Exhaust hood
F
G
H
E. Clamps
F. Rigid metal or flexible metal vent
G. Vent length necessar
elbows
H. Exhaust outlet
y to connect
A B C
A. Standard rear offset exhaust installation B. Left or right side exhaust installati C. Bottom exhaust installation (not an option
with pedesta
l installations)
on
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.
A B
A. Over-the-top installation (also available with one offset elbow) B. Periscope installation
15
NOTE: The following kits for close clearance alternate
installations are available for purchase. For further information, please call 1-800-4-MY-HOME® (1-800-469-4663).
Over-the-Top Installation:
Part Number 26-49900
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 26-49901 - Less than 5" (127 mm) mismatch
Part Number 26-49908 - 5" (127 mm) to 18" (457 mm)
atch
mism
Part Number 26-49904 - 18" (457 mm) to 29" (737 mm) mismatch
Part Number 26-49905 - 29" (737 mm) to 50" (1270 mm) mismatch
Vent system chart
NOTE: Side and bottom exhaust installations have a 90º turn
inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.
Number of 90º turns or elbows

0 Rigid metal 64 ft (20 m) 58 ft (17.7 m)

1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m)

2 Rigid metal 44 ft (13.4 m) 38 ft (11.6 m)

3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m)

4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m)

Type of vent
Box or Louvered hoods
Angled hoods
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path
Select the route that will provide the straightest and most
direct path outdoors.
Plan the installation to use the fewest number of elbows and
turns.
When using elbows or making turns, allow as much room as
possible.
Bend vent gradually to avoid kinking.
Use the fewest 90° turns possible.
Install Vent System
1. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2. Conn
3. Run vent to dryer location. Use the straightest path possible.
ect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (102 mm) clamp.
See “Determine vent path” in “Plan Vent System.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into the interior of the vent to secure vent, which can catch lint.
Install Leveling Legs
WARNING
Excessive Weight Hazard Use two or more people to move and install dryer. Failure to do so can result in back or other injury.
1. To avoid damaging the floor, use a large flat piece of
cardboard from the dryer carton. Place cardboard under the entire back edge of the dryer.
2. Firmly grasp
Gently lay the dryer on the cardboard. See illustration.
the body of the dryer (not the console panel).
Determine vent length and elbows needed for best drying performance
Use the following Vent system chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in
the Vent system chart. Exhaust systems longer than those specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent system chart provides venting requirements that will
lp to achieve the best drying performance.
he
16

3. Examine the leveling legs. Find the diamond marking.

4. Screw the legs into the leg holes by hand. Use a wrench to
finish turning the legs until the diamond marking is no longer visible.
5. Place a carton corner post from dryer packaging under each
of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent.
Connect Vent
1. Using a 4" (102 mm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a 4" (102 mm) clamp.
2. Move dryer
3. Once the exhaust vent connection is made, remove the
corner posts and cardboard.
into its final location. Do not crush or kink vent.
8. Usin
g pliers, tighten the couplings with an additional
two-thirds turn.
A
A. Inlet to cold water
Connect Inlet Hoses
The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use old hoses.
urn cold water faucet off and remove washer inlet hose.
1. T
emove old rubber washer from inlet hose and replace with
2. R
new rubber washer provided. If space permits, attach the brass female end of the “Y” connector to the cold water faucet.
NOTE: If faucet, go to Step 6. If “Y” connector cannot be attached directly to the cold water faucet, the short hose must be used. Continue with Step 3.
3. Attach short hose to cold water faucet. Screw on coupling by
hand until it is seated on faucet.
4. Using pliers, tighten the couplings with an additional two-
thirds turn.
NOTE: Do n result.
5. Atta
on coupling by hand until it is seated on connector.
6. One en
coupling. Attach this end to the “Y” connector.
7. Atta
Screw on coupling by hand until it is seated on connector.
“Y” connector can be attached directly to cold water
ot overtighten. Damage to the coupling can
ch “Y” connector to brass male end of small hose. Screw
d of the long hose has a wire mesh strainer inside the
ch washer cold inlet hose to other end of “Y” connector.
NOTE: Do not overtighten. Damage to the coupling can result.
9. Attach other end of long hose to fill valve at bottom of dryer
back panel. Screw on coupling by hand until it is seated on fill valve connector.
10. Usin

11. Check that the water faucets are on.

12. Che
g pliers, tighten the coupling with an additional two-
thirds turn.
NOTE: Do not overtighten. Damage to the coupling can result.
ck for leaks around “Y” connector, faucet, and hoses.
Level Dryer
Check the levelness of the dryer. Check levelness first side to side, then front to back.
If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs up or down and check again for levelness.
17
Reverse Door Swing
A
A
You can change your door swing from a right-side opening to a left-side opening, if desired.
For ease of installation, you may want to use 2 or more
NOTE: people to remove and reattach the dryer door.
Remove the door
1. Place a towel or soft cloth on top of the dryer or work space
to avoid damaging the surface.
2. Ope
n the dryer door. Remove the 5 screws that hold the door
hinge on the front panel of the dryer.
2. Remove
the 4 hinge screws that hold the hinge to the door
and remove hinge.
B
C
C
B
C
A. Dryer front panel B. Dryer door
C. Screws

3. Remove the door.

4. Lay the dryer door on a flat, protected surface with the inside
door assembly facing up. Remove the 5 screws to release the outer door assembly
from the inner door assembly, as indicated below. See illustration. It is important that you remove only the 5 indicated screws.
A
A. Hinge side screw B. Locator pins on hinge C. Top side screw
B
3. Move the large hole screw to the opposite side. Remove the
2 plug screws and plastic plugs, and insert
them in the
original screw holes on the opposite side.
A
A. Hinge screws B. Large hole screw C. Plug screws and plastic plugs
B
C
4. Move hinge to the other side and reattach with the 4 screws
removed in Step 2. Make sure locator pins line up in holes and drive the top 2 screws in place first to help drive locator pins into proper location.
et the inner door assembly aside.
5. S
5. Lift the inner door assembly off of the outer door assembly.
Set the outer door assembly aside.
Reverse the hinge
1. Place the inner door, screw head side up, on the work space.
Reverse the door handle
1. Place the outer door assembly face down on work space.
2. Remove the 6 screws that hold the intermediate door to the
outer door assembly. Remove the intermediate door, and set hinge shield aside. Remove the hinge hole cover.
B
A
A. Intermediate door
B. Hinge shield
C. Hinge hole cover
C
18
3. Rotate the window assembly 180º and reattach the
A
intermediate door, hinge shield, and hinge hole cover with the 6 screws removed in Step 2.
Reinstalling the door
1. Place the inner door assembly into the outer door assembly.
To fit correctly, the inside door assembly edge is completely inside the outside door assembly edge.
2. Re
assemble the inner and outer door assemblies with the
5 screws.
3. Remove existing label from the opposite side of the door and
discard. Find label provided with the Use and Care Guide and apply over original hinge holes.
4. Align the door by placing the locating tabs on the hinge with
the locating holes on the dryer front panel. Insert and tighten the center hinge screw. The door will hang in place while you insert and tighten the remaining 4 screws.
NOTE: T dryer door.
wo or more people may be needed to reattach the
B
C
Complete Installation
1. Check that all parts are now installed. If there is an extra part,
go back through the steps to see which step was skipped.
heck that you have all of your tools.
2. C
spose of/recycle all packaging materials.
3. Di

4. Be sure the water faucets are on.

5. Che
6. Check
7. Che
8. For
9. Re
10. R
11. Wipe
12. If you live in
13. Sel
This dryer automatically runs an installat the start of its first cycle.

If you receive an L2 code, there may be a problem with your home power supply keeping the dryer’s heater from turning on. See “Troubleshooting.”

If you receive an AF code, your dry blocked. See “Troubleshooting.”
NOTE:
This odor is common when the heating element is first used. The odor will go away.
ck for leaks around “Y” connector, faucet, and hoses.
the dryer’s final location. Be sure the vent is not
crushed or kinked.
ck that the dryer is level. See “Level Dryer.” power supply cord installation, plug into an outlet. For
direct wire installation, reconnect power.
move the blue film on the console and any tape remaining
on the dryer.
ead “Dryer Use.”
the dryer drum interior thoroughly with a damp cloth to
remove any dust.
a hard water area, use of a water softener is recommended to control the buildup of scale through the water system in the dryer. Over time, the buildup of lime scale may clog different parts of the water system, which will reduce product performance. Excessive scale buildup may lead to the need for certain part replacement or repair.
ect a Timed Dry heated cycle, and start the dryer. Do not
select the Air Only Temperature setting.
If the dryer will not start, check the following:

Controls are set in a running or “On” position.

Start button has been pushed firmly.

Dryer is plugged into an outlet and/or electrical supply
is connected.
Household fuse is intact and tight, or circuit breaker has
not tripped.

Dryer door is closed.

ion diagnostic routine at
er vent may be crushed or
You may notice an odor when the dryer is first heated.
A. Dryer door B. Dryer front panel C. Insert this hinge screw first.

5. Close the door and check that it latches securely.

6. Check
for fingerprints on the glass. Clean the glass if
necessary.
19

DRYER USE

Starting Your Dryer

WARNING
Explosion Hazard
Keep ammable materials and vapors, such as gasoline, away from dryer.
Do not dry anything that has ever had anything ammable on it (even after washing).
Failure to follow these instructions can result in death, explosion, or re.
WARNING: To reduce the risk of fire, electric shock, or injury to
persons, read the IMPORTANT SAFETY INSTRUCTIONS before operating this appliance.
Follow these basic steps to start your dryer. Please refer to
fic sections of this manual for more detailed information.
speci
1. Cle
an lint screen before each load. See “Cleaning the Lint
Screen.”
2. Place laundry in dr
ess the POWER button. Then rotate the dial to select the
3. Pr
desired Auto or SteamCare Cycle. Press button on left of dial to select the desired Timed Cycle. The indicator light for the selected Auto or Timed Cycle will glow green. The indicator light for the selected SteamCare Cycle will glow blue. The preset modifiers for the selected cycle will glow green. Selectable options will glow amber. If an option or modifier is unavailable with the selected cycle, the light will not illuminate. The estimated or actual cycle time (in minutes) will show in the display.
yer and shut door.
WARNING
Fire Hazard No washer can completely remove oil. Do not dry anything that has ever had any type of oil on
it (including cooking oils). Items containing foam, rubber, or plastic must be dried
on a clothesline or by using an Air Cycle. Failure to follow these instructions can result in death
or re.
To use an Auto Cycle NOTE: A li
feature is selected or will glow amber when the feature is selectable.

Select an Auto Cycle.

Select DRYNESS LEVEL to adjust how dry you want the

Select the desired Options.

ght next to each feature will glow green when the
load. As the cycle runs, the control senses the dryness of the load and adjusts the time automatically for the selected dryness level.
NOTE: Most loads may be dried using the Normal dryness level, which is shown in bold letters on your control panel. Normal is the energy preferred dryness level and will use the least energy.
20
Loading...
+ 44 hidden pages