Electric Dryer
Secadora El_ctrica
Models/Modelos 110.8656=_, 8657_
#: = color number/nemero de color
®
iiiiii!Jiiiiiiiiiii!il
8572743 Sears Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com
TABLEOF CONTENTS
PROTECTION AGREEMENTS
PROTECTION AGREEMENTS ....................................................... 2
WARRANTY ..................................................................................... 3
PEDESTAL OPTION WARRANTY ................................................. 3
DRYER SAFETY .............................................................................. 4
INSTALLATION INSTRUCTIONS .................................................. 5
Tools and Parts ............................................................................ 5
Options ......................................................................................... 5
Location Requirements ............................................................... 5
Electrical Requirements ................................................................ 8
Electrical Connection ................................................................... 9
Venting Requirements ............................................................... 14
Plan Vent System ...................................................................... 15
Install Vent System .................................................................... 16
Install Leveling Legs .................................................................. 17
Connect Vent ............................................................................. 17
Level Dryer ................................................................................. 17
Reverse Door Swing .................................................................. 17
Complete Installation ................................................................. 19
DRYER USE ................................................................................. 20
Starting Your Dryer .................................................................... 20
Stopping or Restarting Your Dryer............................................ 21
Lock Controls ............................................................................ 21
Loading Guide ........................................................................... 21
Drying and Cycle Tips ............................................................... 22
Status Lights .............................................................................. 22
Cycles ........................................................................................ 23
Modifiers .................................................................................... 24
Options ...................................................................................... 24
Changing Cycles, Options and Modifiers ................................. 24
TUMBLE FREETM Non-Heated Dryer Rack .............................. 25
DRYER CARE .............................................................................. 26
Cleaning the Dryer Location ...................................................... 26
Cleaning the Lint Screen ........................................................... 26
Cleaning the Dryer Interior ........................................................ 26
Removing Accumulated Lint ..................................................... 27
Vacation and Moving Care ........................................................ 27
TROUBLESHOOTING .................................................................. 28
SERVICE NUMBERS ............................................... BACK COVER
Master Protection Agreements
Congratulations on making a smart purchase. Your new
Kenmore ®product is designed and manufactured for years of
dependable operation. But like all products, it may require
preventive maintenance or repair from time to time. That's when
having a Master Protection Agreement can save you money and
aggravation.
Purchase a Master Protection Agreement now and protect
yourself from unexpected hassle and expense.
The Master Protection Agreement also helps extend the life of
your new product. Here's what's included in the Agreement:
v' Expert service by our 12,000 professional repair specialists
v' Unlimited service and no charge for parts and labor on all
covered repairs
v' "No-lemon" guarantee - replacement of your covered
product if four or more product failures occur within twelve
months
v' Product replacement if your covered product can't be fixed
v' Annual Preventive Maintenance Check at your request - no
extra charge
v' Fast help by phone - phone support from a Sears technician
on products requiring in-home repair, plus convenient repair
scheduling
v' Power surge protection against electrical damage due to
power fluctuations
v' Rental reimbursement if repair of your covered product takes
longer than promised
Once you purchase the Agreement, a simple phone call is all that
it takes for you to schedule service. You can call anytime day or
night, or schedule a service appointment online.
Sears has over 12,000 professional repair specialists, who have
access to over 4.5 million quality parts and accessories. That's
the kind of professionalism you can count on to help prolong the
life of your new purchase for years to come. Purchase your
Master Protection Agreement today!
Some limitations and exclusions apply. For prices and
additional information, call 1-800-827-6655.
Sears Installation Service
For Sears professional installation of home appliances, garage
door openers, water heaters, and other major home items, in the
U.S.A. call 1-800-4-MY-HOME ®.
WARRANTY
PEDESTAL OPTION
ONE YEAR FULL WARRANTY ON HE2 DRYER
For one year from the date of purchase, when installed and
operated according to the Use & Care Guide, this dryer will be
repaired free of charge if defective in material or workmanship.
Warranty Restriction
If this dryer is used for other than private family purposes, this
warranty applies for only 90 days from the date of purchase.
Exhausting this dryer with a plastic or metal foil vent will void this
warranty.
Warranty Service
Warranty service is available by calling 1-800-4-MY-HOME ®,This
warranty applies only while this dryer is used inthe United States.
This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state.
Sears, Roebuck and Co.
D/817WA, Hoffman Estates, IL 60179
Product Record
In the space following, record your complete model number,
serial number, and purchase date. You can find this information
on the model and serial number label, located at the top inside
dryer door well.
Have this information available to help you quickly obtain
assistance or service when you contact Sears concerning your
appliance.
Model number 110.
Serial number
Purchase date
Save these instructions and your sales receipt for future
reference.
WARRANTY
One Year Full Warranty on Pedestal
For one year from the date of purchase, when installed according
to its Installation Instructions, this pedestal will be repaired or
replaced free of charge if it is defective in material or
workmanship.
Warranty Restriction
This warranty is void if this pedestal is used for other than private
family purposes, or used with any other product than those listed
in its Installation Instructions.
Warranty Service
Warranty service is available by calling 1-800-4-MY-HOME ®.This
warranty applies only while this pedestal is used in the United
States or Canada. This warranty gives you specific legal rights,
and you may also have other rights which vary from state to
state.
In the space following, record your complete model number,
serial number, and purchase date. You can find this information
on the model and serial number label.
Have this information available to help you quickly obtain
assistance or service when you contact Sears concerning your
appliance.
Model number 110.
Serial number
Purchase date
Save these instructions and your sales receipt for future
reference.
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
iMPORTANT SAFETY iNSTRUCTiONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
m Read all instructions before using the dryer.
m Do not ptace items exposed to cooking oiIs in your dryer.
items contaminated with cooking oils may contribute to
a chemicat reaction that could cause a load to catch fire.
m Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, dry-
cleaning solvents, or other flammable or explosive
substances as they give off vapors that could ignite or
explode.
m Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is
used near children.
m Before the dryer is removed from service or discarded,
remove the door to the drying compartment.
m Do not reach into the dryer if the drum is moving.
m Do not install or store the dryer where it will be exposed
to the weather.
m Do not tamper with controls.
SAVE THESE INSTRUCTIONS
m Do not repair or replace any part of the dryer or attempt
any servicing unless specifically recommended in this
Use and Care Guide or in published user-repair
instructions that you understand and have the skills to
carry out.
m Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric
softener or product.
m Do not use heat to dry articles containing foam rubber or
similariy textured rubber-like materials.
,, Clean lint screen before or after each load.
m Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust,
and dirt.
The interior of the dryer and exhaust vent should be
cleaned periodicaily by qualified service personnel.
See installation instructions for grounding requirements.
INSTALLATION INSTRUCTIONS
Gather the required tools and parts before starting installation.
Read and follow the safety instructions provided with any tools
listed here.
• Flat-blade screwdriver • Vent clamps
• #2 Phillips screwdriver • Caulking gun and
• Adjustable wrench that
opens to 1" (2.54 cm) or new exhaust vent)
hex-head socket wrench • Tin snips (new vent
(for adjusting dryer feet) installations)
• Wire stripper (direct wire • 1A"nut driver or socket
installations) wrench (recommended)
• Level • Tape measure
Parts supplied
Remove parts package from dryer drum. Check that all parts are
included.
4Leveling legs
NOTE: Do not use leveling legs if installing the dryer on a
pedestal.
Parts needed
Check local codes. Check existing electrical supply and venting.
See "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
• For close-clearance installations between 28.65" (72.77 cm)
and 34.15" (86.74 cm), see "Plan Vent System" section for
venting requirements.
compound (for installing
Pedestal
Are you placing the dryer on a pedestal? You can purchase a
pedestal separately for this dryer. This pedestal will add about
10" (25.4 cm) to the height of your unit for a total height of
approximately 46" (116.8 cm).
For a garage installation, you will need to place the dryer at least
18" (46 cm) above the floor.
Optional pedestal
The pedestal is available in:
White - Part Number 46822
To order, call your local Sears store. For further information,
please call 1-80O-4-MY-HOME ®(1-800-469-4663).
ackK.
Are you planning to stack your Kenmore washer and dryer? Todo
so, find the stack kit in the dryer drum. Follow instructions
included with the kit. See "Location Requirements."
(86.74 cm)
Mobile home installations require metal exhaust system hardware
available for purchase from your local Sears store or Sears
Service Center. For further information, please call
1-80O-4-MY-HOME ®(1-800-469-4663).
Exp(os(on Hazard
Keep flammable mateda(s and vapors, such as
gasoUne, away from dryer.
P_ace dryer at (east 18 (riches (48 cm) above the floor
for a garage installation.
Fai(ure to do so can result in death, explosion, or fire°
You will need
• A location that allows for proper exhaust installation. See
"Venting Requirements."
• A separate 30-amp circuit.
• If using a power supply cord, a grounded electrical outlet
located within 2 ft (61 cm) of either side of the dryer. See
"Electrical Requirements."
• A sturdy floor to support the total dryer weight of 127 Ibs
(57.6 kg). The combined weight of a companion appliance
should also be considered.
Alevelfloorwithamaximumslopeof1"(2.5cm)underentire
dryer.(Ifslopeisgreaterthan1"[2.5cm],installExtended
DryerFeetKit,PartNo.279810.)Clothesmaynottumble
properlyandautomaticsensorcyclesmaynotoperate
correctlyifdryerisnotlevel.
• Foragarageinstallation,youwillneedtoplacethedryerat
least18"(46cm)abovethefloor.Ifusingapedestal,youwill
need18"(46cm)tothebottomofthedryer.
Donotoperateyourdryerattemperaturesbelow45°F(7°C).At
lowertemperatures,thedryermightnotshutoffattheendofan
automaticcycle.Dryingtimescanbeextended.
Thedryermustnotbeinstalledorstoredinanareawhereitwill
beexposedtowaterand/orweather.
Checkcoderequirements.Somecodeslimit,ordonotpermit,
installationofthedryeringarages,closets,mobilehomesor
sleepingquarters.Contactyourlocalbuildinginspector.
Installation clearances
The location must be large enoughto allow the dryer door to
open fully.
Dryer Dimensions
36" I
{91=4cm)
Custom undercounter installation - Dryer only
(5cm) t
36"rain I I II
1"* _ _ 27"-----_--- 1"*
2=5¢m 68=6¢m {2=5cm)
*Additional spacing recommended
Closet installation - Dryer only
II "1111_1111 I I 24in? _
LCI I LI ,,0,oro2,
11"t<-28,65"_"10"*I
{2=5cm} (72=77¢m} (0¢m)
A B
A. Side view - closet or confined area
B. Closet door with vents
*Side or bottom venting - additional
spacing recommended
(7=6cm)
'2&65"
(72=77cm)
*Most installations require a minimum 51/2'' (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum installation spacing for recessed area, custom
undercounter or closet installation
The following dimensions shown are for the minimum spacing
allowed.
• Additional spacing should be considered for ease of
installation and servicing.
• Additional clearances might be required for wall, door and
floor moldings.
• Additional spacing of 1" (2.5 cm) on all sides of the dryer is
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
• Companion appliance spacing should also be considered.
Recessed or closet installation - Dryer on pedestal
(0ore}
,,F- 27"---_1"-0"* Irl* 28=65"_'10....
(68.6cm) (0cm) (2.5cm) _'2.77cm} (0cm)
A B
A. Recessed area
B. Side view - closet or confined area
*Additional spacing recommended
**Side or bottom venting - additional
spacing recommended
Minimum installation spacing for cabinet installation
• The dimensions shown are for the minimum spacing allowed.
• For cabinet installation, with a door, minimum ventilation
openings in the top of the cabinet are required.
" , )
7"(17.8crn)
a!
_;'29 crn)
0 !* 2865 0 * 27 0 *
(0cm) (72.77cm)(2.5cm) (0cm)(68.6cm)(0cm)
*Additional spacing recommended
**Side or bottom venting - additional
spacing recommended
Recommended installation spacing for recessed or
closet installation, with stacked washer and dryer
The dimensions shown are for the recommended spacing.
48 in=_*
{310 ¢m _}
3"(7,_cm)
6" {_m)
72"
(182.9 cm)
5Y2"** ==}1_
14 cm
1"*** -_
{2=5cm)
_-27"=;_ _ I "***
68=6cm 2=5cm
**External exhaust elbow requires additional space.
***Wall, door and floor molding may require
additional spacing.
Mobile home - additional installation requirements
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280).
Mobile home installations require:
• Metal exhaust system hardware, which is available for
purchase from your local Sears store or Sears Service Center.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
3" (7=6cm)
24 in=_*
-m_ _,_ 1" (2.5cm)
(155cm_)
•Min. top and bottom air openingsfor closet doo_
It is your responsibility
• Tocontact a qualified electrical installer.
• To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSl/NFPA
70-latest edition and all local codes and ordinances.
The National Electric Code requires a 4-wire supply
connection for homes built after 1996, dryer circuits involved
in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.
Tosupply the required 3 or 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt
electrical supply, if specified on the serial/rating plate) on a
separate 30-amp circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended. Connect
to an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
• Do not use an extension cord.
• Ifcodes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
• This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The neutral ground wire is
permanently connected to the neutral conductor (white wire)
within the dryer. If the dryer is installed with a 4-wire electrical
supply connection, the neutral ground wire must be removed
from the external ground conductor screw (green screw), and
secured under the neutral terminal (center or white wire) of
the terminal block. When the neutral ground wire is secured
under the neutral terminal (center or white wire) of the
terminal block, the dryer cabinet is isolated from the neutral
conductor.
• Iflocal codes do not permit the connection of a neutral
ground wire to the neutral wire, see "Optional 3-wire
connection" section.
A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through
the neutral conductor is prohibited. Grounding through the
neutral is prohibited for (1) new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and (4) areas
where local codes prohibit grounding through the neutral
conductors.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
• A UL listed 30-amp power supply cord, rated
120/240 volt minimum. The cord should be type SRD or
SRDT and be at least 4 ft (1.22 m) long. The wires that
connect to the dryer must end in ring terminals or spade
terminals with upturned ends.
• A UL listed strain relief.
If your outlet looks like this:
4-wire receptacle (14-30R)
Then choose a 4-wire power supply cord with ring or spade
terminals and UL listed strain relief. The 4-wire power supply
cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper
wires and match a 4-wire receptacle of NEMA Type
14-30R. The ground wire (ground conductor) may be either green
or bare. The neutral conductor must be identified by a white
cover.
If your outlet looks like this:
3-wire receptacle (10-30R)
Then choose a 3-wire power supply cord with ring or spade
terminals and UL listed strain relief. The 3-wire power supply
cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper
wires and match a 3-wire receptacle of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
• Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), protected with flexible metallic conduit. All
current-carrying wires must be insulated.
• 10-gauge solid copper wire (do not use aluminum).
• At least 5 ft (1.52 m) long.
GROUNDING iNSTRUCTiONS
_' For a grounded, cord-connected dryer:
This dryer must be grounded. Hnthe event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for eiectdc current.
This dryer uses a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that (s properly installed and
grounded in accordance with all (ocal codes and ordinances.
For a permanently connected dryer:
This dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or (ead on
the dryer.
WARNING: Hmproper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug on the power
suppiy cord: if it will not fit the outlet, have a proper outlet
installed by a quaiified electrician.
SAVE THESE (NSTRUCT(ONS
Power Supply Cord Direct Wire
Fire Hazard
Use a new UL listed 30 amp power supply cord,
Use a UL listed strain retiefo
Disconnect power before making e_ectrical connections,
Connect neutrat wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securety tighten al electrical connections,
Failure to do so can result in death, fire, or
electrical shock.
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
D
Fire Hazard
Use 10 gauge solid copper wire,
Use a UL listed strain relief,
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector,
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securety tighten all electrical connections,
Failure to do so can result in death, fire, or
electrical shock,
3. Install strain relief.
Style 1: Power supply cord strain relief
Remove the screws from a %" (1.9 cm) UL listed strain
relief (UL marking on strain relief). Put the tabs of the two
clamp sections into the hole below the terminal block
opening so that one tab is pointing up and the other is
pointing down, and hold in place. Tighten strain relief
screws just enough to hold the two clamp sections
together.
A. Neutral ground wire
B. External ground conductor screw
C. Center, silver-colored terminal block screw
D. Terminal block cover and hold-down screw
/
A. Strain relief tab pointing up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down
Put power supply cord through the strain relief. Be sure
that the wire insulation on the power supply cord is inside
the strain relief. The strain relief should have atight fit with
the dryer cabinet and be in a horizontal position. Do not
further tighten strain relief screws at this point.
Electrical Connection Options
If your home has: And you will be Go to Section
connecting to:
4-wire receptacle A UL listed, 4-wire connection:
(NEMA Type 14-30R) 120/240-volt Power supply cord
30-amp, dryer
power supply
minimum,
cord*
Style 2: Direct wire strain relief
Unscrew the removable conduit connector and any
screws from a 3/4"(1.9 cm) UL listed strain relief (UL
marking on strain relief). Put the threaded section of the
strain relief through the hole below the terminal block
opening. Reaching inside the terminal block opening,
screw the removable conduit connector onto the strain
relief threads.
....................... C
A. Removable conduit connector
B. Hole below terminal block opening
C. Strain relief threads
4-wire direct A fused 4-wire connection:
disconnect or Direct Wire
circuit breaker
box*
(12.7 cm)
3-wire receptacle A UL listed,
(NEMA type 10-30R) 120/240-volt
3-wire connection:
Power supply cord
30-amp, dryer
power supply
minimum,
cord*
3-wire direct A fused 3-wire connection:
disconnect or Direct Wire
circuit breaker
box*
A
B
* If local codes do not permit the connection of a cabinet-ground
conductor to the neutral wire, go to "Optional
3-wire connection" section.
4-wire connection: Power supply cord
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
B F
Put direct wire cable through the strain relief. The strain
relief should have a tight fit with the dryer cabinet and be
in a horizontal position. Tighten strain relief screw against
the direct wire cable.
4=
Now complete installation following instructions for your type
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
10
C D G
A.4-wire receptacle (NEMAtype !4-30R)
B.4-prong plug
C. Groundprong
D. Neutralprong
E.Spade terminals with upturned ends
F.s_,,(1.9 cm) UL listed strain relief
G.Ring terminals
1=
Remove center silver-colored terminal block screw.
2.
Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire
(white or center wire) of power supply cord under center,
silver-colored terminal block screw. Tighten screw.
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center silver-colored terminal block screw
B. Center silver-colored terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
E. s/4"(1.9 cm) UL listed strain relief
4-wire connection: Direct wire
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 5" (12.7 cm) of outer covering from end of cable, leaving
bare ground wire at 5" (12.7 cm). Cut 11/2'' (3.8 cm) from
3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends
of wires into a hook shape.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
Connect ground wire (green or bare) of power supply cord to
external ground conductor screw. Tighten screw.
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cord
C. 3/4"(!.9 cm) UL listed strain relief
D. Center silver-colored terminal block screw
E.Neutral ground wire
E Neutral wire (white or center wire)
4. Connect the other wires to outer terminal block screws.
Tighten screws.
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connection. Now go to
"Venting Requirements."
1=
Remove center silver-colored terminal block screw.
2.
Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and place the hooked
end (hook facing right) of the neutral wire (white or center
wire) of direct wire cable under the center screw of the
terminal block. Squeeze hooked ends together. Tighten
screw.
A ..............
\
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center silver-colored terminal block screw
B. Center silver-colored terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
E. 3/4"(1.9 cm) UL listed strain relief
11
3=
Connect ground wire (green or bare) of direct wire cable to
external ground conductor screw. Tighten screw.
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cord
C. 3/4"(1.9 cm) UL Iisted strain relief
D. Center silver-colored terminal block screw
E. Neutral ground wire
F Neutral wire (white or center wire)
4= Place the hooked ends of the other direct wire cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
!! !!
1=
Loosen or remove center silver-colored terminal block screw.
2.
Connect neutral wire (white or center wire) of power supply
cord to the center, silver-colored terminal screw of the
terminal block. Tighten screw.
A.External ground conductor screw
B.Neutral ground wire
C. Center silver-colored terminal block screw
D.Neutral wire (white er center wire)
E.3/4"(1.9cm) UL Iistedstrain relief
3. Connect the other wires to outer terminal block screws.
Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go to
"Venting Requirements."
5. Tighten strain relief screw.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connection. Now go to
"Venting Requirements."
3-wire connection: Power supply cord
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
B D E
G F
A. 3-wire receptacle (NEMA type !0-30R)
B. 3-wire plug
C. Ground prong
D. Spade terminals with up turned ends
E.3/4"(1.9 cm) UL Iisted strain relief
E Ring terminals
G. Neutral (white or center wire)
3-wire connection: Direct wire
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 31/_'' (8.9 cm) of outer covering from end of cable. Strip
insulation back 1" (2.5 cm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of wires
into a hook shape.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
12
1=
Loosen or remove center silver-colored terminal block screw.
2.
Place the hooked end of the neutral wire (white or center wire)
of direct wire cable under the center screw of terminal block
(hook facing right). Squeeze hooked end together. Tighten
screw.
A. External ground conductor screw
B.Neutral ground wire
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E.3/4"(!.9 cm) UL listed strain relief
Optional 3-wire connection
Use for direct wire or power supply cord where local codes
do not permit connecting cabinet-ground conductor to
neutral wire.
1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire
(white or center wire) of power supply cord/cable under
center, silver-colored terminal block screw. Tighten screw.
Place the hooked ends of the other direct wire cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
!! !!
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go to
"Venting Requirements."
A. External ground conductor screw
B. Center silver-colored terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
E. 3/4"(!.9 cm) UL listed strain relief
F Grounding path determined by a qualified electrician
Connect the other wires to outer terminal block screws.
Tighten screws.
!! !!
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. Connect a separate copper ground wire from the external
ground conductor screw to an adequate ground.
13
Fire Hazard
Use a heavy metam vent.
Do not use a pmastic vent.
Do not use a metam foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING: To reduce the risk of fire, this dwer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dwer exhaust must not be connected into any gas vent,
chimney, wall, ceiling or a concealed space of a building.
If using an existing vent system
• Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
• Replace any plastic or metal foil vent with rigid or flexible
heavy metal vent.
• Review Vent system chart. Modify existing vent system if
necessary to achieve the best drying performance.
If this is a new vent system
Vent material
• Use a heavy metal vent. Do not use plastic or metal foil vent.
• 4" (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE TM venting products are recommended.
DURASAFE TM vent products can be purchased from your
local Sears store or Sears Service Center. For more
information, call 1-800-4-M¥-I-IOME _ (1-800-469-4663).
Rigid metal vent
• For best drying performance, rigid metal vents are
recommended.
• Rigid metal vent is recommended to prevent crushing and
kinking.
Flexible metal vent
• Flexible metal vents are acceptable only if accessible for
cleaning.
• Flexible metal vent must be fully extended and supported
when the dryer is in its final position.
• Remove excess flexible metal vent to avoid sagging and
kinking that may result in reduced airflow and poor
performance.
• Do not install flexible metal vent in enclosed walls, ceilings or
floors.
Elbows
45° elbows provide better airflow than 90° elbows.
Good Better
Clamps
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into the interior of the
duct. Do not use duct tape.
14
Clamp
4" (10.2 cm) heavy metal exhaust vent
Exhaust
Recommended hood styles are shown here.
_ (1_4"!m)
(I0_2cm)
A. Louvered hood style
B.Box hood style
The angled hood style (shown here) is acceptable.
(6.4 cm)
An exhaust hood should cap the vent to prevent rodents and
insects from entering the home.
Exhaust hood must be at least 12" (30.5 cm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks or bushes, snow line, etc.).
• Do not use an exhaust hood with a magnetic latch.
Optional exhaust installations
This dryer can be converted to exhaust out the right side, left
side, or through the bottom. Contact your local dealer to have the
dryer converted.
Fire Hazard
Cover unused exhaust ho_es with the following kit:
279818 (white}
Contact your Ioca_ dealer.
Failure to follow these instructions can result in death,
fire, eiectrica_ shock, or serious injury.
q-
_mproper venting can cause moisture and mintto collect
indoors, which may resumt in:
[] Moisture damage to woodwork, furniture, paint,
wallpaper, carpets, etc=
[] Housecleaning problems and health problems.
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
B
C
A
.....................................e
..............................F
A
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation (not an option
with pedestal installations)
B
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance installations are shown.
Refer to the manufacturer's instructions.
=
A B
A. Over-the-top installation (also available with one
offset elbow)
B. Periscope installation
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
15
NOTE: The following kits for close clearance alternate
installations are available for purchase. For further information,
please call 1-800-4-MY-HOME ®(1-800-469-4663).
• Over-the-Top Installation:
Part Number 26-49900
• Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 26-49901 - Less than 5" (12.7 cm) mismatch
Part Number 26-49908 - 5" (12.7 cm) to 18" (45.72 cm)
mismatch
Part Number 26-49904 - 18" (45.72 cm) to 29" (73.66 cm)
mismatch
Part Number 26-49905 - 29" (73.66 cm) to 50" (127 cm)
mismatch
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent length and elbows needed for best
drying performance
• Use the Vent system chart below to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in
the Vent system chart. Exhaust systems longer than those
specified will:
• Shorten the life of the dryer.
• Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent system chart provides venting requirements that will
help to achieve the best drying performance.
Vent system chart
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add one
90° turn to the chart.
Number of Type of Box or Angled
90° turns vent leuvered hoods
or elbows hoods
0 Rigid metal 64 ft (20 m) 58 ft (17.7 m)
Flexible metal 36 ft (11 m) 28 ft (8.5 m)
1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m)
Flexible metal 31 ft (9.4 m) 23 ft (7 m)
Determine vent path
• Select the route that will provide the straightest and most
direct path outdoors.
• Plan the installation to use the fewest number of elbows and
turns.
• When using elbows or making turns, allow as much room as
possible.
• Bend vent gradually to avoid kinking.
• Use the fewest 90 ° turns possible.
2 Rigid metal 44 ft (13.4 m) 38 ft (11.6 m)
Flexible metal 27 ft (8.2 m) 19 ft (5.8 m)
3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m)
Flexible metal 25 ft (7.6 m) 17 ft (5.2 m)
4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m)
Flexible metal 23 ft (7 m) 15 ft (4.6 m)
1. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
3. Run vent to dryer location. Use the straightest path possible.
See "Determine vent path" in "Plan Vent System." Avoid 90°
turns. Use clamps to seal alljoints. Do not use duct tape,
screws or other fastening devices that extend into the interior
of the vent to secure vent.
16
1. To protect the floor, use a large flat piece of cardboard from
the dryer carton. Place cardboard under the entire back edge
of the dryer.
2. Firmly grasp the body of the dryer. Gently lay the dryer on the
cardboard. See illustration.
_\\\\\\\\\\\\\\\\
Examine the leveling legs. Find the diamond marking.
Check the levelness of the dryer. Check levelness first
side to side, then front to back.
If the dryer is not level, prop up the dryer using a wood block.
Use a wrench to adjust the legs up or down and check again for
levelness.
You can change your door swing from a right-side opening to a
left-side opening, if desired.
1. Place a towel or soft cloth on top of the dryer or work space
to protect the surface.
Remove the door assembly
1. Remove the 4 screws that hold the door hinge on the front
panel of the dryer.
4. Screw the legs into the leg holes by hand. Use a wrench to
finish turning the legs until the diamond marking is no longer
visible.
5. Place a carton corner post from dryer packaging under each
of the 2 dryer back corners. Stand the dryer up. Slide the
dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent.
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured
to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final position. Do not crush or kink vent.
3. (On gas models) check that there are no kinks in the flexible
gas line.
4. Once exhaust vent connection is made, remove corner posts
and cardboard.
A. Dryer front panel
B. Door assembly
2=
Lay the door assembly on a flat, protected surface with the
inside (inner door assembly) facing up.
3.
Remove the 6 Phillips head screws to release the outer door
assembly from the inner door assembly, as indicated below.
See illustration. It is important that you remove only the
6 indicated screws.
4. Lift the inner door assembly off the outer door assembly.
17
5. Rotate outer door 180 °.
180 °
Reverse hinge
1. Use a small flat-blade screwdriver to remove 2 plug strips
from the inner door. Slide the head of the screwdriver under
the plugs, being certain not to scratch the inner door surface.
Lift up.
6. Reassemble the inner and outer door assemblies with the
6 screws.
Reverse the strike
1. Use a small flat-blade screwdriver to remove plug strip from
the front panel dryer door opening. Slide the head of the
screwdriver under the plugs, being certain not to scratch the
dryer surface. Lift up.
2. Remove the strike.
3. Insert strike and plug strip on the opposite side.
@
2. Remove the 4 screws that attach to the inner door hinge and
move the hinge to the other side. Reinstall the 4 screws.
A. Door hinge
3. Reinstall plug strips on opposite side of the inner door.
4. Check for fingerprints on the glass. Clean glass if necessary.
5. Place the inner door assembly inside the outer door
assembly. To fit correctly, the inner door assembly edge fits
completely inside the outer door assembly edge.
A
A. Plug strip (cannotbe seen from thisangle)
B. Door strike
Reinstall the door
1. Reattach door to dryer front panel with the 4 screws.
@
18
\
\\\\\\
A. Dryer front panel
B. Door assembly
2. Check for fingerprints on the glass. Clean glass if necessary.
3. Close door and check that it latches securely.