Kenmore 11085081401, 11085087401, 11085088401, 11085089401, 11085862401 Owner’s Manual

...
®
Electric Dryer
Secadora El_ctrica
Models/Modelos 110.8508#, 8509#, 8586#, 8587#
# = color number/nQmero de color
W10034980 Sears Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com
TABLEOF CONTENTS
PROTECTION AGREEMENTS
PROTECTION AGREEMENTS ....................................................... 2
DRYER SAFETY .............................................................................. 4
INSTALLATION INSTRUCTIONS .................................................. 5
Tools and Parts ............................................................................ 5
Optional Pedestal ......................................................................... 5
Location Requirements ................................................................ 6
Electrical Requirements ................................................................ 8
Electrical Connection ................................................................... 9
Venting Requirements ............................................................... 14
Plan Vent System ...................................................................... 15
Install Vent System .................................................................... 16
Install Leveling Legs .................................................................. 16
Connect Vent ............................................................................. 17
Level Dryer ................................................................................. 17
Reverse Door Swing .................................................................. 17
Complete Installation ................................................................. 19
DRYER USE ................................................................................. 20
Starting Your Dryer .................................................................... 20
Stopping Your Dryer .................................................................. 21
Pausing or Restarting ................................................................ 21
Control Locked .......................................................................... 21
Drying and Cycle Tips ............................................................... 21
Status Lights .............................................................................. 22
Cycles ........................................................................................ 22
Options ...................................................................................... 23
Modifiers .................................................................................... 24
Changing Cycles, Options and Modifiers ................................. 24
End of Cycle Signal ................................................................... 24
TUMBLE FREETM Heated Dryer Rack ....................................... 24
DRYER CARE .............................................................................. 25
Cleaning the Dryer Location ...................................................... 25
Cleaning the Lint Screen ........................................................... 25
Cleaning the Dryer Interior ........................................................ 26
Removing Accumulated Lint ..................................................... 26
Vacation and Moving Care ........................................................ 26
Changing the Drum Light .......................................................... 26
TROUBLESHOOTING .................................................................. 27
SERVICE NUMBERS ............................................... BACK COVER
Master Protection Agreements
Congratulations on making a smart purchase. Your new Kenmore ®product is designed and manufactured for years of dependable operation. But like all products, it may require preventive maintenance or repair from time to time. That's when having a Master Protection Agreement can save you money and aggravation.
Purchase a Master Protection Agreement now and protect yourself from unexpected hassle and expense.
The Master Protection Agreement also helps extend the life of your new product. Here's what's included inthe Agreement:
v' Expert service by our 12,000 professional repair specialists v' Unlimited service and no charge for parts and labor on all
covered repairs
v' "No-lemon" guarantee - replacement of your covered
product if four or more product failures occur within twelve months
v' Product replacement if your covered product can't be fixed v' Annual Preventive Maintenance Check at your request - no
extra charge
v' Fast help by phone - phone support from a Sears technician
on products requiring in-home repair, plus convenient repair scheduling
v' Power surge protection against electrical damage due to
power fluctuations
v' Rental reimbursement if repair of your covered product takes
longer than promised
Once you purchase the Agreement, a simple phone call is all that it takes for you to schedule service. You can call anytime day or night, or schedule a service appointment online.
Sears has over 12,000 professional repair specialists, who have access to over 4.5 million quality parts and accessories. That's
the kind of professionalism you can count on to help prolong the
life of your new purchase for years to come. Purchase your Master Protection Agreement today!
Some limitations and exclusions apply. For prices and additional information, call 1-800-827-6655.
Sears Installation Service
For Sears professional installation of home appliances, garage door openers, water heaters, and other major home items, in the
U.S.A. call 1-800-4-MY-HOME ®.
KENMORE ELITE®APPLIANCE AND OPTIONAL PEDESTAL
WARRANTY
ONE YEAR LIMITED WARRANTY
When installed, operated and maintained according to all instructions supplied with the product, if this appliance fails due to a defect in material or workmanship within one year from the date of purchase, call 1-800-4-MY-HOME ®to arrange for free repair.
TWO YEAR LIMITED WARRANTY ON SENSOR SMART TM ELECTRONIC BOARD
For two years from the date of purchase, when this washer is installed, operated and maintained according to all instructions supplied with the product, Sears will replace the electronic control board if defective in materials or workmanship. After the first year, customer assumes any labor costs associated with replacement of these parts.
If this appliance is used for other than private family purposes, this warranty applies for only 90 days from the date of purchase.
THIS WARRANTY COVERS ONLY DEFECTS IN MATERIAL AND WORKMANSHIP. SEARS WILL NOT PAY FOR:
1. Expendable items that can wear out from normal use,
including but not limited to filters, belts, light bulbs, and bags.
2. A service technician to instruct the user in correct product installation, operation or maintenance.
3. A service technician to clean or maintain this product.
4. Damage to or failure of this product if it is not installed, operated or maintained according to all instructions supplied with the product.
5. Damage to or failure of this product resulting from accident, abuse, misuse or use for other than its intended purpose.
6. Damage to or failure of this product caused by the use of detergents, cleaners, chemicals or utensils other than those recommended in all instructions supplied with the product.
7. Damage to or failure of parts or systems resulting from unauthorized modifications made to this product.
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
Customer's sole and exclusive remedy under this limited warranty shall be product repair as provided herein. Implied warranties, including warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law. Sears shall not be liable for incidental or consequential damages. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, or limitations on the duration of implied warranties of merchantability or fitness, so these exclusions or limitations may not apply to you.
This warranty applies only while this appliance is used in the United States and Canada.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Sears, Roebuck and Co.
Dept. 817WA, Hoffman Estates, IL 60179
Sears Canada Inc.
Toronto, Ontario, Canada M5B 2B8
PRODUCT RECORD
In the space below, record your complete model number, serial number, and purchase date. You can find this information on the model and serial number label located on the product.
Have this information available to help you obtain assistance or service more quickly whenever you contact Sears concerning your appliance.
Model number
Serial number
Purchase date
Save these instructions and your sales receipt for future reference.
PEDESTAL PRODUCT RECORD
In the space below, record your complete model number, serial number, and purchase date. You can find this information on the model and serial number label located on the product.
Have this information available to help you obtain assistance or service more quickly whenever you contact Sears concerning your pedestal.
Model number
Serial number
Purchase date
Save these instructions and your sales receipt for future reference.
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
iMPORTANT SAFETY iNSTRUCTiONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
[] Read all instructions before using the dryer. [] Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute to
a chemical reaction that could cause a load to catch fire.
[] Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, dry- cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or
explode.
[] Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is used near children.
[] Before the dryer is removed from service or discarded,
remove the door to the drying compartment. [] Do not reach into the dryer if the drum is moving. [] Do not install or store the dryer where it will be exposed
to the weather. [] Do not tamper with controls.
SAVE THESE iNSTRUCTiONS
[] Do not repair or replace any part of the dryer or attempt
any servicing unless specifically recommended in this Use and Care Guide or in published user-repair
instructions that you understand and have the skills to carry out.
[] Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric softener or product.
[] Do not use heat to dry articles containing foam rubber or
similarly textured rubber-like materials.
[] Clean lint screen before or after each load. [] Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust, and dirt.
[] The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
[] See installation instructions for grounding requirements.
INSTALLATION INSTRUCTIONS
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed
here.
Flat-blade screwdriver Vent clamps
#2 Phillips screwdriver Caulking gun and
Adjustable wrench that opens to 1" (2.54 cm) or new exhaust vent)
hex-head socket wrench Tin snips (new vent (for adjusting dryer feet) installations)
Wire stripper (for direct _A"nut driver or socket wire installations) wrench (recommended)
Level Tape measure
Parts supplied
Remove parts package from dryer drum. Check that all parts are included.
4Leveling legs
NOTE: Do not use leveling legs if installing the dryer on a pedestal.
compound (for installing
Are you placing the dryer on a pedestal? You have the option of purchasing pedestals of different heights separately for this dryer. You may select a 13" (33 cm) or a 15.5" (39.4 cm) pedestal. These pedestals will add to the total height of the unit for a total height of approximately 51" (129.5 cm) or 53" (134.6 cm).
For a garage installation, you will need to place the 13" (33 cm) pedestal at least 6" (15.2 cm) above the floor. You will need to place the 15.5" (39.4 cm) pedestal at least 3" (7.6 cm) above the
floor.
Optional pedestal
The pedestal (with storage drawer) is available in several colors. To order, call your local Sears store. For further information,
please call 1-800-4-MY-HOME ®(1-800-469-4663).
Pedestal Color Part Height Number
13" (33 cm) White 42842
Parts needed
Check local codes. Check existing electrical supply and venting. See "Electrical Requirements" and "Venting Requirements" before purchasing parts.
For close-clearance installations between 31.5" (80.01 cm) and 37" (93.98 cm), see "Plan Vent System" section for venting requirements.
I_- 37" --_1
(93.98 cm)
Mobile home installations require metal exhaust system hardware available for purchase from your local Sears store or Sears Service Center. For further information, please call
1-800-4-MY-HOM E®(1-800-469-4663).
13" (33 cm) Bisque 42844
13" (33 cm) Graphite 42846
15.5" (39.4 cm) White 55842
15.5" (39.4 cm} Bisque 55844
15.5" (39.4 cm) Graphite 55846
15.5" (39.4 cm} Pacific Blue 55847
15.5" (39.4 cm) Champagne 55848
15.5" (39.4 cm) Sedona 55849
Explosion Hazard
Keep flammable materials and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need
A location that allows for proper exhaust installation. See
"Venting Requirements."
A separate 30-amp circuit.
If using a power supply cord, a grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See "Electrical Requirements."
A sturdy floor to support the total dryer weight of 200 Ibs (90.7 kg). The combined weight of a companion appliance
should also be considered. A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer. (If slope is greater than 1" [2.5 cm], install Extended Dryer Feet Kit, Part Number 279810.) Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level.
For a garage installation, you will need to place the dryer at least 18" (46 cm) above the floor. If using a 13" (33 cm) pedestal, you will need to place the pedestal at least 6" (15.2 cm) above the floor. If using a 15.5" (39.4 cm) pedestal, you will need to place the pedestal at least 3" (7.6 cm) above the floor.
Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.
Dryer Dimensions
501/2''
128.27 crn)
.311/2"
(90.01 cm)
* Most installations require a minimum 51/2'' (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting Requirements."
Minimum installation spacing for recessed area, custom undercounter or closet installation
The following dimensions shown are for the minimum spacing
allowed.
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door and floor moldings.
Additional spacing of 1" (2.5 cm) on all sides of the dryer is recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.
Custom undercounter installation - Dryer only
0" _
o"* o"*
(0cm) ' (68.6cm) (0cm)
*Additional spacing recommended
27"
(68.6 cm)
Installation clearances
The location must be large enough to allow the dryer door to
open fully.
Closet installation - Dryer only
0i
Recommended installation spacing for recessed or closet installation, with stacked washer and dryer
The dimensions shown are for the recommended spacing.
46 in.2*
{310cm2)
3" (7.6 cm)
| qt:lt_llll I I 24in.2 " L_I_ _ (155cm2)
I 1"I_ 31,J,"_'10"*I
(2.5cm) (80cm) (Ocm)
A
A. Side view - closet or confined area B. Closet door with vents
*Side or bottom venting - additional spacing recommended Recessed or closet installation - Dryer on pedestal
f3"
(7.6crn)
+
Iit Iq l,,m.
OO
H
©
v
0"*--_ 27"
(0 cm) (68.6 cm)
A. Recessed area B. Side view - closet or confined area
*Additional spacing recommended
**Side or bottom venting - additional spacing recommended
Minimum installation spacing for cabinet installation
The dimensions shown are for the minimum spacing allowed.
FpreCab_snetnithstt Iolatiofn_hWitcha_i dot rarmirni_uUlmdventilation
.<--0"* 11"_ 3,,J2" ....
(0 cm) (2.5 cm)(80 cm)(0 cm)
A
B
2L
3" (7.6 crn)
24 in.2 *
(158 cm 2)
*Min. top and bottom air openings for closet door
t
76"
(193 cm)
6½"**
(/4cm)
**External exhaust elbow requires additional space.
***Wall, door and floor molding may require additional spacing.
Mobile home - additional installation requirements This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).
(2.8 cm)
i
i i
6.6crn) F 2.6crn
rn) _ 7.8 crn)
0"* 31W' 1" O ** 27 0 **
(0 crn) (80.0crn) (2.8cm) (Ocm) (68.6crn) (0 cm)
*Additional spacing recommended
**Side or bottom venting - additional spacing recommended
(22.9 cra)
Mobile home installations require:
Metal exhaust system hardware, which is available for purchase from your local Sears store or Sears Service Center.
Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
It is your responsibility
Tocontact aqualified electrical installer.
To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSl/NFPA
70-latest edition and all local codes and ordinances. The National Electric Code requires a 4-wire supply
connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.
Tosupply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect
to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of
electrical connection you will be using and follow the instructions provided for it here.
This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground wire is permanently connected to the neutral conductor (white wire) within the dryer. Ifthe dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the external ground conductor screw (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground wire is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral
conductor.
If local codes do not permit the connection of a neutral ground wire to the neutral wire, see "Optional 3-wire
connection" section. A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral
conductors.
If using a power supply cord: Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.
A UL listed strain relief.
If your outlet looks like this:
4-wire receptacle (!4-30R)
Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply
cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.
If your outlet looks like this:
@
3-wire receptacle (10-30t:?)
Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply
cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire) and be:
Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.
10-gauge solid copper wire (do not use aluminum).
At least 5 ft (1.52 m) long.
GROUNDING INSTRUCTIONS
" For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
i For a permanently connected dryer: This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on
the dryer.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power
supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
Power Supply Cord
Direct Wire
Fire Hazard
Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
D
B
Fire Hazard
Use 10 gauge solid copper wire. Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to de so can result in death, fire, or
electrical shock.
3. Install strain relief.
Style 1: Power supply cord strain relief
Remove the screws from a %" (1.9 cm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections into the hole below the terminal block opening so that one tab is pointing up and the other is pointing down, and hold in place. Tighten strain relief screws just enough to hold the two clamp sections together.
A. Neutral ground wire B. External ground conductor screw
C. Center, silver-colored terminal block screw D. Terminal block cover and hold-down screw
/
/
.... ........................B
',
A. Strain relief tab pointing up B. Hole below terminal block opening C. Clamp section D. Strain relief tab pointing down
Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have atight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.
|
Style 2: Direct wire strain relief
Unscrew the removable conduit connector and any screws from a %" (1.9 cm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief through the hole below the terminal block opening. Reaching inside the terminal block opening,
screw the removable conduit connector onto the strain relief threads.
P
A
Electrical Connection Options
If your home has: And you will be Go to Section
connecting to:
4-wire receptacle A UL listed, 4-wire connection: (NEMA Type 14-30R) 120/240-volt Power supply cord
30-amp, dryer
(_ minimum,
4-wire direct A fused 4-wire connection:
(12.7 cm)
3-wire receptacle A UL listed, (NEMA type 10-30R) 120/240-volt
3-wire direct A fused 3-wire connection:
power supply cord*
disconnect or Direct Wire
circuit breakerbox*
3-wire connection:
Power supply cord
30-amp, dryer power supply
minimum, cord*
disconnect or Direct Wire
box* circuit breaker
B
........................C
A. Removable conduit connector B. Hole below terminal block opening
C. Strain relief threads
Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against
the direct wire cable.
* If local codes do not permit the connection of aframe-
grounding conductor to the neutral wire, go to "Optional 3-wire connection" section.
4-wire connection: Power supply cord
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire connections.
B F
C D E G
A. 4-wire receptacle (NEMA type 14-30R) B. 4-prong plug
C. Ground prong D. Neutral prong
E. Spade terminals with upturned ends F. 3_,,(1.9 cm) UL listed strain relief
G. Ring terminals
4=
Now complete installation following instructions for your type of electrical connection:
4-wire (recommended) 3-wire (if 4-wire is not available)
10
1=
Remove center silver-colored terminal block screw.
2.
Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center, silver-colored terminal block screw. Tighten screw.
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center silver-colored terminal block screw
B. Center silver-colored terminal block screw
C. Neutral ground wire D. Neutral wire (white or center wire)
E. 3/4"(1.9 cm) UL listed strain relief
3=
Connect ground wire (green or bare) of power supply cord to external ground conductor screw. Tighten screw.
4-wire connection: Direct wire
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 5" (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5" (12.7 cm). Cut 11/2'' (3.8 cm) from 3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends of wires into a hook shape.
When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.
A. External ground conductor screw B, Ground wire (green or bare) of power supply cord C. _" (!.9 cm) UL Iisted strain relief
D. Center silver-colored terminal block screw
E.Neutral ground wire
E Neutral wire (white or center wire)
4. Connect the other wires to outer terminal block screws. Tighten screws.
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
7. You have completed your electrical connection. Now go to "Venting Requirements."
1=
Remove center silver-colored terminal block screw.
2.
Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the
terminal block. Squeeze hooked ends together. Tighten screw.
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center silver-colored terminal block screw
B. Center silver-colored terminal block screw C. Neutral ground wire
D. Neutral wire (white or center wire)
E. _/4"(1.9 cm) UL listed strain relief
11
3.
Connect ground wire (green or bare) of direct wire cable to external ground conductor screw. Tighten screw.
A. External ground conductor screw B. Ground wire (green or bare) of power supply cord
C. 3/4"(1.9 cm) UL listed strain relief D. Center silver-colored terminal block screw
E, Neutral ground wire
F Neutral wire (white or center wire)
4. Place the hooked ends of the other direct wire cable wires
under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
!! !!
1.
Loosen or remove center silver-colored terminal block screw.
2.
Connect neutral wire (white or center wire) of power supply cord to the center, silver-colored terminal screw of the terminal block. Tighten screw.
A.External ground conductor screw
B.Neutral ground wire
C. Centersilver-colored terminal block screw D.Neutral wire (white or center wire)
E. _" (1.9 cm) UL ilsted strain relief
3. Connect the other wires to outer terminal block screws. Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go to "Venting Requirements."
5. Tighten strain relief screw.
6. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
7. You have completed your electrical connection. Now go to "Venting Requirements."
3-wire connection: Power supply cord
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
B
D E
C G F
A. 3-wire receptacle (NEMA type !0-30R)
B. 3-wire plug C. Neutral prong D. Spade terminals with up turned ends E. _" (!.9 cm) UL listed strain relief
E Ring terminals
G. Neutral (white or center wire)
3-wire connection: Direct wire
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 31/2'' (8.9 cm) of outer covering from end of cable. Strip insulation back 1" (2.5 cm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of wires into a hook shape.
1"
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
12
1=
Loosen or remove center silver-colored terminal block screw.
2.
Place the hooked end of the neutral wire (white or center wire) of direct wire cable under the center screw of terminal block
(hook facing right). Squeeze hooked end together. Tighten screw.
A. External ground conductor screw
B.Neutral ground wire
C. Center silver-colored terminal block screw D. Neutral wire (white or center wire)
E. _" (1.9 cm) UL listed strain relief
3,
Place the hooked ends of the other direct wire cable wires under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
Optional 3-wire connection
Use for direct wire or power supply cord where local codes do not permit connecting cabinet-ground conductor to neutral wire.
1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord/cable under center, silver-colored terminal block screw. Tighten screw.
D
E
!! !!
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go to "Venting Requirements."
A. External ground conductor screw
B. Center silver-colored terminal block screw
C. Neutral ground wire D. Neutral wire (white or center wire)
E. _" (1.9 cm) UL listed strain relief
E Grounding path determined by a qualified electrician
Connect the other wires to outer terminal block screws. Tighten screws.
!! !!
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
6. Connect a separate copper ground wire from the external ground conductor screw to an adequate ground.
13
Fire Hazard
Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to fellow these instructions can result in death
or fire.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances,
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, or a concealed space of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint,
Replace any plastic or metal foil vent with rigid or flexible heavy metal vent,
Review Vent system chart, Modify existing vent system if necessary to achieve the best drying performance.
If this is a new vent system
Vent material
Use a heavy metal vent, Do not use plastic or metal foil vent.
4" (10.2 cm) heavy metal exhaust vent and clamps must be used, DURASAFE TM venting products are recommended.
Rigid metal vent
For best drying performance, rigid metal vents are recommended.
Rigid metal vent is recommended to avoid crushing and kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for cleaning.
Flexible metal vent must be fully extended and supported when the dryer is in its final position.
Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.
Do not install flexible metal vent in enclosed walls, ceilings or floors.
Elbows
45° elbows provide better airflow than 90° elbows.
Good Better
Clamps
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the
duct. Do not use duct tape.
4" (10.2 cm) heavymetal exhaust vent
DURASAFE TM vent products can be purchased from your dealer. For further information, please call 1-800-4-MY-HOME ®(1-800-469-4663) or visit our website at
www.sears.com.
14
Clamp
Exhaust
Recommended hood styles are shown here.
B
(10.2 cm)
A. Louvered hood style B. Box hood style
The angled hood style (shown here) is acceptable.
(6.4cm)
An exhaust hood should cap the vent to keep rodents and insects from entering the home.
Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).
Do not use an exhaust hood with a magnetic latch.
improper venting can cause moisture and lint to collect indoors, which may result in:
[] Moisture damage to woodwork, furniture, paint,
wallpaper, carpets, etc.
[] Housecleaning problems and health problems.
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer. Other installations are possible.
B
Optional exhaust installations
This dryer can be converted to exhaust out the right side, left side, or through the bottom. Contact your local dealer to have the dryer converted.
Fire Hazard
Cover unused exhaust holes with one of the following kits:
279818 (white) 279915 (graphite) 279925 (biscuit)
280102 (pacific blue) 280103 (champagne)
280104 (sedona)
Contact your local dealer.
Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.
.............................F
.....................................G
A. Dryer
B. Elbow C. Waft D. Exhaust hood
E. Clamps
E Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows H. Exhaust outlet
B
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation (not an option
with pedestal installations)
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown.
Refer to the manufacturer's instructions.
i l/
//
r_
i ii
\
j
A
A. Over-the-top installation (also available with one offset elbow) B. Periscope installation
B
NOTE: The following kits for close clearance alternate installations are available for purchase. For further information, please call 1-800-4-MY-HOME ®(1-800-469-4663).
15
Over-the-Top Installation: Part Number 26-49900
Periscope Installation (For use with dryer vent to wall vent mismatch):
Part Number 26-49901 - Less than 5" (12.7 cm) mismatch Part Number 26-49908 - 5" (12.7 cm) to 18" (45.72 cm)
mismatch Part Number 26-49904 - 18" (45.72 cm) to 29" (73.66 cm)
mismatch Part Number 26-49905 - 29" (73.66 cm) to 50" (127 cm)
mismatch
Vent system chart
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
Number of Type of Box or Angled
90° turns vent Louvered hoods
or elbows hoods
0 Rigid metal 64 ft (20 m) 58 ft (17.7 m)
Flexible metal 36 ft (11 m) 28 ft (8.5 m)
1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m)
Flexible metal 31 ft (9.4 m) 23 ft (7 m)
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns.
When using elbows or making turns, allow as much room as possible.
Bend vent gradually to avoid kinking.
Use the fewest 90 ° turns possible.
Determine vent length and elbows needed for best drying performance
Use the Vent system chart below to determine type of vent material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those
specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent system chart provides venting requirements that will
help to achieve the best drying performance.
2 Rigid metal 44 ft (13.4 m) 38 ft (11.6 m)
Flexible metal 27 ft (8.2 m) 19ft (5.8 m)
3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m)
Flexible metal 25 ft (7.6 m) 17ft (5.2 m)
4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m)
Flexible metal 23 ft (7 m) 15 ft (4.6 m)
1. Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
3. Run vent to dryer location. Use the straightest path possible. See "Determine vent path" in "Plan Vent System." Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior
of the vent to secure vent.
L: ?ves9 L %!s
Excessive Weight Hazard
Use two or more people to move and install dryer. Failure to do so can result in back or other injury.
1. To protect the floor, use a large flat piece of cardboard from the dryer carton. Place cardboard under the entire back edge of the dryer.
2. Firmly grasp the body of the dryer (not the console panel). Gently lay the dryer on the cardboard. See illustration.
16
3=
Examine the leveling legs. Find the diamond marking.
You can change your door swing from a right-side opening to a left-side opening, if desired.
4. Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the diamond marking is no longer
visible.
5. Place a carton corner post from dryer packaging under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent.
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Make sure the vent is secured
to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final position. Do not crush or kink vent.
3. (On gas models) Check to be sure there are no kinks in the flexible gas line.
4. Once the exhaust vent connection is made, remove the corner posts and cardboard.
Check the levelness of the dryer. Check levelness first side to side, then front to back.
Remove the door
1. Place a towel or soft cloth on top of the dryer or work space to protect the surface.
2. Open the dryer door. Remove the 4 screws that hold the door hinge on the front panel of the dryer. Loosen, but do not remove, the screw with the top keyhole opening last (2nd from the top).
A. Dryer
B.Do not remove
C. Dryer door
3=
Lift and pull forward on the door so that the keyhole clears the screw head. Remove the door.
4.
Lay the dryer door on a flat, protected surface with the inside door assembly facing up. Remove the last screw from Step 2.
Remove the 6 screws to release the outer door assembly from the inner door assembly, as indicated below. See
illustration. It is important that you remove only the 6 indicated screws.
If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs up or down and check again for
levelness.
5. Lift the inner door assembly off of the outer door assembly. Set the outer door assembly aside.
Reverse the hinge and hinge cover
1. Place the inner door, screw head side up, on the work space.
2. Gently pull the plastic cover out and down. This unsnaps the plastic hinge cover from the inside door assembly.
17
3,
Remove the 4 screws that hold the hinge to the door.
4.
Move the 2 large hole screw plugs to the opposite side and insert in the original screw holes,
A. Hinge screws B. Hole screw plugs
5. Move hinge to the other side and reattach with the 4 screws removed in Step 3.
6. Reverse the plastic cover. Slide it up over the inner door assembly edge and gently snap into place.
Reverse the door handle
1. Place the outer door assembly face down on work space.
2. Remove the 2 screws that hold the door handle and the 2 screws holding the hole plugs. If hole plugs do not easily fall
out after screws are removed, insert a small screwdriver into the holes and gently push the plugs out.
A B
A. Door handle
B.Hole plugs
3. Move the door handle to the other side and reattach with the 2 screws removed from the door handle in Step 2.
4. Move the hole plugs to the new hinge side and attach with the 2 screws removed from the hole plugs in Step 2.
Reinstalling the door
1. Check for fingerprints on the glass. Clean the glass if
necessary.
2. Place the inner door assembly into the outer door assembly. Align the hinge cover and hinge in the openings on each side. To fit correctly, the inside door assembly edge is completely inside the outside door assembly edge.
3. Reassemble the inner and outer door assemblies with the 6 screws.
7. Set the inner door assembly aside.