Electric Dryer
Secadora El_ctrica
Models/Modelos 110.8508_, 8509:_, 8586:_, 8587_
= color number/nemero de color
iiiiii!Jiiiiiiiiiii!il
8572919 Sears Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com
TABLEOF CONTENTS
PROTECTION AGREEMENTS
PROTECTION AGREEMENTS ....................................................... 2
WARRANTY ..................................................................................... 3
PEDESTAL OPTION WARRANTY ................................................. 3
DRYER SAFETY .............................................................................. 4
INSTALLATION INSTRUCTIONS .................................................. 5
Tools and Parts ............................................................................ 5
Optional Pedestal ......................................................................... 5
Location Requirements ................................................................ 6
Electrical Requirements ................................................................ 7
Electrical Connection ................................................................... 9
Venting Requirements ............................................................... 14
Plan Vent System ...................................................................... 15
Install Vent System .................................................................... 16
Install Leveling Legs .................................................................. 16
Level Dryer ................................................................................. 16
Connect Vent ............................................................................. 17
Reverse Door Swing .................................................................. 17
Complete Installation ................................................................. 18
DRYER USE ................................................................................. 19
Starting Your Dryer .................................................................... 19
Stopping Your Dryer .................................................................. 20
Pausing or Restarting ................................................................ 20
Control Locked .......................................................................... 20
Loading ...................................................................................... 20
Drying and Cycle Tips ............................................................... 20
Status Lights .............................................................................. 21
Cycles ........................................................................................ 21
Options ...................................................................................... 22
Modifiers .................................................................................... 23
Changing Cycles, Options and Modifiers ................................. 23
End of Cycle Signal ................................................................... 23
TUMBLE FREETM Heated Dryer Rack ....................................... 23
DRYER CARE ............................................................................... 24
Cleaning the Dryer Location ...................................................... 24
Cleaning the Lint Screen ........................................................... 24
Cleaning the Dryer Interior ........................................................ 25
Removing Accumulated Lint ..................................................... 25
Vacation and Moving Care ........................................................ 25
Changing the Drum Light .......................................................... 25
TROUBLESHOOTING .................................................................. 26
Dryer Operation ......................................................................... 26
Dryer Results ............................................................................. 26
SERVICE NUMBERS ............................................... BACK COVER
Master Protection Agreements
Congratulations on making a smart purchase. Your new
Kenmore ®product is designed and manufactured for years of
dependable operation. But like all products, it may require
preventive maintenance or repair from time to time. That's when
having a Master Protection Agreement can save you money and
aggravation.
Purchase a Master Protection Agreement now and protect
yourself from unexpected hassle and expense.
The Master Protection Agreement also helps extend the life of
your new product. Here's what's included in the Agreement:
v' Expert service by our 12,000 professional repair specialists
v' Unlimited service and no charge for parts and labor on all
covered repairs
v' "No-lemon" guarantee - replacement of your covered
product iffour or more product failures occur within twelve
months
v' Product replacement if your covered product can't be fixed
v' Annual Preventive Maintenance Check at your request - no
extra charge
v' Fast help by phone - phone support from a Sears technician
on products requiring in-home repair, plus convenient repair
scheduling
v' Power surge protection against electrical damage due to
power fluctuations
v' Rental reimbursement if repair of your covered product takes
longer than promised
Once you purchase the Agreement, a simple phone call is all that
it takes for you to schedule service. You can call anytime day or
night, or schedule a service appointment online.
Sears has over 12,000 professional repair specialists, who have
access to over 4.5 million quality parts and accessories. That's
the kind of professionalism you can count on to help prolong the
life of your new purchase for years to come. Purchase your
Master Protection Agreement today!
Some limitations and exclusions apply. For prices and
additional information, call 1-800-827-6655.
Sears Installation Service
For Sears professional installation of home appliances, garage
door openers, water heaters, and other major home items, in the
U.S.A. call 1-800-4-MY-HOME ®.
WARRANTY
PEDESTAL OPTION
FULL ONE-YEAR WARRANTY ON MECHANICAL AND
ELECTRICAL PARTS
For one year from the date of purchase, when this dryer is
installed and operated according to the instructions provided in
this Use and Care Guide, Sears will repair this dryer, free of
charge, if defective in materials or workmanship.
NOTE: Exhausting this dryer with a plastic vent can void this
warranty. See "Installation Instructions" for the complete exhaust
requirements for this dryer.
Limited Two-Year Warranty on SENSOR SMART TM
Electronic Control Board
For the second year from the date of purchase, Sears will replace
the electronic control board if defective in material or
workmanship. You will be charged for labor after the first year.
Warranty Restriction
If the dryer is subject to other than private family use, the above
warranty coverage is effective for only 90 days.
Warranty Service
Warranty service is available by contacting the nearest Sears
Service Center. This warranty applies only while the product is in
use in the United States.
This warranty gives you specific legal rights and you may also
have other rights which vary from state to state.
For Sears Warranty information or to contact a Sears Service
Center, please refer to the service numbers located on the back
page of this manual.
Sears, Roebuck and Co.
D/817WA, Hoffman Estates, IL 60179
WARRANTY
Full One-Year Warranty on Mechanical Parts
For one year from the date of purchase, supplier will repair or
replace any of its mechanical parts if defective in material or
workmanship. This Pedestal must be installed with this dryer
according to the instructions provided in the Pedestal Installation
Instructions.
Warranty Restriction
If the Pedestal is subject to other than private family use and/or
used with any other product than those listed in the installation
instructions, this warranty is null and void.
In the space following, record your complete model number,
serial number, and purchase date. You can find this information
on the model and serial number label.
Have this information available to help you quickly obtain
assistance or service when you contact Sears concerning your
appliance.
Model number 110.
Serial number
Purchase date
Save these instructions and your sales receipt for future
reference.
Product Record
In the space following, record your complete model number,
serial number, and purchase date. You can find this information
on the model and serial number label, located at the top inside
dryer door well.
Have this information available to help you quickly obtain
assistance or service when you contact Sears concerning your
appliance.
Model number110.
Serial number
Purchase date
Save these instructions and your sales receipt for future
reference.
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
iMPORTANT SAFETY iNSTRUCTiONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
m Read all instructions before using the dryer.
m Do not ptace items exposed to cooking oiIs in your dryer.
items contaminated with cooking oils may contribute to
a chemicat reaction that could cause a load to catch fire.
m Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, dry=
cleaning solvents, other flammable, or explosive
substances as they give off vapors that could ignite or
explode.
m Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is
used near children.
m Before the dryer is removed from service or discarded,
remove the door to the drying compartment.
m Do not reach into the dryer if the drum is moving.
m Do not install or store the dryer where it will be exposed
to the weather.
m Do not tamper with controls.
SAVE THESE INSTRUCTIONS
m Do not repair or replace any part of the dryer or attempt
any servicing unless specifically recommended in this
Use and Care Guide or in published user-repair
instructions that you understand and have the skills to
carry out.
m Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric
softener or product.
m Do not use heat to dry articles containing foam rubber or
similariy textured rubber-like materials.
,, Clean lint screen before or after each load.
m Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust,
and dirt.
The interior of the dryer and exhaust vent should be
cleaned periodicaily by qualified service personnel.
See installation instructions for grounding requirements.
INSTALLATION INSTRUCTIONS
Gather the required tools and parts before starting installation.
Read and follow the safety instructions provided with any tools
listed here.
• Flat-blade screwdriver • Vent clamps
• Adjustable wrench that • Caulking gun and
opens to 1" (2.54 cm) or compound (for installing
hex-head socket wrench new exhaust vent)
(for adjusting dryer feet) • Tin snips (new vent
• Level installations)
• Wire stripper (direct wire • 1A" nut driver or socket
installations) wrench
• #2 Phillips screwdriver
Parts supplied
Remove parts package from dryer drum. Check that all parts are
included.
4Levelinglegs
NOTE: Do not use leveling legs if installing the dryer on a
pedestal.
Are you placing the dryer on a pedestal? You have the option of
purchasing pedestals of different heights separately for this dryer.
You may select a 13" (33 cm) or a 15.5" (39.4 cm) pedestal. These
pedestals will add to the total height of the unit for a total height
of approximately 51" (129.5 cm) or 53" (134.6 cm).
Optional pedestal
The pedestal (with storage drawer) is available in several colors.
To order, call your local Sears store. For further information,
please call 1-800-4-MY-HOME ®(1-800-469-4663).
Pedestal Color Part
Height Number
13" (33 cm) White 42842
13" (33 cm) Bisque 42844
13" (33 cm} Graphite 42846
Parts needed
Check local codes. Check existing electrical supply and venting.
See "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
• For close-clearance installations between 31.5" (80.01 cm)
and 37" (93.98 cm), see "Plan Vent System" section for
venting requirements.
I_- 37" --_1
(93.98 cm)
Mobile home installations require metal exhaust system hardware
available for purchase from your local Sears store or Sears
Service Center. For further information, please call
1-800-4-MY-HOME ®(1-800-469-4663).
15.5" (39.4 cm} White 55842
15.5" (39.4 cm) Bisque 55844
15.5" (39.4 cm} Graphite 55846
15.5" (39.4 cm} Pacific Blue 55847
15.5" (39.4 cm) Champagne 55848
15.5" (39.4 cm} Sedona 55849
ExplosionHazard
Keepflammabmematedatsandvapors,suchas
gasoline,away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can resumt in death, explosion, or fire.
You will need
• A location that allows for proper exhaust installation. See
"Venting Requirements."
• A separate30-amp circuit.
• A grounded electrical outlet located within 2 ft (61 cm) of
either side of the dryer. See "Electrical Requirements."
• A sturdy floor to support the total dryer weight of 200 Ibs
(90.7 kg). The combined weight of a companion appliance
should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer. (If slope is greater than 1" [2.5 cm], install Extended
Dryer Feet Kit, Part No. 279810.) Clothes may not tumble
properly and automatic sensor cycles may not operate
correctly if dryer is not level.
• For a garage installation, you will need to place the dryer at
least 18" (46 cm) above the floor. If using a pedestal, you will
need an additional 6" (15.24 cm).
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation clearances
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
* Most installations require a minimum 51/2'' (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum installation spacing for recessed area, custom
undercounter or closet installation
The following dimensions shown are for the minimum spacing
allowed.
• Additional spacing should be considered for ease of
installation and servicing.
• Additional clearances might be required for wall, door and
floor moldings.
• Additional spacing of 1" (2.5 cm) on all sides of the dryer is
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
• Companion appliance spacing should also be considered.
Custom undercounter installation - Dryer only
0"
36"rain I I ml
(66.62 c_
6" ..---_l,_ 27" -:--_1_-- 6"
(6 ore) I " (68.6 ore) I (0 cm)
Closet installation - Dryer only
3"
C7.6cm)
U
48im2
111 14 .7 mI
24)n.2 _
(155cm2)
C7.6cm)
10"_ 31a"*10"
(0cm) (80cm) (0cm)
A
A. Side view - closet or confined area
B. Closet door with vents
Recessed or closet installation - Dryer on pedestal
+
B
IH 14,414,,m
H
_--- 27" ---_b_- 0" I0"_ 31!/2"_1 0"I
COcm)
Mobile home - additional installation requirements
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280).
Mobile home installations require:
• Metal exhaust system hardware which is available for
purchase from your local Sears store or Sears Service Center.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
(6&6cm) ' Cocm) COcm) C8Ocm) COcm)
A B
A. Recessed area
B. Side view - closet or confined area
It is your responsibility
• Tocontact a qualified electrical installer.
• To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances.
The National Electric Code requires a 4-wire supply
connection for homes built after 1996, dryer circuits involved
in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.
Tosupply the required 3 or 4 wire, single phase, 120/240-volt,
60-Hz., AC-only electrical supply (or 3 or 4 wire, 120/208-volt
electrical supply, if specified on the serial/rating plate) on a
separate 30-amp circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended. Connect
to an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
• Do not use an extension cord.
• If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
• This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The green cabinet-grounding
conductor is permanently connected to the neutral conductor
(white wire) within the dryer. If the dryer is installed with a
4-wire electrical supply connection, the green cabinet-
grounding conductor must be removed from the external
ground conductor screw (green screw), and secured under
the neutral terminal (center or white wire) of the terminal
block. When the green cabinet-grounding conductor is
secured under the neutral terminal (center or white wire) of
the terminal block, the dryer cabinet is isolated from the
neutral conductor.
• If local codes do not permit the connection of a cabinet
ground conductor to the neutral wire, see "Optional 3-wire
connection" section.
• Use a 4-wire conductor cord when the dryer is installed in a
mobile home or an area where local codes do not permit
grounding through the neutral.
Ifusingapowersupplycord:
UseaULlistedpowersupplycordkitmarkedforusewith
clothesdryers.Thekitshouldcontain:
• AULlisted30-amppowersupplycord,rated
120/240-voltminimum.ThecordshouldbetypeSRDor
SRDTandbeatleast4ft(1.22m)long.Thewiresthat
connecttothedryermustendinringterminalsorspade
terminalswithupturnedends.
• AULlistedstrainrelief.
If your outlet looks like this:
4-wire receptacle (14-30R)
Then choose a 4-wire power supply cord with ring or spade
terminals and UL listed strain relief. The 4-wire power supply
cord, at least 4 ft (1.22 m) long, must have 4, 10-gauge copper
wires and match a 4-wire receptacle of NEMA Type
14-30R. The ground wire (ground conductor) may be either green
or bare. The neutral conductor must be identified by a white
cover.
If your outlet looks like this:
3-wire receptacle (10-30R)
Then choose a 3-wire power supply cord with ring or spade
terminals and UL listed strain relief. The 3-wire power supply
cord, at least 4 ft (1.22 m) long, must have 3, 10-gauge copper
wires and match a 3-wire receptacle of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
• Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), protected with flexible metallic conduit. All
current-carrying wires must be insulated.
• 10-gauge solid copper wire (do not use aluminum).
• At least 5 ft (1.52 m) long.
GROUNDING iNSTRUCTiONS
_' For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for eiectric current.
This dryer uses a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
For a permanently connected dryer:
This dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on
the dryer.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel ifyou are in doubt as to whether the dryer is
properly grounded. Do not modify the plug on the power
suppiy cord: if it wilI not fit the outlet, have a proper outlet
installed by a qualified electrician=
SAVE THESE INSTRUOTmONS
Initial Installation - for Power Supply Cord or Direct Wire Installations
Power Supply Cord Direct Wire
Fire Hazard
Use a new UL listed 30 amp power supply cord,
Use a UL listed strain relief°
Disconnect power before making e_ectrica_ connections,
Connect neutral w}re (wh}te or center w}re) to center
terminal (silver)°
Ground wire (green or bare wire) must be connected to
green ground connector,
Connect remaining 2 supply wires to remaining
2 terminals (go_d)°
Securety tighten aH electrica_ connections,
Failure to do so can result in death, fire, or
electdca_ shock,
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
D
Fire Hazard
Use 10 gauge solid copper wire,
Use a UL listed strain relief,
Disconnect power before making electdca_ connections.
Connect neutral wire (white or center wire) to center
termina_ (sHyer).
Ground wire (green or bare wire) must be connected to
green ground connector,
Connect remaining 2 supply wires to remaining
2 terminals (gold),
Securety tighten aH electrical connections,
Failure to do so can result in death, fire, or
eiectrica_ shock,
3. Install strain relief.
Style 1: Power supply cord strain relief
• Remove the screws from a %" (1.9 cm) UL listed strain
relief (UL marking on strain relief). Put the tabs of the two
clamp sections into the hole below the terminal block
opening so that one tab is pointing up and the other is
pointing down, and hold in place. Tighten strain relief
screws just enough to hold the two clamp sections
together,
A. Neutral grounding wire (green with yellow stripes)
B. External ground conductor screw
C. Center, silver-colored terminal block screw
D. Terminal block cover and hold-down screw
L.......................................................... A
/
C
A. Strain relief tab
B. Hole below terminal block opening
C. Clamp section
Put power supply cord through the strain relief. Be sure
that the wire insulation on the power supply cord is inside
the strain relief. The strain relief should have atight fit with
the dryer cabinet and be in a horizontal position.
Style 2: Direct wire strain relief
Unscrew the removable conduit connector and any
screws from a 3/4"(1.9 cm) UL listed strain relief (UL
marking on strain relief). Put the threaded section of the
strain relief through the hole below the terminal block
opening. Reaching inside the terminal block opening,
screw the removable conduit connector onto the strain
relief threads.
Electrical Connection Options
If your home has: And you will be Go to Section
connecting to:
4-wire receptacle A UL listed, 4-wire connection:
(NEMA Type 14-30R) 120/240 volt Power supply cord
30 amp, dryer
power supply
minimum,
cord*
4-wire direct A fused 4-wire connection:
disconnect or Direct Wire
circuit breaker
box*
3-wire receptacle A UL listed,
(NEMA type 10-30R) 120/240 volt
3-wire connection:
Power supply cord
30 amp, dryer
power supply
minimum,
cord*
3-wire direct A fused 3-wire connection:
disconnect or Direct Wire
circuit breaker
box*
A. Removable conduit connector
B. Hole below terminal block opening
C. Strain relief threads
Put direct wire cable through the strain relief. The strain
relief should have a tight fit with the dryer cabinet and be
in a horizontal position. Tighten strain relief screw against
the direct wire cable.
4=
Now complete installation following instructions for your type
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
* If local codes do not permit the connection of a frame-
grounding conductor to the neutral wire, go to "Optional
3-wire connection" section.
4-wire connection: Power supply cord
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
B
C
A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with upturned ends
F. s_,,(1.9 cm) UL listed strain relief
G. Ring terminals
E G
F
10
1=
Remove center silver-colored terminal block screw.
2.
Remove neutral grounding wire (green with yellow stripes)
from external ground conductor screw. Connect neutral
grounding wire and the neutral wire (white or center wire) of
power supply cord under center, silver-colored terminal block
screw. Tighten screw.
A. External ground conductor screw - Dotted line shows
position of NEUTRAL grounding wire before being moved to
center silver-colored terminal block screw
B. Center silver-colored terminal block screw
C. Neutral grounding wire (green with yellow stripes)
D. Neutral wire (white or center wire)
E. 3/_,,(1.9 cm) UL listed strain relief
4-wire connection: Direct wire
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 5" (12.7 cm) of outer covering from end of cable, leaving
bare ground wire at 5" (12.7 cm). Cut 11/2'' (3.8 cm) from
3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends
of wires into a hook shape.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
Connect ground wire (green or bare) of power supply cord to
external ground conductor screw. Tighten screw.
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cord
C. _" (1.9 cm) UL listed strain relief
D. Center silver-colored terminal block screw
E.Neutral wire (white or center wire)
F. Neutral grounding wire (green with yeflow stripes)
4. Connect the other wires to outer terminal block screws.
Tighten screws.
5. Tighten strain relief screw.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connection. Now, go to
"Venting Requirements."
1=
Remove center silver-colored terminal block screw.
2.
Remove neutral grounding wire (green with yellow stripes)
from external ground conductor screw. Connect neutral
grounding wire and place the hooked end (hook facing right)
of the neutral wire (white or center wire) of direct wire cable
under the center screw of the terminal block. Squeeze
hooked ends together. Tighten screw.
A _
A. External ground conductor screw - Dotted line shows
position of NEUTRAL grounding wire before being moved
to center silver-colored terminal block screw
B. Center silver-colored terminal block screw
C. Neutral grounding wire (green with yellow stripes)
D. Neutral wire (white or center wire)
E. 3/4"(1.9 cm) UL listed strain relief
E
11
3. Connect ground wire (green or bare) of direct wire cable to
external ground conductor screw. Tighten screw.
F
C .........
1. Loosen or remove center silver-colored terminal block screw.
2. Connect neutral wire (white or center wire) of power supply
cord to the center, silver-colored terminal screw of the
terminal block. Tighten screw.
C
A ............... _1
B .............................................. .............................D
____i_ _................................................................E
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cord
C. 3/4"(1.9 cm) UL listed strain relief
D. Center silver-colored terminal block screw
E. Neutral wire (white or center wire)
F Neutral grounding wire (green with yellow stripes)
4. Place the hooked ends of the other direct wire cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
!! !!
5. Tighten strain relief screw.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connection. Now, go to
"Venting Requirements."
3-wire connection: Power supply cord
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
B D E
A. Externalground conductor screw
B.Neutral grounding wire (green with yellow stripes)
C. Center silver-colored terminal block screw
D. Neutral wire (white er center wire)
E. _" (1.9cm) ULlisted strain relief
3. Connect the other wires to outer terminal block screws.
Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now, go to
"Venting Requirements."
3-wire connection: Direct wire
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 31/2'' (8.9 cm) of outer covering from end of cable. Strip
insulation back 1" (2.5 cm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of wires
into a hook shape.
<
12
A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug
C. Ground prong
D. Spade terminals with up turned ends
E. _" (1.9 cm) UL listed strain relief
F. Ring terminals
G. Neutral (white or center wire)
G F
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
1=
Loosen or remove center silver-colored terminal block screw.
2.
Place the hooked end of the neutral wire (white or center wire)
of direct wire cable under the center screw of terminal block
(hook facing right). Squeeze hooked end together. Tighten
screw.
A. External ground conductor screw
B.Neutral grounding wire (green with yellow stripes)
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E. _" (!.9 cm) UL listed strain relief
Place the hooked ends of the other direct wire cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
!! !!
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now, go to
"Venting Requirements."
Optional 3-wire connection
Use for direct wire or power supply cord where local codes
do not permit connecting cabinet-ground conductor to
neutral wire.
1. Remove center silver-colored terminal block screw.
2. Remove neutral grounding wire (green with yellow stripes)
from external ground conductor screw. Connect neutral
grounding wire (green with yellow stripes) and the neutral wire
(white or center wire) of power supply cord/cable under
center, silver-colored terminal block screw. Tighten screw.
D
A. External ground conductor screw
B. Center silver-colored terminal block screw
C. Neutral grounding wire (green with yellow stripes)
D. Neutral wire (white or center wire)
E. _" (!.9 cm) UL listed strain relief
F Grounding path determined by a qualified electrician
Connect the other wires to outer terminal block screws.
Tighten screws.
!! !!
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. Connect a separate copper ground wire from the external
ground conductor screw to an adequate ground.
13
Fire Hazard
Use a heavy metaB vent,
Do not use a pmastic vent.
Do not use a metaB foil vent.
Failure to follow these instructions can result in death
or fire,
• Remove excess flexible metal vent to avoid sagging and
kinking that may result in reduced airflow and poor
performance.
• Do not install flexible metal vent in enclosed walls, ceilings or
floors,
Elbows
45° elbows provide better airflow than 90° elbows
Good Better
WARNING; To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, or a concealed space of a building.
If using an existing vent system
• Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint,
Replace any plastic or metal foil vent with rigid or flexible
heavy metal vent.
Review Vent system chart. Modify existing vent system if
necessary to achieve the best drying performance.
If this is a new vent system
Vent material
• Use a heavy metal vent. Do not use plastic or metal foil vent.
• 4" (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE TM venting products are recommended.
Clamps
• Use clamps to seal all joints.
• Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into the interior of the
duct. Do not use duct tape.
!Oc
Clamp
Exhaust
Recommended hood styles are shown here.
B
(1 Oa2 C_)
A.Louvered hood style
B.Box hood style
The angled hood style (shown here) is acceptable.
4" (10.2 cm) heavymetalexhaust vent
DURASAFE TM vent products can be purchased from your
local Sears store or Sears Service Center. For more
information, call 1-800-4-MY-HOME ®(1-800-469-4663}.
Rigid metal vent
• For best drying performance, rigid metal vents are
recommended.
• Rigid metal vent is recommended to prevent crushing and
kinking.
Flexible metal vent
• Flexible metal vents are acceptable only if accessible for
cleaning.
• Flexible metal vent must be fully extended and supported
when the dryer is in its final position.
14
(&4era)
An exhaust hood should cap the vent to prevent rodents and
insects from entering the home.
Exhaust hood must be at least 12" (30,5 cm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks or bushes, snow line, etc.).
• Do not use an exhaust hood with a magnetic latch.
_mproper venting can cause moisture and lint to collect
indoors, which may result in:
[] Moisture damage to woodwork, furniture, paint,
wallpaper, carpets, etc.
[] Housecleaning problems and health problems.
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible,
B
C
.....................................F
G
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E, Clamps
F. Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
T
A B
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation (not an option
with pedestal installations)
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance installations are shown.
Refer to the manufacturer's instructions.
1 //
Optional exhaust installations
This dryer can be converted to exhaust out the right side, left
side, or through the bottom. Contact your local dealer to have the
dryer converted.
Fire Hazard
Cover unused exhaust hotes with one of the
following kits:
279818 (white)
279915 (graphite)
279925 (biscuit)
280102 (pacific Mue)
280103 (champagne)
280104 (sedona)
Contact your local dealer.
Failure to follow these instructions can resumt in death,
fire, eJectrical shock, or serious injury.
A B
A.Over-The-Topinstallation (alsoavailablewith one
offset elbow)
B.Periscope installation
NOTE: The following kits for close clearance alternate
installations are available for purchase, For further information,
please call 1-800-4-M¥-I-IOME ®(1-800-469-4663).
• Over-The-Top Installation:
Part Number 26-49900
• Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 26-49901 - Less than 5" (12.7 cm) mismatch
Part Number 26-49908 - 5" (12.7 cm) to 18" (45.72 cm)
mismatch
Part Number 26-49904 - 18" (45.72 cm) to 29" (73.66 cm)
mismatch
Part Number 26-49905 - 29" (73.66 cm) to 50" (127 cm)
mismatch
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
/
U
15
Determine vent path
• Select the route that will provide the straightest and most
direct path outdoors.
• Plan the installation to use the fewest number of elbows and
turns.
• When using elbows or making turns, allow as much room as
possible.
• Bend vent gradually to avoid kinking.
• Use the fewest 90 ° turns possible.
Determine vent length and elbows needed for best
drying performance
• Use the Vent system chart below to determine type of vent
material and hood combinations acceptable to use.
• NOTE: Do not use vent runs longer than specified inthe Vent
system chart. Exhaust systems longer than specified will:
• Shorten the life of the dryer.
• Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent system chart provides venting requirements that will
help to achieve the best drying performance.
Vent system chart
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add one
90° turn to the chart.
1. To protect the floor, use a large flat piece of cardboard from
the dryer carton. Place cardboard under the entire back edge
of the dryer. See illustration.
2. Firmly grasp the body of the dryer (not the console panel).
Gently lay the dryer on the cardboard.
\\ \\,
3.
Examine the leveling legs. Find the diamond marking.
Number of Type of Box or Angled
90° turns vent Louvered hoods
or elbows hoods
0 Rigid metal 64 ft (20 m) 58 ft (17.7 m)
Flexible metal 36 ft (11 m) 28 ft (8.5 m)
1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m)
Flexible metal 31 ft (9.4 m) 23 ft (7 m)
2 Rigid metal 44 ft (13.4 m) 38 ft (11.6 m)
Flexible metal 27 ft (8.2 m) 19 ft (5.8 m)
3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m)
Flexible metal 25 ft (7.6 m) 17 ft (5.2 m)
4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m)
Flexible metal 23 ft (7 m) 15 ft (4.6 m)
1.
Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2.
Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
3.
Run vent to dryer location. Use the straightest path possible.
See "Determine vent path." Avoid 90° turns. Use clamps to
seal all joints. Do not use duct tape, screws or other fastening
devices that extend into the interior of the vent to secure
vent.
4. Screw the legs into the leg holes by hand. Use a wrench to
finish turning the legs until the diamond marking is no longer
visible.
5. Place a carton corner post under each of the 2 dryer back
corners. Stand the dryer up. Slide the dryer on the corner
posts until it is close to its final location. Leave enough room
to connect the exhaust vent.
6.
Once connection is made and dryer is in final location,
remove corner posts and cardboard.
Check the levelness of the dryer. Check levelness first
side to side, then front to back.
If the dryer is not level, prop up the dryer using a wood block.
Use a wrench to adjust the legs up or down and check again for
levelness.
NOTE: It might be necessary to level the dryer again after it has
been moved into its final position.
16
Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured
to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final position. Do not crush or kink vent.
Make sure dryer is level.
3. (On gas models) Check to be sure there are no kinks in the
flexible gas line.
You can change your door swing from a right-side opening to a
left-side opening, if desired.
Remove the door
1. Place a towel or soft cloth on top of the dryer or work space
to protect the surface.
2. Open the dryer door. Remove the 4 screws that hold the door
hinge on the front panel of the dryer. Loosen, but do not
remove, the screw with the top keyhole opening last (2nd
from the top).
5. Lift the inner door assembly off of the outer door assembly.
Set the outer door assembly aside.
Reverse the hinge and hinge cover
1. Place the inner door, screw head side up, on the work space.
2. Gently pull the plastic cover out and down. This unsnaps the
plastic hinge cover from the inside door assembly.
\
Remove the 4 screws that hold the hinge to the door.
Move the 2 large hole screw plugs to the opposite side and
insert in the original screw holes.
B ....................._,_
.......................
A. Dryer
B. Do not remove
C. Dryer door
3,
Lift and pull forward on the door so that the keyhole clears
the screw head. Remove the door.
4.
Lay the dryer door on a flat, protected surface with the inside
door assembly facing up. Remove the last screw from Step 2.
Remove the 6 screws to release the outer door assembly
from the inner door assembly, as indicated below. See
illustration. It is important that you remove only the
6 indicated screws.
A. Hinge screws
B. Hole screw plugs
5. Move hinge to the other side and reattach with the 4 screws
removed in Step 3.
6. Reverse the plastic cover. Slide it up over the inner door
assembly edge and gently snap into place.
7. Set the inner door assembly aside.
17