Owner's Manual and
installation instructions
®
27-inch Wide
ELECTRIC DRYERS
mmml
Your dryer may look different
IMPORTANT:
Read and follow all safety
and operating instructions
before first use of this product.
Sears, Roebuck and Co., Noffman Estates, IL 60179 U.S.A.
PART NO 3405588 Rev. A PRINTED IN U.S.A
from the dryer shown.
BEFOREUSINGYOURNEWDRYER
2
SEARSELECTRICDRYERWARRANTY
iMPORTANT SAFETY iNSTRUCTiONS
iNSTALLATiON iNSTRUCTiONS
OPERATING YOUR DRYER
LAUNDRY TIPS
CARING FOR YOUR DRYER
TROUBLESHOOTING
SEARS MAINTENANCE AGREEMENT
Please read this manual. It will help
you install and operate your new
Kenmore dryer in the safest and most
economical way.
For more information about the care
and operation of Kenmore appliances
call your nearest Sears store. You will
need the complete model and serial
numbers when requesting information.
Your dryer's model and serial numbers
are located on the Model and Serial
Number Plate.
3
4
5
25
32
34
38
4O
Use the space below to record the model
number and serial number of your new
Kenmore Dryer.
Model No.
Serial No.
Date of Purchase
Keep this book and your Sears
Salescheck (receipt) in a safe place
for future reference.
FULLI-YEAR WARRANTY
ON MECHANICAL AND
ELECTRICAL PARTS
For one year from the date of purchase,
when this dryer is installed and operated
according to the instructions in the Owner's
Manual, Sears will repair or replace any
mechanical or electrical parts in this dryer,
if defective in material or workmanship.
This warranty does not cover service
calls to correct improper installation,
including dryers that have been vented
with plastic or flexible foil.
If the dryer is subjected to other than
private family use, the above warranty
coverage is effective for only 90 days.
WARRANTY SERVICE IS AVAILABLE
BY CONTACTING THE NEAREST
SEARS SERVICE CENTER IN THE
UNITED STATES.
This warranty applies only while this
product is in use in the United States.
This warranty gives you specific legal
rights, and you may also have other
rights which vary from state to state.
Sears Roebuck and Co., Dept. 817WA,
Hoffman Estates, IL 60179.
NOTE: Proper installation to comply
with the dryer's warranty is found in
the Installation Instructions of this
Owner's Manual.
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual
and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts
you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety
alert symbol and the word "DANGER" or "WARNING?
These words mean:
injured if you don't follow
You will be killed or seriously
instructions.
You can be killed or seriously
injured if you don't follow
instructions.
All safety messages will identify the hazard, tell you how to reduce the
chance of injury, and tell you what can happen if the instructions are
not followed.
YOUR SAFETY IS IMPORTANT TO US.
WARNING: To reduce the risk of fire,
electric shock, or injury to persons
when using your dryer, follow basic
precautions, including the following:
• Read all instructions before using
the dryer.
• Do not dry articles that have been
previously cleaned in, washed in, soaked
in, or spotted with gasoline, dry-cleaning
solvents, other flammable or explosive
substances as they give off vapors that
could ignite or explode.
• Do not allow children to play on or in
the dryer. Close supervision of children
is necessary when the dryer is used
near children.
• Before the dryer is removed from
service or discarded, remove the door
to the drying compartment.
• Do not reach into the dryer if the drum
is moving.
• Do not install or store this dryer where
it will be exposed to the weather.
SAVE THESE INSTRUCTIONS
• Do not tamper with controls.
• Do not repair or replace any part of the
dryer or attempt any servicing unless
specifically recommended in the Owner's
Manual or in published user-repair
instructions that you understand and
have the skills to carry out.
• Do not use fabric softeners or products
to eliminate static unless recommended
by the manufacturer of the fabric softener
or product.
• Do not use heat to dry articles containing
foam rubber or similarly textured rubber-
like materials.
• Clean lint screen before or after each
load.
• Keep area around the exhaust opening
and adjacent surrounding areas free from
the accumulation of lint, dust, and dirt.
• The interior of the machine and exhaust
duct should be cleaned periodically by
qualified service personnel.
IMPORTANT: Observe all governing codes and ordinances.
INSTALLATION OVERVIEW
For a complete list of tools and parts
needed, see pages 5-7.
A, SELECT LOCATION
FOR YOUR DRYER (pgs. 8=9)
Standard Installation (p. 8)
J
B. INSTALL LEVELING LEGS (p. 10)
Recessed Areal
Closet Installation instructions (p. 9)
\\\
\
Tools Needed: Parts Needed:
Adjustable
wrench
Two corner posts
(from dryer carton)
4 leveling legs (supplied with dryer)
Flashlight (optional
depending on installation
C,MAKE ELECTRICAL CONNECTION (pgs. 11-19)
If using a power cord:
Tools Needed:
Parts Needed:
V4-1nchnut
driver (shown)
or socket wrench
Flashlight (optional
depending on installation)
If making a direct wire connection:
Tools Needed: Parts Needed:
V4-lnch nut #2 Phillips head
driver (shown) screwdriver
or socket wrench
#2 Phillips head
screwdriver
New 3- or 4-wire, 30-amp.
U.L-listed power supply
cord kit (includes strain relief)
3- or 4-wire,
flexible armored
or non-metallic
sheathed copper cable
(with grounding wire)
U
Strain relief
Strain relief
Wire stripper Flashlight (optional
depending on installation)
D, CONNECT EXHAUST (pgs. i9-23)
Tools Needed: Parts Needed:
Tin snips Duct tape
Flashlight (optional Flat-bladed
depending on installation) screwdriver
4-Inch heavy or
flexible metal vent
4-Inch outlet
exhaust hood
4-Inch metal elbow(s)
(optional depending
on installation)
O0
(4) 4-Inch
diameter clamps
A, SELECT LOCATION
FOR YOUR DRYER
Selecting the proper location
for your dryer makes installation
easier and gives you the best
drying performance.
STANDARD INSTALLATION
Check location where dryer will be installed.
Proper installation is your responsibility.
Make sure you have everything necessary
for correct installation including proper
floor support, a level floor, and a separate • Check code requirements. Some
30-amp. fuse.
• Protect dryer from the weather. Proper
operation of dryer cycles requires
temperatures above 45°F. At lower
temperatures, the dryer may not shut
off at the end of automatic cycles.
Drying times will be extended.
Keep flammable materials and vapors,
such as gasoline, away from dryer.
Place dryer at least 18 inches above
the floor for a garage installation.
Failure to follow these instructions
can result in death, explosion, or fire.
codes limit or do not permit installation
of clothes dryers in garages, closets,
mobile homes, or sleeping quarters.
Contact your local building inspector.
Explosion Hazard
J
Separate
30-amp. fuse.
Grounded receptacle:
Within 2 feet of either
side of dryer.
\
Support: Floor must be
sturdy enough to support
a total weight of 175
pounds (includes dryer
and load weight).
Level floor: Maximum
allowable slope under entire
dryer- I inch.
RECESSED AREA/CLOSET
INSTALLATION INSTRUCTIONS
Check governing codes and ordinances.
This dryer may be installed in a recessed
area or closet.
Confined or Recessed Area Installation
Exhausting the dryer outside is recom- -_
mended. The moisture and lint indoors
may cause:
* Lint to gather inside and around the
dryer and be a fuel for a fire.
* Moisture damage to woodwork, furni-
ture, paint, wallpaper, carpet, etc. 431/8"
* Housecleaning problems and possible
health problems.
Recessed installation that is not
exhausted outside must use Exhaust
Deflector Kit Part No. 3391278. This
kit is available at your local Sears store --_-
or Sears Service Center.
Closet Installation
WARNING: To reduce the risk of fire,
this appliance must be exhausted
outdoors when installed in a closet.
NOTE: No fuel burning appliances
may be installed in the same closet
as a dryer.
Location must be large enough to fully
open dryer door.
PRODUCT DIMENSIONS
r
\
EZLoader Hamper Door
\14"
7-
18"
±
m
F-2T,-_t I<--1,,-_11,,1<--_,/2,,-_11÷***_,/2,,
FrontView SideView FrontView
(DoorNot Shown) (DoorShown) (Door With Vent)
MINIMUMiNSTALLATIONSPADING.ClosetinstallationMUST beexhansted ontside.
* Additionalclearancesfor wall, doorand floor moldings maybereqnired.O"clearance
isacceptable bntnot recommended.
** Openingis minimum forcloset door.Louvereddoorwith equivalentair
openingsis acceptable.
** * Additionalspaceis neededwhen externalexhaustelbowisilsed. Can beS" clearance
whenhouseexhanstingislinedlip directlywith dryerexhanst.
* The installation spacing is in inches
and is the minimum allowable.
* Additional spacing should be
considered for ease of installation
and servicing.
* If closet door is installed, the
minimum air openings in top and
J¢-_414"
*'48sq.in=
rfllnlmufil
ventilation
**24sq.in.
l area
inlnllflg rll =
ventilation
ai'ea
bottom are required. Louvered doors
with equivalent air openings in top
and bottom are acceptable.
* Closet installation must be exhausted
outside. Other installations must use at
least the minimum dimensions indicated.
B. iNSTALL LEVELING LEGS
Leveling your dryer correctly will
reduce operating noise and provide
improved drying performance.
STEP 1. Take two of the cardboard
corners from the carton. Place them on
the floor in back of the dryer.
STEP 2. Firmly grasp the body of the
dryer (not the top or console panel).
Gently lay dryer on the cardboard
corners.
STEP 3. With one of the legs in hand,
check the ridges for a diamond marking.
STEP 5. Now stand the dryer up and
move it close to its final location. Leave
enough room to connect the exhaust
vent.
STEP 6. Check levelness of dryer by
placing a level on top of the dryer, first
side-to-side; then front-to-back.
STEP 7. If dryer is not level, prop the
dryer up using two stacked cardboard
corner posts. Use a wrench to adjust
the legs up or down.
STEP 4. Start to screw the legs into the
holes by hand. Use a wrench to finish
turning the legs until diamond marking
is no longer visible. This is when we
recommend you start checking the
dryer for levelness. Further adjustment
may be necessary.
I0
I
i
NOTE: It may be necessary to level
the dryer again after it is moved into
its final position.
C.MAKE ELECTRICAL
CONNECTION
It is your responsibility:
• To contact a qualified electrical installer.
• To assure that the electrical installation
is adequate and in conformance with
the National Electrical Code, ANSI/
NFPA 70-latest edition and all local
codes and ordinances.
Copies of the code standards listed
above may be obtained from:
National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
ELECTRICAL REQUIREMENTS
The proper electrical connection
ensures a safe installation that
meets local code requirements,
A three-wire or four-wire, single
phase 120/240-volt, 60-Hz., AC-only,
electrical supply (or three-wire or
four-wire, 120/208-volt if specified on
serial/rating plate) is required on a
separate 30-ampere circuit, fused on
both sides of the line. A time-delay fuse
or circuit breaker is recommended.
This dryer is manufactured with the
3-wire, frame-grounding conductor
connected to the NEUTRAL (center)
of the wiring harness of the terminal
block. Do not have a fuse in the
neutral or grounding circuit. A fuse
in the neutral or grounding circuit
could result in an electrical shock.
Use a 4-conductor cord when the
dryer is installed in a mobile home or
an area where local codes do not
permit grounding through the neutral.
ELECTRICAL CONNECTION OPTIONS
If Your Home Has:
A 3-wire electrical
receptacle
(NEMA Type 10-30R)
3-wire direct A fused disconnect or 13 - II.
A 4-wire electrical
receptacle
(NEMA Type 14-30R)
4-wire direct A fused disconnect or 18 - IV.
*If local codes do not permit the connection of a frame-grounding conductor
to the neutral wire, see the instructions on page 15.
And You Will Be Go To
Connecting To: Page
A U.L.-tisted, 120/240-volt
minimum, 30-amp., dryer
power supply cord.*
circuit breaker box*
A U.L.-tisted, 120/240-volt
minimum, 30-amp., dryer
power supply cord.
circuit breaker box.
12-1.
16- III.
I1
I. THREE-WIRE ELECTRICAL
CONNECTION TO RECEPTACLE
Use a 3-wire power supply cord:
Electrical Shock Hazard
Turn power supply off before
connecting cord,
Use a new 30-ampere power
suppty cord,
Plug into a grounded outlet.
Failure to follow these instructions
can result in death, fire, or
electrical shock.
Local codes may permit the use of
a U.L-listed, 120/240-volt minimum,
30-ampere, dryer power supply cord
kit (pigtail). Power supply cord should
be type SRD or SRDT and be at least
four feet long. The wires that connect
to the dryer must end with ring terminals
or spade terminals with upturned ends.
Spade terminals ...-...._...= __
with upturned ends
This blade connected Ring
Do not use an extension cord with
this dryer.
Do not connect plug end of power
supply cord into a live receptacle
before connecting power supply cord
to dryer terminal block.
GROUNDING INSTRUCTIONS
This appliance must be grounded.
In the event of malfunction or break-
down, grounding will reduce the risk
of electric shock by providing a path
of least resistance for electric current.
The power supply cord must be plugged
into an appropriate outlet that is properly
installed and grounded in accordance
with all local codes and ordinances.
WARNING: Improper connection of the
equipment-grounding conductor can
result in a risk of electric shock. Check
with a qualified electrician or serviceman
if your are in doubt as to whether the
appliance is properly grounded.
Do not modify the plug on the power
supply cord. If it will not fit the outlet,
have a proper outlet installed by a
qualified electrician.
STEP 1. Turn power supply off.
STEP 2. Remove hold-down screw
and terminal block cover.
Held-downscrew Terminalblock cover
ah' U L listed," NEUTRAL
, • .- ,
strain relief (white or center)
Three-wire powersupply cord
The power supply cord must have three,
No.-10 copper wires to match a three-
wire receptacle of NEMA Type 10-30R.
Three-wire
receptacle
(NEMAType
10-30R)
I2
STEP3.Attacha3/4-inch,U.L.-listed,
strainrelieftotheholebelowterminal
blockopening.Strainreliefshouldhave
atightfitwithdryercabinetandbeina
horizontalposition.Putthepowersupply
cordthroughthestrainrelief.
STEP4.Loosenorremoveterminalblock
screws.Connecttheneutralwire(white
orcenter)ofpowersupplycordunder
thecenterscrewoftheterminalblock.
STEP5.Connecttheothertwowires
toouterterminalblockscrews.Tighten
allterminalblockscrewsfirmly.
Externalground
connector
Center silver-colored
terminal block screw
II. THREE-WIRE ELECTRICAL
CONNECTION (DIRECT WIRE)
Prepare cable as directed:
Electrical Shock Hazard
Turn power supply off before
connecting wires.
Use 10 gauge solid copper wire.
Electrically ground dryer.
Failure to follow these instructions
can result in death, fire, or
electrical shock.
_ White
-- _.'-) neutral
Neutral_
3/4",&L-listed,
strainrelief
3-Wire Connection with
Frame-Grounding Conductor
STEP 6. Tighten the strain relief screws.
STEP 7. Insert tab of terminal block
cover into slot of the dryer rear panel.
Secure cover with hold-down screw.
if local codes do not permit the
connection of a frame-grounding
conductor to the neutral wire, see
the instructions on page 15.
Otherwise, proceed with Exhaust
installation. See "CONNECT
EXHAUST" on page 19.
wire
The dryer can be connected directly
to fused disconnect or circuit breaker
box with three-wire, flexible armored
or non-metallic sheathed copper cable
(with grounding wire). All current-carrying
wires must be insulated.
A conduit connector must be installed at
junction box. Allow four feet of slack in the
line so dryer can be moved if servicing
is ever necessary.
GROUNDING INSTRUCTIONS
This appliance must be connected to
a grounded metal, permanent wiring
system; or an equipment-grounding
conductor must be run with the circuit
conductors and connected to the
equipment-grounding terminal or
lead on the appliance.
STEP 1. Turn power supply off.
STEP la. Strip 31/2 inches of outer
covering from end of cable. If using
3-wire cable with grounding wire, cut
the bare wire even with outer covering.
_31/2" I
I3