SENSOR SMART TMElectric Dryer
KING SIZE TMCapacity Plus
Secadora El_ctrica SENSOR SMART TM
a capacidad extra grande (KING SIZE TM"Plus")
3979095B Sears Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com
TABLE OF CONTENTS
SERVICE .......................................................................................... 3
WARRANTY ..................................................................................... 3
DRYER SAFETY .............................................................................. 4
INSTALLATION INSTRUCTIONS .................................................. 5
Tools and Parts ............................................................................ 5
Location Requirements ............................................................... 5
Electrical Requirements................................................................ 6
Electrical Connection ................................................................... 8
Venting Requirements ............................................................... 12
Plan Vent System ...................................................................... 12
Install Vent System .................................................................... 14
Install Leveling Legs .................................................................. 14
Level Dryer................................................................................. 14
Connect Vent ............................................................................. 15
Complete Installation................................................................. 15
FEATURES AND BENEFITS ....................................................... 15
TOTAL CARE TM System ............................................................ 15
Auto Temp Control .................................................................... 15
EVENHEAT TM with Auto Temp Control Drying System ............ 15
"Smart" Cool Down Period ....................................................... 15
Jeans Cycle ............................................................................... 15
DRYER USE ................................................................................. 16
Starting Your Dryer .................................................................... 16
Stopping Your Dryer .................................................................. 17
Pausing or Restarting ................................................................ 17
Loading ...................................................................................... 17
Drying and Cycle Tips ............................................................... 17
Dryer Status ............................................................................... 18
Cycles ........................................................................................ 18
Options ...................................................................................... 19
Modifiers .................................................................................... 19
Changing Cycles, Options and Modifiers ................................. 20
TUMBLE FREETM Heated Dryer Rack ....................................... 20
DRYER CARE ............................................................................... 20
Cleaning the Dryer Location ...................................................... 20
Cleaning the Lint Screen ........................................................... 21
Cleaning the Dryer Interior ........................................................ 21
Removing Accumulated Lint ..................................................... 21
Vacation and Moving Care........................................................ 21
Changing the Drum Light .......................................................... 21
TROUBLESHOOTING .................................................................. 22
SERVICE NUMBERS ............................................... BACK COVER
2
SERVICE WARRANTY
Master Protection Agreements
Congratulations on making a smart purchase. Your new
Kenmore _"_applianceis designed and manufactured for years of
dependable operation. But like all products, it may require
preventive maintenance or repair from time to time. That's when
having a Master Protection Agreement can save you money and
aggravation.
Purchase a Master Protection Agreement now and protect
yourself from unexpected hassle and expense.
The Master Protection Agreement also helps extend the life of
your new appliance. Here's what's included in the Agreement:
V' Expert service by our 12,000 professional repair specialists
V Unlimited service and no charge for parts and labor on all
covered repairs
=/"No-lemon" guarantee - replacement of your covered
product if more than three product failures occur within twelve
months
=/Product replacement if your covered product can't be fixed
=/Annual Preventive Maintenance Check at your request - no
extra charge
=/Fast help by phone - non-technical and instructional
assistance on products repaired in your home, plus convenient
repair scheduling
=/Power surge protection against electrical damage due to
power fluctuations
=/Rental reimbursement if repair of your covered product takes
longer than promised
Once you purchase the Agreement, a simple phone call is all that
it takes for you to schedule service. You can call anytime day or
night, or schedule a service appointment online.
Sears has over 12,000 professional repair specialists, who have
access to over 4.5 million quality parts and accessories. That's
the kind of professionalism you can count on to help prolong the
life of your new purchase for years to come. Purchase your
Master Protection Agreement today!
Some limitations and exclusions apply. For prices and
information call 1-800-827-6655.
Sears Installa_on Service
For Sears guaranteed professional installation of home
appliances and items like garage door openers and water
heaters, in the U.S.A. call 1-800-4-MY-HOME%
Full One-Year Warranty on Mechanical and Eleckical Parts
For one year from the date of purchase, when this dryer is
installed and operated according to the instructions provided in
this Use and Care Guide, Sears will repair this dryer, free of
charge, if defective in materials or workmanship.
NOTE: Exhausting this dryer with a plastic vent can void this
warranty. See "Installation Instructions" for the complete exhaust
requirements for this dryer.
Limited Two-Year Warranty on SENSOR SMART TM
Electronic Control Board
For the second year from the date of purchase, Sears will replace
the electronic control board if defective in material or
workmanship. You will be charged for labor after the first year.
Warranty Restriction
If the dryer is subject to other than private family use, the above
warranty coverage is effective for only 90 days.
Warranty Service
Warranty service is available by contacting the nearest Sears
Service Center. This warranty applies only while the product is in
use in the United States.
This warranty gives you specific legal rights and you may also
have other rights which vary from state to state.
For Sears Warranty information or to contact a Sears Service
Center, please refer to the service numbers located on the back
page of this manual.
Sears, Roebuck and Co.
D/817WA, Hoffman Estates, IL 60179
Product Record
In the space following, record your complete model number,
serial number, and purchase date. You can find this information
on the model and serial number label, located at the top inside
dryer door well.
Have this information available to help you quickly obtain
assistance or service when you contact Sears concerning your
appliance.
Model number 110.
Serial number
Purchase date
Save these instructions and your sales receipt for future
reference.
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all
safety messages.
This symbol alerts you to potential hazards that can kill or hurt you and others.
l_ his isthe safety alert symbol.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you
what can happen if the instructions are not followed.
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic
precautions, including the following:
All safety messages will follow the safety alert symbol and either the word "DANGER" or
"WARNING." These words mean:
You can be killed or seriously injured if you don't
immediately follow instructions.
You can be killed or seriously injured if you don't
follow instructions,
IM PORTANT SAFETY INSTRUCTIONS
• Read all instructions before using the dryer.
• Do not place items exposed to cooking oils in
your dryer. Items contaminated with cooking oils
may contribute to a chemical reaction that could
cause a load to catch fire.
• Do not dry articles that have been previously
cleaned in, washed in, soaked in, or spotted with
gasoline, dry-cleaning solvents, other flammable,
or explosive substances as they give off vapors
that could ignite or explode.
• Do not allow children to play on or in the dryer.
Close supervision of children is necessary when
the dryer is used near children.
• Before the dryer is removed from service or dis-
carded, remove the door to the drying compart-
ment.
• Do not reach into the dryer if the drum is moving.
• Do not install or store the dryer where it will be
exposed to the weather.
• Do not tamper with controls.
SAVE THESE INSTRUCTIONS
• Do not repair or replace any part of the dryer or
attempt any servicing unless specifically recom-
mended in this Use and Care Guide or in published
user-repair instructions that you understand and have
the skills to carry out.
• Do not use fabric softeners or products to eliminate
static unless recommended by the manufacturer of
the fabric softener or product.
• Do not use heat to dry articles containing foam rubber
or similarly textured rubber-like materials.
• Clean lint screen before or after each load.
• Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint,
dust, and dirt.
• The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
See installation instructions for grounding require-
ments.
4
INSTALLATION
INSTRUCTIONS
Check that you have everything necessary for correct installation.
Proper installation is your responsibility.
• Flat-blade screwdriver • Safety glasses
• Adjustable wrench that • Vent clamps
opens to 1 in. or hex-
head socket wrench (for • Caulking gun and
adjusting dryer feet) compound (for installing
• Level
• Wire stripper (direct wire
installations) • Tin snips(new vent
• #2 Phillips screwdriver
new exhaust vent)
• Gloves
installations)
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the
floor for a garage installation.
Failure to do so can result in death, explosion,
or fire.
Parts supplied:
Remove parts package from dryer drum. Check that all parts
were included.
4 leveling legs
Parts needed:
Check local codes, check existing electrical supply and venting
and see "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
Mobile home installations require metal exhaust system hardware
available for purchase from your local Sears store or Sears
Service Center. For further information, please call t-800-4-MY-
HOME ®(t-800-469-4663).
You will need
• A location that allows for proper exhaust installation. See
"Venting Requirements."
• A separate 30 amp circuit.
• A grounded electrical outlet located within 2 ft (61 cm) of
either side of the dryer. See "Electrical Requirements."
• A sturdy floor to support the total weight (dryer and load) of
200 Ibs (99.7 kg).
A level floor with a maximum slope of 1 in. (2.5 cm) under
entire dryer. (If slope is greater than 1 in. [2.5 cm], install
Extended Dryer Feet Kit, Part No. 279819.) Clothes may not
tumble properly and models with automatic sensor cycles
may not operate correctly if dryer is not level.
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
Install the dryer where it is protected from water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation Clearances
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
*Most installations require a minimum 5t/2in. (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum installation spacing for recessed area or closet
installation
The dimensions shown following are for the minimum spacing
allowed.
• Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
• Companion appliance spacing should also be considered.
_3"
(_.7=.)
JE
_-3"
1"
(2.s_) {zsan) {_) {74.so,n)(t4_)
2
.8era)
.6_)
Mobile Home-Additional Installation Requirements
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280).
Mobile home installations require:
• Metal exhaust system hardware which is available for
purchase from your local Sears store or Sears Service Center.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
It is your responsibility
• To contact a qualified electrical installer.
• To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSl/NFPA
70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association, Batterymarch Park,
Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240-volt,
60-Hz., AC-only electrical supply (or 3 or 4wire, 120/208-volt
electrical supply, if specified on the serial/rating plate) on a
separate 30-amp circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended. Connect
to an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
• Do not use an extension cord.
• If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
• If local codes do not permit the connection of a cabinet
ground connector to the neutral wire, see "Optional 3-wire
connection" section.
This dryer is manufactured with a 3-wire, cabinet-ground
conductor connected to the NEUTRAL (white or center wire)
of the wiring harness at the terminal block.
Use a 4-wire conductor cord when the dryer is installed in a
mobile home or an area where local codes do not permit
grounding through the neutral.
1. Recessed area
2. Side view - closet or confined area
3, Closet door with vents
6
If using a power supply cord:
Use a UL approved power supply cord kit marked for use with
clothes dryers. The kit should contain:
• A UL approved 30 amp power supply cord, rated 120/240
volt minimum. The cord should be type SRD or SRDT and be
at least 4 ft (1.22 m) long. The wires that connect to the dryer
must end in ring terminals or spade terminals with upturned
ends.
• A UL approved strain relief.
If your outlet looks like this:
©
4-wire receptacle (14-30R)
Then choose a 4-wire power supply cord with ring or spade
terminals and UL approved strain relief. The 4-wire power supply
cord, at least 4 ft (1.22 m) long, must have 4, 10 gauge solid
copper wires and match a 4-wire receptacle of NEMA Type
14-30R. The ground wire (ground conductor) may be either green
or bare. The neutral conductor must be identified by a white
cover.
If your outlet looks like this:
©
3-wire receptacle (10-30R)
Then choose a 3-wire power supply cord with ring or spade
terminals and UL approved strain relief. The 3-wire power supply
cord, at least 4 ft (1.22 m) long, must have 3, No.-10 copper wires
and match a 3-wire receptacle of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
• Flexible armored or non-metallic sheathed copper cable (with
ground wire). All current-carrying wires must be insulated.
• 10 gauge solid copper wire (do not use aluminum).
• At least 4 ft (1.22 m) long.
GROUNDING INSTRUCTIONS
• For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction
or breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current. This
dryer uses a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and ground-
ed in accordance with all local codes and ordinances.
• For a permanently connected dryer:
This dryer must be connected to a grounded metal, permanent
wiring system, or an equipment-grounding conductor must be
run with the circuit conductors and connected to the equip-
ment-grounding terminal or lead on the dryer.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the dryer is proper-
ly grounded. Do not modify the plug on the power supply cord:
if it will not fit the outlet, have a proper outlet installed by a
qualified electrician.
SAVE THESE INSTRUCTIONS
PowerSupplyCord DirectWire
FireHazard
UseanewULapproved30amppower
supplycord.
UseaULapprovedstrainrelief.
Disconnectpowerbeforemakingelectrical
connections.
Connectneutralwire(whiteorcenterwire)to
centerterminal(silver).
Groundwire(greenorbarewire)mustbe
connectedto greengroundconnector.
Connectremaining2supplywiresto remaining
2terminals(gold).
Securelytightenallelectricalconnections.
Failureto dosocanresultindeath,fire,or
electricalshock.
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
1 2 3 4
FireHazard
Use10gaugesolidcopperwire.
UseaULapprovedstrainrelief.
Disconnectpowerbeforemakingelectrical
connections.
Connectneutralwire(whiteorcenterwire)to
centerterminal(silver).
Groundwire(greenorbarewire)mustbe
connectedto greengroundconnector.
Connectremaining2supplywiresto remaining
2terminals(gold).
Securelytightenallelectricalconnections.
Failureto dosocanresultindeath,fire,or
electricalshock.
3.
Assemble a 3/4in. (1.9 cm) UL approved strain relief (UL
marking on strain relief) into the hole below the terminal block
opening. Tighten strain relief screws just enough to hold the
two clamp sections together. Put power supply cord through
the strain relief, The strain relief should have a tight fit with the
dryer cabinet and be in a horizontal position.
5
6
4. Now complete installation following instructions for your type
of electrical connection:
4-wire (recommended)
1. Terminal block cover
2. External ground connector
3, Center, silver-colored terminal block screw
4. Hold-down screw
5. Neutral grounding wire (green/yellow)
6, Hole below terminal block opening
8
3-wire (if 4-wire is not available)
Electrical Connection Options
If your home has: And you will be Go to Section:
connecting to:
4-wire receptacle A UL listed, 4-wire connection:
(NEMA type 14-30R) 120/240 volt Power Supply
amp., dryer
(_ minimum, 30 Cord
power supply
cord*
4-wire direct A fused 4-wire connection:
circuit breaker
disconnect or Direct Wire
box*
3-wire receptacle A UL listed, 3-wire connection:
(NEMA type 10-30R) 120/240 volt Power Supply
amp., dryer
power supply
minimum, 30 Cord
cord*
3-wire direct A fused 3-wire connection:
disconnect or Direct Wire
circuit breaker
box*
1. Remove center terminal block screw.
2. Remove appliance ground wire (green with yellow stripes)
from external ground connector screw. Fasten it under center,
silver-colored terminal block screw.
1. External ground connector - Dotted line shows position
of NEUTRAL ground wire before being moved to center
terminal block screw
2, Center silver-colored terminal block screw
3. Green/yellow wire of harness
3. Connect ground wire (green or bare) of power supply cord to
external ground conductor screw. Tighten screw.
4. Connect neutral wire (white or center wire) of power supply
cord under center screw of the terminal block.
*If local codes do not permit the connection of a frame-grounding
conductor to the neutral wire, go to "Optional 3-wire
connection" section.
4-wire connection: Power supply cord
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
2
6
5 7
1, 4-wire receptacle (NEMA type 14-30R)
2. 4-prong plug
3. Ground prong
4. Neutral prong
5. Spade terminals with upturned ends
6. ¾in. (1.9 cm) UL approved strain relief
7. Ring terminals
1. External ground connector
2. Green wire of power supply cord or bare copper wire
3. ¾ in (1.9 cm) UL-listed strain relief
4. Center silver-colored terminal block screw
5, Neutral wire (white or center wire)
6. Neutral grounding wire (green/yellow)
5. Connect the other wires to outer terminal block screws.
Tighten screws.
6. Tighten strain relief screws.
7. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
4-wire connection: Direct Wire
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3 wire
connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 5 in. (12.7 cm) of outer covering from end of cable, leaving
bare ground wire at 5 in. (12.7 cm). Cut 11/2in. (3.8 cm) from 3
remaining wires• Strip insulation back 1 in. (2.5 cm). Shape ends
of wires into a hook shape.
3. Connect ground wire (green or bare) of power supply cable to
external ground conductor screw. Tighten screw•
4. Placethehookedendoftheneutralwire(whiteorcenterwire)
of power supply cable under the center screw of terminal
block (hook facing right). Squeeze hooked end together.
Tighten screw.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw.
1. Remove center terminal block screw.
2. Remove appliance ground wire (green with yellow stripes)
from external ground connector screw. Fasten it under center,
silver-colored terminal block screw.
3
1• External ground connector - Dotted line shows position
of NEUTRAL ground wire before being moved to center
terminal block screw
2, Center silver-colored terminal block screw
3• Green/yellow wire of harness
1, External ground connector
2. Green wire of power supply cord or bare copper wire
3. _ in. (1•9 cm) UL-tisted strain relief
4. Center silver-colored terminal block screw
5. Neutral wire (white or center wire)
6. Neutral grounding wire (green/yellow)
5. Place the hooked ends of the other power supply cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
I I
6. Tighten strain relief screws.
7. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
3-wire connection: Power supply cord
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
2 4 5
10
1•3-wire receptacle (NEMA type 10-30R)
2. 3-wire plug
3. Neutral prong
4. Spade terminals with up turned ends
5, ¾ in (1.9 cm) UL approved strain relief
6. Ring terminals
7. Neutral wire (white or center wire)
1. Loosen or remove center terminal block screw.
2. Connect neutral wire (white or center wire) of power supply
cord to the center, silver-colored terminal screw of the
terminal block. Tighten screw.
1.External ground connector
2. Neutral grounding wire (green/yellow)
3. Centersilver-colored terminalblock screw
4. Neutral wire (white or center wire)
5. _in. (1.9 crn) UL-listed strain relief
3. Connect the other wires to outer terminal block screws.
Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
1. Loosen or remove center terminal block screw.
2. Place the hooked end of the neutral wire (white or center wire)
of power supply cable under the center screw of terminal
block (hook facing right). Squeeze hooked end together.
Tighten screw.
3
2 4
1, External ground connector
2. Neutral grounding wire (green/yellow)
3. Center silver-colored terminal block screw
4. Neutral wire (white or center wire)
5. _ in. (1.9 cm) UL-listed strain relief
3. Place the hooked ends of the other power supply cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
3-wire connection: Direct Wire
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 3V2in. (8.9 cm) of outer covering from end of cable. Strip
insulation back 1 in. (2.5 cm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of wires
into a hook shape.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw. See following
example.
!! !
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
Optional 3-wire connection
Use for direct wire or power supply cord where local codes
do not permit connecting cabinet-ground conductor to
neutral wire.
1. Remove center terminal block screw.
2. Remove appliance ground wire (green with yellow stripes)
from external ground connector screw. Connect appliance
ground wire and the neutral wire (white or center wire) of
power supply cord/cable under center, silver-colored terminal
block screw. Tighten screw.
3. Connect the other wires to outer terminal block screws.
Tighten screws.
!! !!
11
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. Connect a separate copper ground wire from the external
ground connector screw to an adequate ground.
3
1, External ground connector
2. Neutral grounding wire (green/yellow)
3. Neutral wire (white or center wire)
4. Grounding path determined by a qualified electrician
• The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, or a concealed space of a building.
• Do not use an exhaust hood with a magnetic latch.
• Do not install flexible metal vent in enclosed walls, ceilings or
floors.
Use clamps to seal all joints. Exhaust vent must not be
connected or secured with screws or other fastening devices
which extend into the interior of the duct, Do not use duct
tape,
IMPORTANT: Observe all governing codes and ordinances.
Improper venting can cause moisture and lint to collect
indoors, which may result in:
• Moisture damage to woodwork, furniture, paint, wall-
paper, carpets, etc.
• Housecleaning problems and health problems.
Use a heavy metal vent. Do not use plastic or metal foil vent.
Rigid metal vent is recommended to prevent crushing and
kinking.
Flexible metal vent must be fully extended and supported when
the dryer is in its final position, Remove excess flexible metal vent
to avoid sagging and kinking that may result in reduced airflow
and poor performance.
An exhaust hood should cap the vent to prevent rodents and
insects from entering the home.
Exhaust hood must be at least 12 in. (30.5 cm) from the ground or
any object that may be in the path of the exhaust (such as
flowers, rocks or bushes, etc.).
If using an existing vent system, clean lint from the entire length
of the system and make sure exhau.' t hood is not plugged with
lint. Replace any plastic or metal foil vent with rigid metal or
flexible metal vent.
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in
death or fire.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
4 in. (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE TM venting products are recommended and are
available from your local Sears store or Sears Service Center.
DURASAFF Mvent products can be purchased from your dealer.
For further information, please call 1-800-4-MY-HOME ®(1-800-
469-4663}or visit our Internet site at: www.sears.com or
www.sears.ea.
Typical exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
2
) ........... 3
........... 7
,,,8
1. Dryer
2. Elbow
3. Waft
4. Exhaust hood
5. Clamps
& Rigid metal or flexible metal vent
7. Vent length necessary to connect
elbows
8. Exhaust outlet
12
Optional exhaust installations
This dryer can be converted to exhaust out the right side, left
side, or through the bottom.
Fire Hazard
Cover unused exhaust holes with one of the
following kits:
279818 (white)
279915 (graphite)
279925 (biscuit)
Contact your local dealer.
Failure to follow these instructions can result in
death, fire, electrical shock, or serious injury.
NOTE: The following kits for close clearance alternate
installations are available for purchase, For further information,
please call t-800-4-M¥-NOME _ (1-800-469-4663).
• Over-The-Top Installation:
Part Number 26-49900
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 26-49901 - Less than 5 in. (12.7 cm) mismatch
Part Number 26-49908 - 5 in. (12.7 cm) to 18 in. (45.72 cm)
mismatch
Part Number 26-49904 - 18 in. (45.72 cm) to 29 in. (73.66 cm)
mismatch
Part Number 26-49905 - 29 in. (73.66 cm) to 50 in. (127 cm)
mismatch
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
2
1, Standard rear offset exhaust installation
2. Left or right side exhaust installation
3. Bottom exhaust installation
Alternate installations for close clearances
Venting systems come in many varieties, Select the type best for
your installation, Two close-clearance installations are shown.
Refer to the manufacturer's instructions,
1 2
1. Over-The-Top installation (also available
with one offset elbow)
2. Periscope installation
Determine Vent Length
1. Select the route that will provide the straightest and most
direct path outdoors. Plan the installation to use the fewest
number of elbows and turns, When using elbows or making
turns, allow as much room as possible. Bend vent gradually
to avoid kinking. Avoid 90° turns.
bet_r good
JJ
2. Determine vent length.
The maximum length of the exhaust system depends upon:
• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.
Recommended hood styles are shown here.
2
(10.2 cm)
1,Louvered hood style
2. Box hood style
13
The angled hood style (shown following) is acceptable.
2.5"
See the exhaust vent length chart that matches your hood
type for the maximum vent lengths you can use.
Exhaust systems longer than specified will:
• Shorten the life of the dryer.
• Reduce performance, resulting in longer drying times and
increased energy usage.
3. Determine the number of elbows you will need.
NOTE: Do not use vent runs longer than specified in the Vent
Length Chart.
The chart below helps you determine your maximum vent
length based on the number of 90° turns or elbows you will
need and the type of vent (rigid or flexible metal) and hood
that you will use.
Vent Length Chart
1o To protect the floor, use a large flat piece of cardboard from
the dryer carton. Place cardboard under the entire back edge
of the dryer. See illustration.
2. Firmly grasp the body of the dryer (not the top or console
panel).
Number of Type of Box or Angled
90° turns vent Iouvered hoods
or elbows hoods
O Rigid metal 64 ft (20 m) 58 ft (17.7 m)
Flexible metal 36 ft (11 m) 28 ft (8.5 m)
1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m)
Flexible metal 31 ft (9.4 m) 23 ft (7 m)
2 Rigid metal 44 ft (13.4 m) 38 ft (11.6 m)
Flexible metal 27 ft (8.2 m) 19 ft (5.8 m)
3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m)
Flexible metal 25 ft (7.6 m) 17 ft (5.2 m)
4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m)
Flexible metal 23 ft (7 m) 15 ft (4.6 m)
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add 1
90° turn to the chart.
1. (Optional) Put on safety glasses and gloves.
2. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
3. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4 in. (10.2 cm)
clamp.
4. Run vent t° dryer I°cati°n" Use the straightest path p°ssible"
See "Determine Vent Length." Avoid 90 ° turns. Use clamps to
seal all joints. Do not use duct tape, screws or other fastening
devices that extend into the interior of the vent to secure
vent.
Gently lay the dryer on the cardboard.
3. Examine the leveling legs. Find the diamond marking.
4. Screw the legs into the leg holes by hand. Use a wrench to
finish turning the legs until the diamond marking is no longer
visible.
5. Place a carton corner post under each of the 2 dryer back
corners. Stand the dryer up. Slide the dryer on the corner
posts until it is close to its final location. Leave enough room
to connect the exhaust vent.
6. Once connection is made and dryer is in final location,
remove corner posts and cardboard.
Check the levelness of the dryer. Check levelness first
side-to-side, then front-to-back.
If the dryer is not level, prop up the dryer using a wood block.
Use a wrench to adjust the legs up or down and check again for
levelness.
NOTE: It might be necessary to level the dryer again after it is
moved into its final position.
14
1. Using a 4 in. (10.2 cm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured
to exhaust hood with a 4 in. (10.2 cm) clamp.
2. Move dryer into final position. Do not crush or kink vent.
Make sure dryer is level.
3. (On gas models) Ifflexible metal tubing is used, check to be
sure there are no kinks in the flexible gas line.
FEATURES AND
BENEFITS
The exclusive TOTAL CARE TM System combines the KING
SIZETM load capacity, EVENHEATTM with Auto Temp Control,
WRINKLE GUARD ®III, and the TUMBLE FREETM heated dryer
rack to ensure total drying care for any type of fabric and load
size.
1. Check to be sure all parts are now installed. If there is an
extra part, go back through the steps to see which step was
skipped.
2. Check to be sure you have all of your tools.
3. Dispose of all packaging materials.
4. Check the dryer's final location. Be sure the vent is not
crushed or kinked.
5. Check to be sure the dryer is level. (See "Level Dryer.")
6. Plug into a grounded outlet. Turn power on.
7. Remove the blue protective film on the console and any tape
remaining on the dryer.
8. Read "Dryer Use,"
9. Wipe the dryer drum interior thoroughly with a damp cloth to
remove any dust,
10. Set the dryer on a full heat cycle (not an air cycle) for 20
minutes and start the dryer.
If the dryer will not start, check the following:
• Controls are set in a running or "On" position.
• Start button has been pushed firmly.
• Dryer is plugged into a grounded outlet.
• Electrical supply is connected.
• House fuse is intact and tight; or circuit breaker has not
tripped.
• Dryer door is closed.
11. When the dryer has been running for 5 minutes, open the
dryer door and feel for heat.
If you do not feel heat, turn the dryer off and check the
following:
• There may be 2 fuses or circuit breakers for the dryer. Check
to make sure both fuses are intact and tight, or that both
circuit breakers have not tripped. If there is still no heat,
contact a qualified technician.
NOTE: You may notice a burning odor when the dryer is first
heated. This odor is common when the heating element is first
used. The odor will go away.
....... .._. ,
In automatic drying cycles, the temperature of the clothes is
reduced by automatically turning down the heat as the clothes
become dry. This reduces over drying and provides better care of
the fabrics in your clothes.
The EVENHEAW Mwith Auto Temp Control system for drying uses
dual moisture sensing devices and SENSOR SMART TM controls,
EVENHEAW Mwith Auto Temp Control shortens drying time and
dries the load at lower temperatures for optimal fabric care, The
EVENHEAW Mwith Auto Temp Control system monitors the
temperature of the heated air to ensure that it is never too hot to
cause fabric damage. It also terminates the cycle when the
clothes are dry to reduce shrinkage.
When the selected level of dryness is reached, the dryer goes
into a cool down period lasting 2-10 minutes. Unlike other dryers
that provide a fixed 10-minute cool down, the length of the
"Smart" cool down is based on the cycle time and selected
dryness setting.
• For small loads or loads that are dried at a lower temperature,
the cool down may be as low as 2 minutes.
• For large loads or loads that are dried at a higher
temperature, the cool down will be closer to 10 minutes.
Auto Temperature Control monitors the temperature and moisture
of your clothes and turns down the temperature at the right time.
By sensing the temperature and moisture, jeans come out of the
dryer ready to wear. You can put them on without them being
damp or overdry.
15