Kenmore 11060522900, 1106062110, 11067322600, 11067332600, 11067342700 Installation Guide

...
29" (73.7CM) ELECTRIC DRYER
INSTALLATIONINSTRUCTIONS
INSTRUCCIONESDE INSTALACIONPARA
LASECADORA ELI_CTRICADE29" (73.7CM)
TableofContents
DRYER SAFETY ....................................... 1
INSTALLATION INSTRUCTIONS ............ 3
Tools and Parts...................................... 3
Location Requirements ........................ 3
Electrical Requirements ......................... 4
Electrical Connection ............................. 6
Plan Vent System ................................ 12
Install Vent System .............................. 13
Install Leveling Legs ............................ 13
Connect Vent ....................................... 13
Level Dryer ........................................... 14
Reverse Door Swing (Optional) ........... 14
Complete Installation ........................... 15
SERVICE NUMBERS ....... BACK COVER
SEGURIDAD DE LA SECADORA ......... 16
INSTRUCCIONES DE INSTALACION ..17
Herramientas y piezas ......................... 17
Requisitos de ubicaci6n ...................... 18
Requisitos electricos ........................... 19
Conexi6n electrica ............................... 21
Requisitos de ventilaci6n .................... 26
Planificaci6n del sistema de
ventilaci6n ............................................ 28
Instalaci6n del sistema de
ventilaci6n ............................................ 29
Instalaci6n de las patas niveladoras ...29
Conexi6n del ducto de escape ........... 29
Nivelaci6n de la secadora ................... 29
C6mo invertir el cierre de
la puerta (opcional) .............................. 30
Complete la instalaci6n ....................... 31
NUMEROS DE
indice
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
8576655B
" "Risk of Fire"
m
Clothes dryer installation must be performed by a qualified installer. Install the clothes dryer according to the manufacturer's instructions and local codes.
Do not install a clothes dryer with flexible plastic venting materials or flexible metal
{foil type) duct. if flexible metal duct is installed, it must be of a specific type identified
by the appliance manufacturer as suitable for use with clothes dryers. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will
obstruct clothes dryer airflow and increase the risk of fire.
m
To reduce the risk of severe injury or death, follow all installation instructions.
m
Save these instructions.
iMPORTANT SAFETY iNSTRUCTiONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
[] Read all instructions before using the dryer. [] Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
[] Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, dry= cleaning solvents, or other flammable or explosive
substances as they give off vapors that could ignite or explode.
[] Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is used near children.
[] Before the dryer is removed from service or discarded,
remove the door to the drying compartment.
[] Do not reach into the dryer if the drum is moving.
[] Do not install or store the dryer where it will be exposed
to the weather.
[] Do not tamper with controls.
SAVE THESE INSTRUCTIONS
[] Do not repair or replace any part of the dryer or attempt
any servicing unless specifically recommended in this Use and Care Guide or in published user=repair
instructions that you understand and have the skills to carry out.
[] Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric softener or product.
[] Do not use heat to dry articles containing foam rubber or
similarly textured rubber=like materials.
[] Clean lint screen before or after each load. [] Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust, and dirt.
[] The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
[] See "Electrical Requirements" located in the installation
instructions for grounding instructions.
State of California Proposition 65 Warnings: WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other reproductive harm.
2
INSTALLATION INSTRUCTIONS
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed
here.
Flat-blade screwdriver #2 Phillips screwdriver
Adjustable wrench that opens to 1" (25 mm) or
hex-head socket wrench (for adjusting dryer feet)
Wire stripper (for direct wire installations)
Parts supplied:
Remove parts package from dryer drum. Check that all parts were included.
Parts needed:
Check local codes, check existing electrical supply and venting and see "Electrical Requirements" and "Venting Requirements"
before purchasing parts. Mobile home installations require metal exhaust system hardware
available for purchase from your local Sears store or Sears Service Center. For further information, please call 1-800-4-MY-HOM E®(1-800-469-4663).
Tin snips (newvent installations)
Level
Vent clamps
Tape measure
Caulking gun and compound (for installing new exhaust vent)
4 leveling legs
Explosion Hazard
Keep fiararaable materials and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches (460 rata) above the floor
for a garage installation. Failure to do so can result in death, explosion, or fire.
You will need
A location that allows for proper exhaust installation. See "Venting Requirements."
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical outlet located within 2 ft (610 mm) of either side of the dryer. See "Electrical Requirements."
A sturdy floor to support the total weight (dryer and load) of 200 Ibs (90.7 kg). The combined weight of a companion appliance should also be considered.
A level floor with a maximum slope of 1" (25 mm) under entire dryer. (If slope is greater than 1" [25 mm], install Extended Dryer Feet Kit, Part Number 279810.) Clothes may not tumble properly and models with automatic sensor cycles may not operate correctly if dryer is not level.
Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.
Installation Clearances
The location must be large enough to allow the dryer door to open fully.
Dryer Dimensions
29" ...... "_
A
273/4 ......................
(705 I_ ,_ _ ;_}--_
C
A. Smafl opening side-swing door B. Large opening side-swing door C. Wide opening side-swing door D. Wide opening hamper door
* Most installations require a minimum 5" (127 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting Requirements."
Minimum spacing for recessed area or closet installation The following spacing dimensions are recommended for this
dryer. This dryer has been tested for spacing of 0" (0 mm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door, and floor moldings.
Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.
.... 29 ....... _\
'_ (737_nm)
(310cm)2
D
.__ 3u*
(76ram)
-f
#
24in._*-
(155cm)2
1"_1 I_ 29"-__ 1"_h"*l_ 27v,"Hsv_"_
(25ram)(737mm) (25ram)(25mm)(705mm)(140mm)
A B
A. Recessed area B. Side view - closet or confined area C. Closet door with vents
(76ram)
Mobile Home - Additional Installation Requirements
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280. Mobile home installations require:
Metal exhaust system hardware, which is available for purchase from your dealer.
Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
It is your responsibility
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances. The National Electrical Code requires a 4-wire supply
connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, ifspecified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect
to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
If local codes do not permit the connection of a neutral ground wire to the neutral wire, see "Optional 3-wire
connection" in the "Electrical Connection" section.
This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground wire is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the external ground conductor screw (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground wire is secured under the neutral terminal (center or white wire) of the terminal block, the dryer
cabinet is isolated from the neutral conductor.
A 4-wire power supply connection must be used when
311.
the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through
the neutral conductors.
* Required spacing
4
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.
A UL listed strain relief.
If your outlet looks like this:
4-wire receptacle (14-30R)
Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.
If your outlet looks like this:
At least 5 ft (1.52 m) long.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
[] For a permanently connected dryer: This dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on the dryer.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power
supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
3-wire receptacle (10-30R)
Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire) and be:
Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.
10-gauge solid copper wire (do not use aluminum).
Power Supply Cord
Direct Wire
Fire Hazard
Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire} to center
terminal.
Ground wire (green or bare wire} must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold}.
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
A B C D
Fire Hazard
Use 10 gauge copper wire. Use a UL listed strain relief.
Disconnect power before making electrical connections. Connect neutral wire (white or center wire} to center
terminal.
Ground wire (green or bare wire} must be connected to green ground connector=
Connect remaining 2 supply wires to remaining 2 terminals (gold}.
Securely tighten all electrical connections. Failure to do so can result in death, fire, or
electrical shock.
Style 1: Power supply cord strain relief
Remove the screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections into the hole below the terminal block opening so that one tab is pointing up and the other is
pointing down, and hold in place. Tighten strain relief
screws enough to hold the two clamp sections together.
A.Terminalblock cover
B. External ground conductor screw C. Center terminal block screw
D. Hold-down screw location E. Neutral ground wire
F. Hole below terminal block opening
3. Install strain relief.
6
,. o
A. Strain relief tab pointing up B. Hole below terminal block opening C. Clamp section D. Strain relief tab pointing down
Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.
Style2:Directwirestrainrelief
Unscrew the removable conduit connector and any screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief through the hole below the terminal block opening. Reaching inside the terminal block opening,
screw the removable conduit connector onto the strain relief threads.
Electrical Connection Options
If your home has: And you will be Go to Section
connecting to:
4-wire receptacle A UL listed, 4-wire connection: (NEMA Type 14-30R) 120/240-volt Power supply cord
30-amp, dryer
(_) minimum,
power supply cord*
4-wire direct A fused 4-wire connection:
circuit breaker disconnect or Direct Wire
box*
A. Removable conduit connector B. Hole below terminal block opening
C. Strain relief threads
Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against
the direct wire cable.
4.
Now complete installation following instructions for your type of electrical connection:
4-wire (recommended) 3-wire (if 4-wire is not available)
3-wire receptacle A UL listed, (NEMA type 10-30R) 120/240-volt
3-wire connection:
Power supply cord
30-amp, dryer
(_ minimum,
3-wire direct A fused
(89 mm_
power supply cord*
disconnect or circuit breaker
box*
3-wire connection:
Direct Wire
* If local codes do not permit the connection of a
cabinet-ground conductor to the neutral wire, go to
"Optional 3-wire connection" section.
4-wire connection: Power Supply Cord
IMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3-wire connections.
A B
F
C D E G
A. 4-wire receptacle (NEMA type 14-30R) B. 4-prong plug C. Ground prong D. Neutral prong E. Spade terminals with upturned ends
F. 3/4" (19 mm) UL listed strain relief
G. Ring terminals
1. Remove center terminal block screw.
2=
Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center, terminal block screw. Tighten screw.
A
E s""/i
B C
4-wire connection: Direct Wire
IMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3-wire connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving bare ground wire at 5" (127 mm). Cut 11/2"(38 mm) from 3 remaining wires. Strip insulation back 1" (25 mm). Shape ends of wires into a hook shape.
A. External ground conductor screw - Dotted fine shows
position of NEUTRAL ground wire before being moved to center terminal block screw.
B. Center terminal block screw C. Neutral wire (white or center wire)
D. 3/4" (19 mm) UL listed strain relief E. Neutral ground wire
3=
Connect ground wire (green or bare) of power supply cord to external ground conductor screw. Tighten screw.
J
F E
D
A. External ground conductor screw B. Center terminal block screw
C. Neutral wire (white or center wire) D. 3/4" (19 mm) UL listed strain relief E. Ground wire (green or bare) of power supply cord
F. Neutral ground wire
4=
Connect the other wires to outer terminal block screws. Tighten screws.
(127
When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.
1=
Remove center terminal block screw.
2.
Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the terminal block. Squeeze hooked ends together. Tighten screw.
A B
-m
/////¢
O //
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
7. You have completed your electrical connections. Now go to "Venting Requirements."
8
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to center terminal block screw.
B. Center terminal block screw C. Neutral wire (white or center wire)
D. 3/4" (19 mm) UL listed strain relief E. Neutral ground wire
3=
Connect ground wire (green or bare) of power supply cable to external ground conductor screw. Tighten screw.
A B
F E
3-wire connection: Power Supply Cord
Use where local codes permit connecting cabinet-ground
conductor to neutral wire:
A .............. _!
C G F
A. 3-wire receptacle (NEMA type 10-301:?)
B. 3-wire plug C. Neutral prong D. Spade terminals with up turned ends
E. 3/4" (19 mm) UL listed strain relief
F. Ring terminals
G. Neutral (white or center wire)
A. External ground conductor screw B. Center terminal block screw
C. Neutral wire (white or center wire) D. 3/4" (19 mm) UL listed strain relief E. Ground wire (green or bare) of power supply cable
F. Neutral ground wire
4=
Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
!
5=
Tighten strain relief screws.
6.
Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
7=
You have completed your electrical connections. Now go to "Venting Requirements."
1=
Loosen or remove center terminal block screw.
2.
Connect neutral wire (white or center wire) of power supply cord to the center terminal screw of the terminal block.
Tighten screw.
B C
/
A
A. Neutral ground wire B. External ground conductor screw
C. Center terminal block screw D. Neutral wire (white or center wire)
E.3/4" (19 mm) UL listed strain relief
3=
Connect the other wires to outer terminal block screws. Tighten screws.
!
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
6. You have completed your electrical connections. Now go to "Venting Requirements."
3-wire connection: Direct Wire
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 31/2"(89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Bend ends of wires into a hook shape.
3.
Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
!!
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
6. You have completed your electrical connections. Now go to "Venting Requirements."
Optional 3-wire connection
When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.
1=
Loosen or remove center terminal block screw.
2.
Place the hooked end of the neutral wire (white or center wire) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.
B C
Use for direct wire or power supply cord where local codes do not permit connecting cabinet-ground conductor to neutral wire.
1. Remove center terminal block screw.
2. Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord/cable under center terminal block screw. Tighten screw.
A B C
E
A. External ground conductor screw B. Neutral ground wire
C. Center terminal block screw D. Neutral wire (white or center wire)
E.3/4" (19 mm) UL listed strain relief
A. Neutral ground wire B. External ground conductor screw
C. Center terminal block screw D. Neutral wire (white or center wire)
E.3/4" (19 mm) UL listed strain relief
10
3.
E Grounding path determined by a qualified electrician
Connect the other wires to outer terminal block screws. Tighten screws.
!
Loading...
+ 22 hidden pages