KENCO ENGINEERING COMPANY
P.O. BOX 470426, TULSA, OK 74147-0426
PHONE: (918) 663-4406 FAX: (918) 663-4480
http://www.kenco-eng.com e-mail: info@kenco-eng.com
INSTALLATION INSTRUCTIONS FOR MODEL
25654 PROXIMITY SWITCHES
2. Ensure that divider valve is relieved of all pressure.
3. Remove the piston plug from divider valve.
4. Loosen (2) ¼”-20 UNC setscrews in proximity switch housing and remove magnet holder assembly.
5. Install proximity switch magnet holder assembly into divider valve piston plug connection.
6. Slide proximity switch housing over magnet holder assembly, but do not tighten setscrews.
7. Connect an ohm meter across the two white switch leads exiting ½” NPT proximity switch conduit connection.
8. Cycle divider valve piston and check ohm meter to see if reed switch actuates.
9. Adjustment is made by sliding proximity switch housing gradually until ohm meter indicates that switch is making and breaking contact.