MEDMASTER SOFTSTEP™ STEPLIGHTS
INSTALLATION INSTRUCTIONS
1
MSL SERIES
When using electrical equipment, basic safety precautions should always be followed, including the following:
IMPORTANT SAFEGUARDS
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH
THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. DISCONNECT POWER TO ALL CIRCUITS
BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT TO
AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE.
SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING
ORIENTATION, OR MOUNTING RESTRICTIONS.
SAVE THESE INSTRUCTIONS
INSTALLATION INSTRUCTIONS
1. For minimum 5/8" trade size dry wall, adjustable up to 1-1/4" (MSL/MSLD). Dry wall range 1/2" to 7/8" for MSLT. Thru-Wall, TW is
xed at 5/8" dry wall.
2. Disconnect power to main circuits before wiring xture.
3. Connect xture leads to power supply leads using connectors suitable for the gage and number of wires being used (not included).
Black or blue colored wire connects to the supply conductor, white xture lead connects to the neutral supply conductor, and the
grounding wire must be connected to a suitable ground. Same applies to the outlet (MSLD only).
4. Carefully fasten electrical gear to xture housing with hardware provided. Ensure all wires are inside the wire-way area.
5. Fasten faceplate to xture with included fasteners. MSLT or Thru-Wall (TW) will have two faceplates. Electrical gear is accessible from
one side only.
Applicable to Accessory option RB, retrofit mounting bracket only
MSL/MSLD Series, See Figure below
1. Remove two existing mounting brackets from (rough-in) xture housing if supplied.
2. Attach two new retrot brackets (A) with existing fasteners to holes.
3. Insert (rough-in) xture housing into the wall opening with the brackets resting on the outer wall surface.
4. Slide clip (B) into the T- slot as shown in Figure 1.
5. Turn fastener (C) on the clip to secure xture housing.
6. Break off Tab and discard.
7. Refer to above for wiring instructions.
Retrot Bracket (A)
Clip (B)
Fastener (C)
Break off tab after fastener is secured.
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents
found at www.kenall.com/patents. Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
MSL_F-2051_090418

INSTALLATION INSTRUCTIONS
MSL & MSLD Rough-In Install
1. Remove appropriate K.O. s.
2. Mount (rough-in) housing to a frame or structural by using the side brackets (see Figure1 for MSL and Figure 2 for MSLD).
3. IMPORTANT NOTE: Orientation of (rough-in) housing must be per either gure below.
4. Adjust brackets if required. The (rough-in) housing front edge is to be ush with the nished wall surface,
5. Applicable mounting hardware by others.
2
Adjustment Brackets (2)
Adjustment Screws (4)
Housing Front Edge
Adjustment Brackets (2)
Housing Front Edge
CUSTOMER SERVICE
For technical assistance, call 1-800-4KENALL (1-800-453-6255).
WARRANTY
For warranty information visit www.kenall.com/Resources/Certied-Performance-Warranties
Adjustment Screws (4)
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents
found at www.kenall.com/patents. Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
MSL_F-2051_090418