7. TECHNICAL DATA ........................................................................................................15
2
1. PREFACE
1.1 GENERAL
Congratulations on choosing the SuperSnake equipment. Used correctly, Kemppi products
can signicantly increase the productivity of your welding, and provide years of economical
service.
This operating manual contains important information on the use, maintenance and safety of
your Kemppi product. The technical specications of the device can be found at the end of the
manual.
Please read the manual carefully before using the equipment for the rst time. For your
own safety and that of your working environment, pay particular attention to the safety
instructions in the manual.
For more information on Kemppi products, contact Kemppi Oy, consult an authorised Kemppi
dealer, or visit the Kemppi web site at www.kemppi.com.
The specications presented in this manual are subject to change without prior notice.
Important notes
Items in the manual that require particular attention in order to minimise damage and
personal harm are indicated with the ’NOTE!’ notation. Read these sections carefully and follow
their instructions.
Disclaimer
While every eort has been made to ensure that the information contained in this guide
is accurate and complete, no liability can be accepted for any errors or omissions. Kemppi
reserves the right to change the specication of the product described at any time without
prior notice. Do not copy, record, reproduce or transmit the contents of this guide without
prior permission from Kemppi.
SuperSnake is a combined solution for distance wire feeding and restricted access welding. It
extends the reach of standard euro MIG/MAG welding guns up to 30 metres, providing simple
distance wire feeding for a variety of ller wires, taking quality welding to locations other
welding equipment can’t reach.
SuperSnake models connect easily to FastMig MXF wire feed units with a special MXF
synchronisation kit, and to ProMig 501, 501L and 530 wire feed units with a ProMig 50
synchronisation kit.
3
2. INSTALLATION
2.1 BEFORE USE
The product is packed in specially designed transport cartons. However, before use always
make sure the products have not been damaged during transportation.
Check also that you have received the components you ordered and the instruction manuals
needed, as described in the Quick start guide pack. Product packaging material is recyclable.
5. Meter display (Not available in ProMig applications)
1.
2.
1. Wire speed/Arc length regulation
2. Voltage/Power regulation
3. Pressure arm adjuster
4. Wire guide tube
5. Powered drive roll
6. Pressure drive roll
7. Brights LED
3.
5.
4.6.7.
A
V
4
2.3 CONNECTING CABLES
NOTE! Always check before use that the interconnecting cable, shielding gas hose, earth return
lead/clamp, and mains cable is in a serviceable condition. Ensure that connectors are correctly
fastened. Lose connectors can impair welding performance and damage connectors.
Sub feeder syncronization kit
To enable SuperSnake connection, MXF wire feed units must rst be tted with a FastMig MXF
synchronisation kit (W004030), and ProMig wire feed units with ProSync 50 kit (6263121).
Follow the installation instructions provided in the kit delivery.
2.3.1 Water cooled system
FastMig Pulse + MXF + FastCool 10
Pro Evolution + ProMig + ProCool 30
5.
4.
9.
1. MXF or ProMig wire feed unit
2. FastMig Pulse or Pro Evolution power source
3. FastCool or ProCool 30 water cooler and power connection
Uncoil SuperSnake taking the feed mechanism body towards the intended welding area, and
away from the welding machine. Ensure there are no tight bends before you load the ller
wire.
Ensure that the correct ller wire support liner is tted and installed correctly for the intended
welding application. Kemppi manufacturer a range of support liners for dierent ller material
types, including Steel wound and DL Teon. Please read the guide notes on liner selection and
installation before use.
6
Filler wire support liners
ø, mmmOrder number
Fe, Mc, Fc
Ss, Al, Fe, Mc, Fc
0.8 – 1.610.5W004214
15.5W004216
20.5W004217
25.5W004218
0.8 – 1.610W004145
15W004219
20W004220
25W004221
SuperSnake wire feed mechanism
Before loading the ller wire to SuperSnake please set the wire feed mechanism. Ensure the
grooved drive rolls suit the ller wire size and type. Close and adjust the pressure arm.
Ensure quality ller wire is loaded to the wire feed cabinet. Check that the correct wire guide
tube and wire drive rolls are selected and tted for the ller wire type used.
NOTE! Check that the ller wire spool is correctly mounted and locked into position. Ensure the
spool is not damaged or deformed in such a way that it can rub or cha against the internal
surface of the wire feed unit chassis or door. This may result in increased drag, impacting on weld
quality. This may also result in long term wire feed unit damage, rendering the unit unserviceable
or unsafe to use.
3.3 LOADING THE FILLER WIRE AND AUTOMATIC FEED
Automatic wire feed makes wire spool changes faster. When changing the wire spool, the
pressure of feed rolls need not be released. Simply ensure that the groove of the feed roll
matches the diameter of ller wire used. Release the wire end from the spool and cut o any
deformed section. Be careful the wire does not spill from the spool sides. Straighten about
20cm of ller and present the ller wire tip to the back of the wire feed rolls and press the wire
inch button on the wire feed panel.
8
Now take a ne le or abrasive cloth and remove any sharp edges from the ller wire end,
before loading to SuperSnake. This prevents damage to plastic liners in particular, and also
prevents pick-up and stubbing inside metal liners when loading.
NOTE! Smaller diameter ller wires may need to be loaded manually – with the feed roll pressure
arms released. This is because it is easy to over estimate the pressure required to feed these smaller
ller wires. Too high feed roll pressures can easily deform ller wires and contribute to later feeding
problems.
3.4 ADJUSTMENT OF MXF PRESSURE ARMS
Adjust the drive pressure to the ller wire with the thumb screws mounted over the pressure
arms. Notice the graduated scales indicating load. The load applied should be sucient to
overcome a light braking force applied by hand to the ller wire, as it exits the welding gun
contact tip.
For smaller diameter and soft ller wires, less feed pressure is required. It should be possible to
apply a light breaking force to the ller wire by hand, as it exits the gun contact tip. But slightly
more wire ow restriction should render the drives rolls to slip slightly over the ller wire
without deforming the wire
NOTE! Excessive pressure causes attening of the ller wire and damage to coated or cored ller
wires. It also causes undue wear of the feed rolls and increases gearbox load, so reducing service
life.
Brake force is adjusted through the hole behind the locking clip. Remove the locking clip by
hand, and adjust the tension and pressure to the friction pads mounted inside with a screw
driver. See diagram and location A.
A
The load applied varies depending on the size and weight of the ller wire and spool, but also
the ller wire feed speed set. The heavier the wire wire spool and the faster the feed speed, the
greater the need to increase the braking load. Adjust the pressure, secure the locking clip, set
the wire feed speed and check that the braking force is enough to ensure the ller wire does
not spill from the spool on overrun.
NOTE! Too much or unnecessary loads can impact welding quality, load and wear to the wire feed
Support the SuperSnake coupling and guide the ller wire into the SuperSnake liner.
Then carefully mate and connect SuperSnake to the wire feed unit connector. Secure the
SuperSnake by hand tightening the orange collar. The SuperSnake coupling transfers welding
power, shielding gas and gun trigger lines. In addition you must connect both cable plugs
to the FastMig or ProMig wire feed unit sockets (from MXF synchronisation kit W004030 or
ProMig ProSync 50 kit 6263121). This ensures wire feed motor synchronization, metering and
remote control functions. Align and connect the plugs to the sockets and lightly tighten by
hand. In ProSync applications, welding values are not shown. Instead, the display shows only
dashes – – – .
SuperSnake GT02S SuperSnake GT02SW
EN
3.6 AUTOMATIC WIRE FEED TO INTERMEDIATE CABLE AND GUN
WF #
1. WIRE INCH button
You are now ready to ‘Auto Load’ the ller wire. Ensure the FastMig or ProMig wire feed
mechanism pressure arms are in place and correctly adjusted. Press the WIRE INCH button on
the wire feed panel. MXF/PF system will automatically load the ller wire to the SuperSnake
feed mechanism, and through the gun connector block. There should be a small amount of
ller wire sticking out ready for gun connection.
NOTE! In ProMig applications, the automatic Wire Inch function is not available. You must press
and hold the Wire Inch button or welding gun trigger, until the ller wire reaches SuperSnake.
1.
10
Connecting the welding gun
Prepare your welding gun for connection. SuperSnake is designed to accept a wide variety of
welding guns tted with the standard Euro tting. To ensure reliable welding performance,
please ensure the gun is suitable for the intended welding application and is in good working
order, correctly tted with a suitable liner and contact tip.
Tread the ller wire into the welding gun and connect to the SuperSnake. Hand tighten the
gun collar.
NOTE! Kemppi manufacture a range of quality welding guns, low friction loss gun liners and gun
consumables, designed to compliment our welding products. Please consider these products
before selecting an alternative.
Welding power controls
Ensure Remote control function is selected on the wire feed unit. SuperSnake provides
wire feed speed and voltage control in Basic MIG/MAG mode, plus Power and Arc length in
1-MIG and Pulse MIG. Note that Pulse MIG is not available in ProMig applications. Convenient
welding parameter adjustments can be made during welding, allowing easy ne tuning of the
welding arc.
Meter display (not available in ProMig applications)
The meter display provides essential welding data indicators. Depending on the MIG/MAG
process selected, Voltage, Amperage, Wire feed speed, Plate thickness and Polarity will be
indicated. Power and arc length adjustment can be made, prior to, and during welding via the
potentiometers housed under the SuperSnake cabinet door. Post weld data is retained in the
display for approximately 30 seconds after welding stops, providing that no additional control
signals are received during this time.
1.2.
m/min
V
A
3.
1. Voltage
2. Welding current
3. Wire feed speed
EN
Water cooled models
Water cooled SuperSnake models allow connection to the cooling uid supply for liquid
cooled guns. Snap connectors tted at either end of SuperSnake unit are marked RED and
BLUE, allowing simple, fast and convenient connection. Ensure the cooling uid circuit is
correctly connected.
12
Setting the shielding gas
MMT 32
The shielding gas ow rate from the welding gun is set according to the application, weld
joint, gas type and gas nozzle shape and size. The ow rate should be measured at the
welding gun nozzle before welding via a Rotameter, and normally measure’s between 10 – 20
litres per minute for many welding applications.
20
15
10
5
l/min
NOTE! Handle shielding gas bottle with care. Assess the risks associated with handling and using
compressed gas. Always use a cylinder transport carriage and secure the cylinder safely.
When considering and planning routine maintenance, please consider the the frequency of
machine use and the working environment.
Correct operation of the machine and regular maintenance will help you avoid unnecessary
downtime and equipment failure.
NOTE! Disconnect the machine from the mains before handling the electrical cables.
4.1 DAILY MAINTENANCE
• Check the overall condition of SuperSnake and the welding gun. Remove welding
spatter from the contact tip and clean the gas nozzle. Replace worn or damaged parts.
Only use original Kemppi spare parts.
• Check the condition and connection of the welding circuit components: welding gun,
earth return cable and clamp, sockets and connectors.
• Check the condition of the feed rolls, needle bearings and shafts. Clean and lubricate
bearings and shafts with a small quantity of light machine oil if necessary. Assemble,
adjust and test function.
NOTE! Clean system with dry compressed air at least every 5 x wire spool changes. Keep sub feeder
Kemppi Service Workshops complete maintenance according to their Kemppi service
agreement.
Regular preventative maintenance by trained technicians will increase equipment life and
ensure reliable operation.
5. DISPOSAL OF THE MACHINE
Do not dispose of electrical equipment with normal waste!
In observance of European Directive 2002/96/EC on waste electrical and electronic
equipment, and its implementation in accordance with national law, electrical equipment
that has reached the end of its life must be collected separately and taken to an appropriate
environmentally responsible recycling facility.
The owner of the equipment is obliged to deliver a decommissioned unit to a regional
collection centre, per the instructions of local authorities or a Kemppi representative. By
applying this European Directive you will improve the environment and human health.
Box 717
S-194 27 UPPLANDS VÄSBY
SVERIGE
Tel +46 8 590 783 00
Telefax +46 8 590 823 94
sales.se@kemppi.com
KEMPPI NORGE A/S
Postboks 2151, Postterminalen
N-3103 TØNSBERG
NORGE
Tel +47 33 346000
Telefax +47 33 346010
sales.no@kemppi.com
KEMPPI DANMARK A/S
Literbuen 11
DK-2740 SKOVLUNDE
DANMARK
Tel +45 4494 1677
Telefax +45 4494 1536
sales.dk@kemppi.com
KEMPPI BENELUX B.V.
Postbus 5603
NL-4801 EA BREDA
NEDERLAND
Tel +31 765717750
Telefax +31 765716345
sales.nl@kemppi.com
KEMPPI (UK) Ltd
Martti Kemppi Building
Fraser Road
Priory Business Park
BEDFORD, MK44 3WH
UNITED KINGDOM
Tel +44 (0)845 6444201
Telefax +44 (0)845 6444202
sales.uk@kemppi.com
KEMPPI FRANCE S.A.S.
65 Avenue de la Couronne des Prés
78681 EPONE CEDEX
FRANCE
Tel +33 1 30 90 04 40
Telefax +33 1 30 90 04 45
sales.fr@kemppi.com
KEMPPI GmbH
Otto-Hahn-Straße 14
D-35510 BUTZBACH
DEUTSCHLAND
Tel +49 6033 88 020
Telefax +49 6033 72 528
sales.de@kemppi.com
KEMPPI SPÓŁKA Z O.O.
Ul. Borzymowska 32
03-565 WARSZAWA
POLAND
Tel +48 22 7816162
Telefax +48 22 7816505
info.pl@kemppi.com
LAKSHMI TOWERS
New No. 2/770,
First Main Road,
KAZURA Gardens,
Neelangarai,
CHENNAI - 600 041
TAMIL NADU
Tel +91-44-4567 1200
Telefax +91-44-4567 1234
sales.india@kemppi.com
www.kemppi.com
1923520
1110
Loading...