Kemper WKA 100 User Manual

WP BAKERYGROUP
WKA
Fully automatic water cooler 25.03.2008
Fully automatic water cooler
Description
Advantages
High output Flexible area of use Automatic filling level control
– time saving
Cold water removal at constant water temperature
– fast availability
Optimum heat transfer
– Spiral compressor in tank
Energy-saving insulation
– low heat loss – cost reduction
Remote call-up via WMD water mixing and dosing unit
– exact dosing
Cooling water removal via removal pump
– exact dosing
Equipment
– Pressure tank – Removal pump – Optical filling level display – Digital temperature display
WKA 1/1
Technical data
WKA 100 WKA 200 WKA 300 WKA 500 WKA 800
Connections Electric 1.7 KVA
at 3 × 400 V/50Hz
Water intake (connection) ¾” (at side) ¾“ (at side) 3/4” (at rear) 3/4” (at rear) 3/4” (at rear)
Cold water outlet (connection at
front)
Container overflow (connection) 1¼“ (at side) 1¼“ (at side) 1¼“ (at rear) 1¼“ (at rear) 1¼“ (at rear)
Dimensions (B x D x H) in cm 67 × 76 x 150 67 × 76 x 170 86 × 89 x 188 87 × 90 x 230 120 × 125 x 230
Cooling capacity of +18°C to +3°C at 30°C ambient temp.,
-2°C vaporization temp., 18°C water intake temp.
Volume of water container in litres 100 200 300 500 800
Cooling water Temperature adjustable with
preselector
Temperature precision in °C +/- 1 +/- 1 +/- 1 +/- 1 +/- 1
Coolant in kg 1 1.2 1.6 1.6 2.8
Air circulation in ccbm per h 2200 2200 2500 2500 5000
Noise level in dB A 64 64 68 68 dB 69
Removal pump Output in kW 0.33 0.33 0.5 0.5 0.5
Consumption in A 2.3 2.3 1.3 1.3 1.3
max. delivery pressure in bar 3.8 3.8 3.3 3.3 3.3
max. delivery height in m 30 30 25 25 25
max. ambient temperature in °C 43 43 43 43 43
max. water intake temperature in °C 30 30 30 30 30
Werner & Pfleiderer Lebensmitteltechnik GmbH . von-Raumer-Straße 8-18 . 91550 Dinkelsbühl . Germany
Fon +49 (0) 98 51-905-0 . Fax +49 (0) 98 51-905-342 . info@wp-l.de . www.wp-l.de
3/4” 3/4” 3/4” 3/4” 3/4”
100 litres per hour 130 litres per hour 280 litres per hour 280 litres per hour 450 litres per hour
+2°C to +25°C +2°C to +25°C +2°C to +25°C +2°C to +25°C +2°C to +25°C
2.3 KVA
at 3 × 400 V/50Hz
2.9 KVA
at 3 × 400 V/50Hz
2.9 KVA
at 3 × 400 V/50Hz
5.0 KVA
at 3 × 400 V/50Hz
All details non-binding. Subject to change in the course of technical progress. All rights reserved.