Congratulations and thank you for choosing our Electric
your new air conditioner a pleasure to use. Before you use
the air conditioner, we recommend that you read through
the entire user manual, which provides the description of
the air conditioner and its functions.
To avoid the risks that are always present when you use an
electrical appliance, it is important that the air conditioner
is installed correctly and that you read the safety instructions
carefully to avoid misuse and hazards.
We recommend that you keep this instruction booklet
for future reference and pass it on to any future owners.
fter unpacking the air conditioner please check it is not
A
damaged. If in doubt, do not use the air conditioner but
contact your local Electrolux Customer Care Centre.
Information on disposal for users
• Most of the packing materials are recyclable.
Please dispose of those materials through your local
recycling depot or by placing them in appropriate
collection containers.
• If you wish to discard this air conditioner, please contact
your local authorities and ask for the correct method
of disposal.
• This product contains refrigerant which must be
reclaimed by a licensed refrigeration mechanic before the
product can be disposed of.
refrigerant warning
This unit uses refrigerant R32 and must be disposed of
by a licensed refrigeration mechanic with knowledge of
appropriate gas reclamation methods.
Do not use means to accelerate defrosting or to clean,
other than those recommended by the manufacturer.
The appliance shall not be stored in a room with
continuously operating ignition sources. Do not pierce
or burn.
This appliance is designed and intended to be used in normal
domestic applications only.
Important information that may
impact your Manufacturer’s Warranty
Adherence to the directions for use in this manual is
extremely important for health and safety. Failure to
strictly adhere to the requirements in this manual may
result in personal injury, property damage and affect
your ability to make a claim under the Kelvinator
manufacturer’s warranty provided with your product.
Products must be used, installed and operated in
accordance with this manual. You may not be able to
claim on the Kelvinator manufacturer’s warranty in the
vent that your product fault is due to failure to adhere
e
this manual.
caution
• The air conditioner is not intended for use by y
children or i
• Young children should be supervised to ensure that they
do not play with the air conditioner.
• Contact an authorised installer for installation of this unit.
• Contact an authorised service technician for repair or
maintenance of this unit.
• If the power cord is to be replaced, replaceme
must be performed by authorised personnel only.
• Installation work must be performed in accordance
with the national wiring Standards by authorised
personnel only.
2 Contents Kelvinator Air Conditioning
oung
rmed persons without supervision.
Safety precautions
environmental tip
caution
• Contact an authorised service technician for repair or
maintenance of this unit.
• Contact a licensed installer for installation of this unit.
• The air conditioner is not intended for use by young
children or infirmed persons without supervision.
• Young children should be supervised to ensure that they
do not play with the air conditioner.
• This air conditioner must be installed in accordance with
AS/NZS 3000:2000 and your electricity suppliers rules.
• There are local council rules regarding maximum
allowable noise levels emitted by air conditioners.
• If the power cord is to be replaced, replacement work
shall be performed by authorised personnel only.
• Installation work must be performed in accordance with
the national wiring standards by authorised personnel
only. Wrong connection can cause overheating or fire.
Inside this manual you will find many helpful hints on how to
use and maintain your air conditioner properly.
Just a little preventative care on your part can save you
a great deal of time and money over the life of your air
conditioner. You'll find many answers to common problems
in the char t of troubleshooting tips. If you review the chart of
Troubleshooting Tips first, you may not need to call for service.
Meanings of symbols used in this manual are shown below:
warning
This symbol indicates information concerning your
personal safety
caution
This symbol indicates information on how to avoid
damaging the appliance
tips and information
This symbol indicates tips and information about
use of the appliance
This symbol indicates tips and information about
economical and ecological use of the appliance
This symbol indicates never to do this
This symbol indicates always do this
warning
Do not use means to accelerate the defrosting
process or to clean, other than those recommended
by the manufacturer.
Do not store the appliance in a room with continuously
operating ignition sources (for example open flames,
an operating electric heater or an operating gas
appliance with a continuously lit pilot flame).
Do not pierce or burn.
Be aware that the refrigerant may be odourless.
Connect with power properly.
Otherwise, it may cause elec tric shock or fire due to
excess heat generation.
Do not operate or stop the unit by switching on or
off the power.
It may cause electric shock or fire due to heat generation.
Do not damage or use an unspecified power cord.
It may cause electric shock or fire.
If the power cord is damaged, it must be replaced by
the manufacturer or an authorised service centre or a
similarly qualified person in order to avoid a hazard.
Do not modify power cord length or share the outlet
with other appliances.
It may cause electric shock or fire due to heat generation.
Do not operate with wet hands or in damp environment.
It may cause electric shock.
Do not direct airflow at room occupants only.
This could damage your health.
Always ensure effective earthing.
No earthing may cause electric shock.
Do not allow water to run into electric parts.
It may cause failure of machine or electric shock.
Always install circuit breaker and a dedicated
power circuit.
No installation may cause fire and electric shock.
Disconnect the power if strange sounds, smell,
or smoke comes from the unit.
It may cause fire and electric shock.
Do not use the socket if it is loose or damaged.
It may cause fire and electric shock.
Do not open the unit during operation.
It may cause electric shock.
Keep firearms away.
It may cause a fire.
Do not use the power cord close to heating appliances.
It may cause fire and electric shock.
Do not use the power cord near flammable gas or
combustibles, such as gasoline, benzene, thinner, etc.
It may cause an explosion or fire.
Ventilate room before operating air conditioner if
there is a gas leakage from another appliance.
It may cause explosion, fire and burns.
Do not disassemble or modify unit.
It may cause failure and electric shock.
Kelvinator Air Conditioning Impor tant safet y instructions 3
Safety precautions
Prior to Operation
caution
When the air filter is to be removed, do not touch the
metal parts of the unit.
It may cause an injury.
Do not clean the air conditioner with water.
Water may enter the unit and degrade the insulation.
It may cause an electric shock.
Ventilate the room well when used together with
a stove, etc.
An oxygen shor tage may occur.
Do not put a pet or house plant where it will be
exposed to direc t air flow.
This could injure the pet or plant.
Do not use for special purposes.
Do not use this air conditioner to preserve precision
devices, food, pets, plants, and art objects. It may
cause deterioration of quality, etc.
Stop operation and close the window in storm
or hurricane.
Operation with windows opened may cause wetting of
indoor and soaking of household furniture.
Hold the plug by the head of the power plug when
taking it out.
It may cause electric shock and damage.
Turn off the main power switch when not using
the unit for a long time.
It may cause failure of product or fire.
Do not place obstacles around air-inlets or inside
of air-outlet.
It may cause failure of appliance or accident.
Ensure that the installation bracket of the appliance is
not damaged due to prolonged exposure.
If bracket is damaged, there is concern of damage due
to falling of unit.
Always insert the filters securely. Clean filter once
every two weeks.
Operation without filters may cause failure.
Do not use strong detergent such as wax or
thinner but use a soft cloth.
Appearance may be deteriorated due to change
of product colour or scratching of its surface.
Do not place heavy object on the power cord and
ensure that the cord is not compressed.
There is danger of fire or electric shock.
Preparing for operation
1 Contact an authorised installation specialist for installation.
2 Plug in the power plug properly.
3 Do not use a damaged or non-standard power cord.
4 Do not share the same outlet with other appliances.
5 Do not use an extension cord.
6 Do not start/stop operation by plugging /unplugging
the power cord.
Usage
1 Exposure to direct airflow to occupants, pets or plants
for an extended period of time could be hazardous to
their health.
2 Due to the possibility of oxygen deficiency, ventilate
the room when used together with stoves or other
heating devices.
Cleaning and maintenance
1 Do not touch the metal parts of the unit when removing
the filter. Injuries can occur when handling sharp
metal edges.
2 Do not use water to clean inside the air conditioner.
Exposure to water can destroy the insulation, leading to
possible electric shock.
3 When cleaning the unit, first make sure that the power
and circuit breaker are turned off.
Operating temperature
Cooling Mode
Indoor
Max.Min.Max.Min.
32°C17°C
Heating Mode
IndoorOutdoor
Max.Min.Max.Min.
27°C10°C24°C-7°C
Note: Performance may be reduced outside of these
operating temperatures.
Outdoor
43°C17°C
If water enters the unit, turn the unit off and
disconnect the power, contact a qualified
service technician.
Use caution when unpacking and installing.
Sharp edges could cause injury.
Do not drink water drained from air conditioner.
It contains contaminants and could make you sick.
4 prior to operation/operating temperature Kelvinator Air Conditioning
CLOS
Unit parts idecation
Operating instructions
1 Front panel
2 Air lter
3 Frame
4 Cabinet
5 Air inlet grille (outdoor side)
6 Air outlet grille
7 Electronic control keypad
8 Power supply cord and plug
9 Remote control
123
Controls
The electronic control keypad will look like one of the
following:
Reverse Cycle Models
4
Cooling only models
5
6
7
8
9
1 Power cord conductors are distinguished according to
colour as follows (see Fig.1)
2 For your safety and protection, this unit is earthed
through the power cord (see Fig.2)
Please contact the manufacturer or its service agent or a
similar qualied person if you want to replace it.
3 Be sure that the unit is being correctly grounded. The
wall outlet (Air-Break Switch) should be provided with
reliable earth wire.
4 The unit should be provided with an individual circuit
an
d the circuit breaker/fuse rating should be the same as
that of the power cord and wall outlet.
Fig. 2
power
cord
Fig. 1
A
E
N
Vent control
The vent control is located above the control keypad.
The operation method is different on different models
(see the followin
For maximum cooling e
gures).
ciency, CLOSE the vent.
This will allow internal air circulation.
To open the vent, slide the lever to the left. To close it,
slide to the right.
closeopen
E OPEN
To open the vent, set the lever to the right position.
To close it, set the lever in the left position.
E- earthwire, yellow/green
N- neutral wire, blue
A - active wire, brown
wall outlet
air break switch
Kelvinator Air Conditioning unit parts iden cation/operation instructions 5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.