Kelvinator KSV80HRC, KSV70HRC, KSV70CRC, KSV62HRC, KSV53HRC Installation Manual

...
Inverter Split Room Air Conditioner
Installation Manual
KSV26CRC, KSV26HRC, KSV35CRC, KSV35HRC, KSV53HRC, KSV62HRC,
KSV70CRC, KSV70HRC, KSV80HRC
Refrigerant R410A
Congratulations and thank you for choosing our Inverter Split room air conditioner. We are sure you will find your new air conditioner a pleasure to use. Before you use the air conditioner, we recommend that you read through the entire user manual, which provides the description of the air conditioner and its functions.
To avoid the risks that are always present when you use an electrical appliance, it is important that the air conditioner is installed correctly and that you read the safety instructions carefully to avoid misuse and hazards.
We recommend that you keep this instruction booklet for future reference and pass it on to any future owners.
After unpacking the air conditioner please check it is not damaged. If in doubt, do not use the air conditioner but contact your local Electrolux Customer Care Centre.
environmental tip
Information on disposal for users
• Most of the packing materials are recyclable. Please dispose of those materials through your local recycling depot or by placing them in appropriate collection containers.
• If you wish to discard this air conditioner, please contact
your local authorities and ask for the correct method of disposal.
caution
• The air conditioner is not intended for use by young children or inrmed persons without supervision.
• Young children should be supervised to ensure that they do not play with the air conditioner.
• Contact an authorised installer for installation of this unit.
• Contact an authorised service technician for repair or maintenance of this unit.
• If the power cord is to be replaced, replacement work shall be performed by authorised personnel only.
• Installation work must be performed in accordance with the national wiring Standards by authorised personnel only.
Conditions of use
This appliance is intended to be used in household and similar applications such as:
Staff kitchen areas in shops, offices and other working environments
Farm houses
By clients in hotels, motels, and other residential
type environments
Bed and breakfast type environments
Contents ............................................................................ 2
Important safety instructions ........................................... 3
Notice for installation ....................................................... 3
Installation ......................................................................... 4
Installation drawing .......................................................... 5
Installation of indoor unit .................................................6
Refrigerant pipe connection .............................................8
Installation of outdoor unit ............................................... 9
Check after installation and operation test .................... 10
Installation and maintenance of HEPA filter ................... 10
Warranty .......................................................................... 11
Congratulations Contents
caution
1 The unit must only be installed by a qualified refrigeration
mechanic and electrical work carried out by a qualified electrician according to local or government regulations and in compliance with this manual.
2 If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
4 The appliance must be positioned so that the plug
is accessible.
5 The temperature of refrigerant circuit will be high,
please keep the interconnection cable away from the copper tube.
6 This appliance is not intended for use by persons
(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
warning
Before obtaining access to terminals, all supply circuits must be disconnected.
Please read this installation manual and the user manual before installation and store in a handy place for later reference. Inside you will find many helpful hints on how to install and test the air conditioner properly.
Electrical work must be carried out by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model to be installed.
Incorrect installation due to ignoring this instruction will cause harm or damage, and the seriousness is classified by the following indications.
Meanings of symbols used in this manual are shown below:
warning
This symbol indicates information concerning your personal safety
caution
This symbol indicates information on how to avoid damaging the appliance
tips and information
This symbol indicates tips and information about use of the appliance
environmental tip
This symbol indicates tips and information about economical and ecological use of the appliance
This symbol indicates never to do this
This symbol indicates always do this
Important safety instructions Notice for installation
Kelvinator Air Conditioning Important safety instructions/Notes for installation 3
4 Installation Kelvinator Air Conditioning
Safety precautions
1 A dedicated power supply circuit should be used for
products not supplied with a service cord and plug in accordance with local electrical safety regulations.
3 The unit must be reliably earthed and connected to
the special earth device by a qualified electrician.
4 The circuit breaker must have the functions of magnetic
tripping and heat tripping to prevent short circuit and overload.
5 The appliance must be installed in accordance with
national wiring regulations.
6 Including a circuit breaker with suitable capacity, please
note the following table.
Model Circuit Breaker (Amps)
KSV26CRC
10
KSV26HRC
10
KSV35CRC
10
KSV35HRC
10
KSV53HRC
15
KSV62HRC
15
KSV70CRC
20
KSV70HRC
20
KSV80HRC
20
Note:
• Make sure the live wire, neutral wire and earth wire in the power socket are properly connected.
• Inadequate or incorrect electrical connections may cause
electric shock or fire.
Earthing requirements
1 Air conditioner is type I electric appliance. Please ensure
the unit is reliably earthed.
2 The yellow-green wire in air conditioner is the earthing
wire which cannot be used for other purposes. Improper earthing may cause electric shock.
3 The earth resistance should adhere to the national
wiring regulation.
4 The user's power must have reliable earthing terminal.
Do not connect the earthing wire with the following:
1. Water pipe
2. Gas pipe
3. Contamination pipe
Installation
Installation site instructions
A proper installation site is vital for correct and efficient operation of the unit. Avoid the following sites where:
• strong heat sources, vapours, ammable gas or volatile
liquids are emitted.
• high-frequency electro-magnetic waves are generated
by radio equipment, welders or medical equipment.
• salt-laden air prevails (such as close to coastal areas).
• the air is contaminated with industrial vapours and oils.
• the air contains sulphurous gas such as in hot spring
zones.
• corrosion or poor air quality exists.
Installation site of indoor unit
1 The air inlet and outlet should be away from the
obstructions. Ensure the air can be blown through the whole room.
2 Select a site where the condensing water can be
easily drained out, and where it is easily connected for the outdoor unit.
3 Select a place where it is out of reach of children.
4 Select the place where the wall is strong enough to
withstand the full weight and vibration of the unit.
5 Be sure to leave enough space to allow access for routine
maintenance. The installation site should be 2m or more
above the oor.
6 Select a place about 1m or more away from a TV set or
any other electric appliance.
7 Select a place where the filter can be easily taken out.
8 Make sure that the indoor unit is installed in accordance
with installation dimension instructions (refer to page 5).
9 Do not use the unit in the laundry or by a swimming
pool etc.
Installation site of outdoor unit
1 Select a site where noise and outow air emitted by unit
will not annoy neighbors.
2 Select a site where there is sufficient ventilation.
3 Select a site where there is no obstruc tion blocking the
inlet and outlet.
4 The site should be able to withstand the full weight
and vibration of the unit.
5 Select a dry place, but do not expose the unit to direc t
sunlight or strong wind.
6 Make sure that the outdoor unit is installed in accordance
with the installation instructions, and is convenient for maintenance and repair.
7 Ensure that the height difference between indoor and
outdoor units complies with the table on page 8.