warning
Do not install yourself.
Incorrec t installation could c ause injury due to fire,
electric al shock, the unit fa lling or leakage of water.
Consult the d ealer from whom you purch ased the
unit or author ised installer.
Perform the in stallation secur ely referring to the
installation instruction.
Incorrec t installation could c ause a personal injur y
due to fire, elect ric shock, the unit f alling or leakage
of w ater.
Install the u nit securely in a plac e which can bear the
weight of the u nit.
If installed i n a structurally u nsound location, the u nit
could fall causing injury.
Perform ele ctrical work accord ing to the installatio n
manual and b e sure to use a dedicated ci rcuit.
If the capaci ty of the power circui t is insufficient or
there is incom plete electrical w ork, it could result in a
fire or an elect ric shock.
Use the speci fied wires to connec t the indoor and
outdoor uni ts. Securely atta ch the wires to the
terminal boa rd connecting sec tions so the stress of
the wire is not ap plied to the section s.
Incorrec t connection and fix ing could cause a fire.
Check that th e refrigerant gas do es not leak after
installatio n is complete.
Leak refriger ant could be a hazard to heal th and the
environment.
Unit may not per form to full capacit y and the life of
the unit may redu ce.
Be sure to use the pa rts provided or spe cified parts
for the insta llation work.
The use of defec tive parts cou ld cause an injury du e
to a fire, electr ic shock, the unit falli ng etc.
Perform the dr ainage/piping work acc ording to the
installation instruction.
If there is a defec t in the drainage/pip ing work, water
could leak from t he unit and household g oods could
get wet or be damag ed
Operating temperature
Cooling Mode
Indoor
Outdoor
Max. Min. Max. Min.
32°C 17°C
43°C 18°C
Heating Mode
Indoor Outdoor
Max. Min. Max. Min.
30°C 17°C 24°C -5°C
Note: Optimum performance will be achieved withi n these
operating temperatures.
Please read the user ma nual before installation and caref ully
store in a handy place fo r later reference. Inside you will
find many helpful hint s on how to install and test the air
conditioner properly.
Electrical w ork must be installed by a licen sed electrician.
Be sure to use the corre ct rating of the power plug and main
circuit for the mod el to be installed.
Incorrect in stallation due to ignoring this in struction will
cause harm or da mage, and the seriousness is cla ssified by
the following indications.
Meanings of symb ols used in this manual are shown belo w:
warning
This symbol indicates information concerning your
personal safety
caution
This symbol in dicates information on how to avoid
damaging the appliance
tips and information
This symbol in dicates tips and information a bout
use of the applia nce
environmental tip
This symbol in dicates tips and information a bout
economical and ecological use of the appliance
This symbol in dicates never to do this
This symbol in dicates always do this
Important safety instructions
2 Contents Kelvinator Air Conditioning
Congratulatio ns and thank you for choosing our Fixe d Speed
Split room air condi tioner. We are sure you will find
your new air conditio ner a pleasure to use. Before you use
the air conditione r, we recommend that yo u read through
the entire user man ual, which provides the descri ption of
the air conditioner and its functions.
To avoid the risks that are alway s present when you use an
electric al appliance, it is important t hat the air conditioner
is installed cor rectly and that you read the safe ty instructions
carefully to avoid misu se and hazards.
We recommend that you kee p this instruction book let
for future referenc e and pass it on to any future owner s.
After unpack ing the air conditioner please c heck it is not
damaged. If in doubt , do not use the air conditioner bu t
contact your l ocal Electrolux Custom er Care Centre.
environmental tip
Information on disposal for users
• Most of the packing materials are re cyclable.
Please dispose of t hose materials through your loca l
recycling dep ot or by placing them in appropriate
collection containers.
• If you wish to discard this air cond itioner, please contact
your local autho rities and ask for the correc t method
of disposal.
caution
• The air conditioner is not intend ed for use by young
children or infirmed persons without supervision.
• Young children shoul d be supervised to ensure tha t they
do not play with the air c onditioner.
• Contact an authorise d installer for installation of t his unit.
• Contact an authorise d service technician for repai r or
maintenance of this uni t.
• If the power cord is to be replaced, repla cement work
must be performed by authorised personnel only.
• Installation work must be p erformed in accordance
with the national w iring Standards by authorised
personnel only.
Conditions of use
This appliance is in tended to be useed in household an d
similar applications such as:
• Staff kitche n areas in shops, offices and othe r working
environments
• Farm houses
• By clients in hotels, m otels, and other residential
type environments
• Bed and breakfas t type environments
Safety precautions ............................................................3
Installa tion of the indoo r unit and outdoor unit ............... 5
Flaring work and connection of piping .............................9
Connecting the cable between indoor unit and
outdoor unit .................................................................... 13
Checking the drainage and forming the piping..............15
Air purging ...................................................................... 16
Test running.....................................................................18
Congratulations Contents
Kelvinator Air Conditioning Important safe ty instruc tions 3