Congratulations and thank you for choosing our Inverter split
system room air conditioner. We are sure you will find
your new air conditioner a pleasure to use. Before you use the air
conditioner, we recommend that you read through
the entire user manual, which provides the description of
the air conditioner and its functions.
To avoid the risks that are always present when you use an electrical
appliance, it is important that the air conditioner
is installed correctly and that you read the safety instructions
carefully to avoid misuse and hazards.
We recommend that you keep this instruction booklet
for future reference and pass it on to any future owners.
Conditions of use
This appliance is intended to be used in household and similar
applications such as :
• staff kitchen areas in shops, offices and other working
environments.
• farm houses.
• by clients in hotels, motels and other residential type
environments.
• bed and breakfast type environments.
This air conditioner is designed for and intended to be used in
normal domestic applications only.
Model number: ..................................................................................
Serial number: ...................................................................................
environment
Information on disposal for users
• Most of the packing materials are recyclable.
Please dispose of those materials through your local
recycling depot or by placing them in appropriate collection
containers.
• If you wish to discard this air conditioner, please contact your
local authorities and ask for the correct method
of disposal.
R32 refrigerant warning
This product uses R32 difluoromethane refrigerant, which is a
mildly flammable gas class 2.2 according to AS 1677 and must be
handled by a refrigeration mechanic with appropriate Australian
refrigerant handling licence.
Meanings of symbols used in this manual are shown below:
warning
This symbol indicates information concerning your personal safety
or information on how to avoid damaging the air conditioner
important
This symbol indicates tips and information about use of the
appliance
environment
This symbol indicates tips and information about economical and
ecological use of the appliance
important
• Contact an authorised installer for installation of this unit.
• Installation work must be performed in accordance with the
national wiring standards by authorised personnel only.
• This air conditioner may need to be installed on it's own
separate circuit. Please refer to AS/NZS3000 and local wiring
regulations for requirements.
• Contact an authorised service technician for repair or
maintenance of this unit.
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play
with the air conditioner.
• If the system is to be moved to another location or disposed
of, only a suitably qualified person is permitted to undertake
such work.
• Take care not to catch fingers on the fan blade when adjusting
vertical louvres.
• This air conditioner uses R32 refrigerant.
• Do not use this air conditioner for non-specified special
purposes ( e.g. preserving precision devices, food, pets, plants,
and art objects). Usage in such a manner could damage your
property.
• Always insert the filters securely. Clean the filters every
3 months, or as required.
warning
• Do not use means to accelerate the defrosting process or to
clean, other than those recommended by the manufacturer.
• Do not store the appliance in a room with continuously
operating ignition sources (for example open flames, an
operating electric heater or an operating gas appliance with a
continuously lit pilot flame).
• Do not pierce or burn any part of the air conditioner.
• Be aware that the refrigerant is odourless and any gas leak is
not detectable by smell.
• Ensure the unit is properly connected to the power. Excess
heat generation caused by incorrect connection may result in
an electric shock or fire.
• Do not operate or stop the unit by switching on or off at the
power source. This may cause an electric shock or fire due to
excess heat generation.
• Do not operate with wet hands or in damp environment. This
may cause an electric shock.
• Always ensure that the unit is correctly earthed.
No earthing may cause electric shock.
• Do not allow water to run into electric parts. It may cause
failure of the unit or electric shock.
• Use a correctly rated circuit breaker or fuse. There is risk of fire
or electric shock.
• Disconnect the power if strange sounds, smells,
or smoke come from the unit. It may cause fire and
electric shock.
• Do not drink water drained from the air conditioner. It may
contain contaminants that could make you sick.
• Do not open the unit during operation. It may cause
electric shock.
• Ventilate room before operating the air conditioner if there has
been or may have been a flammable gas leak from another
appliance. It may cause an explosion, fire and burns.
• Do not disassemble or modify unit. It may cause failure and
electric shock.
• When the air filter is to be removed, do not touch the metal
parts of the unit. It may cause an injury.
• Do not clean the air conditioner with water. Water may
enter the unit and degrade the insulation. It may cause
an electric shock.
• Ventilate the room well when used together with a stove
or other combustion heating device. An oxygen shortage
may occur.
• Exposure of direct airflow to occupants, pets or plants for an
extended period of time could be a health hazard.
Safety instructions
3
Safety instructions
WARNING
warning
• Do not place obstacles around air inlets or inside of
air outlet. It may cause failure of appliance or accident.
• Turn off at the main power switch if the unit will not be used for
a long period of time. It may cause failure of the unit or fire.
• Do not use strong chemical cleaners such as detergents,
abrasive cleaners or thinners, as they may damage the
appliance causing scratches, discolouration or deteriorate the
surface finish. Use a soft cloth for cleaning.
• Where the airconditioned is installed on an external wall
bracket ensure that the installation bracket of the outdoor
appliance is not damaged due to prolonged exposure. If
bracket is damaged, the unit may fall and damage may occur.
• Use caution when unpacking and installing. Sharp edges could
cause injury.
• If water enters the unit, turn the unit off and disconnect the
power, contact a qualified service technician.
Troubleshooting
You'll find many answers to common problems in the chart
of troubleshooting tips on page 21. If you review the chart of
Troubleshooting Tips first, you may not need to call for service.
Service
For repair and maintenance, contact your authorised
service dealer.
Refer to the contact numbers in the warranty section on the back
page of this manual.
4Important safety instructions
Installation drawing
Fig. 1
Before screwing the remote
controller holder to the wall,
make sure that control signals
are properly received by
indoor unit.
4
Installation plate ng screw
ST3.9x25(5)
Remote
control
5
6
2x AAA batteries
7
12cm or more
30cm or more
A
3
15cm or more
1
12cm or more
Air
ter
2
Air outlet
200cm or more
Additional drain pipe
Wrapping tape (wrap the
insulation pipe with the tape
from bottom to top)
60cm
or more
30cm or more
200cm or more
60cm or more
B
In sites with poor drainage, use block bases
for outdoor unit. Adjust its height until the
unit is leveled. Otherwise, water leakage or
pooling of water may occur.
Where there is a danger of the
unit falling, use foot bolts to
.
Allow two of A, B and
C directions to be free
C
from obstructions.
89
Seal
Drain elbow
Flare nuts
Air conditionerQty.Qty.
1
Indoor unit
2
Outdoor unit
3
Indoor unit mounting plate
4
Mounting plateg screws, ST3.9x255 or 8*
7
1
1
1
Battery (AAA 1.5V)
8
Drain elbow & seal1
9
Flare nuts2
10
Installation Manual1
2
5
Remote controller1
6
Remote controller holder
11
User manual1
1
* 9kW models have 8 screws, other models have 5 screws.
NOTE: Appearance of outdoor unit and indoor unit may differ from some models. The actual shape shall prevail.
5Installation drawing
WARNING
Remote control specicationsUsing the remote control
Rated voltage3.0V (2x 1.5V AAA)
Signal receiving range8m
Mode
ON/OFF
Fan/quiet
miT remiT
e
r
LED
Swing
Follow
me
Turbo
Direct
Short
cut
Self
clean
Location of the remote controller
• Use the remote controller within a distance of 8 meters from
the appliance, pointing it towards the receiver. Reception is
conrmed by a beep.
Mode
remiTremiT
LED
Turbo
ON/OFF
Sleep
Follow
me
Short
cut
Fan
Quiet
Swing
Direc t
Self
clean
caution
• The air conditioner will not operate if curtains, doors or other
materials block the signals from the remote controller to the
indoor unit.
• Prevent any liquid from falling into the remote controller. Do
not expose the remote controller to direct sunlight or heat.
• If the infrared signal receiver on the indoor unit is exposed to
direct sunlight, the air conditioner may not function properly.
• Use curtains to prevent the sunlight from falling on the receiver.
• If other electrical appliances react to the remote controller,
either move these appliances or consult your local dealer.
•Do not drop the remote controller. Handle with care.
not place heavy objects on the remote controller,
• Do
or step on it.
Location of the remote controller
• The remote controller can be attached to a wall or pillar by
using a remote controller holder .
• Before installing the remote controller, check that the air
conditioner receives the signals properly.
• Install the remote controller holder with two screws.
• For installing or removing the remote controller, move it up or
down in the holder.
6Remote control specications
Replacing batteries
The following cases signify exhausted batteries.
Replace old batteries with new ones.
• Receiving beep is not emitted when a signal is transmitted.
• Indicator fades away.
The remote controller is powered by two dry batteries (2x AAA
1.5V)housed in the back rear part and protected by a cover.
1. Remove the cover in the rear part of the remote controller.
2. Remove the old batteries and inser
the(+) and (-) ends correctly.
3. Put the cover back on.
NOTE: When the batteries are removed, the remote controller
erases all programming. After inserting new batteries, the remote
controller must be reprogrammed.
t the new batteries, placing
warning
• Do not mix old and new batteries or batteries of
different types.
• Do not leave the batteries in the remote controller if they are
not going to be used for 2 or 3 months.
• Do not dispose batteries as unsorted general waste. Collection
of such waste separately for special treatment
is necessary.
Indoor unit display
Digital display
• Displays the temperature settings when the air conditioner is
operational.
• Displays the room temperature in FAN mode.
• Displays the self-diagnostic codes.
• Displays '
or Quiet feature is activated.
• Displays '
• Displays '
feature is cancelled.
• Displays '
• Displays '
heating mode.
• Displays '
NOTE: For multi-split models, self clean operation will not
be available.
• Displays '
• Displays '
the manual start button 2 times within 5 seconds (refer page 16).
• If you want to turn off the indoor unit display (for example to
make the room dark for sleeping), press the LED button on the
remote control.
' for three seconds when Timer ON, Swing, Turbo
' for three seconds when Timer OFF is set.
' for three seconds when Swing, Turbo or Quiet
' under defrosting operation.
' when anti-cold air feature is activated under
' during self clean operation (if applicable).
' under 8°C heating operation.
' when forced cooling mode is activated by pressing
7Using the remote control
Operation of buttons
1
LED
remiTremiT
ON/OFF
Sleep
Follow
me
Short
cut
2
3
4
5
6
7
Mode
Turbo
Fan
Quiet
Swing
Direc t
Self
clean
1. ON/OFF Button
This button turns the air conditioner ON and OFF.
2. Mode Button
Press this button to modify the air conditioner mode in a
sequence of following:
AUTO > COOL > DRY > HEAT > FAN
NOTE: Please do not select HEAT mode if the machine you
purchased is cooling only type. Heat mode is not supported by
the cooling only appliance.
3. Timer Button
Press this button to initiate the auto-on/off time sequence. Each
press “+” or “-” will increase/decrease the auto-timed setting in
30 minute increments. When the setting time displays 10.0, each
8
press will increase/decrease the auto timed setting by 60 minute
increments. To cancel the auto-timed program, simply adjust the
auto-on/off time to 0.0h.
9
4. Sleep Button
• Active/Disable sleep function. It can maintain the most
comfortable temperature and save energy. This function
is available on COOL, HEAT or AUTO mode only.
8
• For the detail , see sleep operation on page 14.
NOTE: While the unit is running under Sleep mode, it will
be cancelled if MODE, FAN SPEED or ON/OFF button is
10
pressed.
5. LED Button
Disable/Active indoor screen Display. When pushing the
11
12
13
button, the indoor screen display is cleared, press it again to
light the display.
6. Follow me Button
Push this button to initiate the Follow Me feature, which
allows the indoor ambient temperature reading to be taken
from the remote control. The remote control will send this
signal to the air conditioner every 3 minutes interval until
press the Follow Me button again. The air-conditioner will
cancel the Follow Me Feature automatically if the indoor unit
dose not receive the signal from the remote control within a
7 minutes period.
7. Turbo Button
Active/Disable Turbo function. Turbo function enables the
unit to reach the preset temperature at cooling or heating
operation in the shortest time.
8Operation of buttons
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.