After 30 seconds electrical interference will be reduced.
3. Go Detecting!
Minelab is always interested in your opinions.
If you have any questions or comments
regarding the E-Trac or any other Minelab
product, please feel free to contact us directly
or via your local Authorised Minelab dealer.
For further product information
and detecting tips, refer to:
WWW.MINELAB.COM
Metal detecting is a fascinating and
rewarding activity enjoyed by people all over
the world. By getting to know your E-Trac
you can become one of the many successful
detectorists who combine their passion
for the outdoors with the excitement of
discovering valuable coins, relics, gold and
jewellery on a regular basis.
E-Trac is Minelab’s most technologically
advanced detector, incorporating the unique
Full Band Spectrum (FBS) Technology. Its
sleek, sturdy design, innovative control
panel, clear LCD, robust lightweight coil and
comprehensive targeting options set it apart
from any other detector available today.
E-Trac has taken a further ground breaking
step by incorporating a USB interface,
which will allow you to download and
upload E-Trac settings, User Modes and
Discrimination Patterns using your own
Personal Computer (PC).
E-Trac will locate valuable metal objects in
a variety of mineralized ground conditions,
including extremely salty soils, sea water,
wet beach sand and highly magnetic ground
conditions. New functionality allows you
to customise your E-Trac to your specific
requirements.
This manual is designed to help both the
beginner and expert treasure hunter obtain
the best performance with their E-Trac.
Minelab wishes you every success with
your E-Trac!
Page 4
2
3
Contents
Inside Front Cover
10
13
16
18
19
20
21
22
23
24
25
26
28
29
31
32
33
34
36
38
40
40
42
44
46
51
Quick Start
How Metal Detectors Work
4
The Technology of E-Trac
5
New Features
6
Assembly
7
Adjusting the Detector for Comfortable Detecting
Battery Packs
Introducing the Control Panel
Turning the Detector On
Reset
Discrimination
Smartfind™
Introducing the Detection Screens
Pattern Screen
Digital Screen
Depth
Layout Summary of the Detection Screens
Detecting Basics
A Simple Detecting Exercise
Noise Cancel
QuickMask™
Pinpoint
Main Menu
Menu Structure
E-Trac Modes
Mode Settings, Universal Settings and Preferences
User Modes Menu
Selecting and Saving
Discrimination Menu
Selecting and Saving
Edit Screen
Edit Modes
The Combine Function
54
Sensitivity Menu
55
Auto Sensitivity
56
Manual Sensitivity
57
Audio Menu
58
Threshold Level
60
Volume Limit
61
Volume Gain
62
Response
64
Tone ID
64
Number (No.) of Tones
65
Sounds
67
Variability
68
Limits
69
Threshold Pitch
Expert Menu
Recovery Deep and Recovery Fast
70
Trash Density
72
Ground
74
Manual Noise Cancel
75
Preferences Menu
Contrast
76
Pinpoint Mode
76
Show Sensitivity
78
Show Mode Info
78
Display Timeout
79
Master Reset
79
E-Trac Xchange
80
Technical Information
Technical Specifications
81
Factory Presets Table
82
Battery Performance
84
User Information
86
Recovering the Target
87
Treasure Locations
88
Accessories
89
Detector Care and Safety
90
Trouble Shooting
Warranty
91
Service and Repair Form
92
Item Number: 4901 - 0065
Revision: 1.1
Page 5
4
5
How Metal Detectors WorkThe Technology of E-Trac
Metal detectors create an electromagnetic
(EM) field around the coil, which penetrates
the ground. Because metal is conductive it
causes a change in this field. The detector
senses this change through the coil and
sends a signal back to the control box,
alerting the operator.
Metal detectors can determine the size, shape
and composition of metallic objects beneath
the coil. Typically, the larger the object, the
easier it is to detect.
A metal detector’s EM operating frequencies
are measured in kilohertz (kHz). Low
frequency EM fields (e.g. 1.5kHz) penetrate
the ground deeply, but sensitivity to smaller
targets is low. High frequency EM fields (e.g.
65kHz) have a shallower depth of penetration,
but sensitivity to small targets is high.
E-Trac’s multiple frequency operation provides
the advantage of both; good depth and
high sensitivity.
Full Band Spectrum (FBS)
Most detectors on the market operate on a
single or dual frequency, ranging from 1 to 70
kilohertz (kHz).
Although this technology has served the
industry well for years, Minelab found that
a frequency that worked well in one area
would often offer only marginal performance
when used in another location. Ground
mineralisation, trash content and target size
all had an effect on how effectively a
detector transmitting a single frequency
would operate.
FBS technology combines Minelab’s
multiple frequency BBS (Broad Band
Spectrum) technology with a powerful new
microprocessor to give:
• Greaterdetecting depth
• Highsensitivityoverawiderange
of targets
• Lessinterferencefromelectromagnetic
sources
• More accurate identicationoftarget
characteristics
Discrimination (Disc.)
Discrimination is the ability of a metal
detector to identify your desired targets (e.g.
coins and jewellery) and eliminate signals
from undesirable material (e.g. nails).
E-Trac can be programmed in a number
of ways to discriminate against unwanted
targets in different types of ground.
Ground Compensation
E-Trac uses a sophisticated approach to the
elimination of ground mineralisation. It uses
advanced digital filtering to eliminate the
influence of ground signals. This is achieved
automatically, allowing you to concentrate on
detecting targets.
FBS Comparison
Single Frequency
Dual Frequency
The FBS circuit automatically transmits
multiple frequencies simultaneously. This
increased frequency range means that the
signal received from the detector coil is
analysed from a wide range of responses.
This allows E-Trac to analyse more target
information so that the target identification
(ID) is more accurate.
Minelab’s unique FBS technology means
deep, sensitive, accurate detecting.
Multiple Frequency
Page 6
6
7
New Features
Assembly
Liquid Crystal Display (LCD)
E-Trac’s LCD has a viewing area of 72mm x
48mm and improved resolution compared
to previous Explorer models. This provides
clearer on-screen graphics and improved
target identification, making detecting with
E-Trac much easier.
Ergonomic Keypad Layout
The new keypad layout provides ergonomic,
single-handed access to all of E-Trac’s
functions and settings.
Ergonomic Handle Assembly
E-Trac’s new handle design gives you a
precisely balanced detector with a feel that
is distinctly different and unique to E-Trac.
This allows for excellent manoeuvrability with
firm control on both rapid and slow sweep
speeds and provides optimum comfort over
extended detecting periods. This also ensures
easy viewing of the LCD and access to the
keypad, allowing for quick assessment and
adjustment of settings.
New Menu
In combination with the new Keypad Layout,
the new Menu improves access to settings,
User Modes and Discrimination Patterns,
allowing quick and simple adjustments.
Auto Latch (Semi-Automatic
Discrimination Editing)
E-Trac now has an Auto Latch feature which
provides semi-automatic editing of your
Discrimination Pattern. In this editing mode,
the Edit Frame will automatically move
to the Ferrous (FE) and Conductivity (CO)
coordinates of the detected target. You can
then choose to accept or reject that target
from your Discrimination Pattern using the
Accept/Reject button.
QuickMask
QuickMask allows you to adjust the
Ferrous and Conductivity rejection levels
independently of the current Discrimination
Pattern, allowing a fast and simple way of
editing Patterns.
User Modes
A selection of preset User Modes allows
you to choose the best detector settings
and discrimination patterns for the ground
conditions. There are four pre-programmed
Minelab User Modes for you to choose
from, as well as slots for saving your own
personalised User Modes. All User Modes are
easily accessed via the Menu, allowing you to
quickly switch User Modes when required.
Suggested Sensitivity
When using Auto Sensitivity the E-Trac will
show your sensitivity selection as well as the
‘suggested’ sensitivity, as determined by the
detector, relative to ground conditions.
E-Trac Xchange
E-Trac Xchange allows you to download and
upload detector settings and Discrimination
Patterns via USB. This advanced feature
is designed to allow you to quickly
configure the E-Trac to particular detecting
environments and preferred targets.
Attaching the coil to the Lower Shaft:
Note: Before attaching the coil to the Lower
Shaft, remove the nut, bolt and washers
from the coil.
1 Plug the two rubber washers into the holes
on either side of the Lower Shaft.
2 Feed the coil cable up through the inside
of the Lower Shaft, ensuring the coil cable
appears out the top of the Lower Shaft.
3 Place the coil on a flat surface.
4 Slide the Lower Shaft into the bracket on
top of the coil. Ensure that the open side of
the Lower Shaft faces the ground.
5 Insert the bolt through the Lower Shaft and
the bracket on top of the coil.
6 Fasten with the nut provided, taking
care not to damage the thread of the
nut by over-tightening. This will need to
be loosened later to adjust the coil to a
comfortable detecting angle.
WARNING: The coil cable is directly
wired into the coil and is not removable.
Any attempt to remove this cable will
void your warranty.
Page 7
8
9
Assembly
Attaching the Lower Shaft to the
Upper Shaft:
1 Release the Upper Shaft camlock by pulling
the lever away from the shaft.
2 Feed the coil cable up through the inside
of the Upper Shaft, ensuring the camlock
side of the shaft is facing the ground.
3 Slide the Upper Shaft over the Lower Shaft,
so the coil cable appears out the top.
Connecting the Shaft Assembly to the
Handle Assembly:
1 Release the Control Box camlock by pulling
the lever away from the Control Box.
2 Align and push the coil cable connector
into the socket underneath the Control Box,
firmly tightening the retaining ring
to secure.
3 Push the Handle Assembly onto the Upper
Shaft, as far as it will go.
4 Lock the Control Box camlock by pushing
the lever flat onto the Control Box.
Attaching the Armrest Strap:
1 Clip both buckles onto the outer sides of
the armrest.
Attaching the Headphones:
1 Plug the headphone jack into the
headphone socket, located in the
rubber seal at the battery end of the
Handle Assembly.
The headphones may be plugged or
unplugged at any time.
Disconnecting the coil:
1 Reverse the steps in ‘Connecting the
Shaft Assembly to the Handle Assembly’,
‘Attaching the Lower Shaft to the Upper
Shaft’ and ‘Attaching the coil to the
Lower Shaft’.
2 Pull the coil cable out from inside the
lower shaft.
WARNING: Do not attempt to
completely remove the shaft assembly
while the coil cable is still connected to
the Control Box.
Page 8
10
11
Adjusting the Detector for
Comfortable Detecting
For comfortable detecting it is important to
take the time to adjust the detector correctly.
Holding the Detector
Thread your arm through the armrest and
strap. Grasp the handle of the detector and
rest your forearm in the armrest.
The correct position of the armrest should
allow you to comfortably grip the handle.
Your elbow should sit just above the back of
the armrest and the detector should feel like
an extension of your forearm.
Adjusting the Armrest Strap:
1 Loosen the strap by tilting the top edge
of the buckle out to release it from
the armrest.
2 Undo the Velcro and pull the buckle
outwards (towards yourself) to loosen
the strap.
3 Clip the buckle back into place and tighten
the strap until your arm is secure whilst in
the armrest. Re-attach the Velcro.
Adjusting the Length of the Shafts
A correct shaft length will allow you to
swing the coil over the ground without
uncomfortably stretching or stooping.
If the coil is too far from your body it will be
difficult to balance and manoeuvre
while detecting.
If the coil is too close to your body it may
detect your digging tools or any other
metal which you are carrying, causing
confusing sounds.
Adjusting the Position of the Armrest:
1 Use a screwdriver, or the edge of a coin,
to loosen the screw in the centre of the
armrest (turn counter-clockwise).
2 While holding the detector, slide the
armrest to sit just below your elbow.
3 Remove your arm. Tighten screw (turn
clockwise) to lock the armrest into position.
Adjust the lower shaft to the correct length,
securing the camlock to hold it in place.
A longer lower shaft is available for
tall people (p. 88).
Shaft is the
correct length
Shaft is too short
Page 9
12
13
Adjusting the Detector for
Comfortable Detecting
Adjusting the Angle of the Coil:
1 Loosen the bolt that connects the Lower
Shaft to the Coil. It should be loose
enough to allow the Coil to be moved for
adjustment, but tight enough that the Coil
can hold its position.
2 While holding the detector as if detecting,
lightly press the Coil to the ground until it
sits flat/parallel with the ground. The Coil
should remain parallel when lifting to the
sweep height, approximately 25mm (1”)
above the ground.
3 Tighten the bolt, but do not over-tighten it.
Battery Packs
E-Trac is supplied with two types of
battery pack.
One is a sealed rechargeable Nickel-Metal
Hydride (NiMH) battery pack. This comes with
a charger which plugs into a conventional
wall socket. The NiMH battery pack is
supplied discharged and needs to be charged
for 18 hours before operating the detector.
The other battery pack is a housing for eight
‘AA’ cell alkaline batteries.
Removing the Battery Pack from the
Battery Compartment:
1 Ensure that the detector is turned off
before removing the battery pack.
2 Rest the detector on a flat surface.
Disconnect the headphones.
3 Lift the rubber seal of the battery
compartment located at the end of the
handle assembly.
4 Raise the yellow tab to release the spring
loaded battery pack.
Note: Since there may be a variety of options
available for this detector, equipment may
vary according to the Model or items ordered
with your detector. Certain descriptions and
illustrations may also differ (in this manual) from
the exact Model that you purchased.
WARNING: Do not attempt to
disassemble the NiMH battery pack.
If disposing of battery pack, do not
incinerate. Contact your local authorities
to enquire about disposal or recycling
facilities.
5 Remove the battery pack entirely from the
battery compartment.
Note: Whenever the detector has been unused
for a lengthy period, recharge the battery pack
to ensure full performance.
Page 10
14
15
Battery Packs
Inserting the Battery Pack into the
Battery Compartment:
1 Lift the rubber seal of the handle assembly.
2 Slide the battery pack entirely into the
handle assembly, until it clicks into place.
3 Close the rubber seal, to close the battery
compartment.
Recharging NiMH Battery Pack with the
Mains Charger:
1 Remove the battery pack.
2 Insert the mains charger cable into the
socket at the tapered end of the
battery pack.
3 Plug the mains charger into the wall socket
and turn on the switch.
4 Leave for 18 hours to fully recharge. If the
battery was not completely discharged,
the charging time will be shorter. New
batteries will reach their full capacity after
several charge/discharge cycles.
5 Once charged, disconnect the battery
charger plug from the battery pack.
Note: It is normal for the tip of the
rechargeable battery to get warm
while charging.
Recharging NiMH Battery Pack with the
Car Charger:
1 Remove the battery pack.
2 Insert the car charger plug into the
accessories socket of your vehicle.
3 Insert the car charger plug into the socket
at the tapered end of the battery pack.
A small light on the car charger illuminates
indicating that the car charger is
in operation.
4 Leave for 18 hours to fully recharge. If the
battery was not completely discharged, the
charging time will be shorter.
5 Some vehicles may require the ignition to
be switched on to ‘Accessories’ for power to
be supplied to the charger.
6 Charging the battery for longer than 18
hours will not damage the NiMH battery
pack. However, it may gradually discharge
your car battery.
Note: The car charger is provided with a
fuse for short circuit protection. This can be
accessed by unscrewing the tip of the
charger plug.
Replacing ‘AA’ Batteries:
1 Slide the lid of the battery pack in the
direction of the arrow to open.
2 Place 8 x ‘AA’ cell alkaline batteries into the
battery pack ensuring that the + and –
terminals are aligned as indicated on
the label.
– Please note the following:
– Do not use rechargeable Lithium Ion
batteries with your E-Trac. They may
damage the detector and void your
warranty. Rechargeable Lithium Ion
batteries will give a combined voltage
above 13V and therefore cannot be used
with E-Trac. The detector has over-voltage
protection and will not turn on if the
battery voltage is too high.
– Do not leave drained AA batteries in the
detector as they can leak.
– The battery pack will not be damaged if
left on the charger for more than 18 hours.
– The battery chargers will not recharge
rechargeable alkaline or NiCad batteries.
3 Slide the battery pack lid closed until it
‘clicks’ into place.
High quality alkaline batteries are
recommended for optimum detection
time. Rechargeable alkaline, NiMH or
NiCad batteries may be used but must be
removed and recharged separately. Check
fitment of rechargeable batteries prior to
purchase, as some do not comply with
standard size requirements.
– Using a non-Minelab charger with the
battery pack may damage it and will void
the product warranty.
– Unlike Nickel Cadmium batteries, the NiMH
battery pack DOES NOT need to be drained
of all power before being recharged.
– Do not charge the battery at temperatures
above 45°C (113°F).
– Do not charge the battery at temperatures
below 0°C (32°F).
– Do not leave the battery exposed to very
hot conditions (e.g. on the dashboard or
rear parcel shelf of your car) or very
cold conditions.
Page 11
16
17
Introducing the Control Panel
Power
Pressing turns E-Trac On/Off.
Holding for three seconds resets the detector (p. 19)
to the Factory Preset settings, prior to startup.
Left Shift
Pressing in the Edit Screen changes the
Edit Frame Size (pp. 44–5).
Pressing in Combine inverses the selected
Discrimination Pattern (pp. 51–3).
Navigation Buttons
Used for adjusting settings in Detect Screens.
Also used in navigating the Menu. (Clockwise from
left: Left, Up, Right, Down.)
Backlight
Press to turn the Backlight On/Off. The Backlight
provides greater screen clarity in dim conditions. The
Backlight glows during the startup sequence. Turning
Off will extend battery life.
Right Shift
Pressing in the Edit Screen changes the
Edit Mode (pp. 44–5).
Pressing in Combine inverses the selected
Discrimination Pattern (pp. 51–3).
QuickMask
Press to access QuickMask, switching between
QuickMask (p. 32) and Detect screens (p. 22).
Noise Cancel
Starts the scan for the quietest operating frequency.
The scan takes 30 seconds (p. 31).
Menu
Used to access the Main Menu at any stage of
detector operation. This allows access to various
settings (pp. 34–7).
Pinpoint
Pressing turns Pinpoint On/Off . Pinpoint (p. 33)
assists in locating the exact position of a target prior
to recovery.
Accept/Reject
Pressing in the Detection Screens accepts or rejects
the detected target.
Pressing in the Menu takes you back one level.
Detect
Pressing, while in the Pattern Screen, will switch the
Detection Screen to Digital Screen, and vice versa if in
Digital. Pressing while in the Main Menu, QuickMask or
Edit Screen, returns to the Pattern/Digital Screen (pp.
23–4) at any stage of operation.
Page 12
18
19
Turning the Detector On
Reset
The Power button turns the detector On and
Off. Press the Power button once to turn
the detector On. The detector will begin its
startup with an animation and tune, after
which the Pattern Screen will appear and
E-Trac is ready to find treasure!
It is best to operate the detector only
when outdoors and away from sources of
electromagnetic interference (EMI) such as
power lines and phone towers. These
sources may cause the detector to perform
erratically, giving false signals and causing
inaccurate target ID.
There are also many metallic objects inside a
house, such as nails in the floor, reinforcing
in the walls, televisions and other household
appliances, that might overload the
electronics of the detector.
Overloading is not harmful to the electronics
of the detector. E-Trac is designed to
withstand coil overload.
Note: Sometimes it is possible that a large
object close to the coil will overload the
detector ’s electronics. When this happens,
E-Trac displays an Overload message and
emits a fading Overload sound which repeats
until the coil is moved away from the source of
the overload.
Each time you turn the detector On, the
last Detection Screen used before shutting
down will appear, e.g. if E-Trac was operating
in the Digital Screen when turned Off, then
the Digital Screen will appear when E-Trac is
turned back On.
To turn the detector Off, press the
Power button.
E-Trac is Factory Preset to allow you to start
detecting straight away. E-Trac’s Factory
Presets will respond to some low ferrous
metal targets such as silver coins and
jewellery, and ignore high ferrous targets
such as nails.
Any changes made to E-Trac’s settings are
saved automatically while detecting. These
settings will remain until they are changed, or
you instruct the detector to Reset to Factory
Presets, or Master Reset (p. 79).
When E-Trac is off, press and hold the Power
button for three seconds to turn the detector
on and ‘Reset’ it. Upon ‘Reset’, E-Trac loads
the Factory Preset User Mode and resets the
Universal Settings (p. 38).
User Modes and User Discrimination patterns
are not erased when the detector is ‘Reset’. All
settings within the Preferences Menu are only
reset if you use Master Reset (p. 79).
CAUTION: After turning E-Trac Off, allow
at least 1 second before turning E-Trac
back On. This will allow the detector to
save user settings into the memory so
they are not lost when the batteries
are removed.
To Reset the detector:
1 While the detector is switched Off,
press and hold the Power button for
three seconds.
A ‘Reset’ message will appear on the screen
and a tune will sound. After the startup is
complete the detector will be reset and
E-Trac is ready to detect again.
Page 13
20
21
Discrimination
Discrimination is the detector’s ability to
eliminate signals from undesired targets and
accept signals from desired targets. E-Trac’s
advanced signal processing rates detected
objects according to their conductivity and
ferrous characteristics. This enables you to
accept some types of targets and reject
others; the combination of these accepted
and rejected targets form a Smartfind
Discrimination Pattern.
Therefore, each coordinate of the Smartfind
Discrimination Pattern (visible in the Pattern,
Edit and QuickMask Screens) can be turned
white (clear) to accept, or black to reject,
certain targets. White areas of the Smartfind
Discrimination Pattern indicate particular
target coordinates that are accepted, black
areas indicate coordinates that are rejected.
The Pattern shown above is E-Trac’s Factory
Preset Coins Mode Discrimination Pattern,
which represents the typical characteristics
of nonferrous coins; a composite of hundreds
of coins from around the world. It accepts
signals from nonferrous targets and rejects
signals from most ferrous targets.
When an accepted target is detected (e.g.
matching the conductive and ferrous
characteristics of coins), the Target Crosshair
will appear in the white area and a target
response will be heard.
When a rejected target is detected (e.g.
not matching the conductive and ferrous
characteristics of coins), the Threshold will
blank and the Target Crosshair will remain in
the position of the last accepted target.
E-Trac offers a range of Smartfind
Discrimination Patterns (p. 42) which may be
used on their own or in combination.
Smartfind™
Smartfind is Minelab’s unique two
dimensional scale of discrimination. Smartfind
graphically represents both the FE-CO target
properties on the same display.
The horizontal axis rates the target on its size/
conductivity (CO), ranging 1–50 from left to
right. The vertical axis rates the extent of the
target’s ferrous characteristics (FE), ranging
1–35 from top to bottom.
A FE value of 1 represents low ferrous
characteristics and a value of 35 represents
high ferrous characteristics. Similarly, a CO
value of 1 represents low conductivity and 50
represents high conductivity.
1
1
Ferrous
35
As the coil passes over a target, the detector
digitally processes the target signals and
displays a Target Crosshair in the Smartfind
Window at the end of detection. The position
of the Target Crosshair is relative to the
target’s conductive and ferrous properties.
Conductivity
50
Ferrous targets (e.g. nails) contain a large
amount of iron, or some other less common
magnetic material. Because they are
magnetic, ferrous targets generally display
the Target Crosshair at the bottom of the
Smartfind Window.
Nonferrous targets (e.g. pure gold, silver,
copper and bronze) contain little or no
magnetic material. Because they are not
magnetic, nonferrous targets will generally
display the crosshair at the top of the
Smartfind Window.
Note: Even nonferrous targets will generate FE
values higher than 1.
High conductive targets (e.g. large silver
coins, copper items) will cause the Target
Crosshair to appear toward the right of the
Smartfind Window.
Low conductive targets (e.g. small alloy coins,
foil, 9ct and fine jewellery) will cause the
Target Crosshair to appear toward the left of
the Smartfind Window.
The object size will have some effect upon
the conductivity rating for targets. Generally,
the larger the target, the higher the
corresponding conductivity rating.
Page 14
22
23
Introducing the Detection ScreensPattern Screen
The E-Trac comes pre-programmed with
three unique Detection Screens. The selection
of the appropriate Detection Screen for
the current conditions will depend on your
preferences and experience. The three
Detection Screens are:
– Pattern
– Digital
– QuickMask
All the information required for detecting
targets is contained within these three
Detection Screens, and when combined
with audible target responses, no buried
treasure is safe.
Pattern
QuickMaskQuickMask
The Detect button on the Control Panel
switches between the Pattern and Digital
Screens, and returns you to these Screens if
you are in the Main Menu, QuickMask or Edit
Screen. In addition, the QuickMask button
provides a shortcut between the QuickMask
Screen and the Pattern/Digital Screens (see
diagram below).
The last Detection Screen used will appear
the next time you turn on the detector. Any
adjustments to Discrimination Patterns made
in the Pattern Screen will be retained and
used in Digital as well.
Detect
Digital
When the detector is turned on for the first
time, the Pattern Screen will be displayed
on the LCD and E-Trac is ready to begin
detecting. Target information is presented to
you via the Smartfind Discrimination Pattern,
Sensitivity Gauge, FE-CO numbers and Depth
Gauge. The information available to you in
the Pattern Screen is invaluable for successful
detecting with E-Trac.
Information is refreshed in ‘real time’; enabling
fast, clear and reliable interpretation of a
potential target’s qualities. With practice and
experience you will be better able to interpret
the information displayed, leading to more
successful detecting.
The Smartfind Window is in the centre of
the Pattern Screen. It displays the active
Discrimination Pattern (p. 21). Above the
Smartfind Window is the area in which
Discrimination Pattern
(Accepted)
The white (clear) area of
the Disc. Pattern is the
target FE-CO numbers
that you have accepted.
an accepted target’s FE-CO numbers will
appear. During and after a detection, a
Target Crosshair will appear in the Smartfind
Window, displaying the target’s FE-CO
coordinates relative to the rest of the
Discrimination Pattern. The FE-CO numbers
and Target Crosshair will remain until a new
‘accepted’ target is detected. Display Timeout
(p. 79), in the Preferences Menu, can be
turned on and this will clear detection results
after a five seconds.
The Depth Gauge is located to the right of
the Discrimination Pattern.
The Sensitivity Gauge is to the left, and by
default it is turned on. The Sensitivity Gauge
can be turned off via the Preferences
Menu (p. 78).
Ferrous-Conductivity
Numbers
The area where FE-CO
numbers of an accepted
target are displayed.
DetectDetect
QuickMask
– This dialogue box (p. 37) will appear, allowing you to confirm whether or not you wish to
load the QuickMask Discrimination Pattern into either the Pattern or Digital Screen.
Auto Sensitivity Gauge
The left bar, and the
number at the top, is
the user-set Sensitivity.
The right bar is the
‘suggested’ Sensitivity.
Discrimination Pattern
(Rejected)
The black area of the
Disc. Pattern is the target
FE-CO numbers that you
have rejected.
Depth Gauge
Represents the
approximate depth of
a target beneath the
coil. The range, from top
to bottom, is 0–30cm
(0–12”).
Page 15
24
25
Digital Screen
Depth
E-Trac has the Digital Screen that shows both
the ferrous content (FE; range 1–35) and the
conductivity (CO; range 1–50) of a target.
The enlarged FE and CO numbers are the
coordinates of the Target Crosshair displayed
in the Smartfind Discrimination Pattern.
There is a thumbnail of the active
Discrimination Pattern above the
FE-CO numbers.
Discrimination Pattern
Thumbnail
A small image of the
current Discrimination
Pattern.
To switch between Smartfind and Pattern
displays, press the Detect button. The
conductivity and ferrous information of
the target will clear as you switch between
Pattern and Digital, until a new
detection is made.
Note: When using the Digital Screen, the
Discrimination Pattern is still active.
The Depth Gauge, visible in the Pattern,
Digital and QuickMask Screens, indicates the
approximate depth of a detected target. The
top of the indicator represents the position
of the coil and the bottom represents
approximately 30cm (12“) from the coil.
Before DetectionAfter Detection
Once a target is detected, a crosshair will
appear in the Depth Gauge indicating the
approximate depth of the target.
The Depth Gauge is also updated for
rejected targets.
Before DetectionAfter Detection
Ferrous-Conductivity
Numbers
The area where enlarged
FE-CO numbers of an
accepted target are
displayed.
Page 16
26
27
Layout Summary of the Detection Screens
When the detector is turned On for the first
time, the Pattern Screen will appear on the
LCD and E-Trac is ready to begin detecting.
Minelab User Mode
The Minelab logo
is displayed when a
Minelab User Mode is
selected (pp. 38–41).
USB Icon
Displayed when the
detector is connected
to a PC via a USB cable
(p. 80).
Battery Icon
Indicates the present
battery charge available.
The Battery Icon will flash
when the battery is low
(pp. 84–5)
Backlight Icon
Displayed when the
Backlight is On.
Target information is presented via visual and
audio prompts. An introduction to the most
common elements of the Detection Screens
is below:
User Mode Number
A boxed number
specifies which User
Mode is being used (pp.
38–41).
Manual Sensitivity
Gauge
The left bar, and the
number at the top, is
the user-set Sensitivity.
The right bar is the
‘suggested’ Sensitivity
(pp. 54–6).
User Mode Modified
The flag icon is displayed
when a User Mode has
been modified but not
saved (pp. 38–41).
Accept Icon
Notifies you that you
have used the Accept/
Reject button to accept
the detected target’s
coordinates.
Auto Sensitivity
Animation
Displayed when Auto
Sensitivity is operating
(pp 54–6).
Ferrous-Conductivity
Numbers
The area where FE-CO
numbers of an accepted
target are displayed (p.
21).
Auto Sensitivity Gauge
The left bar, and the
number at the top, is
the user-set Sensitivity.
The right bar is the
‘suggested’ Sensitivity
(pp. 54–6).
My User Mode Icon
This icon is displayed
when one of your User
Modes is selected (pp.
38–41).
Reject Icon
Notifies you that you
have used the Accept/
Reject button to reject
the detected target’s
coordinates.
Depth Gauge
Represents the
approximate depth of
a target beneath the
coil. The range, from top
to bottom, is 0–30cm
(0–12”) (p. 25).
Target Crosshair
Will appear when an
accepted target is
detected, indicating the
Ferrous and Conductivity
coordinates of that target
(p. 21).
Page 17
28
29
A Simple Detecting ExerciseDetecting Basics
Sweeping the Coil
You will obtain the best performance
when the coil is swept close and parallel
to the ground at all times. This will increase
detection depth and improve the response to
small objects. Avoid excessive brushing of the
coil on the ground. Though the coil assembly
is rigid and durable, sudden jolts or bangs
can cause random signals and inaccurate
target IDs. Careful sweeping will ensure the
coil performs to an optimum level at all times.
Practise sweeping the coil over the ground
in a side-to-side motion while slowly walking
forward at the end of each sweep. Slightly
overlap the previous sweep to ensure full
ground coverage. An average sweep speed is
four seconds from left to right to left.
Targets
Metal objects are referred to as targets.
Targets are comprised of ferrous and
nonferrous metals. Ferrous metals are those
containing iron; such as steel, nails and some
types of coins.
Nonferrous metals are those which are not
magnetic, such as gold, silver, copper, bronze
and aluminium.
Before attempting to recover real targets, it is
important to understand how to interpret the
audio and visual signals of the detector.
Gather a collection of different metal objects,
e.g. various coins, gold and silver jewellery, a
nail, pull-tab, brass button and aluminium foil.
Take the detector outdoors, away from known
sources of EMI and metal objects.
Lay objects in a line, sufficiently spaced apart
to allow the coil to pass between them, as
shown below.
Detector Sounds
Turn the detector On.
The constant background ‘hum’ produced
by the detector is called the Threshold (pp.
58–9). Variations in the Threshold allow you
to hear very small and deep targets. It is also
used to help distinguish between desired and
undesired targets.
The detector may also produce False Signals
(Noise) when not over the ground or with the
coil held motionless. These may not be target
signals, but surrounding electromagnetic
interference (EMI). You can minimise these
False Signals by performing a Noise Cancel
(p. 31), or by reducing the Sensitivity (pp.
54–6) of the detector. It is generally better to
try to reduce False Signals by adjusting Noise
Cancel before resorting to reducing
the Sensitivity.
Sweep the coil across the targets one at
a time. Observe the LCD and listen to the
sounds of the detector as it passes over
each object. Although the LCD will give you
detailed information about the target ID, it is
important to pay attention to the difference
in audio response between each of
the objects.
Note: If you are getting signals from a
visibly clear patch of ground, there could be
buried metal objects. Try finding another
area to practise.
CAUTION: Incorrect coil sweeping can
generate false signals or miss targets.
You may wish to find a range of both ferrous
and nonferrous targets.
Examples of common targets:
Desired high ferrous target – war relic
Undesired high ferrous target – iron nail
Desired nonferrous target – gold coin
Undesired nonferrous target – pull-tab
NailPull-TabFoilCoinsJewellery
Page 18
30
31
A Simple Detecting ExerciseNoise Cancel
Detector Sounds (cont)
The Target Response is the sound produced
by the detector when a target is detected
and not ‘rejected’. A highly conductive target
(e.g. a large silver coin) will generally produce
a high-pitched tone and a low conductive
target (e.g. foil) will generally produce a lowpitched tone. Large targets or targets close to
the ground surface emit louder signals (p. 57).
When a ‘rejected’ target is detected, the
Threshold ‘blanks’ (becomes silent), indicating
that a target is located underneath the coil,
but has been rejected by the Discrimination Pattern (p. 20). Blanking is a useful way
of distinguishing between desired and
undesired targets.
Note: As the coil passes over the nail, the
Threshold ‘hum’ momentarily
disappears (blanks).
Target Response
Threshold
‘Blanking’ (No Sound)
Threshold
Large objects close to the coil may Overload
the detectors electronics. When this happens,
E-Trac displays an Overload message and
emits a fading Overload sound which repeats
until the coil is moved away from the source
of the overload.
Overloading is not harmful to the electronics
of the detector.
It is important to understand the sounds
produced when you make a valid or invalid
button press. You will usually encounter these
sounds while adjusting settings via the Main
Menu. A valid button press makes a “bip”
sound, an invalid button press makes a
“ba-dump” sound.
The E-Trac may become noisy due to
electrical interference from power lines,
electrical equipment or other detectors
operating close by. The detector interprets
this interference as inconsistent, short beeps
and erratic movement of the Target Crosshair
in the Smartfind window, or erratic changing
of FE-CO numbers in the Digital display.
Noise Cancel is used to minimise interference
in the current environment. The channel can
be changed automatically by pressing the
Noise Cancel button or manually in the Noise
Cancel setting via the Expert Menu (p. 75).
Automatic Noise Cancel
The Noise Cancel button instructs the
detector to automatically listen to every
channel and select the channel with the
least interference. Automatic Noise Cancel
may take up to 30 seconds. The detector
will display the progress on the LCD display
and a tune will sound at the end of this
period. After the Noise Cancel is complete
the chosen channel will be displayed
momentarily and then the detector will
resume normal operation.
To initiate an Automatic Noise Cancel:
1 Hold the detector 30cm (12”) above the
ground and make sure there are no large
targets or obvious sources of EMI close by.
30cm
(12”)
2 Press the Noise Cancel button. Keep
the detector 30cm (12”) above the
ground and completely still during the
automatic channel selection.
Note: This may take up to 30 seconds.
Page 19
32
33
QuickMask™
Pinpoint
QuickMask allows you to adjust the
level of Ferrous and Conductivity rejection,
independent of the Pattern/Digital Smartfind
Discrimination Pattern.
QuickMask is a useful tool for checking
accepted/rejected targets with an extra
Discrimination Pattern, without needing
to load or edit the current Pattern/Digital
Smartfind Discrimination Pattern.
QuickMask has two slider controls to adjust
the level of Ferrous and Conductivity
discrimination. The level of Ferrous
discrimination can be adjusted using the Up
and Down Navigation buttons, located on
the control panel. The level of Conductivity
discrimination can be adjusted using the Left
and Right Navigation buttons, also located on
the control panel.
In QuickMask the default setting for Ferrous
(FE) is ‘All Metal’, and ‘0’ for Conductivity
(CO). This makes the QuickMask an ‘All Metal’
Discrimination Pattern, which means that you
can quickly press the QuickMask button to
accept target signals from all types of metal.
Note: Adjusting the QuickMask Pattern does not
alter the Smartfind Discrimination Pattern.
The QuickMask Discrimination Pattern can
be loaded into the Pattern/Digital Smartfind
Window by pressing the Detect button.
Conductivity
Adjustment
The horizontal
adjustment of
Conductivity rejection.
Range: 1–50 (left to right)
Pinpoint assists you in locating the exact
position of a detected target.
Normally E-Trac is a ‘motion’ detector; it must
be moving over a target in order to detect it.
When Pinpoint is activated, E-Trac will operate
as a non-motion detector; it will produce a
constant audio response while the coil is held
stationary over a target. Pinpoint instructs
the detector to temporarily disengage
Discrimination Patterns. Therefore, all targets
will be detected if underneath the coil.
Detection results, such as FE-CO coordinates
and Depth, are still updated. Pinpoint may
be activated in either the Pattern, Digital or
QuickMask screens.
When Pinpoint is activated, a gauge will
appear near the top of the detection screen.
This gauge will move from the outsides to
the centre as the coil is moved closer to the
target. The Crosshair will darken when the
target is directly under the coil.
The audio response to the target will also
change; both pitch and volume will increase
as the coil approaches the target. The pitch
will increase as the strength of the signal
increases, and the volume will increase as the
coil moves closer to the target.
Note: Refer to pp. 76–7 for more information on
Pinpoint and Pinpoint Modes.
Pinpointing the Target:
1 Once the approximate target location is
known, move the coil to one side of that
location and press Pinpoint.
2 Sweep the coil slowly over the
target location.
Note: Keep the coil parallel to the ground
while Pinpointing.
3 Taking note of the response, reduce the
span of each successive pass of the coil
until you are confident of the location
of the target. Make a mental note of the
position, or mark a line on the soil with
your shoe or a digging tool.
4 Move to one side so that you can pass the
coil over the target at right angles to your
initial direction.
5 Repeating the above steps in the new
direction will give an exact location to dig.
Ferrous Adjustment
The vertical adjustment
of Ferrous rejection.
Range: 1–35, All Metal (top
to bottom)
QuickMask
Discrimination Pattern
The FE-CO settings create
a Discrimination Pattern
that can be accessed by
pressing the QuickMask
button.
Page 20
34
35
Main Menu
The Main Menu provides you with access
to all of E-Trac’s functions and settings. By
pressing the Menu button at any time the
Main Menu will be displayed on the LCD.
The Main Menu allows you to browse
through the each of the Menus. These are:
– User Modes
– Discrimination
– Sensitivity
– Audio
– Expert
– Preferences
By using the Left and Right Navigation
buttons you can scroll across each of
the Menus.
Each Menu appears below the Main Menu
and the settings of that Menu can be selected
and modified. Using the Down Navigation
button scrolls throughout the settings under
each Menu. If a desired setting is selected,
you can press the Left and Right Navigation
buttons to adjust the setting. Upon reaching
the maximum or minimum value of a setting,
you will hear an invalid button press sound if
you try to adjust further.
Some settings have a sub-Menu, e.g. Tone ID,
that are entered by using the Left or Right
Navigation buttons. You may navigate and
adjust settings in these sub-Menus the same
way you would in the Menus.
After making any adjustments or viewing
what value a setting is, you can press the
Accept/Reject button to navigate back a step;
the Menu button to return to the Main Menu;
or the Detect button to return to detecting.
Any adjustments to settings are saved
automatically, unless a dialogue box prompts
you to save.
Page 21
36
37
Menu Structure
Dialogue Boxes
When you perform certain functions with
E-Trac a dialogue box may appear asking you
to confirm the adjustment you are making.
Below is an example of a dialogue box.
The three possible selections that can be
made in a dialogue box are:
Ye s – This confirms that the adjustment you
have made will be applied.
No – This denies the adjustment you have
made and subsequent application.
Cancel – This denies the adjustment you
have made and returns you to the screen/
setting you were making adjustments in.
Note: At times you may not be presented with
all three of the above options, however, those
that are present will behave as has
been described.
Page 22
38
39
E-Trac Modes
Mode Settings, Universal Settings
and Preferences
E-Trac’s settings can be divided into three
categories: Mode Settings, Universal Settings
and Preferences. The significance of each
category is explained below.
Mode Settings
These settings define E-Trac’s performance
for a particular location (such as the beach
or park) or type of treasure hunting (such as
coins or relics). E-Trac is designed to allow you
to save these Mode Settings as a User Mode.
A User Mode can be saved in, or retrieved
from, E-Trac memory; or shared with another
user via E-Trac Xchange (p. 80).
Universal Settings
These settings affect E-Trac’s performance but
can be adjusted regardless of your location
and desired treasure type. Universal Settings
are determined according to your personal
detecting choices (e.g. Sensitivity, Noise
Cancel and Threshold Pitch).
Preferences
These settings do not affect E-Trac’s
performance and allow you to customize the
appearance of the Detection Screens (e.g.
Contrast and Show Sensitivity).
User Modes
A User Mode is a collection of specific
detector settings and a Discrimination
Pattern. The following settings are part of a
User Mode:
– Audio – Volume Gain
– Audio – Response
– Audio – Tone ID – No. of Tones
– Audio – Tone ID – Sounds
– Audio – Tone ID – Variability
– Audio – Tone ID – Limits
– Expert – Recovery Deep
– Expert – Recovery Fast
– Expert – Trash Density
– Expert – Ground
E-Trac is pre-programmed with four Minelab
User Modes: Coins Mode, High Trash Mode,
Beach Mode and Relics Mode.
The Coins Mode is the default User Mode,
and will be active when you first turn on your
E-Trac, or after a Reset (p. 19) and/or a
Master Reset (p. 79).
A User Mode can be loaded, modified, and
saved in E-Trac’s memory in one of the four
memory slots as either My Mode 1, My Mode
2, My Mode 3 or My Mode 4 (pp. 40–1).
If Show Mode Info (p. 78) is turned on, E-Trac
will display the Mode Information icons in
the Detection Screens (pp. 26–7) to show the
current User Mode.
Mode Information Icons
Minelab Coins Mode is selected
Minelab High Trash Mode is selected
Minelab Beach Mode is selected
Minelab Relics Mode is selected
My Mode 1 is selected
My Mode 2 is selected
My Mode 3 is selected
My Mode 4 is selected
If one of the Mode Settings or the
Discrimination Pattern is modified, the
icon will indicate the User Mode has been
modified but not saved.
Note: You can load a User Mode and adjust its
settings and the Disc. Pattern. If the User Mode
is not saved, the changes to the Disc. Pattern
and settings will be lost if another User Mode
is loaded.
User Modes can be exchanged between
E-Trac owners using E-Trac Xchange (p. 80).
Universal Settings
Universal Settings affect E-Trac’s performance
but are not saved as part of a User Mode.
Note: When a new User Mode is selected
Universal Settings do not change.
Universal Settings are returned to their
Factory Preset values if you Reset (p. 19) or
Master Reset (p. 79) the detector.
Universal Settings can be exchanged between
E-Trac users by using E-Trac Xchange (p. 80).
Preferences
Preferences do not affect E-Trac’s performance
and are not saved as part of a User Mode:
– Contrast
– Pinpoint Mode
– Show Sensitivity
– Show Mode Info
– Display Timeout
Note: When a new User Mode is selected
Preferences do not change.
Preferences are not altered if you Reset (p. 19)
the detector. Preferences are returned to their
Factory Preset values if you Master Reset (p.
79) the detector.
Sensitivity
Sensitivity
Manual Level
Auto Level
Audio
Threshold Level
Volume Limit
Volume Gain
Response
Tone ID
No. of Tones
Sounds
Variability
Limits
Threshold Pitch
Expert
Recovery Deep
Recovery Fast
Trash Density
Ground
Noise Cancel
Preferences
Contrast
Pinpoint Mode
Show Sensitivity
Show Mode Info
Display Timeout
Universal SettingsMode SettingsPreferences
Page 23
40
41
User Modes Menu
A User Mode is a collection of preset detector
settings and a Discrimination Pattern. E-Trac
comes with four Minelab User Modes and
space for you to save your own User Modes.
The Minelab User Modes are:
– Coins
– High Trash
– Beach
– Relics
If a Minelab User Mode is selected then the
Minelab logo and the User Mode Number
will appear at the top right of the Detection
Screens. If a My User Mode is selected then
the My User icon will appear instead of the
Minelab logo.
Minelab User Mode
User Mode Number
If any changes are made to E-Trac’s settings
you are able to save those settings to the
current User Mode via the User Mode Menu.
A small flag will appear in the top right
window of the Detection Screens if a User
Mode has been modified, but not yet saved.
The Show Mode Info (p. 78) setting must be
turned On via the Preferences Menu in order
to see any of these icons displayed in the
Detection Screens.
My User Mode
User Mode Modified
Selecting and Saving User Modes
Within the User Modes Menu there are two
options; Select and Save. If you choose Select,
the Menu will display the list of available
User Modes. A thumbnail of the associated
Discrimination Pattern is also displayed next
to the name of the User Mode.
If you select Save, from the User Mode Menu,
you can either select an empty slot to save
your User Mode in, or overwrite an existing
User Mode.
To Select a Minelab User Mode:
1 Press the Menu button
2 Scroll across to User Modes (using the Right
or Left Navigation button)
3 Scroll down to Select (using the Down
Navigation button)
4 Press either the Left or Right Navigation
button to enter the Select list of
User Modes
5 Scroll down to Minelab Modes and press
the Left or Right Navigation button to enter
Minelab Modes
6 Scroll down to the desired Minelab Mode
and press the Detect button to load
7 A dialogue box will appear asking you
to confirm the load. Use the Navigation
buttons to highlight ‘Yes’ and press either
the Left or Right Navigation button to
confirm. The User Mode is now loaded and
E-Trac is back to the Pattern/Digital Screen
To Select a User Mode:
1 Press the Menu button
2 Scroll across to User Modes (using the Right
or Left Navigation button)
3 Scroll down to Select (using the Down
Navigation button)
4 Press either the Left or Right Navigation
button to enter the Select list of
User Modes
5 Scroll down to the desired User Mode and
press the Detect button to load
Note: You can only select a User Mode that
does not have an in the Disc. Pattern
thumbnail
6 A dialogue box will appear asking you
to confirm the load. Use the Navigation
Buttons to highlight ‘Yes’ and press either
the Left or Right Navigation Button to
confirm. The User Mode is now loaded and
E-Trac is back to the Pattern/Digital Screen
Selecting a new User Mode, or initiating a Reset (p.19) or Master
Reset (p. 79), will alter the detector’s Mode Settings (pp. 38–9)
and the Discrimination Pattern. If you wish to keep the current
CAUTION
settings and Discrimination Pattern, you must save them first as
a User Mode.
To Save a User Mode:
1 Press the Menu button
2 Scroll across to User Modes (using the Right
or Left Navigation button)
3 Scroll down to Save (using the Down
Navigation button)
4 Press either the Left or Right Navigation
button to enter the Save menu
5 Scroll down to an empty slot, or a User
Mode you wish to overwrite, and press
either the Left or Right Navigation button
to Save the User Mode to that slot
The Save icon will notify you that the
User Mode has been saved to that slot and
a thumbnail of the Disc. Pattern will also
replace the or existing thumbnail.
Note: A Minelab User Mode can not be
overwritten.
6 Press the Detect button to exit the Menu
and resume detecting
Page 24
42
43
Discrimination Menu
The Discrimination Menu allows you to
Select, Save, Edit and Combine
Discrimination Patterns.
Note: All Discrimination Patterns preprogrammed into E-Trac are ‘accepting’ Disc.
Patterns. For example, the Iron Disc. Pattern
accepts iron.
Selecting a Discrimination Pattern
In the Select sub-Menu you will find a list of
all available Discrimination Patterns:
– 6 user patterns (My Pattern 1–6)
– The current QuickMask Disc. Pattern
– 4 patterns that are attached to your User
Modes (e.g. My Mode 1
– 10 pre-programmed patterns (All Metal,
Coins, Foil, etc.)
– 4 patterns that are attached to Minelab
User Modes (e.g. Coins Mode)
You can select any one of these patterns and
load it into either the Pattern/Digital Screen
or QuickMask.
E-Trac comes pre-programmed with 10
Discrimination Patterns. These patterns are:
– All Metal – Crown Caps
– Coins – Screw Caps
– Jewellery – Nails
– Foil – Iron
– Pull Tabs – Fe Coins
You can scroll through the list until you
find your desired Discrimination Pattern. A
thumbnail accompanies each Discrimination
Pattern name, so that you may see the
different characteristics of each
Discrimination Pattern.
There are also 10 slots available for saving
your own Disc. Patterns, and a slot for saving
your QuickMask Pattern.
To Select a Discrimination Pattern:
1 Press the Menu button
2 Scroll across to Discrimination (using the
Right or Left Navigation button)
3 Scroll down to Select (using the Down
Navigation button)
4 Press either the Left or Right Navigation
button to enter the Select sub-Menu
5 Scroll down to the desired Pattern and
press the Detect button to load it into
the Pattern/Digital Screen, or press the
QuickMask button to load it into the
QuickMask Screen, and resume detecting
Saving a Discrimination Pattern
The Save sub-Menu allows you to save the
current Discrimination Pattern to one of
the empty slots or overwrite an existing
Pattern. If the Save sub-Menu is entered from
QuickMask, instead of the Pattern/Digital
Screen, the sub-Menu will be titled ‘Save
QuickMask’.
To Save a Discrimination Pattern:
1 Press the Menu button
2 Scroll across to Discrimination (using the
Right or Left Navigation button)
3 Scroll down to Save, or Save QuickMask
if you have entered from the QuickMask
Screen (using the Down Navigation button)
4 Press either the Left or Right Navigation
button to enter the Save sub-Menu
5 Scroll down to an empty slot, or a Pattern
you wish to overwrite and press the Left or
Right Navigation button to Save
6 Press the Detect button to exit the sub-
Menu and resume detecting
Page 25
44
45
Discrimination Menu
Edit Screen
By selecting the Edit option in the
Discrimination Menu, you will enter the Edit
Screen. You can use the various functions
of the Edit Screen to modify an existing
Discrimination Pattern, or create your own.
Any changes made to a Discrimination
Pattern may then be saved for future use, via
the Discrimination Menu (p. 43).
If you enter the Edit Screen from the Pattern/
Digital Screen, the Edit Screen will display the
same Discrimination Pattern you were using
in those screens.
Edit Frame Sizes
Pressing the
Left Shift button scrolls
down the Frame sizes:
Small
Medium
Large
All Pattern
If you enter the Edit Screen from QuickMask,
the Edit Screen will display the QuickMask
Discrimination Pattern.
The Smartfind Window in the centre of
the Edit Screen displays the Discrimination
Pattern. The Edit Frame Size options are to the
left, the Edit Mode options are to the right.
Tip: Changing the Trash Density setting (pp.
72–3) from High to Low can stabilise the FE-CO
coordinates of a detected target while using any
‘Auto’ Edit Modes.
Ferrous– Conductivity
Numbers
The FE-CO numbers of
the Edit Frame position.
Edit Modes
Pressing the
Right Shift button scrolls
down the Edit Modes:
Manual
Auto Latch
Auto Accept
Auto Reject
Edit Frame
Using the Navigation
buttons, you can position
the Edit Frame anywhere
within the Disc. Pattern.
In combination with the
Accept/Reject button,
any part of the Disc.
Pattern can be modified.
In addition to the Edit Modes, E-Trac provides
four Frame Sizes with which to edit the
Discrimination Pattern. Pressing the Left Shift
button scrolls through the Frame Sizes.
The Frame Sizes are:
Small
This Frame Size will modify a 1x1 FE-CO area
of the Discrimination Pattern.
Medium
This Frame Size will modify a 3x3 FE-CO area
of the Discrimination Pattern.
Large
This Frame Size will modify a 5x5 FE-CO area
of the Discrimination Pattern.
All Pattern
This Frame Size will modify all of the
Discrimination Pattern. All Pattern can be
used to either clear (accept) the Disc. Pattern
or reject the Disc. Pattern.
The size of the Edit Frame sets how ‘loosely’
the target’s ferrous and conductivity
characteristics are recorded. The Large Edit
Frame is better for accepting desired targets.
The Small Edit Frame is better for rejecting
undesired targets and minimising the risk of
masking desired targets.
E-Trac has four different Edit Modes for
Discrimination editing. Pressing the Right Shift
button scrolls through the Edit Modes.
The Modes are:
Manual Mode
When operating in this Edit Mode, you can
manually move the Edit Frame around the
Discrimination Pattern. By using the Accept/
Reject button you can edit areas of the
Discrimination Pattern to either accept (white
areas) or reject (black areas) certain targets.
Auto Latch Mode
When operating in this Edit Mode E-Trac
automatically selects the ferrous and
conductivity coordinates of a detected target.
This allows you to either accept or reject the
target from the Discrimination Pattern using
the Accept/Reject button.
Auto Accept Mode
When operating in this Edit Mode, the
Discrimination Pattern will be automatically
modified to accept the Ferrous and
Conductivity coordinates of a detected target.
Auto Reject Mode
When operating in this Edit Mode, the
Discrimination Pattern will be automatically
modified to reject the Ferrous and
Conductivity coordinates of a detected target.
Note: Refer to pp. 46–50 for further information
on Edit Modes.
Page 26
46
47
Discrimination Menu
Manual Mode
Manual Mode allows you to manually move
the Edit Frame around the Discrimination
Pattern. By using the Accept/Reject button
you can edit areas of the Discrimination
Pattern to either accept (white areas) or reject
(black areas) certain targets.
To move the Edit Frame:
Press, or press and hold, the Navigation
buttons (Up, Down, Left and Right) to move
the Edit Frame around the Disc. Pattern.
To reject the framed area:
Press the Accept/Reject button. A cross will
appear above the Smartfind Window and the
area of screen within the Edit Frame will turn
black. You can now move the Edit Frame to
another part of the Discrimination Pattern
and continue Editing.
To accept the framed area:
Press the Accept/Reject button. A tick will
appear above the Smartfind Window and the
area of screen within the Edit Frame will turn
white. You can now move the Edit Frame to
another part of the Discrimination Pattern
and continue Editing.
Tip: Holding down the Accept/Reject button
while moving the Edit Frame around the
Smartfind Window continually edits the pattern.
To change the size of the Edit Frame:
Press the Left Shift button to switch between
the four Edit Frame sizes.
If you are moving the Edit Frame across
the Smartfind Window, either horizontally
or vertically, and you reach the edge of the
Smartfind Window the Edit Frame will loop
back to the opposite side. This feature is
designed to allow you to quickly move
from one edge of the Smartfind Window
to the other.
CAUTION: Pressing the Menu button
while in Edit will take you back to the
Discrimination Menu and all changes
made in Edit will be lost.
Page 27
48
49
Discrimination Menu
Auto Latch Mode
The Auto Latch Mode automatically selects
the FE-CO coordinates of a detected target.
This allows you to either accept or reject the
target from the Discrimination Pattern using
the Accept/Reject button.
Creating a Discrimination Pattern
using Auto Latch:
Clear the Smartfind Window:
Press the Left Shift button until the ‘All
Pattern’ Edit Frame is selected. Press the
Accept/Reject button once to accept the
entire Discrimination Pattern. This clears the
Smartfind Window, accepting all targets
and preparing the window for learning a
new target.
Change the size of the Edit Frame:
Press the Left Shift button to change the
Edit Frame size (Small, Medium, Large or All
Pattern). A Large frame will accept a larger
area of the Discrimination Pattern as a target
is detected. A Small frame will accept a
smaller area of the Discrimination Pattern,
but slightly altered or damaged targets may
be ignored.
To Auto Latch the target:
1 Place the target on the ground
2 Press the Right Shift button until the Auto
Latch Edit Mode is selected
3 Swing the coil several times over the
desired target until the detector confirms
the FE-CO coordinates
4 Press the Accept/Reject button once to
reject those coordinates from the Smartfind
Discrimination Pattern, press twice to
accept. If you have more than one target,
repeat the procedure for each one
5 Press the Detect button (or QuickMask
button if you wish to load the pattern into
QuickMask) once you have finished editing
6 Answer ‘Yes’ to the dialogue to return to
the Pattern/Digital (or QuickMask) Screen
with your new Discrimination Pattern
loaded into Smartfind
Tip: Changing the Trash Density setting (pp.
72–3) from High to Low can stabilise the
FE-CO coordinates of a detected target while
using any ‘Auto’ Edit Modes.
Auto Accept Mode
When a target is detected in Auto Accept
Mode, the Discrimination Pattern will be
automatically modified to accept the FE-CO
coordinates of that target.
E-Trac needs to detect the target consistently
to accept it into the Smartfind Disc. Pattern.
Creating a Discrimination Pattern
using Auto Accept:
Fill in the Smartfind Window:
Press the Left Shift button until the ‘All
Pattern’ Edit Frame is selected. Press the
Accept/Reject button twice to reject the
entire Discrimination Pattern. This fills in the
Smartfind Window, rejecting all targets
and preparing the Window for learning a
new target.
Change the size of the cursor:
Press the Left Shift button to change the
Edit Frame size (Small, Medium, Large or
All Pattern).
To Auto Accept the target:
1 Place the target on the ground
2 Press the Right Shift button until the Auto
Accept Edit Mode is selected
3 Swing the coil several times over the
desired target until the detector accepts
it by clearing an area in the Smartfind
Window. If you have more than one target,
repeat the procedure for each one
4 Press the Detect button (or QuickMask
button if you wish to load the pattern into
QuickMask) once you have finished editing
5 Answer ‘Yes’ to the dialogue box to return
to the Pattern/Digital (or QuickMask) Screen
with your new Discrimination Pattern
loaded into Smartfind
CAUTION: Pressing the Menu Button
while in Edit will take you back to the
Discrimination Menu and all changes
made in Edit will be lost.
Page 28
50
51
Discrimination Menu
Auto Reject Edit Mode
When a target is detected in Auto Reject
Mode, the Discrimination Pattern will be
automatically modified to reject the FE-CO
coordinates of that target.
E-Trac needs to detect the target consistently
to reject it from the Smartfind Disc. Pattern.
Creating a Discrimination Pattern
using Auto Reject:
To Auto Reject the target:
1 Place the target on the ground
2 Press the Right Shift button until the Auto
Reject Edit Mode is selected
3 Swing the coil several times over the
desired target until the detector rejects it
by filling an area in the Smartfind Window.
If you have more than one target, repeat
the procedure for each one
4 Press the Detect button (or QuickMask
Button if you wish to load the pattern into
QuickMask) once you have finished editing.
5 Answer ‘Yes’ to the dialogue box to return
to the Pattern/Digital (or QuickMask) Screen
with your new Discrimination Pattern
loaded into Smartfind
The Combine Function
Combine allows you to merge preset or
saved Discrimination Patterns to create a new
Discrimination Pattern. The Combine function
should not be confused with how you select
Discrimination Patterns via the ‘Select’ Menu.
With Combine, you do not add or subtract
whole Discrimination Patterns. The ‘white’
areas of a listed Discrimination Pattern are
what you accept or reject from the Combine
Discrimination Pattern.
The two Smartfind Windows at the top
of the Combine Screen are the Combine
Pattern (left) and the Active Discrimination
Pattern (right). The Active Pattern is the
Discrimination Pattern currently being used in
the Pattern/Digital Screen.
CombineActive
By default, the Combine Pattern (left
Smartfind Window) is empty. As you scroll
down the listed Discrimination Patterns, areas
of the Combine Pattern will flash relative to
the white areas of the selected Discrimination
Pattern. For example, if you select the
Jewellery Disc. Pattern, then the white area
of that pattern will flash in the Combine
Pattern. Each Pattern that is pre-programmed
into E-Trac is an ‘accepting’ pattern, i.e. the
Jewellery Disc. Pattern accepts Jewellery, the
Iron Disc. Pattern accepts Iron, etc. Therefore,
the ‘flashing’ area indicates where the object
is located.
Clear the Smartfind Window:
Press the Left Shift button until the ‘All
Pattern’ Edit Frame is selected. Press the
Accept/Reject button once to accept the
entire Discrimination Pattern. This clears the
Smartfind Window, accepting all targets and
preparing the Window for learning a new
target.
Change the size of the cursor:
Press the Left Shift button to change the
Edit Frame size (Small, Medium, Large or
All Pattern).
CAUTION: Pressing the Menu Button
while in Edit will take you back to the
Discrimination Menu and all changes
made in Edit will be lost.
Page 29
52
53
Discrimination Menu
The Accept/Reject button is used to modify
the flashing area of a selected Discrimination
Pattern. The first press accepts, the second
press rejects, and a third press cancels any
accepting or rejecting of that pattern applied
to the Combine Pattern.
Selected
Accepted
While a Discrimination Pattern is selected,
press the Left or Right Shift button to inverse
that pattern. The Accept/Reject button still
only modifies the white area of the pattern.
For example, if ‘Coins’ is inverted, accepting
the pattern will accept the white areas,
therefore leaving you with an ‘all metal’
pattern. If the pattern is rejected, the white
areas are visible in the Combine Pattern, thus
creating a pattern that rejects everything
except the common Target IDs of coins.
To Combine Discrimination Patterns:
1 Press the Menu button
2 Scroll across to Discrimination (using the
Right or Left Navigation button)
3 Scroll down to Combine (using the Down
Navigation button)
4 Press either the Left or Right Navigation
button to enter the Combine list of Pattern
6 Scroll down to the desired Pattern and
press the Accept/Reject button once to add
that Pattern to your Combine Pattern. Press
the Accept/Reject button twice to subtract
that Pattern from your Combine Pattern. A
third press will remove the Pattern from the
Combine Pattern
Rejected
Cancelled
It is important to plan how you will create
or modify a pattern using Combine, as the
last pattern accepted/rejected overrides any
previously accepted/rejected patterns if the
areas overlap. For example, if you reject the
‘All Metal’ pattern, then accept ‘Coins’ but
finish by rejecting ‘Crown Caps’, the area of
‘Crown Caps’ that overlaps ‘Coins’ will still be
rejected. Therefore, if you want to combine all
of these patterns you should apply rejected
patterns first, and accepted patterns last.
Another useful feature of Combine is the
ability to compare Target IDs in both the
Active Pattern (right Smartfind Window) and
the Combine Pattern (left Smartfind Window)
simultaneously. If you detect a target while
in Combine a crosshair will appear in both
windows. By doing this you can see whether
your new Combine Pattern is rejecting a
desirable target, or accepting an undesired
target, and you can then modify your
Combine Pattern further to get the right
discrimination.
5 The two Smartfind Windows at the top of
the screen are the Active Pattern (right)
and the Combine Pattern (left). Press the
Left Navigation button to copy the Active
Pattern to the Combine Pattern
7 Once you have finished Combining, press
the Detect button (or QuickMask button
if you wish to load the pattern into
QuickMask)
8 Answer ‘Yes’ to the dialogue box to return
to the Pattern/Digital (or QuickMask) Screen
with your new Discrimination Pattern
loaded into Smartfind
CAUTION: Pressing the Menu Button
while using Combine will take you back
to the Discrimination Menu and all
changes made with Combine will
be lost.
Page 30
54
55
Sensitivity Menu
Sensitivity
Range: Manual or Auto
Factory Preset: Auto
E-Trac has three internal signal channels (high,
medium and low) used to identify targets.
E-Trac continually measures the magnetic
ground interferences that affect these
channels and adjusts the level of Sensitivity
individually for each channel, to provide the
most stable Target ID for each channel.
Most ground types cause some interference
and E-Trac uses this to adjust the detector to
the correct Auto Sensitivity. Auto Sensitivity
may not work well on a beach, as they do not
typically contain magnetic materials.
Note: Minelab recommends beginners use E-Trac
in the Auto Sensitivity mode, unless detecting on
a beach, where Manual is recommended.
The Sensitivity Gauge has two indication
bars in both Auto and Manual and a numeric
Sensitivity value above the gauge, as
shown below.
Sensitivity
Leve l
ManualAuto
Auto Sensitivity
The left bar and the numeric value indicates
the highest Sensitivity Level that either the
high, medium or low channel is operating in.
The right bar indicates the ‘Suggested’
Sensitivity Level. This is an average Sensitivity
Level of the high, medium and low channels.
Each channel is set to a different level of
sensitivity individually by the detector to
provide the most stable Target IDs.
For example, if E-Trac determines the
Sensitivity levels for each channel to be
High:20, Medium:15 and Low:10, the left hand
bar and the numeric value of the Sensitivity
Gauge will display 20. The Suggested
Sensitivity, the right hand bar, will display
the average of all three channels, which
will be 15.
Manual Sensitivity
The left bar and the numeric value indicate
the Sensitivity Level that you have set.
The right bar indicates the ‘Suggested’
Sensitivity Level the same as it does in Auto.
The important difference between Auto and
Manual is that all of the channels are set to
the same level in Manual and if set too high
may cause unstable Target IDs.
For example, if the Suggested Sensitivity
determined by the detector is 15 and you
set Manual Sensitivity to 20, all channels are
set to 20. If one channel is affected by the
ground conditions then Auto would normally
reduce the level for this channel. In Manual it
is not reduced and stays at 20 so the ground
interference may cause false signals and
unstable Target IDs.
Auto Sensitivity
Range: –3, –2, –1, A, +1, +2, +3
Factory Preset: A
The Sensitivity can be increased by +3 levels
or decreased by –3 levels. This feature allows
you to be more aggressive or conservative
while in Auto.
Increasing the Auto Sensitivity Level by +1,
+2, or +3 sets the Auto Sensitivity higher on
each channel than the automatic setting by
the number of levels you select. You may
prefer this if you do not mind a few false
signals, if it means detecting very faint target
signals. It also tends to reduce the accuracy
of Target IDs.
Decreasing the Auto Sensitivity Level by –1,
–2, or –3 sets the Auto Sensitivity lower on
each channel than the automatic setting by
the number of levels you select. You may
prefer this if you do not want to dig very
small targets and false signals. It also tends to
improve the accuracy of Target IDs.
When changed, the numeric value above the
Sensitivity Gauge will increase or decrease by
the number of steps you select and display
your setting. The Auto Sensitivity animation
above the gauge will change from to
either if increased or if decreased.
This is to indicate you have made a change.
To adjust the Auto Sensitivity Level in
the Pattern/Digital Screen:
1 Press the Up Navigation button to
increase Sensitivity.
2 Press the Down Navigation button to
decrease Sensitivity.
Page 31
56
57
Sensitivity Menu
Audio Menu
Sensitivity (cont)
Manual Sensitivity
Range: 1–30
Factory Preset: 22
Manual Sensitivity allows you to control
the Sensitivity directly. Manual Sensitivity is
suitable for the beach, nonmagnetic ground
or when there is EMI.
Increasing Manual Sensitivity Level sets each
channel to the Level you select. A High
Sensitivity setting will increase the amount of
false signals and may detect very faint Target
signals. It also tends to reduce the accuracy
of Target IDs.
Decreasing Manual Sensitivity Level sets
each channel to the Level you select. A Low
Sensitivity setting will decrease the amount
false signals and may not detect very faint
Target signals. It also tends to improve the
accuracy of Target IDs.
When changed, the numeric value above the
Sensitivity Gauge will increase or decrease by
the number of steps you select and display
your setting.
To adjust the Manual Sensitivity Level in
the Pattern/Digital Screen:
1 Press the Up Navigation button to
increase Sensitivity.
2 Press the Down Navigation button to
decrease Sensitivity.
To adjust Manual or Auto Sensitivity
via the Menu:
1 Press the Menu button
2 Scroll across to Sensitivity (using the Right
or Left Navigation button)
3 Scroll down to Sensitivity (using the Down
Navigation button)
4 Press either the Left or Right Navigation
button to switch between Manual or Auto
5 Scroll down to either Manual Level or
Auto Level
6 Press either the Left or Right Navigation
button to adjust the level of Sensitivity
7 Press the Detect button to exit the Menu
and resume detecting.
Note: If you experience erratic signals try
reducing the interference with Noise Cancel
before adjusting the Sensitivity. To do this,
press the Noise Cancel button (p. 31), or
manually select the channel with the least
noise via the Expert Menu (p. 75).
The Audio settings control the types and
levels of sounds emitted by the detector
while detecting and when a target is found.
The correct setup of Audio settings, relative to
your current detecting conditions, is vital to
successful detecting.
While setting-up your E-Trac, take the time to
experiment with the Audio settings so that
you become familiar with how they operate
and affect the target audio response.
Minelab recommends using the following
steps as a guide for how to adjust the Audio
settings to best suit your preferences and
detecting conditions.
Note: Threshold Level (pp. 58–9), Volume Limit
(p. 60) and Volume Gain (p. 61) are not included
in these steps as they are all settings that you
will need to change depending on
detecting conditions.
To adjust the Audio settings:
1 Select the Response (Normal, Long, Smooth
or Pitch Hold) (pp. 62–3) according to your
preferences, detection conditions, etc.
2 Select the No. of Tones (Multi, 1, 2 or 4)
(p. 64)
3 Adjust the Threshold Pitch (p. 69)
4 Select the Sounds (Conduct or Ferrous) (pp.
65–6) according to the types of targets you
are searching for.
Detect two targets that produce ‘close’
Target IDs (Close CO numbers if Conduct
Sounds is selected, or close FE numbers if
Ferrous Sounds is selected).
5 Adjust the Variability (p. 67) until you
achieve your preferred pitch separation
between the Target IDs.
6 Detect a target with High CO numbers if
Conduct is selected (or high FE numbers
for Ferrous Sounds). If the pitch of the
target audio response is too high for your
hearing, limit it with the Tone ID Limits
setting (p. 68). You can also reduce the
pitch by adjusting Variability.
Tip: Headphones allow you to hear subtle
variations in audio response and lessen exposure
to adverse conditions (i.e. wind), which may
mask sound from the speaker.
Headphones also minimise the disturbance to
other people in the area, and provide greater
battery efficiency than when audio is emitted by
the speaker.
Page 32
58
59
Audio Menu
Threshold Level
Range: 1–50
Factory Preset: 30
The constant background ‘hum’ produced by
the detector is called the Threshold. Variations
in the Threshold help you to hear very small
and deep targets. When a rejected target
is detected, the Threshold sound ‘blanks’
(becomes silent) indicating that an undesired
target is underneath the coil.
The Threshold is controlled by Threshold Level and Threshold Pitch (p. 69). The
correct setting of both Threshold settings will
depend on your hearing and environmental
noise such as wind, waves and machinery.
The Factory Preset for Threshold Level is set
at an appropriate level for E-Trac’s built-in
speaker. If the Threshold is too loud whilst
using headphones, use the Threshold Level
setting to reduce the volume.
Adjust the Threshold Level to a faint, audible
hum. This will highlight variations in signal
response which may indicate the presence
of a target. If the soil conditions change the
Threshold Level may need adjustment.
Audio range
that you are able
to hear.
Threshold Level
Just Right
Small signalVery loud
signal
If the Threshold Level is too high, accepted
targets will be harder to hear above the
Threshold ‘hum’. Small target responses will
become difficult to hear as the Threshold
nears a maximum setting of 50 when there
will be a persistently loud Threshold ‘hum’.
If the Threshold Level is too low, the slight
variation caused by a small or deep target
may not be sufficient to hear. Adjusting the
level to below an audible level will ensure
silent operation but could mask the audio
response from small targets.
Audio range
that you are able
to hear.
Threshold Level
Too Lo w
Small signal
now inaudible
Loud signal
Adjusting Threshold Level:
1 Press the ‘Menu’ button
2 Scroll across to ‘Audio’ (using the Right or
Left Navigation Button)
3 Scroll down to ‘Threshold Level’ (using the
Down Navigation Button)
4 Press either the Left or Right Navigation
Button to change the Threshold Level
5 Press the ‘Detect’ button to exit the Menu
and resume detecting
Threshold Level
Audio range
that you are able
to hear.
Too High
Small signal
masked
Loud signal
just audible
Page 33
60
61
Audio Menu
Volume Limit
Range: 0–30
Factory Preset: 30
The Volume Limit sets the maximum volume
of target signals. When detecting, the sound
produced by a distant target will be quiet.
As the coil gets closer to the target, the
volume increases until it reaches the Volume
Limit setting.
A high Volume Limit will allow a greater
difference between a small and large target.
High Vol. Limit
Audio range
that you are able
to hear.
A low Volume Limit will not allow a great
difference between a small and large target.
Audio range
that you are able
to hear.
Low Vol. Limit
The Factory Preset for Volume Limit is set
at an appropriate level for E-Trac’s built-in
speaker. If the audio is too loud whilst using
headphones, use the Volume Limit setting to
reduce the audio volume.
To adjust the Volume Limit:
1 Press the Menu button
2 Scroll across to Audio (using the Right or
Left Navigation button)
3 Scroll down to Volume Limit (using the
Down Navigation button)
4 Press either the Left or Right Navigation
button to change the Volume Limit
5 Press the Detect button to exit the Menu
and resume detecting
CAUTION: A high Volume Limit setting
might damage your hearing if a large
target is detected.
Volume Gain
Range: 1–30
Factory Preset: 24
The Volume Gain controls the amplification
of a target’s audio response, relative to the
target signal strength. The Volume Gain
control is the Audio setting that is most
similar to volume adjustments in other
devices (e.g. radio or television
volume controls).
With a setting of 1 the target signal will not
be amplified. Weak target signals will sound
quiet, medium target signals will sound midrange and strong target signals will sound
loud. There will be greater differentiation
between target signal strengths, however,
weak signals will be harder to hear.
Volume Limit
Volume Gain = 1
Target Response Volume
Weak
Medium
Strong
With a setting of 15, the audio response
will be partially amplified. Weak to medium
strength signals will sound louder, but strong
signals will not sound much louder than
medium signals as the volume reaches the
Volume Limit.
Target Signal Strength
Volume Limit
Volume Gain = 15
Target Response Volume
Weak
Medium
Strong
Target Signal Strength
With a setting of 30, all target signals will
be amplified to a loud audio response. At
this setting there will be less differentiation
between medium and strong signals, but
weak target signals will be easier to hear.
Volume Limit
Volume Gain = 30
Target Response Volume
Weak
Medium
Strong
Target Signal Strength
To adjust the Volume Gain:
1 Press the Menu button
2 Scroll across to Audio (using the Right or
Left Navigation button)
3 Scroll down to Volume Gain (using the
Down Navigation button)
4 Press either the Left or Right Navigation
button to change the Volume Gain setting
5 Press the Detect button to exit the Menu
and resume detecting
Page 34
62
63
Audio Menu
Response
Range: Normal, Long,
Smooth and Pitch Hold
Factory Preset: Normal
Detection Start
Detection End
The Response setting changes the way target
signals sound upon detection. Response can
improve your ability to identify certain targets
in different conditions, such as high trash,
mineralised ground and beaches.
As the coil is swept over a target, the target
signal rises. At the peak of the target signal,
audio is emitted. Minelab recommends first
learning how to operate the detector in the
Factory Preset ‘Normal’ audio Response.
After becoming familiar with the way E-Trac
interprets various targets, it is recommended
you experiment with the Response settings
listed right. Each Response will suit certain
detecting conditions. You will soon develop
your own preference by experimentation.
To change the Response:
1 Press the Menu button
2 Scroll across to Audio (using the Right or
Left Navigation button)
3 Scroll down to Response (using the Down
Navigation button)
4 Press either the Left or Right Navigation
button to change the Response to the
desired setting
5 Press the Detect button to exit the Menu
and resume detecting
Note: Even though you can still select Pitch
Hold when the No. of Tones is set to 1,
it will not have any effect on the target
audio response.
Normal
Emits a short response to targets (almost a ‘beep’).
Normal is recommended for general detecting
conditions. It allows the greatest differentiation
between the ground and a target, but has the
potential to miss small targets in areas littered with
objects producing target responses.
Long
Offers an almost continuous audio response. This
setting is ideal for responding to several targets close
together. It is recommended for the experienced user,
who can pick the tonal differences between various
targets. Long can be a little confusing for the
beginner but has the potential to offer greater
accuracy and depth.
Smooth
This setting is similar to Long, with the addition of
some filtering of the audio tone response. Smooth
reduces the variability of the pitch, offering a
smoother continuous sound.
Pitch Hold
When Pitch Hold is selected, the normal rise-andfall target signal is replaced with a continuous tonal
response. The tone emitted is the strongest signal
coming from the target, and will continue until a new
target is detected.
Peak Target Signal
ThresholdThreshold
Normal lasts until the target signal drops, then audio
blanks bringing a crisp end to the detection.
Response
ThresholdThreshold
Long lasts until the end of detection.
There is no blanking at the end of detection.
Response
ThresholdThreshold
Smooth lasts until the end of detection.
There is no blanking at the end of detection.
PitchPitchPitchSignal Strength
Response
ThresholdThreshold
Pitch Hold changes the Threshold to the highest
pitched tone produced during the detection.
Pitch
Response
ThresholdThreshold
Time
Blanking
Time
Time
Time
Blanking
Time
Page 35
64
65
Audio Menu
Tone ID
The Tone ID sub-menu allows you to define
how the tone of the audio varies when
different target characteristics are detected.
This can be a very useful feature in identifying
targets close to each other.
Number (No.) of Tones
Range: 1, 2, 4 or Multi
Factory Preset: Multi
You may select how many different tonal
responses there are while detecting.
These are:
– 1; all sound is monotone,
– 2; all sound is duo tone i.e. low and high,
– 4; four different tones ranging from low
to high,
– Multi; multiple tonal responses to different
target signals.
The Factory Preset number of Tones is set
to ‘Multi’, giving multiple tonal responses to
different targets.
To change the Number of Tones:
1 Press the Menu button
2 Scroll across to Audio (using the Right or
Left Navigation button)
3 Scroll down to Tone ID (using the Down
Navigation button)
4 Press either the Left or Right Navigation
button to enter the Tone ID sub-menu
5 Scroll down to No. of Tones
6 Press either the Left or Right Navigation
button to change the No. of Tones
7 Press the Detect button to exit the Menu
and resume detecting
Sounds
Range: Conduct or Ferrous
Factory Preset: Conduct
The Sounds setting allows you to set
the detector to emit a distinct audio
response based on either a target’s ferrous
characteristics or its conductive properties. To
test your selection it is necessary to move the
coil across one or more targets with different
conductive and ferrous characteristics.
Note: Even though you can still adjust the
Sounds when the No. of Tones is set to 1,
it will not have any effect on the target
audio response.
Conduct
When Conduct is selected, audio tones are
emitted according to the target’s conductivity
(the horizontal axis of the Smartfind Window,
or the second number in the Digital Screen).
Low Pitch
Conductivity
High Pitch
Low Pitch
Conductivity
A high pitched signal denotes a large, highly
conductive object with Target Crosshair
displayed near the right of the Smartfind
Window (or near a CO number of 50).
A low pitched signal denotes a small object
with low conductivity; the Target Crosshair
is displayed near the left of the Smartfind
Window (or near a CO number of 1).
Tip: Conduct is often preferred by coin hunters,
as desirable targets such as gold, copper and
silver coins will give a high tone signal response,
compared to low conductive junk targets such
as foil and pull tabs.
High Pitch
Page 36
66
67
Audio Menu
Tone ID (cont)
Ferrous
Selecting Ferrous causes emitted tones
to be generated according to the target’s
ferrous characteristics (the vertical axis of the
Smartfind Window, or the first number in the
Digital Screen).
A low ‘blaat’ tone denotes a highly ferrous
object, displayed on the bottom of the
Smartfind Window and having a high FE
number. A high-pitched ‘squeak’ tone denotes
a nonferrous target, displayed on the top of
the Smartfind Window and having a low
FE number.
High Pitch
FerrousFerrous
Low Pitch
High Pitch
Low Pitch
Tip: Ferrous is often preferred by relic and
jewellery hunters as desirable low conductive,
medium ferrous targets will give a higher pitched
signal response.
It may be useful to select Ferrous if searching
in QuickMask. There is less chance of a highferrous target producing a high tone signal
due to its high conductive characteristics.
To change the Sounds:
1 Press the Menu button
2 Scroll across to Audio (using the Right or
Left Navigation button)
3 Scroll down to Tone ID (using the Down
Navigation button)
4 Press either the Left or Right Navigation
button to enter the Tone ID sub-menu,
5 Scroll down to Sounds
6 Press either the Left or Right Navigation
button to change the Sounds between
Ferrous and Conduct
7 Press the Detect button to exit the Menu
and resume detecting
Variability
Range: 1–30
Factory Preset: 25
Variability controls how much the audio
pitch will change depending on target
characteristics.
A high Variability setting results in a
maximum variation of pitch from target to
target. A high Variability can aid in identifying
targets in close proximity to one another,
and is recommended when using a complex
Discrimination Pattern.
High Pitch
Pitch Variation
Low Pitch
Coin
A low Variability setting results in a minimum
variation of pitch from target to target.
With a low Variability, target information is
compromised, but the target response will
be more consistent. This is recommended for
users new to multi tone detectors, or if you
are using an ‘All Metal’ Discrimination Pattern.
High Variability
Foil
Low VariabilityHigh Pitch
Pitch Variation
Low Pitch
CoinFoil
To adjust the Variability:
1 Press the Menu button
2 Scroll across to Audio (using the Right or
Left Navigation button)
3 Scroll down to Tone ID (using the Down
Navigation button)
4 Press either the Left or Right Navigation
button to enter the Threshold sub-menu
5 Scroll down to Variability
6 Press either the Left or Right Navigation
button to change the Variability setting
7 Press the Detect button to exit the Menu
and resume detecting
Note: Even though you may still adjust the
Variability when the No. of Tones is set to 1,
it will not have any effect on the target
audio response.
Page 37
68
69
Audio Menu
Tone ID (cont)
Limits
Range: 1–30
Factory Preset: 30
Limit allows you to adjust the maximum
audio pitch of all tones emitted for Tone ID
Sounds; Ferrous and Conduct. Limits is
only available if the Number of Tones is set
to Multi.
A high Limit setting will allow E-Trac to
produce very high pitched target signals as
well as low pitched.
High Limit
Low
Conductivity
High
Conductivity
Minelab recommends setting the Limit
control to the highest tone you are
comfortable with. Use a highly conductive
object, such as a large silver coin, to test your
Limits setting.
To adjust the Limits:
1 Press the Menu button
2 Scroll across to Audio (using the Right or
Left Navigation button)
3 Scroll down to Tone ID (using the Down
Navigation button)
4 Press either the Left or Right Navigation
button to enter the Tone ID sub-menu
5 Scroll down to Limits
6 Press either the Left or Right Navigation
button to change the Limits setting
7 Press the Detect button to exit the Menu
and resume detecting
Threshold Pitch
Range: 1–30
Factory Preset: 15
Threshold Pitch changes the pitch of the
Threshold; a high Threshold Pitch is often
preferred by people with good hearing,
whereas a low Pitch is preferable to people
with hearing difficulties.
Adjusting Threshold Pitch:
1 Press the Menu button
2 Scroll across to Audio (using the Right or
Left Navigation button)
3 Scroll down to Threshold Pitch (using the
Down Navigation button)
4 Press either the Left or Right Navigation
button to change the Threshold Pitch
5 Press the Detect button to exit the Menu
and resume detecting
A low Limit setting will allow E-Trac to only
produce low pitched target signals.
Low Limit
Low
Conductivity
High
Conductivity
Page 38
70
71
Expert Menu
The Expert Menu contains some of E-Trac’s
more advanced settings and functions.
While the settings and functions within the
Expert Menu will allow you to get the most
out of your E-Trac, Minelab recommends
that you become familiar with the other
settings and functions of the detector before
experimenting with these.
Recovery Deep and Recovery Fast
The Recovery Deep and Recovery Fast
settings allow you to select the way the
discrimination process works. Recovery
settings affect both the detector’s audio and
display response to target characteristics.
Recovery Deep
Range: On–Off
Factory Preset: Off
This setting affects only weak target signals,
enhancing identification of deep targets.
This setting should be selected in relatively
uncluttered areas where deep targets are
anticipated. Strong signals are unaffected.
In the deep setting there will be a slightly
slower reaction in target signal and Target ID
due to the extra filtering that is employed in
the processing of the target characteristics.
To turn Recover Deep On or Off:
1 Press the Menu button
2 Scroll across to Expert (using the Right or
Left Navigation button)
3 Scroll down to Recovery Deep (using the
Down Navigation button)
4 Press either the Left or Right Navigation
button to turn Recovery Deep On or Off
5 Press the Detect button to exit the Menu
and resume detecting
Recovery Fast
Range: On–Off
Factory Preset: Off
By selecting this setting, the detector
will react faster to target signals, but the
discrimination and Target ID may be slightly
more erratic. Use Fast in areas littered with
objects, where a desired target could be
hiding next to unwanted objects.
For example, if there are two targets very
close together that cause a single detection,
the filtering that is usually employed
when Recovery Fast is Off may cause a
‘contamination’ of the Target IDs,
as shown below.
With Recovery Fast On, the usual filtering
is bypassed and this can provide a more
accurate ID of the second target due to the
reduced blending of target signals. However,
as a consequence of removing the filtering
the Target IDs may be slightly more erratic.
Recovery Fast Off
Volume
CoinNail
Recovery Fast On
Volume
CoinNail
In the example shown, using Recovery Fast
will provide two distinct target IDs in each
direction, whereas when Recovery Fast is Off
the ID will be more variable and may not
resemble either of the targets.
Note: Minelab recommends turning Recovery
Fast On when Trash Density (pp. 72–3) is set to
High
To turn Recover Fast On or Off:
1 Press the Menu button
2 Scroll across to Expert (using the Right or
Left Navigation button)
3 Scroll down to Recovery Fast (using the
Down Navigation button)
4 Press either the Left or Right Navigation
button to turn Recovery Fast On or Off
5 Press the Detect button to exit the Menu
and resume detecting.
Time
Time
Page 39
72
73
Expert Menu
Trash Density
Range: Low or High
Factory Preset: Low
The Trash Density setting will enable you to
optimise the Discrimination of the detector
for areas that have highly variable ground
mineralisation or unusually high amounts of
ferrous objects.
When the Discrimination Pattern is ‘All Metal’,
the Trash Density setting has no effect.
When the Discrimination Pattern has rejected
(black) areas E-Trac will produce different
detection results depending on the Trash
Density setting. The Trash Density setting will
not affect the target audio response
Low is recommended in areas that have low
ground mineralisation or low amounts of
ferrous trash.
High is recommend in areas with highly
variable ground mineralisation or unusually
high amounts of ferrous objects (Iron trash).
Trash Density Performance Characteristics
SettingAccept/Reject
Functionality
LowVery goodVery goodAverage – may miss
Trash Density
High AverageVery goodGood
Low
In Low setting, E-Trac locks onto the strongest
signal target during detection and the
detector displays the most stable Target ID.
For example, when a coin is buried amongst
nails and you are using a Disc. Pattern that
accepts coins and rejects nails, the detector
will lock onto the target with the strongest
signal. If the coin produces a stronger signal
response, then the Target ID for the coin will
be displayed at the end of detection.
Target Signal
If the nail produces a stronger signal
response, then the Detector will blank at the
end of detection and the Target ID will not
update as the nail is a rejected by your Disc.
Pattern.
Detection in average
soils, and low trash sites
Detection in mineralised
soils, and high trash sites
detection of nonferrous
targets
Target Signal
It is recommended to use Low in areas with
low trash. It is not recommended to use Low
in areas where a “good” target may be masked
by the presence of strong signals from ferrous
objects or high ground mineralisation.
The Low Trash Density setting also allows
you to create a quite narrow discrimination
pattern for a specific target as the Target ID is
more stable than in High Trash Density.
High
In High setting, E-Trac searches for the best
accepted target signal during detection
and then displays the most stable Target
ID. The High setting allows you to detect
the accepted targets in the presence of
ferrous objects or high ground mineralisation
amongst a number of rejected targets.
For example, when a coin is buried amongst
nails and you are using a Disc. Pattern that
accepts coins and rejects nails, the detector
will lock onto the coin and the Target ID
for the coin will be displayed at end of
detection. If the nail produces stronger signal
response the Detector will not blank at end of
detection and the Target ID for the coin will
be displayed at end of detection.
It is recommended to use High in areas with
high trash and where a “good” target may
be masked by the presence of many ferrous
objects or high ground mineralisation.
In a High Trash Density setting the Target ID is
more unstable, therefore, a greater number of
Target ID numbers need to be used to reject
a specific target.
High Trash Density can be used with a slightly
faster sweep, so it is suitable for use during
competition hunts or in areas where speed of
ground coverage is important.
To turn Trash Density to Low or High:
1 Press the Menu button
2 Scroll across to Expert (using the Right or
Left Navigation button)
3 Scroll down to Trash Density (using the
Down Navigation button)
4 Press either the Left or Right Navigation
button to turn Trash Density to Low
or High
5 Press the Detect button to exit the Menu
and resume detecting
Page 40
74
75
Expert Menu
Ground
Range: Neutral or Difficult
Factory Preset: Difficult
The Ground setting affects the way the
detector responds to the mineralisation of
the soil. The correct Ground setting for your
detecting conditions will reduce false signals
from the soil and improve the stability of the
Target ID.
Selecting the appropriate Ground setting will
also improve the performance of the Depth
Gauge in those soils.
In some areas the Neutral setting will be
adequate and produce the best detection
results. However, there are types of soil where
the Difficult setting is more appropriate,
particularly when the soil conditions force a
reduction of the Sensitivity Level, in either
Manual or Auto (pp. 54–6).
There are also types of soil where changing
the Ground setting will not have a
pronounced effect, in this case either Neutral
or Difficult can be used.
Neutral should always be used whilst
detecting on the beach. However, for
beaches where the sand is contaminated
with mineralisation (e.g. black sand), some
experimentation is required.
A useful way to determine the type of ground
in which you are detecting is to monitor the
Auto Sensitivity (p. 55). In typically neutral
soil types the detector will run at higher Auto
levels and in difficult mineralized or magnetic
soils the detector will reduce the Sensitivity
(pp. 54–6).
To determine the Ground setting:
1 Find an area free of targets and set E-Trac
to accept ‘All Metals’ by using QuickMask or
clearing the discrimination pattern.
2 Switch to Manual Sensitivity and start
sweeping the clear area of soil as if
detecting for targets.
3 Progressively increase the Sensitivity
until the detector starts detecting the soil
and note this particular Sensitivity value
and the Target IDs you get from the soil.
4 Change the Ground setting to ‘Difficult’
and repeat the procedure, again noting the
Sensitivity value and the Target IDs you get
from the soil.
5 Choose the Ground setting that allows you
to use the highest Sensitivity and displays
any soil Target IDs in an area that is easily
masked by your discrimination.
Note: It should be understood that the value
determined by the test above is a maximum
usable value and not necessarily one that would
ensure accurate Target IDs. The ‘suggested’
Sensitivity should be used as a guide in setting
the Manual Sensitivity.
Regardless of the Ground setting, the stability of
the Target ID (and in particular the FE numbers)
is negatively affected if the Sensitivity is set too
high. Auto Sensitivity is the preferred option
to use inland, as it continuously monitors the
soil conditions and selects a Sensitivity which
gives a relatively stable Threshold (p. 58–9), and
consistent Target ID.
Noise Cancel
Range: 1–11
Factory Preset: 6
Manual Noise Cancel
The Noise Cancel setting allows you to
manually select and listen to each channel for
the least interference.
To manually adjust Noise Cancel:
1 Make sure there are no large targets or
obvious sources of EMI close by, then hold
the detector 30cm (12”) above the ground
30cm
(12”)
2 Press the Menu button
3 Scroll across to Expert (using the Right or
Left Navigation button)
4 Scroll down to Noise Cancel (using the
Down Navigation button)
5 Keep the detector 30cm (12”) above
the ground and completely still. Press
the Left and Right Navigation buttons to
select a channel. Pause and listen to the
interference coming from the detector
while adjusting the Noise Cancel channel
6 Once a channel has been found with the
least interference, press the Detect button
to save and exit the Menu; and resume
detecting.
Once a channel is selected, most audio
responses to electromagnetic sources (e.g.
power lines) will be eliminated.
Tip: Noise Cancel is handy for metal detecting
competitions when several E-Tracs are working
close to one another. Each detector can be set
to operate on a different channel so interference
between detectors is eliminated. In this case, it is
best to select the channels manually.
Page 41
76
77
Preferences Menu
The Preferences Menu allows you to change
the appearance of E-Trac’s Detection Screens
by using settings such as Contrast, Display
Timeout, and Show Sensitivity. It also allows
you to select a different Pinpoint Mode and
perform a Master Reset.
Contrast
Range: 1–30
Factory Preset: 15
The Contrast setting allows you to adjust the
level of LCD contrast to best suit the current
light conditions. The LCD may become
difficult to see in either bright or overcast
conditions.
To adjust the Contrast:
1 Press the Menu button
2 Scroll across to Preferences (using the Right
or Left Navigation button)
3 Scroll down to Contrast (using the Down
Navigation button)
4 Press either the Left or Right Navigation
button to change the setting
5 Press the Detect button to exit the Menu
and resume detecting
Pinpoint Mode
Range: Normal or Sizing
Factory Preset: Normal
There are three different Pinpoint Modes;
Normal, Sizing and Fixed.
Normal
After activating Pinpoint, the first sweep over
a target will generate a wide audio response.
Wide response
With each sweep, the zero point, or baseline
of the audio response, is set to a new
level, just below the maximum signal. The
Sensitivity is also adjusted. These adjustments
keep the audio response narrow, but will
allow targets of different depths to be
pinpointed with equal precision.
Narrow response
A long pause between coil sweeps will
produce a wide audio response, due to
the baseline falling between sweeps. Short
pauses between sweeps will keep the audio
responses narrow.
Small or deep targets may not be detected
after sweeping over a target with a large
signal. Some time is required to allow the
baseline to fall to a sufficiently low level.
Sizing
After activating Pinpoint, the baseline is set to
a signal level. From then on, the baseline and
the sensitivity are held at constant levels.
When sweeping over a target, the detector
produces a linear audio tone. The pitch of
the tone is proportional to the strength
of the target response, and the volume is
proportional to the position of the target
under the coil.
Activating Pinpoint while the coil is away
from the target will allow the extent of the
target to be determined.
Full response
Activating Pinpoint while the coil is near
the target will allow portions of the target
response to be masked.
Masked response
Note: Do not initiate Pinpoint while over the
centre of the target or the whole target may be
masked.
To change the Pinpoint Mode:
1 Press the Menu button
2 Scroll across to Preferences (using the Right
or Left Navigation button)
3 Scroll down to Pinpoint Mode (using the
Down Navigation button)
4 Press either the Left or Right Navigation
button to change the mode
5 Press the Detect button to exit the Menu
and resume detecting
Note: Pinpoint turns E-Trac into an ‘all metal’
detector, disabling discrimination.
Page 42
78
79
Preferences Menu
Show Sensitivity
Range: On or Off
Factory Preset: On
You can select whether the Sensitivity Gauge
(pp. 54–6) appears on the Detection Screens
or not. If the Sensitivity Gauge is On, you will
be able to adjust the Sensitivity using the
Navigation Buttons. If the Sensitivity Gauge is
Off, you need to enter the Sensitivity Menu to
adjust the Sensitivity settings.
To show or hide the Sensitivity Gauge:
1 Press the Menu button
2 Scroll across to Preferences (using the Right
or Left Navigation button)
3 Scroll down to Show Sensitivity (using the
Down Navigation button)
4 Press either the Left or Right Navigation
button to change between On or Off
5 Press the Detect button to exit the Menu
and resume detecting
Show Mode Info
Range: On or Off
Factory Preset: Off
Show Mode Info allows you to turn the Mode
Information Icons (p. 38) On or Off. Selecting
On displays the Mode Information Icons in
the Detection Screens. Off hides the Mode
Information Icons.
Mode Information Icons
To show or hide the Mode Information
icons:
1 Press the Menu button
2 Scroll across to Preferences (using the Right
or Left Navigation button)
3 Scroll down to Show Mode Info (using the
Down Navigation button)
4 Press either the Left or Right Navigation
button to change the between On or Off
5 Press the Detect button to exit the Menu
and resume detecting
Display Timeout
Range: On or Off
Factory Preset: Off
Display Timeout can be turned On or Off.
When the Display Timeout is On, the last
detection result will be cleared from the
screen after 5 seconds. The detection results
are FE-CO numbers, Target Crosshair and
Depth Gauge.
When the Display Timeout is Off, the last
detection result will remain until a new
detection is made, or the Detection Screen is
changed.
Detection Results
To turn Display Timeout On or Off:
1 Press the Menu button
2 Scroll across to Preferences (using the Right
or Left Navigation button)
3 Scroll down to Display Timeout (using the
Down Navigation button)
4 Press either the Left or Right Navigation
button to change the between On or Off
5 Press the Detect button to exit the Menu
and resume detecting
Master Reset
Master Reset will restore all settings to the
Factory Presets and erase all of your User
Modes and Discrimination Patterns.
If you only require a Reset, see p. 19 for more
information.
Note: If you enter the ‘Master Reset’ dialogue
box by mistake, scroll down to Cancel to return
to the Preferences Menu.
To Master Reset the detector:
1 Press the Menu button
2 Scroll across to Preferences (using the Right
or Left Navigation button)
3 Scroll down to Master Reset (using the
Down Navigation button)
4 Press either the Left or Right Navigation
Button to enter Master Reset
5 Scroll up to Yes and press either the Left
or Right Navigation button to initiate the
Master Reset.
A ‘Reset’ message will appear on the screen
and a tune will sound. Once the message
disappears and the Pattern Screen appears
on the LCD the detector has been reset
and E-Trac is ready to detect again.
Page 43
80
81
E-Trac Xchange
Technical Specifications
Communicating between E-Trac and
your Personal Computer
A significant feature of E-Trac is the inclusion
of a USB connection facility, allowing you to
connect your E-Trac to a Personal Computer
(PC) to download/upload detector User
Modes, Discrimination Patterns and Settings
for optimum performance.
System Requirements:
– Windows 2000, Windows XP or Windows
Vista
– Minimum display resolution of 1024 x 768
– USB or USB 2.0 port
– USB Data Cable (included with your E-Trac)
To install E-Trac Xchange on your PC:
1 Insert the CD (included with your E-Trac)
into the CD/DVD drive of your PC.
2 The CD will auto-run once inserted into
your PC and the Install program will start.
3 Follow the install prompts to install E-Trac
Xchange onto your PC.
Once you have installed E-Trac Xchange on
your PC you can start the application from
either the Start Menu or the shortcut on
the Desktop.
To start the E-Trac Xchange application:
1 Double click the E-Trac Xchange application
icon on your desktop, or open your Start
Menu and navigate to: All Programs –
Minelab – E-Trac Xchange
To connect E-Trac to your PC:
1 Insert the USB cable into your E-Trac
2 Insert the other end of the USB cable into
your PC
3 Start E-Trac Xchange on your PC
4 Although E-Trac’s transmitter is switched
off while connected to a PC, make sure the
coil is not sitting next to any large metal
objects, then turn on your E-Trac
Note: Refer to the Help menu in E-Trac
Xchange for more information on how to
use the application to download, upload and
modify your E-Trac’s settings.
Detector
Transmission Full Band Spectrum (FBS).
Simultaneous Frequency Transmission ranging
from 1.5–100kHz
Coil 11” Double D
Audio Output Internal Speaker and Headphones
Liquid Crystal Display (LCD) 240 x 160 pixels (72mm x 48mm)
Length Collapsed: 1060mm (41.7”)
Extended: 1380mm (54.3”)
Detector Weight 1.6kg (3.53lbs) (excluding batteries and
Operating Temperature Range 0 °C to 50 °C (32 °F to 122 °F)
Operating Humidity Range Up to 90% Relative Humidity at 40 °C (104 °F)
Storage Temperature Range –30 °C to 80 °C (–22 °F to 176 °F)
Storage Humidity Range Up to 98% Relative Humidity at 40 °C (104 °F)
Battery
Type Nickel Metal Hydride (NiMH)
Output Voltage 9.6V
Capacity 1600mAh
Input (Charge) 12V @ 100mA
Charge Time 18 hours
Weight 255g (0.56lbs)
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature –30 °C to 80 °C (–22 °F to 176 °F)
Battery Charge Temperature Range 0 °C to 45 °C (32 °F to 113 °F)
Page 44
82
83
Factory Presets Table
All Settings
Setting TitleRangeFactory PresetMy Preferred
User Modes
Minelab Mode–Coins Mode
Discrimination
Pattern–Coins Mode
Sensitivity:
Sensitivity ModeAuto or ManualAuto
Manual Sensitivity Level1–3022
Auto Sensitivity Level–3 to +3A
Audio:
Threshold Level1–5030
Volume Limit0–3030
Volume Gain1–3024
Response Normal, Long, Smooth
or Pitch Hold
Tone ID No. of Tones1, 2, 4 or MultiMulti
Tone ID SoundsConduct or FerrousConduct
Tone ID Variability1–3025
Tone ID Limits1–3030
Threshold Pitch1–3015
Expert:
Recovery DeepOn or OffOff
Recovery FastOn or OffOff
Trash DensityLow or HighLow
GroundNeutral or DifficultDifficult
Noise Cancel1–116
Preferences:
Contrast1–3015
Pinpoint ModeNormal or SizingNormal
Show SensitivityOn or OffOn
Show Mode InfoOn or OffOff
Display TimeoutOn or OffOff
– These settings are not reset to their Factory Presets when you initiate a Reset (p. 19) upon startup.
To reset all settings and clear your User Modes and Disc. Patterns, initiate a Master Reset (p. 79).
Normal
User Mode Settings Factory Presets
Setting TitleRangeCoinsHigh TrashBeachRelic
Discrimination:
Pattern–Coins ModeHigh Trash
Audio:
Volume Gain1–3024222624
Response Normal, Long, Smooth
or Pitch Hold
Tone ID No. of Tones1, 2, 4 or MultiMultiMultiMultiMulti
Tone ID SoundsConduct or FerrousConductConductConductFerrous
Tone ID Variability1–3025252525
Tone ID Limits1–3030303030
Expert:
Recovery DeepOn or OffOffOffOnOn
Recovery FastOn or OffOffOnOffOn
Trash DensityLow or HighLowHighLowHigh
GroundNeutral or DifficultDifficultNeutralNeutralDifficult
E-Trac has a Battery Icon on the LCD that
indicates the present charge level, and
provides advanced warning of the need to
recharge or replace the battery. The Battery
Icon displays the battery charge level in
four segments.
As E-Trac operates, the segments of the
Battery Icon will decrease relative to the
voltage left in the battery. When the last
segment disappears, the Battery Icon will
begin to flash and the Battery Low sound will
emit every 20 seconds. If the detector is still
operating at this time the voltage will drop to
a point when a “FLAT BATTERY” message will
appear and the detector will turn itself off.
Battery at full charge.
Note: The detector regulates the output voltage
so the performance of the detector will remain
the same regardless of the charge remaining in
the batteries.
To extend battery life:
– Use headphones. The speaker uses
significantly more power than headphones.
– Turn off the Backlight. The Backlight
increases the power consumption by
approximately 8%.
– Turn the detector off when not in use.
The typical discharge times for both
good quality alkaline and Minelab NiMH
rechargeable batteries under constant use are
compared on the graph on p. 85. This graph
assumes the Backlight is off, and headphones
are used instead of the speaker.
Typical alkaline batteries will power E-Trac for
over 16 hours of constant use. The Minelab
NiMH 1600 Slimpack will power the
detector for over 14 hours of constant use
and the Minelab NiMH 1800 Slimpack for
over 16 hours.
Unlike Nickel Cadmium batteries, the Minelab
NiMH Slimpack DOES NOT need to be fully
discharged before recharging.
Whenever the detector has been unused for
a lengthy period, recharge the battery pack
to ensure full charge level. NiMH batteries do
not hold their charge when not in use.
Charging the battery for longer than 18hrs
will not damage the NiMH Slimpack.
When the battery voltage has been depleted
(indicated by the Battery Icon), Minelab
recommends the Slimpack be recharged, or
alkaline batteries replaced, as soon as possible
to avoid missing any targets.
CAUTION: Do not leave discharged
alkaline batteries in the detector as they
may leak and damage the detector.
Battery at three quarter charge.
Battery at half charge.
Battery at one quarter charge.
Battery almost depleted. The icon will flash and a low battery tune
will sound every 20 seconds.
Flat Battery message. The detector will turn itself off to
preserve settings.
13
12
11
10
Approximate Battery Voltage (volts)
1600 NiMHAA Battery1800 NiMH
9
Shutdown Voltage
8
0
2468101214161820
Approximate Time (hours)
Page 46
86
87
Recovering the Target
Treasure Locations
A trowel, knife or small spade are good tools
for recovering targets.
Once a target has been located, clear the
surface of loose material and check again for
a signal. If there is no signal then the target
is amongst the surface material. In this case,
search the surface material until the target
is located. If the target is still in the ground,
Pinpoint its position.
Using a sharp tool, cut a neat portion of grass
or soil and place it on a plastic sheet. This
prevents the material being scattered around
and allows the hole to be refilled quickly.
Dig carefully to avoid defacing or devaluing
the object.
Check the hole for the target. If it is not in
the hole, place the detector on the ground
with the coil flat, pick up a handful of soil and
pass it over the coil. Be sure not to wear rings,
bracelets or a watch which will produce a
signal. Repeat this procedure until the target
is located.
Ensure that no other targets remain, then refill
the hole. All soil and portions of grass on the
plastic sheet should be returned to the hole
as neatly as possible. Step lightly on the soil
to compact it.
A question most new detectorists ask is,
“where do I find treasure”? There are actually
lots of areas in which you can search. It is
best if you research where people have been
in the past, what type of objects they might
have had with them, and hopefully lost. You
can also go to areas people still use on a daily
basis such as the beach or parks, and search
for modern coins and jewellery.
Here is a list of some of the more productive
places to search:
– Your own backyard
– The beach
– Showgrounds & racecourses
– Picnic areas
– Battlefields
– Camping grounds
– Swimming holes
– Parks and playgrounds
– Ghost towns & ancient town sites
– Old homes & public buildings
– Old gold mining sites
– Sports grounds
– School yards and ovals
– Around jetties and piers
– Drive-in theatres
There is a chance of finding buried treasure,
such as coins, relics and jewellery, anywhere
that people have been in the past. In order
to maximise your return, select sites that have
the most potential.
For example, a small park that is just used
as a walkway between houses is likely to
be littered with junk with very few valuable
targets in it. Whereas a larger old park with
picnic tables, playgrounds, etc. would have
had thousands of people sitting around,
playing sports, laying on blankets etc. and
you can almost be certain that there will be
some goodies waiting for your metal detector.
Be sure to obtain the land owners permission
before searching on private property, be sure
to also check local regulations.
Note: Always check your local regulations and
laws before detecting in a public or private area.
Always refill your holes. If you leave the
ground exactly as you found it, you shouldn’t
have any problem detecting the same area in
the future.
Leaving holes, or a scarred area, may result
in action being taken to prevent the use
of metal detectors. Please ensure that you
remove all rubbish. The aim is to leave the
area of ground exactly as you found it.
Page 47
88
89
Accessories
Detector Care and Safety
Parts and Accessories available
for E-Trac:
– 8” FBS Coil
– 8” FBS Coil Skidplate
– 11” E-Trac Coil Skidplate
– Sealed 1800mAh Rechargeable
NiMH SlimPack
– 12V Car Charger
– Koss UR-30 Headphones
– Tall Man Lower Shaft
– Control Box Cover
– Detector Carry Bag
– Minelab Tool & Trash Bag
If you would like to purchase any
accessories for your E-Trac or any other
Minelab product, please feel free to contact
us directly or via your local Authorised
Minelab dealer.
8” FBS Coil
1800mAh NiMH SlimPack
12V Car Charger
Koss UR-30 Headphones
E-Trac is a high-quality electronic instrument,
finely engineered and packaged in a durable
housing. Taking proper care of your detector
is mostly common-sense.
CAUTION
– Please note the following:
– Do not leave the battery pack in the E-Trac
handle when the detector is not in use
for extended periods. Damage caused
by leaking batteries could be severe and
would void the warranty through user
negligence.
– Do not leave the detector in excessive cold
or heat for longer than necessary. Covering
it when not in use will help protect it.
Avoid leaving it in a closed car boot or
in a car sitting in sunlight. A full-length
detector carry bag is available to protect
the detector when in transit.
– The control box has been designed to resist
moisture, but is not water-proof. Minelab
advises protecting the control box in
extreme conditions. The control box should
not be dropped into water. A control box
cover will give protection against dust, dirt
and light rain.
– Never allow the detector to come into
contact with gasoline or other petroleumbased liquids.
– Keep the detector clean and dry and avoid
getting sand and grit into the shafts or
fastenings (e.g. yoke bolt and camlocks). Do
not use solvents to clean the detector. Use
a damp cloth with mild soap detergent.
– Ensure the coil cable is in good condition
and not subject to undue stress.
– Flat or faulty batteries cause many detector
problems. Ensure that only quality alkaline
batteries are used, and that they are
replaced when you hear the warning signal
through the headphones or speaker.
– Do not dispose of the battery pack in fire
(contact local authorities for disposal/
recycling). Do not attempt to disassemble
or short circuit the battery pack.
– Take precautions when transporting or
storing the detector. Although the detector
is constructed from the highest quality
materials and has undergone rigorous
durability tests, the display screen could be
prone to scratching or serious damage if
not treated with due care.
Page 48
90
91
Troubleshooting
Warranty
Detector does not start at all
Detector starts, but switches
off by itself
No sound
Erratic noises
– Check the condition of the batteries and battery connections.
– Ensure battery pack is fully inserted, and it has clicked into place.
– If using alkaline batteries, check whether they have been loaded
in the right polarity.
– Ensure that you are not holding, or pressing, the Backlight button
while pressing the Power button.
– Ensure that you allowed longer than 1 second between Power Off
and Power On.
– Check the condition of the batteries. If necessary, try starting with
batteries known to be in good condition.
– Detector may be too hot. Allow detector to cool down in a
shaded area.
– Try starting the detector with search coil disconnected. If the
detector star ts normally, check the state of the coil cable. If it is
damaged, replace the coil. Otherwise return detector for repairs.
– Unplug the headphones. If there is sound in the speaker but not
in the headphones, check the headphones and their connection.
– Check the Audio > Volume Limit
(a setting of 0 is silent).
– If there is no sound in the speaker or the headphones but the
detector appears to work normally otherwise, return the detector
for repairs.
– Press the Noise Cancel button or manually select a quiet channel.
– Reduce the Sensitivity.
– Change the orientation of the coil to the vertical plane and rotate
to see if there is a position where the noise is loudest.
If this is the case, it means that there is a source of interference
nearby which must be avoided.
– Check battery charge and battery connections.
– Ensure coil connector is tightened firmly.
– Check headphones and their connection.
– Check for sand or grit between coil cover and coil.
There is a two-year parts and labour warranty
for the electronic control box of E-Trac. The
coil has a one year parts and labour warranty.
Refer to the supplier or Minelab for service,
either in or out of warranty. The Minelab
warranty does not cover damage caused
by accident, misuse, neglect, alteration,
modifications, or unauthorised service.
For specific details of the Minelab warranty,
please refer to E-Trac’s ‘Product Warranty Card’.
This warranty is not transferable, nor is it valid
unless the enclosed warranty registration card
is returned to Minelab or your Minelab dealer
within 14 days of the original purchase.
Repairs
In the unfortunate circumstance that the
detector needs to be returned to Minelab for
service, please fill out the Minelab Service
Repair Form (or a photocopy of the same)
and enclose it with the detector.
Please supply as much detail about the
fault as possible. This will assist our service
engineers to rectify the problem quickly
and efficiently.
No target response
– Ensure the detector is turned on.
– Check headphones and their connection.
– Check coil connection.
– Check discrimination level. No signal will be given if target is
within black area of screen.
Page 49
Minelab Electronics Pty Ltd
PO Box 537, Torrensville Plaza
Adelaide, South Australia, 5031