• Insulated piezoresistive pressure sensor encapsulated in an oil-lled metal housing
• RS485 bus interface for communication with up to 128 devices
• Battery-operated with up to 2000 hours of battery life
• Can be used with external power supply
• License-free KELLER software available to download
• Intrinsically safe, explosion-proof version LEX 1 Ei available
Functions
• Wide range of units of pressure to choose from
• Zero point calibration via button
• Automatic shutdown
• Min/max display
• User-dened units of pressure can be congured
• Digital calibration (zero point, end point)
Typical applications
• Calibration
• Laboratory use
• Industrial applications
Accuracy
± 0,05 %FS
Total error band
± 0,05 %FS
Pressure ranges
from 0...30 mbar to 0...1000 bar
LEX-1 with piezoresistive measuring cellLEX-1 with capacitive measuring cell
KELLER AG für Druckmesstechnik
CH-8404 Winterthur
+41 52 235 25 25
info@keller-druck.com
KELLER Ges. für Druckmesstechnik mbH
DE-79798 Jestetten
+49 7745 9214 0
eurocenter@keller-druck.com
KELLER America
Newport News, Virginia
1 877 253 5537
sales@kelleramerica.com
Edition 05/2019
Subject to alterations
Companies approved to ISO 9001
www.keller-druck.com
Page 2 of 6
LEX 1 – Specications
Standard pressure ranges
LEX 1 piezoresistive
Gauge pressure, PR
Absolute pressure, PAA
Absolute pressure, PA
Overload resistance
Display resolution
LEX 1 capacitive
Gauge pressure, PR
Differential pressure, PD
Overload resistance
Negative overload resistance
Display resolution
Key
Performance
-1…1-1…3-1…6-1…10-1…16-1…30bar rel.
0…20…40…70…110…170…310…61 0…101 0…161bar abs.
882020909030030060060080011001100 bar
0,10,1111111010102050100 mbar
0…30 0…100 0…300
30010001500 mbar
30100300 mbar
0,010,010,1 mbar
PR Gauge pressure Zero at atmospheric pressure
PAA Absolute pressure Zero at 0 mbar abs. (vacuum)
PA Absolute pressure Zero at 1000 mbar abs.
PD Differential
Total error band (0...50 °C)≤ ± 0,2 %FS Max. deviation within the specied pressure and temperature range
Long-term stability≤ 0,1 %FS Per year under reference conditions, yearly recalibration recommended
Long-term stability 30 mbar range≤ 0.1 mbar Per year under reference conditions, yearly recalibration recommended
Degree of dependency on locationnone
Line pressure dependency (PD versions)≤ ± 0,005 %FS / bar
Accuracy of temperature measurement± 1 °C typ.
Pressure range reserve± 10%
Line pressure≤ 2 bar
KELLER AG für Druckmesstechnik
CH-8404 Winterthur
+41 52 235 25 25
info@keller-druck.com
KELLER Ges. für Druckmesstechnik mbH
DE-79798 Jestetten
+49 7745 9214 0
eurocenter@keller-druck.com
KELLER America
Newport News, Virginia
1 877 253 5537
sales@kelleramerica.com
Edition 05/2019
Subject to alterations
Companies approved to ISO 9001
www.keller-druck.com
Page 3 of 6
LEX 1 – Specications
Performance
Optional for LEX 1 piezoresistive
Precision @ RT (20…25 °C)
Accuracy @ RT≤ ± 0,01 %FS
For PA/PAA ≥ 10 bar, except for ush versions.
Accuracy ± 0,05 %FS, with KELLER test report ex works (standard)
Keller uses pressure sources to calibrate its products that are at least four times more accurate than the product
to be tested. This enables us to produce products in our factory with an absolute accuracy of up to ± 0,05 %FS.
Precision ± 0,01 %FS / 0,025 %FS, with KELLER test report ex works
Additional measurement work and selection of a specic pressure transducer means that optimum repeatability
is guaranteed for selected pressure transmitters and digital manometers. Owing to the residual measurement
uncertainty of the pressure sources used at its factory, KELLER cannot provide any verication of measurement
accuracy at scales below ± 0,05 %FS for these ultra-precise devices. KELLER therefore uses the term "precision" to denote the ability of a pressure transmitter or manometer to repeat measured values within a tolerance
of 0,01 %FS based on the pressure sources used at the factory.
Accuracy ± 0,01 %FS with DakkS (German accreditation body) certicate,
issued by an external accredited calibration laboratory
By calibrating the zero point and performing amplication via the digital interface, an accredited calibration
laboratory (ilac.org) can adapt ultra-precise KELLER products to their more accurate pressure sources and
record the results. External calibration to an accuracy of up to ± 0,01 %FS is performed in accordance with
the guidelines set out by the German Calibration Service (DKD) and is conducted under reference conditions
without any consideration of long-term effects.
≤ ± 0,01 %FS
≤ ± 0.025 %FS
Nonlinearity (BFSL), pressure hysteresis, non-repeatability,
with KELLER test report ex works
With DakkS (German accreditation body) certicate issued
by external calibration laboratory
Temperature ranges
Compensated temperature range0…50 °C
Media temperature0…50 °C
Ambient temperature0…50 °C
Storage temperature-20…70 °C
Electrical data
Battery3 V, type CR2430
Battery lifeapprox. 2000 hourswhen used continuously
External power supply8...28 VDC
Overvoltage protection and reverse polarity of
external power supply
RS485 voltage insulation-7...+12 VDC
GND case insulation> 10 MΩ @ 50 VDC
External interfaceRS485 half-duplex
Interface measuring rate30 measurements per second
Electrical connectionFischer D 103 A054-130
CE conformity as per 2014/30/EU (EMC)
± 32 VDC
EN 61000-6-1 to -6-4
EN 61326-1 / EN 61326-2-3
LEX1 Ei only permitted for use in hazardous atmospheres when used with the
Renata CR2430
LEX 1 Ei devices must not be supplied
with power from an external source and
the RS485 interface must not be used in
the Ex zone. See operating instructions
for further information
KELLER AG für Druckmesstechnik
CH-8404 Winterthur
+41 52 235 25 25
info@keller-druck.com
KELLER Ges. für Druckmesstechnik mbH
DE-79798 Jestetten
+49 7745 9214 0
eurocenter@keller-druck.com
KELLER America
Newport News, Virginia
1 877 253 5537
sales@kelleramerica.com
Edition 05/2019
Subject to alterations
Companies approved to ISO 9001
www.keller-druck.com
Page 4 of 6
LEX 1 – Specications
Display
Dimensions/appearance
Number of digits on LC display2 rows with 5 digits each
Display modePressure + min/max or pressure + temperature
Measuring rate2 measurements per second
Congurable units of pressure
Additional units of pressure5 user-dened units can be congured
Width x height: 27,8 x 30,0 mm " see Dimensions & options
Pressure transducer seal (internal)FKM (Viton® type A)Nitrile
Pressure connection seal (external)FKM (Viton® type A)FKM (Viton® type A)
Other materials
ComponentLEX 1 piezoresistiveLEX 1 capacitive
Display housingFaradex AS-1003Faradex AS-1003
Oil lling pressure transducerSilicone oilNone
Further details
ComponentLEX 1 piezoresistiveLEX 1 capacitive
Pressure connectionG1/4, see Dimensions & options
Diameter x height x depth (approx.)76 x 118 x 55 mm76 x 148 x 55 mm
Weight (approx.)300 g335 g
ProtectionIP65
Explosion protection LEX 1 Ei
Intrinsically safe version
in accordance with 2014/34/EU and IECEx
KELLER AG für Druckmesstechnik
CH-8404 Winterthur
+41 52 235 25 25
info@keller-druck.com
PTB 05 ATEX 2012 X
IECEx PTB 13.0028 X
Zone 1: Ex II 2 G Ex ia IIC T6 Gb
KELLER Ges. für Druckmesstechnik mbH
DE-79798 Jestetten
+49 7745 9214 0
eurocenter@keller-druck.com
Permitted max. ambient
temperature range -20…65 °C
KELLER America
Newport News, Virginia
1 877 253 5537
sales@kelleramerica.com
Edition 05/2019
Subject to alterations
Companies approved to ISO 9001
www.keller-druck.com
Page 5 of 6
LEX 1 – Dimensions & options
J
E
2:1
G
2:1
J
G
2:1
J
FischerFlanschdose
DEE103 A054-130
Binder Flanschstecker
Serie723
StiftplattemPm-393
1
2
3
4
5
2
0
5
G1/2
1
4
1/4-18NPT
1
5
2
0
2
0
5
1/4-18NPT
1
5
2
0
2
0
5
2
0
2
0
5
6
1
5
3
7
°
43,5
1
4
1
6
G1/2
2
0
5
6
1
2
G1/4
G1/2
1
4
1/4-18NPT
1
5
1/2-14NPT
2
0
1
3
3
5
1
5
3
7
°
50,5
43,5
1
6
G1/2
2
0
5
6
G1/2
1
4
1/4-18NPT
1
5
1/2-14NPT
2
0
1
3
3
5
50,5
43,5
G1/2
2
0
5
6
1/4-18NPT
1
5
1/2-14NPT
2
0
1
3
3
5
G1/4
G1/2
2
0
5
6
1/2-14NPT
2
0
1
3
3
5
G1/4
G1/2
2
0
5
6
1
3
3
5
G1/4
Display
PlacementDisplay information
Width x height:
27,8 x 30,0 mm
Digit height:
8,4 pt. large
6,3 pt. small
External connection
PlacementConnectionPin assignment
Fischer connector D 103 A054-130Red Reference point
1GND
1
5
2
4
3
2n.c.
3+Vcc
4RS485 A
5RS485 B
Available pressure connections
G1/4 (standard)G1/21/4 NPT1/2 NPTG1/2 EN 837
0
2
1
G1/4
4
1
G1/2
5
1
1/4-18 NPT
0
2
1/2-14 NPT
G1/2 ushG3/4 ush7/16-20 UNFClamp DIN 32676 ushG1/4 EN 837
5
1
43,5
50,5
G1/2
G3/4
7/16-20 UNF-2A
3
7
°
Other pressure connections available upon request.
Other customer-specic options
• Other pressure and temperature ranges
• Parts that come into contact with media made from Hastelloy, Inconel or titanium
• Customer-specic front covers
• Integration of application-specic calculations
• Customer-specic rmware
• Detached pressure transducer
• Axial pressure connection
• Other sealing materials
• Other oil llings pressure transducer
2
5
G1/2
6
KELLER AG für Druckmesstechnik
CH-8404 Winterthur
+41 52 235 25 25
info@keller-druck.com
KELLER Ges. für Druckmesstechnik mbH
DE-79798 Jestetten
+49 7745 9214 0
eurocenter@keller-druck.com
KELLER America
Newport News, Virginia
1 877 253 5537
sales@kelleramerica.com
Edition 05/2019
Subject to alterations
Companies approved to ISO 9001
www.keller-druck.com
Page 6 of 6
LEX 1 – Software & accessories
Swiss Made
«CCS30» software
Recording measured values
• Live visualisation
• Adjustable measuring and storage interval
• Export function
Conguration
• Call up of information (pressure and temperature
range, rmware version, serial number etc.)
«ManoCong» software
The ManoCong program is compatible with all
types of KELLER manometers and allows end cus-
tomers to congure the devices.
Range of functions
• Display of online measured values
• Conguring the wait period before automatic
shutdown
• Selecting standard pressure units
Interface
The LEX 1 manometer has a digital interface (RS485
half-duplex) which supports the KELLER bus protocol. The pressure measurement rate via the interface is up to 30 x per second. Details of the communication protocols can be found at www.keller-druck.
com. Documentation, a Dynamic Link Library (DLL)
and various programming examples are available to
integrate the communication protocol into your own
software.
• Activating/deactivating pressure units
• User-dened pressure units can be programmed
• Restoring to factory settings
• Calibrating the manometer
Interface converters
The connection to a computer is established via an
RS485-USB interface converter. Suitable converters
Software download
are available as accessories. To ensure smooth operation, we recommend the K-114 A converter with
www.keller-druck.com/software
the corresponding USB connector.
Scope of delivery
Plastic caseCR2430 batteryKELLER test reportOperating instructions D/E/F
LEX 1
Aktueller DruckwertActual Pressure Value
Valeur de pression actuelle
Min.-/Max.-Druckwert
Min.-/Max. Pressure Value
Valeur de pression Min./Max.