Keller LEO5 Specifications

LEO 5
1
2
29,5
45
8
9
,
5
3
6
,
5
G 1/4
30
SW 27
High-resolution digital manometer
Features
Insulated piezoresistive pressure sensor encapsulated in an oil-lled metal housing
• Robust, watertight stainless steel housing with safety glass front
• Large, backlit LC display
• Integrated rechargeable battery (USB chargeable)
• License-free KELLER software available to download
Functions
• High-resolution pressure measurements
• Pressure peak detection with 5 kHz sampling frequency
• Data logger
• Operated via capacitive touch keys
• Bar graph display
• Temperature display
• Min/max display
Typical applications
• Pressure testing
• Calibration
• Laboratory use
• Industrial applications
Accuracy
± 0,05 %FS
Total error band
± 0,1 %FS
Pressure ranges
from -1...3 bar to 0...1000 bar
LEO 5 manometer
40
27
8
, 1 8
30
SW 27
G 1/4
LEO 5 with rubber cover
45
29,5
5
, 9 8
1 4
2 1
30
SW 27
G 1/4
5
, 6 3
2 1
KELLER AG für Druckmesstechnik CH-8404 Winterthur
+41 52 235 25 25 info@keller-druck.com
KELLER Ges. für Druckmesstechnik mbH
DE-79798 Jestetten
+49 7745 9214 0 eurocenter@keller-druck.com
KELLER America
Newport News, Virginia
1 877 253 5537 sales@kelleramerica.com
Subject to alterations Companies approved to ISO 9001
www.keller-druck.com
Page 2 of 5
LEO 5 – Specications
Standard pressure ranges
Gauge pressure, PR
Absolute pressure, PAA
Absolute pressure, PA
Overload resistance
Display resolution
Key
-1…1 -1…3 -1…6 -1…10 -1…16 -1…30 bar rel.
0…2 0…4 0…7 0…11 0…17 0…31 0…61 0…101 0…161 bar abs.
0…300 0…400 0…700 0…1000 bar
8 8 20 20 40 60 200 200 300 600 800 1100 1100 bar
0,1 0,1 1 1 1 1 1 10 10 10 20 50 100 mbar
PR Gauge pressure Zero at atmospheric pressure PAA Absolute pressure Zero at 0 mbar abs. (vacuum) PA Absolute pressure Zero at 1000 mbar abs.
Performance
Accuracy @ RT (20...25 °C) ≤ ± 0,05 %FS
Total error band (0...50 °C) ≤ ± 0,1 %FS Max. deviation within the specied pressure and temperature range
Long-term stability ± 0,1 %FS Per year under reference conditions, yearly recalibration recommended
Degree of dependency on location ≤ ± 1,5 mbar
Accuracy of temperature measurement ± 1 °C typ.
Pressure range reserve ± 10%
Vacuum endurance ≤ 0,2 bar abs. Of operation ≤ 0,2 bar abs. upon request
Nonlinearity (BFSL), pressure hysteresis, non-repeatability,
zero point, amplication
Calibrated in vertical installation position with pressure connection facing downwards
Temperature ranges
Compensated temperature range 0…50 °C
Media temperature 0…50 °C
Ambient temperature 0…50 °C
Storage temperature -20…70 °C
KELLER AG für Druckmesstechnik CH-8404 Winterthur
+41 52 235 25 25 info@keller-druck.com
KELLER Ges. für Druckmesstechnik mbH
DE-79798 Jestetten
+49 7745 9214 0 eurocenter@keller-druck.com
KELLER America
Newport News, Virginia
1 877 253 5537 sales@kelleramerica.com
Subject to alterations Companies approved to ISO 9001
www.keller-druck.com
Page 3 of 5
LEO 5 – Specications
Electrical data
Rechargeable battery Lithium-ion 4,2 V / 2,3 Ah
Battery life (standard) Up to 2000 hours of continuous operation
Battery life (peak mode) Up to 160 hours of continuous operation
Battery charging cycles > 300
GND case insulation > 10 MΩ @ 300 VDC
External interface USB (KELLER protocol)
Interface measuring rate 2 measurements per second
Electrical connection Mini USB-B
CE conformity as per 2014/30/EU (EMC) EN 61000-6-1 to -6-4, EN 61326-1 / EN 61326-2-3
Data logger
Logger function Records pressure, temperature and measuring time
Data storage ≥ 56 000 measured values
Recording modes Interval, event-controlled
Measuring rate ≥ 1 second, can be congured in 1-second increments
Display
Dimensions/appearance Width x height: 51,3 x 38,8 mm, also refer to Dimensions & options
Number of digits on LC display 2 rows with 5 digits each
Display mode Pressure + min/max or pressure + temperature, additional bar graph
Measuring rate (standard) 2 measurements per second
Measuring rate (peak mode) 5 kHz (reduced resolution and accuracy)
Congurable units of pressure
Additional units of pressure 5 user-dened units can be congured
[bar], [mbar], [Pa], [hPa], [kPa], [MPa], [PSI], [mH2O], [cmH2O], [inH2O], [ftH2O], [mmHg], [inHg], [kp/cm2]
Mechanical data
Materials in contact with media
Pressure connection Stainless steel AISI 316L
Pressure transducer separating diaphragm Stainless steel AISI 316L
Pressure transducer seal (internal) FKM (Viton® type A)
Pressure connection seal (external) FKM (Viton® type A)
Other materials
Display housing Stainless steel AISI 304
Oil lling pressure transducer Silicone oil
Further details
Pressure connection
Diameter x height x depth
Weight (approx.) 430 g
Protection IP66
KELLER AG für Druckmesstechnik CH-8404 Winterthur
+41 52 235 25 25 info@keller-druck.com
KELLER Ges. für Druckmesstechnik mbH
DE-79798 Jestetten
G1/4, other options see available pressure connections
Without rubber cover: Approx. 82 x 135 x 40 mm
With rubber cover: Approx. 90 x 139 x 45 mm
+49 7745 9214 0 eurocenter@keller-druck.com
KELLER America
Newport News, Virginia
1 877 253 5537 sales@kelleramerica.com
Subject to alterations Companies approved to ISO 9001
www.keller-druck.com
Page 4 of 5
LEO 5 – Dimensions & options
U
2 : 1
2
0
5
G1/2
1
4
1/4-18 NPT
1
5
2
0
2
0
5
1/4-18 NPT
1
5
2
0
2
0
5
2
0
2
0
5
6
G1/2
1
5
3
7
°
43,5
1
4
1
6
G1/2
2
0
5
6
1
2
G1/4
G1/2
1
4
1/4-18 NPT
1
5
1/2-14 NPT
2
0
1
3
3
5
1
5
3
7
°
50,5
43,5
1
6
G1/2
2
0
5
6
G1/2
1
4
1/4-18 NPT
1
5
1/2-14 NPT
2
0
1
3
3
5
50,5
43,5
G1/2
2
0
5
6
1/4-18 NPT
1
5
1/2-14 NPT
2
0
1
3
3
5
G1/4
G1/2
2
0
5
6
1/2-14 NPT
2
0
1
3
3
5
G1/4
G1/2
2
0
5
6
1
3
3
5
G1/4
U
2 : 1
U
2 : 1
Display External connection
Placement Display information
Placement Mini USB-B connection
Width x height: 51,3 x 38,8 mm
Digit height: 15 pt. large 10 pt. small
Available pressure connections
G1/4 (standard) G1/2 1/4 NPT 1/2 NPT G1/2 EN 837
0
2 1
G1/4
4 1
G1/2
5 1
1/4-18 NPT
0 2
1/2-14 NPT
G1/2 ush G3/4 ush 7/16-20 UNF Clamp DIN 32676 ush G1/4 EN 837
5 1
2
5
6
43,5
50,5
G1/2
G3/4
7/16-20 UNF-2A
3
7
°
Other pressure connections available upon request.
Optional advanced versions
Standard Detached sensors Bluetooth interface
Other customer-specic options
• Other pressure and temperature ranges
• Parts that come into contact with media made from Hastelloy, Inconel or titanium
Customer-specic front covers
Integration of application-specic calculations
Customer-specic rmware
• Other sealing materials
Other oil llings pressure transducer
KELLER AG für Druckmesstechnik CH-8404 Winterthur
+41 52 235 25 25 info@keller-druck.com
KELLER Ges. für Druckmesstechnik mbH
DE-79798 Jestetten
+49 7745 9214 0 eurocenter@keller-druck.com
KELLER America
Newport News, Virginia
1 877 253 5537 sales@kelleramerica.com
Subject to alterations Companies approved to ISO 9001
www.keller-druck.com
Page 5 of 5
LEO 5 – Software & accessories
«Logger 5» software
The Logger 5 software is suitable for the following activities:
• Reading data from the autonomous data collec-
tor, e.g. LEO 5, and saving to a le on a PC
Programming and conguring the data logger
• Active reading of the pressure and temperature measured values in one-second intervals and presenting the data in graphs
• Visualising and analysing measurements saved
in les
Printing out reports or saving them as PDF les
• Exporting data and making it available to other applications for further processing
• Performing level measurement calculations
Scope of delivery
«CCS30» software
Recording measured values
• Live visualisation
• Adjustable measuring and storage interval
• Export function
Conguration
• Call up of information (pressure and temperature
range, rmware version, serial number etc.)
“ManoCong” software
The ManoCong program is compatible with all
types of KELLER manometers and allows end cus-
tomers to congure the devices.
Range of functions
• Display of online measured values
Conguring the wait period before automatic shutdown
• Selecting standard pressure units
• Activating/deactivating pressure units
Programming user-dened pressure units
• Restoring to factory settings
• Calibrating the manometer
Interface
The LEO 5 manometer has a USB interface. Details of the communication protocols can be found at www.keller-druck.com. Documentation, a Dynamic Link Library (DLL) and various programming exam­ples are available to integrate the communication protocol into your own software.
Software download
www.keller-druck.com/software
Plastic case USB cable KELLER test report Operating instructions D/E/F
LEO 5
Hochauösendes Manometer mit Peak- und Aufzeichnungs-Funktion
High Resolution Manometer with Peak and Record Function
Manomètre haute résolution avec fonctions d’enregistrement et de mesure des pics de pression
Hinweis: Entlüftungsmembrane nicht eindrücken.
Note: Do not touch/press
ventilation lm.
Remarque: Ne pas appuyer sur la membrane de ventilation.
Betriebsanleitung · Operating Instructions · Notice d’utilisation
Swiss Made
Accessories
Calibration certicate Rubber cover
Issued by the external calibration laboratory of the German accreditation body DAkkS or the Swiss accredita­tion body SAS
For additional protection in harsh environments
KELLER AG für Druckmesstechnik CH-8404 Winterthur
+41 52 235 25 25 info@keller-druck.com
KELLER Ges. für Druckmesstechnik mbH
DE-79798 Jestetten
+49 7745 9214 0 eurocenter@keller-druck.com
KELLER America
Newport News, Virginia
1 877 253 5537 sales@kelleramerica.com
Subject to alterations Companies approved to ISO 9001
www.keller-druck.com
Loading...