Pressure transducer seal (internal)FKM (Viton® type A)
Pressure connection seal (external)FKM (Viton® type A)
Other materials
Display housingStainless steel AISI 304
Oil lling pressure transducerSilicone oil
Further details
Pressure connection
Diameter x height x depth
Weight (approx.)430 g
ProtectionIP66
KELLER AG für Druckmesstechnik
CH-8404 Winterthur
+41 52 235 25 25
info@keller-druck.com
KELLER Ges. für Druckmesstechnik mbH
DE-79798 Jestetten
G1/4, other options see available
pressure connections
Without rubber cover:
Approx. 82 x 135 x 40 mm
With rubber cover:
Approx. 90 x 139 x 45 mm
+49 7745 9214 0
eurocenter@keller-druck.com
KELLER America
Newport News, Virginia
1 877 253 5537
sales@kelleramerica.com
Edition 05/2019
Subject to alterations
Companies approved to ISO 9001
www.keller-druck.com
Page 4 of 5
LEO 5 – Dimensions & options
U
2:1
2
0
5
G1/2
1
4
1/4-18NPT
1
5
2
0
2
0
5
1/4-18NPT
1
5
2
0
2
0
5
2
0
2
0
5
6
G1/2
1
5
3
7
°
43,5
1
4
1
6
G1/2
2
0
5
6
1
2
G1/4
G1/2
1
4
1/4-18NPT
1
5
1/2-14NPT
2
0
1
3
3
5
1
5
3
7
°
50,5
43,5
1
6
G1/2
2
0
5
6
G1/2
1
4
1/4-18NPT
1
5
1/2-14NPT
2
0
1
3
3
5
50,5
43,5
G1/2
2
0
5
6
1/4-18NPT
1
5
1/2-14NPT
2
0
1
3
3
5
G1/4
G1/2
2
0
5
6
1/2-14NPT
2
0
1
3
3
5
G1/4
G1/2
2
0
5
6
1
3
3
5
G1/4
U
2:1
U
2:1
Display External connection
PlacementDisplay information
PlacementMini USB-B connection
Width x height:
51,3 x 38,8 mm
Digit height:
15 pt. large
10 pt. small
Available pressure connections
G1/4 (standard)G1/21/4 NPT1/2 NPTG1/2 EN 837
0
2
1
G1/4
4
1
G1/2
5
1
1/4-18 NPT
0
2
1/2-14 NPT
G1/2 ushG3/4 ush7/16-20 UNFClamp DIN 32676 ushG1/4 EN 837
5
1
2
5
6
43,5
50,5
G1/2
G3/4
7/16-20 UNF-2A
3
7
°
Other pressure connections available upon request.
Optional advanced versions
StandardDetached sensorsBluetooth interface
Other customer-specic options
• Other pressure and temperature ranges
• Parts that come into contact with media made from Hastelloy, Inconel or titanium
• Customer-specic front covers
• Integration of application-specic calculations
• Customer-specic rmware
• Other sealing materials
• Other oil llings pressure transducer
KELLER AG für Druckmesstechnik
CH-8404 Winterthur
+41 52 235 25 25
info@keller-druck.com
KELLER Ges. für Druckmesstechnik mbH
DE-79798 Jestetten
+49 7745 9214 0
eurocenter@keller-druck.com
KELLER America
Newport News, Virginia
1 877 253 5537
sales@kelleramerica.com
Edition 05/2019
Subject to alterations
Companies approved to ISO 9001
www.keller-druck.com
Page 5 of 5
LEO 5 – Software & accessories
«Logger 5» software
The Logger 5 software is suitable for the following
activities:
• Reading data from the autonomous data collec-
tor, e.g. LEO 5, and saving to a le on a PC
• Programming and conguring the data logger
• Active reading of the pressure and temperature
measured values in one-second intervals and
presenting the data in graphs
• Visualising and analysing measurements saved
in les
• Printing out reports or saving them as PDF les
• Exporting data and making it available to other
applications for further processing
• Performing level measurement calculations
Scope of delivery
«CCS30» software
Recording measured values
• Live visualisation
• Adjustable measuring and storage interval
• Export function
Conguration
• Call up of information (pressure and temperature
range, rmware version, serial number etc.)
“ManoCong” software
The ManoCong program is compatible with all
types of KELLER manometers and allows end cus-
tomers to congure the devices.
Range of functions
• Display of online measured values
• Conguring the wait period before automatic
shutdown
• Selecting standard pressure units
• Activating/deactivating pressure units
• Programming user-dened pressure units
• Restoring to factory settings
• Calibrating the manometer
Interface
The LEO 5 manometer has a USB interface. Details
of the communication protocols can be found at
www.keller-druck.com. Documentation, a Dynamic
Link Library (DLL) and various programming examples are available to integrate the communication
protocol into your own software.
Software download
www.keller-druck.com/software
Plastic caseUSB cableKELLER test reportOperating instructions D/E/F
LEO 5
Hochauösendes Manometer mit Peak- und Aufzeichnungs-Funktion
High Resolution Manometer with Peak and Record Function
Manomètre haute résolution avec fonctions d’enregistrement et de mesure des pics de pression
Hinweis: Entlüftungsmembrane nicht
eindrücken.
Note: Do not touch/press
ventilation lm.
Remarque: Ne pas appuyer sur la
membrane de ventilation.