Keli Sensing Technology D2008type User Manual

D2008type
User Manual
Version: December. 2018
●Please read this manual carefully before using
●Please keep this manual properly for reference
a
Index
1 Technical parameter ..................................................................................................... 错误!未定义书签。
2 Operation instructions .................................................................................................................................... 1
2.1 Start-up and automatic start-up zero setting ...................................................... 错误!未定义书签。
2.2 Manual zeto setting ........................................................................................... 错误!未定义书签。
2.3 Tare .................................................................................................................... 错误!未定义书签。
2.4 Zero Tare ........................................................................................................... 错误!未定义书签。
2.5 Date and time check and setting ....................................................................... 错误!未定义书签。
3 Store and print weighing record ................................................................................... 错误!未定义书签。
3.1 Store weighing record ....................................................................................... 错误!未定义书签。
3.2. Input method of tare storage ............................................................................. 错误!未定义书签。
3.3. Printing of weighing record .............................................................................. 错误!未定义书签。
3.4. Statistical form printing .................................................................................... 错误!未定义书签。
3.5 Inquiry weighing record .................................................................................... 错误!未定义书签。
3.6 Delete weighing record ..................................................................................... 错误!未定义书签。
3.7 Delete method of tare storage ............................................................................ 错误!未定义书签。
3.8Inquirying print ................................................................................................. 错误!未定义书签。
4 Information tips .......................................................................................................... 错误!未定义书签。
Appendix Athe example of printing operation ............................................................... 错误!未定义书签。
Appendix BExamples of breakdown .............................................................................. 错误!未定义书签。
The connection between load cell and indicator must be reliable, load cell's shielding wire must be reliable grounding. Connection inserting or pull out is not allow when indicator is under the state of power, prevent electrostatic damage the indicator or the load cell . Indicator and load cell are static sensitive equipment,anti-static measure must be taken when using, the welding operation or other high voltage operation on the weighing pad is prohibited , at the thunderstorm season, the reliable avoid measures must be implemented to prevent the lightning strike the load cell and the indicator, ensure the security of the operating personne and running of the weighing equipment and related equipment. Can not use in the area of flammable gas or flammable vapor,also can not use in the tank weighing system with pressure. Indicator and load cell must be away from the field with strong electric and magnet,and be away from strong corresive substance ,be away from inflammable and explosive materials.
Using strong solvents(such as benzene,nitro-class oil)to clean the housing is prohibited. Can not inject the liquid or other conductive particle into indicator to prevent to damage and electronic
shock.
b
1 Technical parameter
1.Type D2008type(H+HP+HP1+)
D2008type(D28+)
D2008type(20KB+20KBP+20KBP1+)
D2008type(20KC+20KCP+20KCP1+)
2.Digital load cell interface:
Communication mode RS485 Signal transmission distance 30M when connected with 12 load cells,pls contact us if you need further Transmission baud rate 960019200bps Excitation power DC12~14.8V Digital interface ability ≤16 digital load cells
3.Display 7 digits of LED7 digits of status symbols
4. Keyboard
Number Keys 0 ~ 9 Function keys 24 pcs10 of 24 are combined with Number keys
5.Clock
display year, month, date, hour, minute and second, leap year and leap month automatically.
6.Scoreboard display interface (electric isolated with load cell interface)
transmission mode: current loop and RS232 Transmission baud rate: 600bps
7.Serial communication interface (electric isolated with load cell interface)
transmission mode: RS232 Baud rate: Options of 600/1200/2400/4800/9600/19200
8.Printing interface (electric isolated with load cell interface)
With standard parallel printing interface, which can be connected with the wide line
printers , such as ESPON LQ-300K + Ⅱ 、 ESPON LQ-300K ESPON LQ-300K ,ESPON LQ-680K ESPON LQ-730K ESPON LQ-1600K(+)、 KX-P1131KX-P1121DS-300
9.Data storage
can store 1,000 groups of vehicle numbers and tare weight, 1500 groups new weighing records, 300 groups uncompleted weighing records, 6 groups overload records.
10. Operating environment
Power input : AC110~220V 50~60HZ
DC 12V Operating temperature: 0 ~ 40 Storage temperature : -25 ~ 55 Relative humidity : ≤85%RH
1
steps
operation
display
explain
1
press【CLOCK】
d12.05.13
Display the date
2
press【number key
d12.05.13
Modify the date
3
press 120515
d12.05.15
Enter current date
4
pressenter
d09.08.15
Show current date
5
pressenter
t12.53.48
Mark: if open the timing function, can not modify the date
6
press【number key
t12.53.30
Show the time
7
press 125345
t12.53.45
Enter correct time
8
press【enter 】
t12.53.45
Show current time
9
press【weigh】
Weighing interface
2 Operation instructions
2.1 Start-up and automatic start-up zero setting
Connect to power supply and turn on the power switch. The indicator begins self-checking. After successful self-checking, the indicator enters the weighing status. During the start-up, if the zero point is off-set but still in the range preset, the indicator will automatically. Refer to manual of calibration for the range of start-up zero setting.
2.2 Manual zero setting
Zero setting function is only valid when stability light is on. The keyZEROwill not work when the off-set is over the range of manual zero setting. Refer to manual of calibration for the range of start-up zero setting. Press the keyZEROand the indicator will return to zero and the zero light will be on.
2.3 Tare
D20 offers 2 types of taring. Under the weighing status.
A: Common taring: When the weight data is over 0 and stable, press the keyTare】and the value displayed will be deducted as tare weight. At this time, the indicator will display value of net weight. Tare indicating light will be on and gross indication light will be off.
B: Preset the tare weight Press the keyPreset】and the indicator will display【P*****】. Then input the tare weight, pressENTER and indicator will display original tare weight.
2.4 Zero tare
There are 2 modes: A. Under the status of taring, pressZEROto clear the tare weight and the tare indicating light will be off. This operation will be limited by Pn parameter B. Press Preset,set the tare weight is 0.
2.5 Date and time check and setting
3. The save and print of weigh result
3.1The save of weigh record
2
Step
Operation
Display
Explanation
1
PressV.N
Under weighing status
2
Input vehicle
number
PressENTER
o ***** o 35790
Input vehicle number. For example: 35790.
3 Input tare value
PressENTER
P ***** P 01000
Input tare weight. For example: 1000(kg).
4 Return to weighing status
End
1This indicator asked the car No. is 5 digit(1~99999),Art.No.is 3 digit0~200,
(2) It can save 1500 group weigh records mostly, after full, will delete the earliest group result.
(3) There are 3 ways to save the data: ① weight directly(press keysave1)save: When you make one weight, it can make the data as one group to save and print
First preset or call the known tare weight when weighing, (press key [ save1]) storage one time to constitute a complete set of records; or weighing cargo vehicles is only a cargo (the car number is00000 or do no use the number), (press [save 2] or [Save 1] key) one time and storage constitute a complete set of records.
Weighing twice save(press [Save 2] key): the first empty (press the [Save 2] key) storage ,then full of cars (press save 2 key) storage, or the first full car ( press save 2 key) save and then empty (press [save 2] key) storage, which means that after two (press save 2 key) save will constitute a complete set of records. Press [Save 2] key storage, in order to automatically identify the distinction between above , two kinds of storage, especially for the following agreements: ▲! The vehicle's license plate number must be any number between 00001 and 99999. That is to say 00000 can not be used as a real vehicle license plate number. If the license plate number is set to 00000 when you come to weighing a vehicle loading a cargo. At this point the indicator will be stored in accordance with the way.
▲! If the sign of the indicator peeled is lighting, tare known storage time will constitute a complete record. ▲! If the license plate number is set to 00000 other than any 5-digit, peeled and indicator identifier does not
shine (is Gross state) must be twice the storage operation can constitute a complete record.
▲! If you do not choose to use the license plate number, it is mean that do not weigh vehicles, one storage
will constitute a complete record. (4) Save operation method
Please check the appendix A detail for examples (5) When the data is unstable, or gross weight ≤ 0 or gross weight ≤ net weight or does not meet the return to zero conditions, can not be stored, otherwise the indicator display [ Err 19] in order to prompt the operator (6) About auto save and print ① Please check the print setting chapter for the setting of Auto save print ② when auto save print, do not have 2 save ways. ③ when auto save, the saved car No., cargo No. is the setted well ones before saving ④ There are 3 conditions for the auto save tare weight value:
a) When the peeled mark of indicator is lighting, store the group record as the tare weigh value b) When the peeled mark of indicator is not lighting, automatically find the tare weigh value below
this car No. in ram, save this tare weigh value to this group record.
c) When the peeled mark of indicator is not lighting, and there is no tare weight value in ram, will
save in the group record as the cargo form.
3.2The input method of tare weight save
The indicator can store 1500 tare values of vehicle number. There are 3 methods to input.
1. Input tare with number key: (*: original value)
Mark:step 2:PressCLEAN,if has this vehicle number,when delate,will showPASS
2. Save tare by weighing: Under the weighing status, place the empty vehicle on the scale. Wait until the scale is stable, press【V.N
and input the vehicle number, and then pressPRESET.
3.3 The mothed for Vehicle tare checking and clear
3
step
operation
display
explain
1
presscheck
S-CodE
Enter password
2
press111111
S- - - - - -
fixed password111111
3
pressENTER
rEAd 00
Choose function number
4
press6
rEAd 06
choose 6to check vehicle tare
5
pressENTER
PEr ***
show store space usage percentage(store number/1000)
6
pressENTER
o *****
show first vehicle number
7
pressENTER
P******
show the checked vehicle tare
9
pressENTER
o *****
still show first vehicle number
Parameter or
Function Code
Paremeter or Function Type
00
General Form
01
Detail Form in Certain Date
02
Detail Form during Certain Period
03
Detail Form for Certain Vehile No.
04
Detail Form for Certain Cargo No.
Steps
Operation
Display
Explanation
1
PressForm
Pb 00
Choose total list form
2
PressEnter
Print
Begin printing the form. Back to the weighing status after printing
Steps
Operation
Display
Explanation
1
PressForm
Pb 00
2
Press01
Pb 01
press01”, choose some day detail list form
3
pressENTER
d00.00.00
Enter date
4
press【120520】
d12.05.20
For example 2012-05-20
5
PressEnter
Print
Begin printing the form. Back to the weighing status after printing
Mark:step 6 and 7:PressCLEAN,clear this vehicle tare; Press【←/→】,check the front and back vehicle tare.
3.4Print of weighing record
1 Printing parameter must be set correctly before printing. (Refer to the part of printing parameter setting of technical manual) 2 The storing and printing of the indicator are simultaneous. At the same time when a group of complete record is stored with【SAVE1】or【SAVE2】, it will be printed out. (If the printing setup is effective, namely the model of the printer is non-zero and printing while storing is selected) 3 If the weighing record is not printed successfully because of some reason (ex.: printer fault), after the fault is eliminated, pressREPRINTand print the record stored currently. 4 In the end of a period of weighing, may pressA.Pto print out the accumulated value. 5 If pressSAVE2and use the two-time storage (loaded after empty, or empty after loaded), during the first storing, because the record is not completed, the indicator displays【LoAd】for 1.5 seconds but does not print. However, if press【REPRINT】at this time, the incomplete record can still be printed out. The printing
result is as below: ① Serial number is 0; ② Gross weight and net weight are all 0; ③ Tare weight is the weight value displayed currently.
3.5 Statistical form printing
1. Total detail list Form
2.Some day detail list form
3.Some time detail list form
4
Steps
Operation
Display
Explanation
1
PressForm
Pb 00
2
press02
Pb 02
press02”, choose some time detail list form
3
pressENTER
d00.00.00
Enter start date
4
press40101
d12.05.20
For example 2012-05-20
5
pressENTER
d00.00.00
Enter end date
6
press40101
A12.05.20
For example 2012-05-20
7
PressEnter
Print
Begin printing the form. Back to the weighing status after printing
Steps
Operation
Display
Explanation
1
PressForm
Pb 00
2
press03
Pb 03
press03”, choose vehicle NO. detail list form
3
pressENTER
o 00000
Enter Vehicle number
4
press00123
o 00123
Vehicle number is00123
5
PressEnter
Print
Begin printing the form. Back to the weighing status after printing
Steps
Operation
Display
Explanation
1
PressForm
Pb 00
2
press04
Pb 04
press04”, choose cargo NO. detail list form
3
pressENTER
hn **
Enter cargo number
4
press123
hn 123
Cargo number is123
5
PressEnter
Print
Begin printing the form. Back to the weighing status after printing
rEAd 1
Check by Date
rEAd 2
Check by Vehicle No.
rEAd 3
Check by Cargo No.
rEAd 6
Check/clear vehicle No.’s tare
rEAd 11
check imperfect record by date
rEAd 12
check imperfect record by vehicle number
Step
Operation
Display
Explanation
1
Under Weighing Status PressCheck
S-CodE
Enter code
2
press111111
S- - - - - -
Fix code111111
3
PRESSENTER
rEAd 00
Choose function number
4
press1
rEAd 01
choose number 1,check the complete record
4.Vehicle No. detail list form
5.Cargo No. detail list form
3.6Inquiry and clear weighing record
3.6.1 Press 【Check】to check the memory contents in the indicator by different modes. Operation method are as follows: Press 【Check】 under weighing status (If check encrypt is selected, the indicator will display S-CodE】to ask to input the password. After the password is passed) the indicator will display rEAd 00】to ask to enter the inquiry mode.
Press 【Enter】after enter the inquiry mode and the indicator will prompt to enter the required conditions for the inquiry such as date, vehicle no., cargo no., customer no., remarks no. etc. After that it will display the required records one by one. when check the complete and uncomplete record, the newest record will be displaied.
3.6.2 Example for Inquiry Operation: ExampleInquiry according to the date, i.e, inquiry the complete records in certain date
5
as per date
5
PRESSENTER
no 0001
Show first record
6
PRESSENTER/↓】
d12.05.31
show first record date
7
PRESSENTER/↓】
t09.58.44
show first record date
8
PRESSENTER/↓】
o 12345
show first record vehicle number
9
PRESSENTER/↓】
hn 003
show first record cargo number
10
PRESSENTER/↓】
A001.200
show first record gross weight
11
PRESSENTER/↓】
t000.200
show first record tare
12
PRESSENTER/↓】
A001.000
show first record net weight
13
PRESSENTER/↓】
no 0001
Back to first record
Step
Operation
Display
Explanation
1
pressCLEAN
S-CodE
Enter code
2
press111111
S- - - - - -
Fix code111111
3
pressENTER
SurE 0
Choose function number
1.Delate all complete record and uncompleted record
2.Delate all vehicle number tare
3.Delate all uncompleted record
4
press1
SurE 1
Choose to delete all complete record and uncompleted record
5
pressENTER
---- PASS
Deleting. finished, return toweighing display
number
display
Explanation
1
【 ------- 】
please wait, the inner part of indicator is under calculating, don’t make any operation
2
Print
the data is connecting between indicator and printer.
3
Load
the first data storing between the 2 times of weighting
4
End
Operation end
5
PASS】
Setting changed successfully
6
Lo bAt
Low power, will power off
7
【 -】
Voltage is under 10.2V,please recharge in time
8
SAVE 】
Data saving
number
display
Explanation
1
Err 03
overloading warning, must unload all or part of loading.
2
Err 08
no record under this condition
3
Err 11
storing space is full with vehicle no., please delete part or all of stored tare
4
Err 12
can not print the form of record by mini printer.or POS
Note:step 5-step 12,if the current weigh record do not haveREPRINT,it will displayErr 17,otherwise, clear
the weigh record. If press【←】will check the latest full weigh record, press 【→】will check before full weigh
record. Step6:if pressclean,if the current weigh record still do not haveREPRINT,it will displayErr 17】,otherwise will clean all weigh record for this date.
3.7 Delate operation for weighing record and vehicle number tare
3.8. Inquiry and print
The indicator can print out the record which is being inquiried, the operation is as below: during inquiring and
when displaying any one record , press Reprint to print out this inquired record. The number is 0.
4. Information tips
4.1 normal information tips
4.2.wrong operation information tips:
6
5
Err 17
Parameter setting does not meet requirements, please refer to the related parameters input range
6
Err 19
Zero negative weighing or instability cannot print, do not meet back to zero conditions don't print; Storage of input parameter not meets the requirement; Discrepancy zeros conditions; Do not conform to the skin condition: unstable negative; no tare information when check vehicle number
7
Err 26
time to power off
8
Err 27
The testing time is end
9
Err 28
Print date of the storage of weighing less than has the record date
10
Err 30
11
ECC 01~16
N load cells communication wrong
12
ECCP 01~16
N digital load cells communication and security is not available
13
Err P
printer connection error, printer error or printer didn't have paper, please add paper or press weighing key to exit
number
display
Explanation
1
--S--
start work to zero
2
S-CodE
code111111
3
C-CodE
enter calibration code
4
d-CodE
enter trial deadline code
Step
Status
Operation
Display
Explanation
1
Vehicles to weigh in
Presspreset
P000.000
Tip input tare weight values 2
Input tare weight value
If the input [1000]
P001.000
3
Pressenter
- 1.000
Show the scale gross/net weight value, to
skin FuLiang logo.
Note: at this time to switch to display
meter net state (according to the net/gross can switch over the show state).
4
Waiting for stability
PressSave 1 OR PressSave 2
o *****
Display the original car number. Hint user
input new car number. Note: if user storage projects choose not to use the car number or in print control parameters choose not to enter in the car number (see
4.3.Other information tips
Appendix A: print operation for example:
In printing in the control parameters choose not to input car number, and money order, for in the operation
of the corresponding will print skip steps, use at the same time the current meter car number and money
order memory unit original data storage. If in the storage projects choose not to use car number or money
order, for in the print operation when also can skip the corresponding steps, and do not store and print the
corresponding project (as shown in the technical specifications chapter 6 and 6 Settings).
1. One manual operation preset tare print weighing list
7
chapter 3 "print parameter Settings" part), this step is not in the show car number and suggests the new car number input, directly to step 6
5
Input vehicle number
FOR Press 00123
o 00123
6
Pressenter
HN ***
Display the original cargo no. ask to user
enter new cargo number
7
Input money order
FOR input001
HN 001
Cargo number 001 8 Pressenter
PriNt
Print weighing list.
Step
Status
Operation
Display
Explanation
1
The goods pounds, for stability
PressSave 1
o *****
Display the original car number. Ask user
input new vehicle number
2
Input vehicle number
input00123
o 00123
Enter vehicle number,such as 00123 3
Pressenter
HN ***
Display the original cargo no. ask to user
enter new cargo number
4
Input money order
FOR input001 Pressenter
HN 011
5
PriNt
Print weighing list.
Step
Status
Operation
Display
Explanation
1
The empty vehicle is on weighing, for stability
PressSave 2
o *****
Display the original vehicle number. ask
user input new number.
2
Input car number
input00123
o 00123
If the new number is the same with
before vehicle number, do not need to enter new one.
3
Pressenter
HN ***
Display the original cargo no. ask user
input new cargo no.
4
Input money order
FOR input001
HN 011
5 Pressenter
LoAd
back to weighing state after 1.5 seconds
6
Heavy vehicle is on weihging, for stability
PressSave2
o *****
Display the original car number. ask user
input the vehicle number the same as "step 2"
7
Pressenter
HN ***
Display the original car number. ask user
input the vehicle number the same as "step 4"
8 Pressenter
PriNt
Print weighing list
Note:when the tare light is on,can go the step 4.do not need operate step1-3 each time.
2.One manual operation print weighing list
Note: when no this vehicle number tare, indicator will imprint the GW is current value, tare is 0.
3.two weighing print weighing list (namely first after the first car or empty car heavy weight after car, here to the former empty car for example)
Before use configuration for Auto print weigh list
The detail please check the《calibration manualChapter 6,section 6.,set Quto, Return to zero HL and minimum print weigh L.
8
No.
Date Time
Vehicle No.
Cargo No.
G.W. (t)
Tare (t)
N.W. (t)
0001
05 2006
00001
003
2.003
1.000
1.003
0002
05 2021
00123
004
1.000
1.000
0.000
0003
05 2041
00001
010
1.000
0.100
0.900
0004
05 2044
00001
001
1.000
0.100
0.900
0005
05 2045
00001
050
1.000
0.100
0.900
0006
05 2045
00002
06
1.000
0.100
0.900
Total: G.W.: 7.003 t N.W.: 4.603
Appendix BExamples of breakdown and statistic form
Breakdown ( total)
Applicable modelD2008type(H+HP+HP1+)
D2008type(D28+)
D2008type(20KB+20KBP+20KBP1+)
D2008type(20KC+20KCP+20KCP1+)
9
Loading...