The Model 2303/2304A Power Supplies provide
both voltage control and power consumption
monitoring for automated testing of portable,
battery-operated devices. These power supplies
are optimized for testing battery-operated, wireless communication devices such as cellular
phones that undergo substantial load changes
for very short time intervals. These power supplies exhibit outstanding voltage stability during
pulse load changes and can simultaneously
measure load currents, even if they are short
pulses. In addition, this family of power supplies
can sink current and, thus, take on the characteristics of a discharged, rechargeable batter
y for
testing chargers and charger-control circuitry.
Output Capacity
5A
Both the 100W Model 2304A and the 45W Model
2303 can supply 5A (at 20V for the Model 2304A
and 9V for the Model 2303) to serve the peak
pulse loading requirements of battery-operated
devices. In both instruments, the maximum current of 5A can be delivered continuously. The
Model 2304A can supply up to 20V DC while the
Model 2303 can supply up to 15V.
Fast Response to Load Changes
Keithley’s High Speed Power Supplies are
Model 2303 or 2304A rear panel
designed to simulate the current drive capacity of
a battery. The power supplies simulate a battery’s
response during a large load change by minimizing the maximum drop in voltage and recovering to
within 100mV of the original voltage in 40µs or less.
When a portable device such as a cellular phone switches from standby mode to the full power mode
of operation, the current draw on the power supply can change by as much as 1000%. While a battery’s voltage will decrease by the value of the voltage drop across the battery’s low internal resistance, a conventional power supply will have a significant voltage drop (more than one volt) and take
milliseconds to recover to the original voltage level. F
or portable devices that operate at full power
only for short intervals, the full power event is over before a conventional power supply can recover.
For example, cellular phones designed in accordance with the GSM cellular phone standard transmit
and receive information in 576µs pulses. If the
power supply used to test them cannot recover
quickly enough, the performance of the device-
-test will be compromised by the power
under
supply. If the power supply voltage drops below
the threshold of the phone’s low-battery detection circuitr
y for a sufficient amount of time, the
phone will turn off during testing, giving a false
indication of a failed device.
The Models 2303/2304A
’s fast transient response
to large load changes will enable test engineers
to test their portable products properly and
eliminate false failures due to conventional
power supplies with slow response times. In this
eithley’s High Speed P
K
response with 4.5m (1
1
Ω/lead between source and G
ower Supply
5 ft) of cable and
ransient
. T
SM phone load.
way, the power supplies ensure maximum production throughput when testing portable
devices.
Fast transient response power supplies
1.888.KEITHLEY (U.S. only)
www.keithley.com
A GR
TER M
EA
EASU
RE OF CONFIDENCE
CIALIZED POWER SUP P LIES
E
SP
Trigger
Level
33.3µs
HighLow
Average
t
1
t
2
Low
High
Average
I= q(t)dt
t
1
t
2
2303, 2304AHigh Speed Power Supplies
DVM
+
-
+
-
V
out
V
in
0–20V DC
Ordering Information
2304A
High Speed Precision Readback
ower Supply (100W)
P
2303
High Speed Precision Readback
Power Supply (45W)
2303-PJ
High Speed Precision Readback
Power Supply (45W, 500mA
range replaces 5mA range)
Extended warranty, service, and
calibration contracts are available.
Accessories Supplied
User and service manuals,
CS-846 output connectors mating
terminal
Fast transient response power supplies
F
ast Measurements for
Power Consumption Analysis
As manufacturers of portable devices strive to
extend battery life and the length of time
between recharges, power consumption has
become an important performance indicator.
Therefore, in production testing, accurate peak
power and average power measurements are critical. These measurements are complicated by the
fact that wireless telecommunication devices
draw full load current in short pulses. The Models 2303/2304A’s pulse readback measurement
mode makes it possible to capture peak and average values on pulses as short as 60
µs. This allows
the power supply to power a device-under-test
and determine its current consumption to qualify
the device for its specified power consumption.
In addition to making measurements on short
pulses, the 2303/2304A power supplies can
measure a current pulse peak or a current pulse
train that is as long as 833ms. For random pulse
trains that have periods longer than 833ms, the
power supplies have a special long integration
mode that can make an average current measurement on up to 60s of data. To capture low
current pulses from very low power devices, the
Model 2303-PJ provides pulse measurement on
both the 5A and 500mA ranges.
Accurate Low Current Measurements
The Models 2303/2304A are well-suited for making fast, accurate measurements of sleep and
standby mode currents because they are based
on Keithley’s expertise in low current measure-
Model 2303/2304A
Block Diagram showing DC DVM measurement capability
ment technologies. With 100nA resolution, the
power supplies offer the precision needed to
monitor the low sleep mode currents in today’s
products and in future products. They can also
measure these low currents with 0.2% basic
accuracy.
High Current Sinking Capacity
Keithley’s power supplies can act as an electronic load and sink as much as 3A (Model 2304A)
and 2A (Model 2303), so they can simulate a discharged rechargeable battery. Therefore, they
can be used to verify the performance of a
portable device’s charger. The power supplies’
current dissipation capacity allows them to test
even high-current fast chargers.
Independent Digital Voltmeter Inputs
While many programmable power supplies offer
output readback capabilities, Keithley’s power
supplies are the only instruments available that
also offer a set of DVM inputs. These inputs allow
the Model 2304A to measure signals from 0 to
+20V (0 to +15V for the Model 2303) anywhere
in the test system with the same rated accuracy as
the voltage readback. The DVM and the power
source can operate simultaneously. For many
applications, the power supplies’ built-in DVM
eliminates the expense and space that a separate
voltage measurement instrument would require.
Remote Display Option
If the Model 2303 or 2304A must be mounted in
a location in which the display is not readily visible, an optional Model 2304-DISP Display
Module can be mounted at a more convenient
point, then plugged into the power supply unit.
The display module also includes all instr
ument
controls, so that the power supply can be oper
ated remotely from the more accessible location.
-
1.888.KEITHLEY (U.S. only)
SPECIALIZED POWER SUP PLIE S
www.keithley.com
The Models 2303/
2304A perform
a continuous integration to make peak,
average, and baseline
measurements on
complex load current
waveforms. Integration times can be
programmed with
33.3µs resolution.
A GREATER MEASURE OF CONFIDENCE
ACCESSORIES AVAILABLE
2304-DISPRemote Display
CABLES
7007-1Shielded IEEE-488 Cable, 1m (3.3 ft)
7007-2
-182
SC
RACK MOUNT KITS
4288-1Single Fixed Rack Mount Kit
4288-2
ER
TH
O
2303-EW
2304-EW1 Year Warranty Extension
2304A-EW1 Year Warranty Extension
KPCI-488IEEE-488 Interface/Controller for the PCI Bus
KUSB-488IEEE-488.2 USB-to-GPIB Interface Adapter
2303-PJ: 5A range: 100µA.500mA range: 10µA.
CURRENT SINK CAPACITY: 0–5V: 2A max. 5V–15V: Derate 0.1A per volt above 5V.
LOAD REGULATION: 0.01% + 1mA.
LINE REGULATION: 0.5mA.
STABILITY4: 0.01% + 50µA.
100µA.5mA range:0.1µA.
5
.
DIGITAL VOLTMETER INPUT (2 Years, 23°C ± 5°C)
INPUT VOLTAGE RANGE: 0 to +20V DC.
INPUT IMPEDANCE: 1010Ω typical.
MAXIMUM VOLTAGE (either input terminal) WITH RESPECT TO OUTPUT LOW: –3V, +22V.
READING ACCURACY1: ±(0.05% + 3mV).
READING RESOL
NOTES
1
PLC = 1.00.
2
Following 15 minute warm-up, the change in output over 8 hours under ambient temperature, constant load, and
line operating conditions.
3
Remote sense, at output terminals, 1000% load change; typical.
4
Remote sense, with 4.5m (15 ft) of 16 gauge wire and 1Ω resistance in each source lead to simulate typical test envi
ronment, up to 1.5A load change.
5
Minimum current in constant current mode is 6mA.
6
60Hz (50Hz).
7
PLC = P
8
Display off.
9
Speed includes measurement and binary data transfer out of GPIB.
UTION:
ower Line Cycle. 1PLC = 16.7ms for 60Hz operation, 20ms for 50Hz operation.
1mV
.
DC GENERAL
MEASUREMENT TIME CHOICES: 0.01 to 10 PLC7, in 0.01PLC steps.
AVERAGE READINGS: 1 to 10.
READING TIME
1, 8,9
: 31ms, typical.
PULSE CURRENT MEASUREMENT OPERATION
TRIGGER LEVEL:
2303:
5mA to 5A, in 5mA steps.
2303-PJ: 5A Range: 0mA to 5A, in 5mA steps.
RIGGER DELAY:0to 100ms, in 10µs steps.
T
NTERNAL TRIGGER DELAY:25µs.
I
IGH/LOW/AVERAGE MODE:
H
M
A
BURST MODE:
Measurement Aperture:
C
N
Tr
LONG INTEGRATION MODE: Measurement Time6: 850ms (840ms) to 60 seconds in 16.7ms
(20ms) steps.
ISOLATION (low-earth): 22V DC max.
PROGRAMMING: IEEE-488.2 (SCPI).
USER-DEFINABLE POWER-UP STATES: 5.
REAR PANEL CONNECTOR: 8-position quick disconnect terminal block for output (4), sense
TEMPERATURE COEFFICIENT (outside 23°C ±5°C): Derate accuracy specification by (0.1 ×
OPERATING TEMPERATURE:
STORAGE TEMPERATURE: –20° to 70°C.
HUMIDITY: <80% @ 35°C non-condensing.
POWER CONSUMPTION: 150VA max.
REMOTE DISPLAY/KEYPAD OPTION: Disables standard front panel.
DIMENSIONS: 89mm high × 213mm wide × 360mm deep (31⁄2 in × 81⁄2 in × 143⁄16 in).
SHIPPING WEIGHT: 5.4kg (12 lbs).
INPUT POWER:100V–240V A
WARRANTY: Two years parts and labor on materials and workmanship.
EMC: Conforms with European Union Directive directive 89/336/EEC EN 55011, EN 50082-1,
SAFETY: Conforms with European Union Directive 73/23/EEC EN 61010-1.
AC
-
REL
00mA Range: 0mA to 500mA, in 0.5mA steps.
5
easurement Aperture Settings:
verage Readings:1to 100.
onversion Rate:3600/second, typical.
umber of Samples:1to 5000.
ansfer Samples Across IEEE Bus in Binary Mode:
3.3µs to 833ms, in 33.3µs steps.
3
33.3µs.
GENERAL
(2), and DVM (2).
specification)/°C.
0° to 35°C (Full power).
0° to 50°C (Derate to 70%).
C, 50 or 60Hz (auto detected at power-up).
EN 61000-3-2 and 61000-3-3, FCC part 15 class B.
C, typ.; 600µA @ 220VAC, typ.
A
@ 110V
:
LINE LEAKAGE CURRENT
Y CONTROL J
A
available on jack. Accepts 0.173 in Bantam-type plug (C
ACK:
A
µ
450
1-channel, sink 150mA max., 15V max. 5V
4800 bytes/second, typical.
output, 100mA
S-1003-1).
Model 2303, 2303-PJ specifications
max., also
1.888.KEITHLEY (U.S. only)
www.keithley.com
A GR
TER M
EA
EASU
RE OF CONFIDENCE
SPECIALIZED POWER SUP PLIE S
2304A
High Speed Power Supplies
DC VOLTAGE OUTPUT (1 Year, 23°C ± 5°C)
OUTPUT VOLTAGE:
to +20V DC (for Normal Output Response).
0
to +15V DC (for Enhanced Output Response).
0
UTPUT ACCURACY:±(0.05% + 10mV).
O
ROGRAMMING RESOLUTION:5mV.
P
EADBACK ACCURACY
R
EADBACK RESOLUTION:1mV.
R
1
(0.05% + 10mV).
: ±
OUTPUT VOLTAGE SETTLING TIME: 5ms to within stated accuracy.
LOAD REGULATION: 0.01% + 2mV.
LINE REGULATION: 0.5mV.
STABILITY2: 0.01% + 0.5mV.
TRANSIENT RESPONSE TO 1000% LOAD CHANGE:
NORMAL MODE:
ransient Recovery Time
T
NHANCED MODE:
E
ransient Recovery Time
T
ransient Voltage Drop:
T
REMOTE SENSE: Automatic, 2V max. drop in each lead. Add 2mV to the voltage load regulation spec-
ification for each 1V change in the negative output lead due to load current change.
DC CURRENT (1 Year, 23°C ± 5°C)
Model 2304A specifications
3
50µs to within 100mV of previous level.
:<
100µs to within 20mV of previous level.
<
3,4
40µs to within 100mV of previous level.
:<
to within 20mV of previous level.
80µs
<
100mV, typical.
<
<200mV,
typical.
3
4
OUTPUT CURRENT: 5A max. (not intended to be operated in parallel).
COMPLIANCE ACCURACY: ±(0.16% + 5mA)
INPUT VOLT
INPUT IMPEDANCE: 1010Ω typical.
MAXIMUM VOLTAGE (either input terminal) WITH RESPECT TO OUTPUT LOW: –3V, +22V.
READING ACCUR
READING RESOLUTION: 1mV.
AGE R
ACY
1
: ±
0 to +20V DC.
(0.05% + 10mV).
DC GENERAL
MEASUREMENT TIME CHOICES: 0.01 to 10 PLC7, in 0.01PLC steps.
AVERAGE READINGS: 1 to 10.
READING TIME
1, 8,9
: 31ms, typical.
PULSE CURRENT MEASUREMENT OPERATION
TRIGGER LEVEL: 5mA to 5A, in 5mA steps.
TRIGGER DELAY: 0 to 100ms, in 10µs steps.
INTERNAL TRIGGER DELAY: 25µs.
HIGH/LOW/AVERAGE MODE:
Measurement Aperture Settings:
Average Readings: 1 to 100.
BURST MODE:
Measurement Aperture:
onversion Rate:3600/second, typical.
C
umber of Samples:1to 5000.
N
Transfer Samples Across IEEE Bus in Binary Mode: 4800 bytes/second, typical.
LONG INTEGRATION MODE
(20ms) steps.
ISOLATION (low-earth): 22V DC max.
PROGRAMMING: IEEE-488.2 (SCPI).
USER-DEFINABLE POWER-UP STATES: 5.
REAR PANEL CONNECTOR: 8-position quick disconnect terminal block for output (4), sense
(2), and DVM (2).
RELAY CONTROL JACK: 2-channel, sink 150mA max., 15V max. Accepts 0.173 in Bantam-type
plug (CS-1003-1).
TEMPERATURE COEFFICIENT (outside 23°C ±5°C): Derate accuracy specification by (0.1 ×
specification)/°C.
OPERATING TEMPERATURE:
0° to 50°C (50W10normal response, 25W10enhanced response).
0° to 35°C (100W
1
0
normal response, 75W
STORAGE TEMPERATURE: –20° to 70°C.
HUMIDITY: <80% @ 35°C non-condensing.
POWER CONSUMPTION: 200VA max.
REMOTE DISPL
AY/KEYPAD OPTION:
DIMENSIONS: 89mm high × 213mm wide × 360mm deep (31⁄2 in × 81⁄2 in × 143⁄16 in).
SHIPPING WEIGHT: 5.4kg (12 lbs).
INPUT POWER: 100V–240V AC, 50 or 60Hz (auto detected at power
WARRANTY: One year parts and labor on materials and workmanship.
EMC: Conforms with European Union Directive directive 89/336/EEC EN 55011, EN 50082-1,
EN 61000-3-2 and 61000-3-3, FCC part 15 class B.
SAFETY: Conforms with European Union Directive 73/23/EEC EN 61010-1.
33.3µs to 833ms, in 33.3µs steps.
33.3µs.
1
1
: Measurement Time: 850ms (840ms) to 60 seconds in 16.7ms
GENERAL
1
0
enhanced response).
Disables standard front panel.
-up).
NOTES
1
PLC = 1.00.
2
ollowing 15 minute warm-up, the change in output over 8 hours under ambient temperature, constant load, and
F
line operating conditions.
3
Remote sense, at output terminals, 1000% load change; typical.
4
Remote sense, with 4.5m (15 ft) of 16 gauge wire and 1Ω resistance in each source lead to simulate typical test envi
ronment, up to 1.5A load change.
5
Minimum current in constant current mode is 6mA.
6
60Hz (50Hz).
7
PLC = Power Line Cycle. 1PLC = 16.7ms for 60Hz operation, 20ms for 50Hz operation.
8
Display off.
9
Speed includes measurement and binary data transfer out of GPIB.
10
Max. continuous.
11
60Hz (50Hz).
1.888.KEITHLEY (U.S. only)
SPECIALIZED POWER SUP PLIE S
www.keithley.com
A GR
-
EA
TER M
EASU
RE OF CONFIDENCE
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.