Keba Kemro NX 252/A Project Engineering Manual

Page 1
Kemro
NX 252/A
Ethernet PCI option module
Project engineering manual V1.03
Translation of the original instructions
Page 2
Document : V1.03 / article no.: 1000412 Filename : nx252apjen.pdf Pages : 21
© KEBA 2011 Specifications are subject to change due to further technical developments. Details presented may be subject to correction.
All rights reserved.
A: KEBA AG, Gewerbepark Urfahr, A-4041 Linz, Tel.: +43 732 7090-0, Fax: +43 732 7309-10, E-Mail: keba@keba.com D:
US:
CN:
www.keba.com
KEBA GmbH Automation, Leonhard-Weiss-Straße 40, D-73037 Göppingen, Tel.: +49 7161 9741-0, Fax: +49 7161 9741-40, E-Mail: keba@keba.com
KEBA Corp., 100 West Big Beaver Road, Troy, MI 48084, US, Tel.: +1 248 526-0561, Fax: +1 248 526-0562, E-Mail: usa@keba.com
Beijing Austrian KEBA Science and Technology Development Ltd., Room B516, Nan Xin Cang Tower, A22 Dong Si Shi Tiao, Dong Cheng District, Beijing, 100027, P.R. China, Tel. +86 10 6409-6592, Fax +86 10 6409-6312, E-Mail: china@keba.com
Page 3
NX 252/A Record of Revision
Record of Revision
Version Date Change in chapter Description changed by
1.00 02-2008 Newly created meis
1.01 04-2009 EC directives corrected hasl
1.02 08-2010 EC directives and standards, Declara­tion of conformity
1.03 08-2011 Introduction Hint "not for end customers" added, various minor up-
updated hasl
fstl
dates.
Project engineering manual V1.03 3
© KEBA 2011
Page 4
Page 5
NX 252/A

Table of Contents

Table of Contents
1 Introduction....................................................................................................................... 7
1.1 Purpose of the document........................................................................................ 7
1.2 Preconditions.......................................................................................................... 7
1.3 Intended use........................................................................................................... 8
1.4 Notes on this document.......................................................................................... 8
1.4.1 Contents of the document........................................................................ 8
1.5 Documentation for further reading.......................................................................... 8
2 Safety notes...................................................................................................................... 9
2.1 Representation........................................................................................................ 9
2.2 General safety instructions...................................................................................... 9
3 Description of the module............................................................................................. 11
3.1 Front view.............................................................................................................. 11
4 Installation instructions................................................................................................. 12
5 Connections and wiring................................................................................................. 15
5.1 Ethernet................................................................................................................. 15
5.1.1 Pin assignment....................................................................................... 15
5.1.2 Cable and plug specification.................................................................. 15
5.2 EMC and wiring guidelines.................................................................................... 15
6 Configuration.................................................................................................................. 16
7 Operating behavior......................................................................................................... 17
7.1 Start-up after Power-On........................................................................................ 17
7.2 Reset..................................................................................................................... 17
8 Disposal........................................................................................................................... 18
8.1 Disposal of the module.......................................................................................... 18
9 Technical data................................................................................................................. 19
9.1 Environmental conditions...................................................................................... 19
9.2 Interface to the CPU module................................................................................. 19
9.3 Ethernet interface.................................................................................................. 19
9.4 Mechanics............................................................................................................. 19
10 EC directives and standards......................................................................................... 20
10.1 EC directives......................................................................................................... 20
10.2 Standards.............................................................................................................. 20
10.2.1 General procedures and safety principles.............................................. 20
10.2.2 EMC guideline........................................................................................ 20
10.2.3 Electrical safety and fire protection........................................................ 20
10.2.4 Environmental and surrounding conditions............................................ 20
10.3 Standards for the American market...................................................................... 20
10.3.1 UL test for industrial control equipment.................................................. 20
Project engineering manual V1.03 5
© KEBA 2011
Page 6
Table of Contents NX 252/A
11 Declaration of conformity.............................................................................................. 21
Project engineering manual V1.036
© KEBA 2011
Page 7
NX 252/A Introduction

1 Introduction

1.1 Purpose of the document

This document describes the structure of the NX 252/A (Ethernet PCI option module).
Information
This manual is not adressed to end costumers! Necessary safety notes for the end costumer have to be taken into the costumer manual in the respective national language by the machine builders and system providers.

1.2 Preconditions

This document contains information for persons with the following skills:
Target group Knowledge and skills pre-requirement
Basic technical training (University of Applied Science/University level, engineering degree or corresponding professional experience).
Project engineer
Operator
Service technician
Knowledge in:
working mode of a PLC,
safety regulations,
the application.
Basic technical training (Vocational high school, engineering degree or corresponding professional experience).
Knowledge in:
safety regulations,
working mode of machine or plant,
principal functions of the application,
system analysis and troubleshooting,
setting options at the operating installations.
Basic technical training (Vocational high school, engineering degree or corresponding professional experience).
Knowledge in:
working mode of a PLC,
safety regulations,
working mode of machine or plant,
diagnosis possibilities,
systematic error analysis and rectification.
Project engineering manual V1.03 7
© KEBA 2011
Page 8
Introduction NX 252/A

1.3 Intended use

The NX 252/A may only be used for the types of use described in the technical descriptions and only in conjunction with recommended/approved third-party equipment/installations.
The NX 252/A has been developed, manufactured, tested and documented in accordance with the appropriate safety standards. Therefore, the products do not pose any danger to the health of persons or a risk of damage to other property or equipment under normal circumstances, provided that the instruc­tions and safety precautions relating to the intended use are properly observed.

1.4 Notes on this document

This manual is integral part of the product. It is to be retained over the entire life cycle of the product and should be forwarded to any subsequent owners or users of the product.

1.4.1 Contents of the document

Description of the Ethernet PCI option module NX 252/A
Use of the Ethernet PCI option module in CPU modules
Description of interface including EMC measures
Technical data

1.5 Documentation for further reading

The following documents are to be observed depending on the system solution used:
If you are using the KeStudio U2 tool suite:
Doc.No. Name Target group
DE: 65352
K2-200 automation system manual
EN: 65353
If you are using the KeStudio U3 tool suite:
Project engineer
Electrician
Programmer
Commissioning foreman
Service technician
Doc.No. Name Target group
Project engineer
DE: 1000868 EN: 1000869
System manual Kemro automation system
Electrician
Programmer
Commissioning foreman
Service technician
Project engineering manual V1.038
© KEBA 2011
Page 9
NX 252/A Safety notes

2 Safety notes

2.1 Representation

At various points in this manual you will see notes and precautionary warnings regarding possible hazards. The symbols used have the following meaning:
DANGER!
indicates an imminently hazardous situation which will result in death or serious bodily injury if the corresponding precautions are not taken.
WARNING!
indicates a potentially hazardous situation which can result in death or se­rious bodily injury if the corresponding precautions are not taken.
CAUTION!
means that if the corresponding safety measures are not taken, a potentially hazardous situation can occur that may result in property injury or slight bodily injury.
CAUTION
CAUTION used without the safety alert symbol indicates a potentially haz­ardous situation which, if not avoided, may result in damage to property.
This symbol reminds you of the possible consequences of touching elec­trostatically sensitive components.
Information
Useful practical tips and information on the use of equipment are identified by the “Information” symbol. They do not contain any information that warns about potentially dangerous or harmful functions.

2.2 General safety instructions

WARNING!
It is absolutely essential to observe the safety instructions in the system manual.
The module is defined as "open type equipment" (UL508) or as "offenes Betriebsmittel" (EN 61131-2) and must therefore be installed in a control cabinet.
Project engineering manual V1.03 9
© KEBA 2011
Page 10
Safety notes NX 252/A
CAUTION
Improper use of the assembly or the control system leads to irreparable dam­age!
Turn off the power supply before inserting or removing the module. Other­wise, the module can be destroyed or undefined signal states can lead to damage of the control system.
When removed from it's casing this module is sensitive to electrostatic dis­charge. Before handling the modules touch a grounded metal object in order to discharge any static electricity from your body.
Project engineering manual V1.0310
© KEBA 2011
Page 11
NX 252/A

3 Description of the module

The NX 252/A is a Ethernet PCI option module for inserting into CPU modules of the type CP 24x/x or CP 25x/x. The NX 252/A Ethernet PCI option module can be integrated into a 10Mbit/s as well as a 100Mbit/s Ethernet.
Information
The module’s functionality is only guaranteed if used within a CP 24x/x or CP 25x/x. The module is not designed for connection with foreign modules.

3.1 Front view

Description of the module
Fig.3-1: NX 252/A front view
Project engineering manual V1.03 11
© KEBA 2011
Page 12
Installation instructions NX 252/A

4 Installation instructions

The module has been designed for operation with CPU-module, where it is inserted into the PCI slot.
Fig.4-1: Use of a NX 252/A in a CPU module
Information
The Ethernet PCI option module may not be plugged or removed if the CPU module is activated.
Inserting an option module into slot
1) Turn off power supply
2) Remove dummy module
3) Insert module in the correct position (labelling right side) into the right-hand slot
Project engineering manual V1.0312
© KEBA 2011
Page 13
NX 252/A Installation instructions
Fig.4-2: Inserting the NX 252/A
Removing an option module:
1) Turn off power supply
2) Pull module out of the slot
3) Insert dummy module
Project engineering manual V1.03 13
© KEBA 2011
Page 14
Installation instructions NX 252/A
Fig.4-3: Removing the NX 252/A
Project engineering manual V1.0314
© KEBA 2011
Page 15
NX 252/A Connections and wiring

5 Connections and wiring

5.1 Ethernet

5.1.1 Pin assignment

Fig.5-1: Ethernet connection
Pin no. Signal designation Input / Output
1 Tr. Data + Transmit Data + Output 2 Tr. Data - Transmit Data - Output 3 Re. Data + Receive Data + Input 4 Bi-Data + n.c. --­5 Bi-Data - n.c. --­6 Re-Data- Receive Data - Input 7 Bi-Data + n.c. --­8 Bi-Data - n.c. ---

5.1.2 Cable and plug specification

Further information: See system manual.

5.2 EMC and wiring guidelines

Pay attention from the outset to careful wiring and shielding. Further information: See system manual.
Project engineering manual V1.03 15
© KEBA 2011
Page 16
Configuration NX 252/A

6 Configuration

No configuration is required for this module.
Project engineering manual V1.0316
© KEBA 2011
Page 17
NX 252/A Operating behavior

7 Operating behavior

7.1 Start-up after Power-On

The module is passive and is configured and activated through the HOST.

7.2 Reset

The module can be reset by the HOST without the HOST itself having to be reset.
Project engineering manual V1.03 17
© KEBA 2011
Page 18
Disposal NX 252/A

8 Disposal

8.1 Disposal of the module

CAUTION
Please observe the regulations regarding disposal of electric appliances and electronic devices!
The symbol with the crossed-out waste container means that electrical and electronic devices including their accessories must not be disposed of in the household garbage.
The materials are recyclable in accordance with their labeling. You can make an important contribution to protecting our environment by reusing, renewing and recycling materials and old appliances.
Project engineering manual V1.0318
© KEBA 2011
Page 19
NX 252/A Technical data

9 Technical data

9.1 Environmental conditions

Operating temperature: +5 °C to +55 °C Storage temperature: -40 °C to 70 °C Relative humidity of air: 10 % to 95 % (non condensing) Vibration resistance: according to EN 61131-2:2007 Shock resistance: according to EN 61131-2:2007

9.2 Interface to the CPU module

Interface type: Connection: CHAMP plug 30-pin Power supply: 5 V Power consumption (5 VDC): 2 W
Module recognition:

9.3 Ethernet interface

Ethernet interface: Galvanic isolation: Yes, signaling line Number: 1 Connection: Modular 8-pin plug (RJ45 plug)

9.4 Mechanics

Structure: Protection class: Weight: 23 g
Media Independent Interface
YES (Module given, YES/NO, no type recog­nized)
10/100 MBit/s LAN,
No casing; only front plate mounted on print When the module is plugged into CPU module,
then the CPU module conforms to IP 20
Project engineering manual V1.03 19
© KEBA 2011
Page 20
EC directives and standards NX 252/A

10 EC directives and standards

10.1 EC directives

Guideline 2004/108/EC EC guideline on electromagnetic compatibility Guideline 2002/95/EC RoHS guideline

10.2 Standards

To check the conformity of the system with the directives, the following non­binding legal European standards were applied:

10.2.1 General procedures and safety principles

EN 61131-1:2003
Programmable controllers - Part 1
Information
This product was developed for the use in industrial areas and can cause radio interference when used in residential areas.

10.2.2 EMC guideline

EN 61131-2:2007
Programmable controllers - Part 2

10.2.3 Electrical safety and fire protection

EN 61131-2:2007
Programmable controllers - Part 2

10.2.4 Environmental and surrounding conditions

EN 61131-2:2007
Programmable controllers - Part 2

10.3 Standards for the American market

10.3.1 UL test for industrial control equipment

UL 508, 2005
Industrial Control Equipment
Project engineering manual V1.0320
© KEBA 2011
Page 21
NX 252/A Declaration of conformity

11 Declaration of conformity

Project engineering manual V1.03 21
© KEBA 2011
Loading...