Dimensions
KeContact P30
Version with standard socket (Type 2)
Dimensions in mm.
KEBA AG, Gewerbepark Urfahr, 4041 Linz/Austria, Phone: +43 732 7090-0, Fax: +43 732 730910, kecontact@keba.com, www.keba.com/emobility
Page 2
Dimensions KeContact P30
Version with charging cable and hanger (Type 1 with fixed cable, Type 2 with fixed cable)
Dimensions in mm.
KEBA AG, Gewerbepark Urfahr, 4041 Linz/Austria, Phone: +43 732 7090-0, Fax: +43 732 730910, kecontact@keba.com, www.keba.com/emobility
Page 3
Technical data KeContact P30
Electrical data
Connection cross-section Minimum cross-section (depending on the cable and the laying system):
- 5 x 2.5 mm² (16 A nominal current)
- 5 x 6.0 mm² (32 A nominal current)
Supply terminals Connection line:
- Solid (min.-max): 0.2 – 16 mm²
- Flexible (min.-max): 0.2 – 16 mm²
- AWG (min.-max): 24 – 6 - Flexible (min.-max) with wire end sleeve
without/with plastic sleeve: 0.25 – 10 / 0.25 – 10 mm²
Supply terminals temperature rating 105°C
Nominal current
(configurable connection values)
Mains voltage (Europe) 230 V
Mains frequency 50 Hz / 60 Hz
Network configuration TT / TN / IT (P30 only)
Overvoltage category III according to EN 60664
Rated short-time withstand current < 10 kA effective value according to EN 61439-1
Fuse protection
(in domestic installation)
DC residual-current monitoring (P30 only) FI / RDCMB ≤ 6mA DC (integrated with corresponding
P30 device version) FI / RDCMB ≤ 6mA DC (integriert bei entsprechender P30 Geräte-Variante)
Socket versions Type 2 standard socket: 32 A / 400 V
Cable versions
(for rating see type plate)
Protection class I
IP protection rating for device IP54
Protection against mechanical impact IK08 (except for cylinder lock)
10 A, 13 A, 16 A, 20 A, 25 A or 32 A
3-phase or 1-phase
230/400 V 3N~ (excluding e-series)
The fuse protection must be implemented according to the locally valid
regulations, according to the socket versions / cable versions (see type plate).
according to EN 62196-1 and VDE-AR-E 2623-2-2
Type 1 cable: up to 32 A / 230 VAC according to EN 62196-1 and SAE-J1772
Type 2 cable: up to 32 A / 400 VAC according to EN 62196-1 and VDE-AR-E
2623-2-2
AC
Ambient conditions
Operating temperature at 16 A -25°C to +50°C without direct sunlight
Operating temperature at 32 A -25°C to +40°C without direct sunlight
Temperature behavior In each case, for the specified operating temperature ranges, the device provides
charging current continuously. To increase the charging availability, the charging
current specification is reduced to 16 A if the temperature is exceeded. The
charging procedure can also subsequently be switched off. After cooling down,
the charging current specification is increased again.
Storage temperature range -25°C to +80°C
Speed of temperature change max. 0.5°C/min
Permitted relative humidity 5 % to 95 % (non condensing)
Altitude max. 2000 m above sea level
KEBA AG, Gewerbepark Urfahr, 4041 Linz/Austria, Phone: +43 732 7090-0, Fax: +43 732 730910, kecontact@keba.com, www.keba.com/emobility
Page 4
Technical data KeContact P30
Interfaces
Enable input [X1] Enable input for external authorization:
Connection line:
- Cross section (min.-max): 0.08 – 4 mm²
- AWG (min.-max): 28 – 12
Potential-free switch contact output [X2] Safety extra-low voltage <50 V
External current limiting max. 0.5 A
Connection line:
- Cross section (min.-max): 0.08 – 4 mm²
- AWG (min.-max): 28 – 12
Ethernet2 connection (debug) [X3] RJ45
Ethernet1 connection [X4] LSA+ terminals
USB connection [X5] (P30 only) USB socket type A (max. 500 mA)
RFID (optional) MIFARE cards or tags according to ISO14443
Cylinder lock (optional) Profile half cylinder according to EN 1303 or DIN 18252
Length A=30 mm (31 mm)
50/60 Hz
AC
We reserve the right to make alterations in line with technical progress. Data provided without guarantee. All rights reserved. 1B - G7
Mechanical data
Dimensions (W x H x D) 240 x 495 x 163 mm (e.g. type 2 standard socket)
Weight approx. 4.8 kg (depending on device version) approx. 4.8 kg
(depending on device version)
CE Declaration of Conformity
2014/35/EU Low-voltage Directive
2014/30/EU Electromagnetic Compatibility Directive
2014/53/EU Radio Equipment Directive (RED)
2011/65/EU Directive on the restriction of the use of certain hazardous substances (RoHS)
2012/19/EU Directive for waste electrical and electronic equipment (WEEE)