KEBA 0003, 0005, 0002, 0004 User Manual

Kemro K2
Kemro UserID classic / eco
User Identification System
User's Manual V 1.01
Translation of the original manual
© KEBA 2008 Specifications are subject to change due to further technical developments. Details presented may be subject to correction. All rights reserved.
Document: version 1.01 / article no.: 1000731 Filename: kemro_userid_bden.doc, last saving on: 29. 4. 2008
A: KEBA AG, Gewerbepark Urfahr, A-4041 Linz Tel.: +43 732 7090-0, Fax: +43 732 7309-10, D: KEBA GmbH Automation, Leonhard-Weiss-Strasse 40, D-73037 Göppingen, Tel.: +49 7161 9741-0, US: KEBA Corp., 100 West Big Beaver Road, Troy, MI 48084, US,Tel.: +1 248 526-0561, Fax: +1 248 526-0562, CN: Beijing Austrian KEBA Science and Technology Development Ltd., Room B516, Nan Xin Cang Tower,
www.keba.com
E-Mail: keba@keba.com Fax: +49 7161 9741-40, E-Mail: keba@keba.com E-Mail: usa@keba.com A22 Dong Si Shi Tiao, Dong Cheng District, Beijing, 100027, P.R. China,
Telefon: +86 10 6409-6592, Fax: +86 10 6409-6312, E-Mail: china@keba.com
User Identification System History
History
Version Date Changes to chapter Description Author
V1.00 100408 New meis V1.01 290408 Various changes meis
User's Manual, Version: 1.01 3
© KEBA 2008
History Kemro UserID classic / eco
4 User's Manual, Version: 1.01
© KEBA 2008
User Identification System Contents
Contents
1
Introduction......................................................................................................................9
1.1 Purpose of the document.......................................................................................9
1.2 Target groups, pre-requirements ...........................................................................9
1.3 Intended use ........................................................................................................10
1.4 Notes on this document .......................................................................................10
1.4.1 Contents of document..............................................................................10
1.4.2 Not contained in this document................................................................10
1.5 Documentation for further reading .......................................................................11
2 Safety notes ...................................................................................................................12
2.1 Representation.....................................................................................................12
2.2 General safety instructions...................................................................................13
2.3 Personnel safety instructions...............................................................................14
2.4 Safety instructions for maintenance.....................................................................14
3 General product description.........................................................................................15
3.1 Versions...............................................................................................................16
3.1.1 Kemro UserID classic.....................................................................17
3.1.2 Kemro UserID eco............................................................................18
3.2 View of modules...................................................................................................19
3.2.1 Stand-alone version .................................................................................19
3.2.2 Integrable version (OEM).........................................................................20
3.3 Recommended transponder (RFID data carrier)..................................................22
3.4 Spare parts and accessories................................................................................23
3.4.1 Connection cable......................................................................................23
3.4.2 Data disc (transponders)..........................................................................23
3.4.3 Software...................................................................................................23
4 Mounting and installation instructions........................................................................24
4.1 Stand-alone version.............................................................................................24
4.2 Integrable versions (OEM)...................................................................................27
4.2.1 Antenna 1 - XE020_ANT-OEM (variants B-OEM and D-OEM)................28
4.2.2 Antenna 2 - X110_ANT-OEM (Versions A-OEM and C-OEM).................29
4.2.3 Evaluation unit without housing (versions A-OEM and B-OEM) ..............31
4.2.4 Evaluation unit with housing (versions C-OEM and D-OEM)...................32
5 Show, connections and wiring.....................................................................................33
5.1 Status LED...........................................................................................................33
5.2 Connections.........................................................................................................33
5.2.1 Kemro UserID classic (stand-alone) ................................................33
5.2.2 Kemro UserID classic C-OEM / D-OEM...........................................34
5.2.3 Kemro UserID eco (stand-alone).......................................................34
5.2.4 Kemro UserID eco C-OEM / D-OEM..................................................36
User's Manual, Version: 1.01 5
© KEBA 2008
Contents Kemro UserID classic / eco
5.2.5 Kemro UserID classic / eco A-OEM and B-OEM........................... 36
5.2.6 Antenna 1 (XE020_ANT-OEM) ...............................................................37
5.2.7 Antenna 2 (X110_ANT-OEM)..................................................................37
5.3 Shield clamp........................................................................................................ 38
5.3.1 Attaching the shield clamp.......................................................................38
5.4 Power supply....................................................................................................... 39
5.4.1 Kemro UserID classic...................................................................... 39
5.4.2 Kemro UserID eco............................................................................. 40
5.5 Serial interface RS-232 (Kemro UserID classic)......................................... 40
5.5.1 Kemro UserID classic and Kemro UserID classic C/D-OEM ..40
5.5.2 Kemro UserID classic A/B-OEM...................................................... 41
5.6 USB 2.0 interface (Kemro UserID eco).........................................................42
5.6.1 USB interface for Kemro UserID eco C-OEM / D-OEM ....................42
5.6.2 USB interface for Kemro UserID eco A-OEM / B-OEM.....................43
6 Installation ..................................................................................................................... 44
6.1 Requirements for the target system ....................................................................44
6.2 Installation with Microsoft Windows 2000/2003 Server/XP/XPemb/Vista........... 45
6.3 Installation with Microsoft Windows CE............................................................... 45
6.3.1 Integration into the Windows CE Image.................................................. 45
6.3.2 Later installation / installation outside the Windows CE image ...............46
6.3.3 Module settings for the operation with Windows CE............................... 47
7 Operating behavior .......................................................................................................48
7.1 Start-up behavior................................................................................................. 48
7.2 Behavior in operation ..........................................................................................49
7.2.1 Activation modes for status LED .............................................................51
7.2.2 Validity test.............................................................................................. 52
7.3 Range and detection...........................................................................................53
8 Demo application ..........................................................................................................54
8.1 Start-up operation................................................................................................ 54
8.1.1 Prerequisites............................................................................................54
8.1.2 Start-up operation of system ...................................................................55
8.2 Description of the function of the demo application............................................. 55
8.2.1 Application window..................................................................................55
8.2.2 Tab page Read/Write Binary Data........................................................... 57
8.2.3 Tab page Read/Write Euromap 65 Data................................................. 59
8.2.4 Tab Settings ............................................................................................60
9 Function interface of device driver ............................................................................. 63
9.1 Data format.......................................................................................................... 63
9.1.1 Euromap 65 Standard .............................................................................63
9.1.2 Binary format........................................................................................... 63
9.2 Data structure...................................................................................................... 63
9.2.1 Data structure TEuromapData................................................................. 64
9.2.2 Data structure TEuromapOEMData ........................................................66
9.2.3 Data structure TEuromapTime................................................................ 66
6 User's Manual, Version: 1.01
© KEBA 2008
User Identification System Contents
9.2.4 Data structure TFactorySettings...............................................................66
9.2.5 Data structure TModuleSettings...............................................................67
9.2.6 Data structure TRfidDeviceName.............................................................67
9.2.7 Data structure TRfidUid............................................................................68
9.2.8 Data structure for Callback.......................................................................68
9.3 Enumeration types...............................................................................................69
9.3.1 Call-up actions of the Event Callback.......................................................69
9.3.2 Operating state of the Status LED............................................................69
9.3.3 Color of the Status LED............................................................................69
9.4 Constants.............................................................................................................70
9.5 Functions..............................................................................................................71
9.5.1 Registration of an Event Callback............................................................71
9.5.2 Read out list of currently connected Kemro UserID modules..............72
9.5.3 Opening a connection to a Kemro UserID module..............................72
9.5.4 Closing a connection to an opened Kemro UserID module.................72
9.5.5 Controlling the LED of the Kemro UserID module...............................73
9.5.6 Reading out current settings of the Kemro UserID module.................73
9.5.7 New settings for the Kemro UserID module........................................ 74
9.5.8 Reading out the factory settings of the Kemro UserID module ...........74
9.5.9 Creating a list of currently recognized transponders................................74
9.5.10 Opening a connection to a specific transponder....................................75
9.5.11 Closing a connection to an opened transponder....................................75
9.5.12 Reading out data from a transponder.....................................................76
9.5.13 Writing data of a transponder.................................................................77
10 Diagnosis........................................................................................................................78
11 Maintenance and repair instructions...........................................................................79
11.1 Maintenance.........................................................................................................79
11.2 Repair...................................................................................................................79
11.2.1 Packaging, shipment..............................................................................79
12 Disposal..........................................................................................................................80
12.1 Disposal of the module.........................................................................................80
13 Technical data................................................................................................................81
13.1 Stand-alone versions...........................................................................................82
13.2 OEM versions.......................................................................................................82
14 EC directives and standards ........................................................................................83
14.1 EC Directives.......................................................................................................83
14.2 Standards.............................................................................................................83
14.2.1 R & TTE .................................................................................................83
14.2.2 Other Standards and recommendations ................................................83
14.2.3 Environmental and surrounding conditions............................................84
14.3 Standards for the American market .....................................................................84
14.3.1 UL test for industrial control equipment ..................................................84
14.3.2 FCC........................................................................................................84
User's Manual, Version: 1.01 7
© KEBA 2008
Contents Kemro UserID classic / eco
8 User's Manual, Version: 1.01
© KEBA 2008
User Identification System Introduction

1 Introduction

1.1 Purpose of the document

This document describes the products Kemro UserID classic and
Kemro UserID eco.
This manual enables the user to operate the above-mentioned products and integrate them into the existing control and visualization system.

1.2 Target groups, pre-requirements

This document is made for the following persons with adequate skill pre­requirements:
Target group Knowledge and skills pre-requirements
Project engineer
Operator
Service technician
Information To integrate the knowledge about RFID technology and the EUROMAP 65 standard. The
necessary information is provided in respective chapter.
Basic technical training (University of Applied Science/University level or corresponding professional experience),
Knowledge in:
working mode of a PLC,
safety instructions,
the application.
Basic technical training (Vocational high school, engineer training
or corresponding professional experience).
Knowledge in:
safety instructions,
working mode of machine or plant,
principal functions of the application,
system analysis and troubleshooting,
setting options at the operating installations.
Basic technical training (Vocational high school, engineer training
or corresponding professional experience).
Knowledge in:
working mode of a PLC,
safety instructions,
working mode of machine or plant,
Diagnosis possibilities,
systematic error analysis and rectification.
Kemro UserID
into an existing system does not require
User's Manual, Version: 1.01 9
© KEBA 2008
Introduction Kemro UserID classic / eco

1.3 Intended use

Kemro UserID is used in applications for user identification at industrial
plants and machines. The typical applications areas include injection mold­ing machines, robots, presses, machine tools, machines / systems in the foodstuffs/luxury foodstuffs and pharmacy industries and similar.
Kemro UserID was developed, manufactured, tested and documented in
accordance with the appropriate safety standards. Provided, therefore, that the instructions and safety precautions relating to the intended use are pro­perly observed, under normal circumstances the products do not represent any danger to the health of personnel or a risk of damage to other property or equipment.
Information
KEBA assumes no liability for damages resulting from non-observance of safety instructions or improper use.

1.4 Notes on this document

This manual is part of the product. It must be retained over the whole life­time and if necessary referred to subsequent owners or users of the prod­uct.

1.4.1 Contents of document

z Description of the product and its function z Installation guidelines (mounting, cabling) z Description of operating behavior z Description of an example application z Description of function interface z Technical data

1.4.2 Not contained in this document

z Description of the integration packages
Integration packages are collections of modules that assist with the in­tegration of the Kemro UserID products into the visualization system used on the customer side.
z Description of the Kemro.userID secure+ version
10 User's Manual, Version: 1.01
© KEBA 2008
User Identification System Introduction

1.5 Documentation for further reading

Doc.No. Description Target group
DE: 1000732 EN: 1000733
Kemro.userID secure+ User's manual
User's manuals Kemro.userID Integration package
Project engineer
Commissioner
Service technician
Project engineer
Commissioner
User's Manual, Version: 1.01 11
© KEBA 2008
Safety notes Kemro UserID classic / eco

2 Safety notes

2.1 Representation

At various points in this manual you will see notes and precautionary warn­ings regarding possible hazards. The symbols used have the following meaning:
DANGER!
!
!
indicates an imminently hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING!
indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION!
!
means that if the corresponding safety measures are not taken a poten-
tially hazardous situation can occur which, if not avoided, may result in property damage or slight bodily injury.
NOTICE
NOTICE used without the safety alert symbol indicates a potentially
hazardous situation which, if not avoided, may result in property dam­age.
This symbol reminds you of the possible consequences of touching
electrostatically sensitive components.
Information Information on use of equipment and useful practical tips is identified by the symbol "Information". "Information" items do not contain any information that draws attention to potentially dangerous or harmful functions.
12 User's Manual, Version: 1.01
© KEBA 2008
User Identification System Safety notes

2.2 General safety instructions

WARNING!
!
The following application areas are expressly excluded for Kemro
UserID:
Use in explosive or fire-risk areas
Use in mining
Outdoor use
Kemro UserID are not allowed to be used for safety-relevant applica-
tions or safety functions (e.g. shutdown in emergency).
Other products are to be used for the above applications! For further information, see EN 954-1 (EN ISO 13849-1).
CAUTION!
!
Arbitrary or unsanctioned modifications to the device are prohibited.
This leads to the expiration of the conformity with the legal regulations as well as loss of guarantee and warranty claims.
NOTICE
Kemro UserID corresp onds partially or completely to an "open type
equipment" (according to UL 508), depending on version, and must the­refore be installed in a control cabinet or suitable housing. Further information: See chapter Fehler! Verweisquelle konnte nicht ge- funden werden..
When removed from the rack, the integrable versions (OEM) are sensi-
tive to electrostatic discharge. Before handling the module, touch a grounded metal object in order to discharge any static electricity from your body.
User's Manual, Version: 1.01 13
© KEBA 2008
Safety notes Kemro UserID classic / eco

2.3 Personnel safety instructions

WARNING!
!
!
Danger of personal injury due to electric shock!
Supply the Kemro UserID exclusively from power sources that have
a protective low voltage (e.g. SELV according to EN 60950-1)
Connect only voltages and power circuits to connections, terminals
and interfaces up to 50 V rated voltage that have a secure disconnect for hazardous voltages (e.g. with sufficient isolation).
CAUTION!
Fire hazard with module failure!
Provide suitable fuses for the 24 V DC power supply of the final appli-
cation. The maximum allowable fuse is 10 A!

2.4 Safety instructions for maintenance

CAUTION!
!
!
Always turn off the power supply before mounting and dismounting the
Kemro UserID. Otherwise, the module can be destroyed or undefined
signal states can lead to damage of the control system.
CAUTION!
The device may only be opened by qualified personnel and only main-
tenance activities expressly approved by KEBA may be performed (see chapter “Service notes”).
Protective measures against electrostatic discharge must be used (elec-
trostatic wristband, service mat) when performing maintenance and service work.
Do not touch the parts on the modules unless it is unavoidable.
Turn off the power supply on the device before inserting or removing
the modules.
14 User's Manual, Version: 1.01
© KEBA 2008
User Identification System General product description

3 General product description

Kemro UserID is a system for easy and fast identification of users of in-
dustrial plants and machines. Process-related and frequent login and logoff operations can be carried out reliably and efficiently.
User data stored on a card are transferred via non-contact RFID technology to the control system of the plant or machine. The entry of passwords is no
longer necessary with Kemro UserID. This substantially increases the security and transparency of the machines and plants.
Kemro UserID is available in different versions (see chapter
therefore be used for variety of applications.
Next to the hardware components, Kemro UserID also contains device drivers for different operating systems. The device drivers have interfaces that are easy to use for integration with all common visualization systems. A pre-fabricated set of commands is available for user identification to facili­tate the integration into a system.
In addition to the device drivers, comprehensive integration packages are available for various, commercially available visualization systems. These integration packages contain custom-made components for the simple in-
tegration of the Kemro UserID modules in the various visualization sys­tems and present their versatile application options in an array of descrip­tive application examples.
Details: See manuals for Kemro UserID integration packages
V) and can
User's Manual, Version: 1.01 15
© KEBA 2008
General product description Kemro UserID classic / eco

3.1 Versions

The product versions are basically divided into the following two groups:
z "Stand-alone" versions:
All Kemro UserID stand-alone products are installed well protected in rugged and compact housings. Their integration is simple and just as problem-free with regard to retrofitting existing machines.
z Integrable versions (OEM):
For integrable Kemro UserID products, the installation is made di­rectly in the customer's system, without interfering edges or gaps, which effectively reduces contamination of the devices. The antenna for this is integrated directly in the housing of the machine or the visualization de­vice. All OEM versions are available with different antennae and with or with-
out metal housing.
The Kemro UserID product line consists of the following versions:
Stand-alone version Integrable version
Kemro UserID classic
Serial interface
Module and antenna in a common
housing
Rugged housing
(Front side: IP65)
Kemro UserID eco
USB interface
Module and antenna in a common
housing
Rugged housing
(Front side: IP65)
Kemro UserID classic OEM
Serial interface
For installation in machinery and
plants
Antennas can be remotely positioned
from the module
Kemro UserID eco OEM
USB interface
For installation in a machinery and
plants
Antennas can be remotely positioned
from the module
Information A further system version is
Kemro UserID secure+
. This additionally
offers a special encoding feature for increasing data security. This version is not described in this manual due to the technical differences (see chapter
Documentation for further reading).
16 User's Manual, Version: 1.01
© KEBA 2008
User Identification System General product description
3.1.1 Kemro UserID classic
Material No. Name Description
074223
074224
074225
074226
Kemro UserID classic
(IC 140/A)
Kemro UserID classic A-OEM
(IC 140/A-OEM)
Kemro UserID classic B-OEM
(IC 140/B-OEM)
Kemro UserID classic C-OEM
(IC 140/C-OEM)
RFID read/write unit
Stand-alone version with complete electronics in compact plastic housing
Serial interface
Connector plug: 9 pole D-SUB (fe-
male) and 2 pole male connector (supply)
without connection cable
RFID read/write unit
without sheet metal housing for evalu­ation unit
Serial interface
Antenna 2 (L x W = 50 mm x 30 mm)
Connecting plug: Terminal block
without connection cable
Shield clamp for the shield connection
(with fixing screw)
Connection cable evaluation unit – Antenna (coax cable and LED con­nection cable)
RFID read/write unit
without sheet metal housing for evalu­ation unit
Serial interface
Antenna 1 (L x W = 57 mm x 53 mm)
Connecting plug: Terminal block
without connection cable
Shield clamp for the shield connection
(with fixing screw)
Connection cable evaluation unit – Antenna (coax cable and LED con­nection cable)
RFID read/write unit
incl. sheet metal housing for evalua­tion unit
Serial interface
Antenna 2 (L x W = 50 mm x 30 mm)
Connecting plug: 9 pole D-SUB (fe-
male) and 2 pole male connector (supply)
without connection cable
Connection cable evaluation unit –
Antenna (coax cable and LED con­nection cable)
User's Manual, Version: 1.01 17
© KEBA 2008
General product description Kemro UserID classic / eco
Material No. Name Description
074227
Kemro UserID classic D-OEM
(IC 140/D-OEM)
RFID read/write unit
incl. sheet metal housing for evalua­tion unit
Serial interface
Antenna 1 (L x W = 57 mm x 53 mm)
Connecting plug: 9 pole D-SUB (fe-
male) and 2 pole male connector (supply)
without connection cable
Connection cable evaluation unit –
Antenna (coax cable and LED con­nection cable)
3.1.2 Kemro UserID eco
Material No. Name Description
074229
074230
074231
Kemro UserID eco
(IE 160/A )
Kemro UserID eco A-OEM
(IE 160/A-OEM)
Kemro UserID eco B-OEM
(IE 160/B-OEM)
RFID read/write unit
USB interface
Stand-alone version with complete
electronics in compact plastic housing
Connecting plug: USB Type B
without connection cable
RFID read/write unit
USB interface
Antenna 2 (L x W = 50 mm x 30 mm)
Connecting plug: Terminal block
without sheet metal housing for evalu-
ation unit
without connection cable
Connection cable evaluation unit –
Antenna (coax cable and LED con­nection cable)
RFID read/write unit
USB interface
Antenna 1 (L x W = 57 mm x 53 mm)
Connecting plug: Terminal block
without sheet metal housing for evalu-
ation unit
without connection cable
Connection cable evaluation unit –
Antenna (coax cable and LED con­nection cable)
18 User's Manual, Version: 1.01
© KEBA 2008
User Identification System General product description
Material No. Name Description
074232
074233
Kemro UserID eco C-OEM
(IE 160/C-OEM)
Kemro UserID eco D-OEM
(IE 160/D-OEM )
RFID read/write unit
USB interface
Antenna 2 (L x W = 50 mm x 30 mm)
Connecting plug: USB Type B
incl. sheet metal housing for evalua-
tion unit
without connection cable
Connection cable evaluation unit –
Antenna (coax cable and LED con­nection cable)
RFID read/write unit
USB interface
Antenna 1 (L x W = 57 mm x 53 mm)
Connecting plug: USB Type B
incl. sheet metal housing for evalua-
tion unit
without connection cable
Connection cable evaluation unit –
Antenna (coax cable and LED con­nection cable)

3.2 View of modules

3.2.1 Stand-alone version
Stand-alone version (Kemro UserID classic / eco)
User's Manual, Version: 1.01 19
© KEBA 2008
General product description Kemro UserID classic / eco
3.2.2 Integrable version (OEM)
3.2.2.1 Kemro UserID classic / Kemro UserID eco A-OEM
Scope of delivery:
z Read/write unit without sheet metal housing for the evaluation unit z Antenna 2 (L x W = 50 mm x 30 mm) z Connecting cable evaluation unit -> antenna z Shield clamp with fixing screw (shield connection)
Kemro UserID classic / Kemro UserID eco A-OEM
3.2.2.2 Kemro UserID classic / Kemro UserID eco B-OEM
Scope of delivery:
z Read/write unit without sheet metal housing for the evaluation unit z Antenna 1 (L x W = 57 mm x 53 mm) z Connecting cable evaluation unit -> antenna z Shield clamp with fixing screw (shield connection)
Kemro UserID classic / Kemro UserID eco B-OEM
20 User's Manual, Version: 1.01
© KEBA 2008
User Identification System General product description
3.2.2.3 Kemro UserID classic / Kemro UserID eco C-OEM
Scope of delivery:
z Read/write unit with sheet metal housing for the evaluation unit z Antenna 2 (L x W = 50 mm x 30 mm) z Connecting cable evaluation unit -> antenna
Kemro UserID classic / Kemro UserID eco C-OEM
Information The version
Kemro UserID eco OEM
Kemro UserID classic OEM
version by the different data interfaces.
only differs from the shown
3.2.2.4 Kemro UserID classic / Kemro UserID eco D-OEM
Scope of delivery:
z Read/write unit with sheet metal housing for the evaluation unit z Antenna 1 (L x W = 57 mm x 53 mm) z Connecting cable evaluation unit -> antenna
Kemro UserID classic / Kemro UserID eco D-OEM
Information The version
Kemro UserID eco OEM
User's Manual, Version: 1.01 21
© KEBA 2008
Kemro UserID classic OEM
version by the different data interfaces.
only differs from the shown
General product description Kemro UserID classic / eco

3.3 Recommended transponder (RFID data carrier)

Kemro UserID classic or Kemro UserID eco is for use with
ISO/IEC 15693 compatible transponders (tags) designed with at least 256 bit freely writable memory.
Transponders with the following transponder chips are approved:
z Tag-it HF I Plus (Texas Instruments) z Tag-it HF I Standard (Texas Instruments) z I-Code SLI SL2 ICS20 (Philips)
Different transponder designs can be obtained directly from KEBA. The cor­rect functioning of these transponders is guaranteed by KEBA through comprehensive system tests. For an overview of all available transponders, please see the chapter " If other transponders are to be used, these are to be approved by KEBA.
Data disc (transponders)".
22 User's Manual, Version: 1.01
© KEBA 2008
User Identification System General product description

3.4 Spare parts and accessories

3.4.1 Connection cable
Material No. Name Description
on request Serial data cable, 1 m D-Sub 9-pin plug/socket, 1 m 074212 Serial data cable, 3.6 m D-Sub 9-pin plug/socket, 3.6 m on request Serial data cable, 5 m D-Sub 9-pin plug/socket, 5 m 073384 USB data cable,
USB type A/type B, 2 m
070780 USB data cable,
USB type A/type B, 4 m
069145 USB data cable,
USB type A/type B, 4.6 m
Information To ensure a proper functioning, we recommend using the cables specified above.
USB-A-USB-B 2.0 m USB-A-USB-B 4.0 m USB-A-USB-B 4.6 m
3.4.2 Data disc (transponders)
Material No. Name Description
074665 XC140/A Check card transponder unprinted, 2kBit on request XC140/Z Check card transponder, printed (4-color), 2
074662 XC240/A Key ring transponder unprinted, 2kBit on request XC240/Z Key ring transponder, printed (4-color), 2 kBit 074710 XC340/A Wristband transponder unprinted, 2kBit on request XC340/Z Wristband transponder, printed (4-color), 2
3.4.3 Software
Material No. Name Description
074345
074346
kBit
kBit
Kemro UserID Device
driver CD-Rom
Kemro UserID Integration
packages CD-ROM
Device driver for the product line
Kemro UserID, suitable for instal-
lation in all Windows-based devel­opment environments.
Kemro UserID Integration pack-
ages for the easy installation in current visualization systems
User's Manual, Version: 1.01 23
© KEBA 2008
Mounting and installation instructions Kemro UserID classic / eco

4 Mounting and installation instructions

In order to guarantee the defined range of the antenna (see chapter Technical data) and ensure an error-free operation, observe the installation instructions listed in this chapter.
Information The range is largely dependent on the installation situation. (see chapter Range and detection)

4.1 Stand-alone version

NOTICE
The Kemro UserID stand-alone version is defined as "open type
equipment" (according to UL 508). After mounting the front side rates as part of the final casing to a "type 1" indoor use (according to UL 508) or the protection type IP65.
Dimensions:
77
57
12
53
38
54,4
24,1 10,5
4
38,5
Dimensions (in mm)
24 User's Manual, Version: 1.01
© KEBA 2008
25,1
34,6
User Identification System Mounting and installation instructions
57
Cut-Out
43
Dimension of the opening for the installation (in mm)
Information The edges of the opening must be deburred to prevent damage to the de­vice that might occur otherwise.
User's Manual, Version: 1.01 25
© KEBA 2008
Mounting and installation instructions Kemro UserID classic / eco
Installation
2
5
1
4
1. Create an opening with a size of 57 mm x 43 mm.
2. Remove the product from the packaging
3
3. Take off front cover (by pressing the clip 2 in the direction of the arrow)
4. Fit module (without front cover) in the opening 1.
Information The wall strength of the carrier material 5 can amount to 1.5 mm and 6 mm.
5. Press in the clip of the mounting bracket and hold pressed 2
6. Stick the front cover onto the module from the front side 3.
7. Tighten both retaining screws (max. 0.5 Nm) 4.
NOTICE
The housing can be damaged by tightening the retaining screws too
tightly.
26 User's Manual, Version: 1.01
© KEBA 2008
Loading...
+ 58 hidden pages