Keating GasGrid pre2000 Service Manual

MIRACLEAN
®
GAS GRIDDLE SERVICE MANUAL
KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL
1-800-KEATING
www.keatingofchicago.com
TABLE OF CONTENTS
SECTION I INTRODUCTION
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . .1-2
SECTION II INSTALLATION
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Damage During Shipment . . . . . . . . . . . . . . . . . . . .2
Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Leveling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Restraining Devices . . . . . . . . . . . . . . . . . . . . . . . . .3
Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Gas Leak Testing . . . . . . . . . . . . . . . . . . . . . . . . .3-4
SECTION III OPERATING
Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Conditioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5
Cooking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Griddle Surface . . . . . . . . . . . . . . . . . . . . . . . . . .5-6
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
SECTION IV MAINTENANCE
Warranty Repairs . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Preventive Maintenance . . . . . . . . . . . . . . . . . . . . .6
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Limited Calibration . . . . . . . . . . . . . . . . . . . . . . . . . .7
SECTION V SERVICE DIAGNOSIS
Trouble Shooting Chart . . . . . . . . . . . . . . . . . . . . . .8
SECTION VI PARTS LIST
Ordering Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Warning and Operating Plates . . . . . . . . . . . . . . . .8
Miraclean® Gas Griddle Assembly . . . . . . . . . . . . .8
Control Panel Assembly . . . . . . . . . . . . . . . . . . . . .9
Heating Element Assembly . . . . . . . . . . . . . . . . . .9
SECTION VII WIRING DIAGRAM
Gas Griddle Wiring Diagram . . . . . . . . . . . . . . . . .10
Warranty . . . . . . . . . . . . . . .Back Inside Cover Page
Warranty Card . . . . . . . . . . . . . . . . . . . . . . . . .Insert
GasGrid pre2000 0107
07/10
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
ii
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
IMPORTANT
IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUT OFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE.
POST THIS LABEL IN A
PROMINENT LOCATION ON
YOUR UNIT.
NOTE: As continuous product improvement occurs, specifications may be changed without notice.
1
I INTRODUCTION
MODEL VARIATIONS
Standard Griddles: Keating MIRACLEAN gas griddles are available in sizes ranging from 27" to 72" and in depths 24", 30", 33" and 36". The gas griddles are AGA, CSA, and NSF design certified.
SAFETY PRECAUTIONS
WARNING
THIS SYMBOL WARNS YOU THAT SERIOUS BURNS OR OTHER INJURIES MAY RESULT IF SAFETY INSTRUCTIONS ARE NOT FOLLOWED.
This service manual should be retained in a safe
place for future reference. The installation of your new griddle must conform to local codes or in the absence of local codes, with the current National Fuel Gas Code ANSI Z223.1 NFPA 54 (latest edition), Natural Gas Installation Code CAN/CGA­B149.1 or Propane Installation Code CAN/CGA­B149.2.
Your ventilation hood, when installed, must conform
to the current ANSI/NFPA 96 (latest edition).
No frame or restriction shall be constructed around
the lower part of the MIRACLEAN® that would restrict air movement into a MIRACLEAN® combustion area or prevent proper ventilation.
Keating gas griddles are designed to operate on the
gas fuel specified on the serial plate and must not be operated with another gas fuel. They cannot be converted to another gas fuel by turning or engaging a switch.
Your Keating MIRACLEAN® gas griddle is designed
to use only the type of gas indicated on the serial plate attached to the front of the MIRACLEAN®.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any appliance.
You will post, in a prominent location, instructions to be followed in the event the user smells gas. This information shall be obtained from your local gas supplier. You may use the yellow stick-on label temporarily until you receive the data from your local gas supplier.
IMPORTANT: In the event a gas odor is detected, shut down unit at main shut-off valve and contact the local gas company or gas supplier for emergency service.
You must maintain this appliance free and clear from
combustibles.
You must maintain the following minimum
clearances for combustible and noncombustible construction:
Clearances Combustible Noncombustible
Construction
Construction
Back 6" 0"
Right Side 6" 0"
Left Side 6" 0"
You must install this appliance at least 16 inches away from any open flame.
Adequate clearance for servicing and proper
operation must be maintained. Your Keating MIRACLEAN® is designed to be serviced from the front.
Keating commercial griddles are intended for other
than household use.
ALWAYS instruct new employees on proper griddle
operation.
A MIRACLEAN® griddle should be operated ONLY
by properly trained personnel.
ALWAYS turn griddle off each night.
ALWAYS disconnect fuel source before servicing.
NEVER leave a griddle unattended during operation.
NEVER move griddle when hot.
THIS GRIDDLE MAY NOT BE ALTERED, MODIFIED OR CHANGED IN ANY WAY.
The State of California enacted the California Safe drinking water and Toxic Enforcement Act of 1986, (Prop. 65), which “prohibits any person in the course of doing business from knowingly and intentionally exposing any individual to a chemical known to the State of California to cause cancer or reproductive toxicity without first giving clear and reasonable warning to such individuals.” The Governor’s Scientific Advisory Panel added carbon monoxide to the list of hazardous chemicals known to cause reproductive harm.
In order to establish full compliance with Proposition 65, we attached a yellow warning label to each gas fired griddle that Keating of Chicago, Inc. manufactures. Carbon monoxide would not be present in concentrations that would pose a “significant risk” to the consumer when the equipment is installed,
2
operated and maintained as follows:
Installed in accordance with all local codes, or in the
absence of local codes, with the current National Fuel Gas Code Z223.1 (latest edition). National Gas Installation CAN/CGA-B149.1, or the Propane Installation Code, CAN/CGA-B149.2.
Installed under a properly designed and operating
exhaust hood.
Connected to the type of gas for which the griddle is
manufactured.
Pressure regulator is installed in the appliance and
adjusted for the manifold pressure marked on the serial plate.
Adequate air supply to the unit.
In-line pressure regulator, not supplied by Keating,
must be installed outside the appliance.
The equipment is operated in the manner intended
using the proper utensils.
Keep the equipment clean and have it checked
periodically.
Burner air adjustments, mechanical maintenance
and repairs must be performed by qualified service personnel.
If the equipment is not installed, operated and maintained in accordance with the above, concentrations of carbon monoxide in excess of the established limits could be present in the kitchen environment.
ALL PERSONNEL IN THE WORK PLACE WHO MAY BE SUBJECT TO ANY EXPOSURE OF CARBON MONOXIDE MUST BE WARNED OF SUCH POSSIBLE EXPOSURE. THIS WARNING SHOULD BE CONVEYED IN A MANNER SO THAT IT IS CLEARLY UNDERSTOOD BY THE EMPLOYEE, AND THE EMPLOYEE SHOULD BE ASKED IF IN FACT HE OR SHE UNDERSTANDS THE CORRECT METHOD OF OPERATION OF THE EQUIPMENT AND THAT A RISK OF EXPOSURE EXISTS IF THE EQUIPMENT IN OPERATED IMPROPERLY.
WARNING
IF NOT INSTALLED, OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS, THIS PRODUCT COULD EXPOSE YOU TO SUBSTANCES IN FUEL OR IN FUEL COMBUSTION WHICH CAN CAUSE DEATH OR SERIOUS ILLNESS AND WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.
II INSTALLATION
This UNIT must be installed, inspected, calibrated and serviced by qualified and/or certified and licensed service personnel - you may void your Keating warranty if installation is not completed per local, national and Keating specifications. Contact your dealer for assistance.
INSTALLATION
Installation must conform with local codes or, in absence of local codes, with current National Fuel Gas Code ANSI Z223.1 (latest edition), Natural Gas Installation Code CAN/CGA-B149.1 or Propane Installation Code CAN/CGA-B149.2.
NOTE: NOT FOR OUTDOOR INSTALLATION
DAMAGE DURING SHIPMENT
The griddle has been assembled, tested and inspected at the factory. Upon arrival, the complete griddle should be checked for any damage that may have occurred during shipment.
The carrier is responsible for all damage in transit whether visible or concealed. Do not pay the freight bill until the griddle has been thoroughly checked for damage. If concealed damage is found later, contact the carrier immediately to file a claim.
What to do if equipment arrives damaged:
VISIBLE LOSS OR DAMAGE – Be certain to note this on the freight or express receipt and have it signed by the delivery person.
FILE CLAIM FOR DAMAGES IMMEDIATELY – Regardless of extent of damage.
CONCEALED LOSS OR DAMAGE – If damage is noticed when equipment is unpacked, notify the freight company immediately, and file a “concealed damage claim”. This MUST be done immediately. Be sure to retain the shipping container for inspection.
Keating does not assume responsibility for Loss or Damage incurred in transit.
POSITIONING
The griddle must be no closer than six inches (6") from any combustible material. The griddle must be placed under an exhaust hood with a fire retardant system. Your ventilation hood, when installed, must conform to ANSI/NFPA 96 (latest edition). ALL connections and placement must comply with local and national codes. It is the responsibility of the owner and local installer to comply with these regulations when installing the griddle.