INSTANT RECOVERY
®
FRYER
18 TS GAS
Thermostat shall be close range, hydraulic type and be
accurate to ±3°F from 300° to 350°F with a stainless steel
bulb. Application of this thermostat is patented by Keating.
Hi-Limit Control shall be manually resettable type with
stainless steel bulb.
100% Safety Shut Off shall be flame switch type with
combination control gas valve.
Melt Cycle to be standard on "TS" fryers, allowing the safe
melting of solid shortening. Fryer is to be left in the Melt
Cycle mode until oil completely covers heat transfer tubes.
Indicating Lights & Switches. Power on switch, push to light
switch, fry off melt switch, ready to fry light, over max temp
light.
Standard Accessories to include two timers (programmable
for three products each), one pair 4 mesh baskets, grid screen
over heat transfer tubes, drain clean out rod digital timers and
a sample of Keating Klenzer and Sea Powder.
Electrical Requirements: Supply Voltage 120V 60Hz.
Control Voltage 24V 60Hz. 120 VAC 9ft. (1.5 m) grounded
cord set provided.
Gas Requirements to install are
3
/
4" male NPT connection and
4" water column pressures natural and 10" for LP gas at the
fryer burner manifold. Supply pressure to fryers must be 7"
(natural gas) and 11" (LP) water column.
Special Order Options may include battery, common
manifold, rear drain, casters, cover, thermostat seal, portable
filter, central filter (CF18SE or above), Safe & Easy filter,
Instant-On
™
, full or triple size baskets, security package, spark
ignition, basket-lift, computer, and 2” drain valve (not
available on SE), and 17" flue riser.
DESCRIPTION:
The Keating Instant Recovery
®
18 TS Fryer consists of a frying
vessel 18" sq., having a splash deck and a splash back installed in a
cabinet equipped with gas burners and an automatic temperature
control mechanism, all arranged and designed for the proper frying of food.
SPECIFICATIONS:
Frying Vessel: shall be constructed from 18 gauge stainless
steel, shall have a shortening capacity of 68 pounds, shall be
equipped with four 18 gauge horizontal heat transfer tubes
spaced above the bottom of the vessel so that the bottom is
unheated and the food particles collecting in this bottom zone
are unheated and therefore do not carbonize. The frying vessel
shall be polished to inhibit carbon build-up and facilitate easy
clean-up. The heat transfer tubes shall be 3" wide and 5" high. The
bottom of the vessel shall slope toward the front where it shall be
equipped with a 1
1
/4" Teflon core 1/4 turn, drain valve, so arranged
that the shortening can be drained into a receiving vessel placed in
front of the fryer.
Splashdeck shall slope toward the shortening containing vessel.
The splash deck shall be made of 16 gauge 304 stainless steel.
Splashback shall be made of 18 gauge 304 stainless steel, shall
completely cover the sides of the flue.
Cabinet: shall be made of 18 gauge stainless steel. The cabinet
shall be rigid in construction and shall have four 8" adjustable
legs. A door made of 22 gauge 304 stainless steel shall cover the
front of the cabinet and shall extend from the bottom of the fryer to
the panel, and above the panel shall be a canopy. The door shall be
the full width of the cabinet. No additional space is required for the
door to open a full 90 degrees. A stainless steel flue deflector is
provided for installing onto the flue back.
Heat Transfer Tubes to be four, made of stainless steel
polished to a #7 mirror finish.
Oil BTU Ship
Model No. and Description Capacity Input Height Depth Width Wt.
18 TS Nat Gas 68 lbs. 134,000 461/2"32
1
/2"19
3
/8" 260 lbs.
18 TS LP Gas 68 lbs. 132,000 461/2"32
1
/2"19
3
/8" 260 lbs.
18 Safe & Easy - - 461/2"36
5
/8"19
3
/8"-
KEATING OF CHICAGO, INC.
Toll Free 1-800-KEATING
www.keatingofchicago.com
As continuous product improvement occurs, specifications may be changed without notice.
Printed in U.S.A. 18TS2009 3/09