Tanning timesPlease keep to the recommended tanning times.
See Section 9.1
TimerThe apparatuses may only be operated with safety timers which
comply with the corresponding standards.
KBL-Solarien AG recommends the following timer:
megaTimer KBL-Article No. 9100025000.
DisconnectingBefore opening the apparatus, switch off the fuses to disconnect
the system from the voltage supply!
Facial tanner
Do not operate the sunbed if a filter pane is defective.
Section 5.3
Shoulder tanner
Attention!
Technical
Parameters
Do not operate the shoulder tanner without lamp unit
Attention! High light intensity, do not look into the radiators!
The data indicated in the tanning schemes are based on the
assumption that both tubes and burners are replaced at regular
intervals. Section 5.4
When replacing tubes, remember to reset the CPI-control
system (Section: 8.2) and the counter of the tube service hours
(Section: 8.3).
Mains voltage
MechanicsThe canopy drive has to be serviced regularly with each tube
4
An FI protective switch is required in any case.
replacement.
This also includes the replacement of the drive rope after 3,000
hours of operation.
Section 5.8
Please also keep to the service cycles given in the service plan
(Section 2).
CleaningDo not use any cleaning agents other than the ones approved
by KBL Solarien AG. Section 5.1
Operation and Service megaSun 5600
2. Service Plan
Service intervals
For a safe operation of the sunbeds, regular service works are
essential and have to be documented. Cleaning works have to
be done when necessary and do not have to be documented.
Service hoursWhat has to be done?see
Every day Check the filling level of the condensate tank and empty it if
necessary.
100 Change or clean filter mats5.7
500 - 600Change burners
For inductive apparatuses:
•Change tubes
•Change starters
•Reset counter of service hours
For CPI-apparatuses (with burners) in Power-mode:
•Change tubes
•Reset counters (8.2.2)
•Reset counter of service hours
Check and grease ropes of the canopy drive 5.8
Check all inner tubes and – if necessary – change them.
Climatic apparatus:
• Clean heat exchanger
• Check the functioning of the condensate pump
600
Replace lamps of the shoulder tanner.5.5
5.4
5.10
800For CPI-apparatuses (with burners) in Eco-mode or for CPI-
apparatuses (without burners) in Power-mode:
•Change tubes
•Reset counters (8.2.2)
•Reset counter of service hours
1000For CPI-apparatuses (without burners) in Eco-mode with
megaSun CPI-tubes in Power-mode:
•Change tubes
•Reset counters (8.2.2)
•Reset counter of service hours
Replace aquaCool nozzles.
1200For CPI-apparatuses with megaSun CPI-tubes in Eco-mode
•Change tubes
•Reset counters (8.2.2)
•Reset counter of working hours
3000Replace all the ropes 5.8
5.4
5.15
5
Operation and Service megaSun 5600
3. Optional Equipment
Feature
aroma and
cabinBreeze
activeColorColour stimulation in red, green or blue
aquaCoolMisty water for refreshment
airConAir conditioning
CPIElectronic ballasts
megaVoice*Acoustic user guidance
MP3 sound box*With a 256MB-memory for music
Music systemAudio amplifier and audio switch
Channel selectnext track of the external music source
Waste air tube Ø 300 mm, 3 m
Central exhaust air
element
Warm air recirculation
legTanner
Fragrances in the sunbed and in the cabin
x-traTanShoulder tanner
* the music system should be present
6
Operation and Service megaSun 5600
4. Operation during the tanning session
General
information
When switching on the apparatus, the following information is
displayed for 2 seconds before the running text appears:
Firmware version of the display
Version of the control software
Sunbed type
Tube type
Running text
The start of the tanning program depends on the studio control
system. If a simple coin-operated system has been installed, the
tanning program is started by inserting coins or tokens. When
the warm-up time has elapsed the tanning lamps are turned on
automatically.
If the touch key “Start” is pressed during this warm-up time, the
lamps turn on immediately.
The facial tanners are always turned on only after a certain
delay.
Some of the basic features are set in service level I, such as
colour-stimulation, aroma therapy, time control etc. Studio staff
will set these options according to the customers’ wishes.
4.1 Operating panel
Illustr. 4-1 The main display with key numbers (aquaCool is configurated)
Main display The running text is displayed as long as the sunbed is in the
„waiting position“. When the coin-controlled signal appears, the
functions are displayed and the sunbed can be operated by
touching the corresponding keys. Any input will be confirmed by a beep tone.
Operation and Service megaSun 5600
7
A function is switched on by pressing the plus sensor, which is
also used to increase the output stepwise. To set the maximum
value (e.g. fan speed) the sensor field has to be pressed again
and again until the maximum value has been reached.
A function is switched off by pressing the minus sensor, which
is also used to decrease the output step by step. To set the
minimum value (e.g. volume) the sensor field has to be pressed
again and again until the desired value has been reached.
4.2 Functions
StartYou can use this touch key to switch on the apparatus during
the warm-up time.
If the tanning session has been interrupted by means of the
„Stop“ key, it can be continued after touching the „Start“ key
once again, provided the coin-operated counter has not run
down yet.
The numerical display shows the tanning time.
When the tanning time is over, the running text will appear
again.
StopBy pressing this touch field for at least 2 seconds you can
terminate the tanning session prematurely.
Running timeDuring the tanning program the running time is displayed in this
field.
When adjusting the volume, the value set between 0 ... 99 % will
be displayed in this field for a short time.
8
When adjusting the fan speed, the value set between 20 ... 99
% will be displayed in this field for a short time.
Operation and Service megaSun 5600
End of the tanning
session
As soon as the tanning time is over a program to shut down the
sunbed will be started:
•a soft voice reminds you of the end of the tanning session
and says good-bye,
•burners, tubes and the ventilation system will be reduced
step by step,
•the LEDs (in apparatuses with activeColor) will shine in
the colour adjusted for another 20 seconds.
Extended menu
Music channel* Air Condition* Colour
stimulation*
Aroma *
Acoustic user
guidance*
These double arrows point to some more menus which can be
activated by pressing the „+“ or „-„ keys above the double arrow
symbol.
The following menus are available which will be explained in
more detail below:
By calling up these additional menu functions you can see which
functions are activated after switching on the apparatus.
Special customer requests can be pre-selected in the service
menu (see Section 8.2 ff.)
Volume*
You can adjust the volume of the music by touching the „+“ and
„-„ keys. The volume will be displayed in the numerical field as a
value between 0 – 99 %.
Press the corresponding sensor key again and again until you
have reached the desired volume.
* this is only preset if the feature is ordered
Operation and Service megaSun 5600
9
aquaCool*
Off ON
Water tank is
empty
Here you can activate the aquaCool water-atomisation function (plus button, symbol flashes) or deactivate it (minus button,
symbol does not flash). Default setting at start: as defined on
service level I in the AAC/Aqua menu.
•
If the aquaCool supply is running low, the message Aqua low
is shown on the display between the tanning sessions. When
the message appears for the first time, the aquaCool supply
will last approx. another 2.5 hours of operation with aquaCool.
•
If the aquaCool supply is empty, the message Aqua 0% appears and the symbol is crossed out. If the system is to be
used without aquaCool, you can switch off the messages
and the symbol. For this purpose, set the submenu Aqua
to “OFF”. To reach this menu, proceed to the AAC menu on
service level II.
* this is only preset if the feature is ordered
10
Facial tanner/
Shoulder tanner
(optional feature)
The control of the shoulder tanner is coupled to the face tanner.
The shoulder tanner is switched on whenever the facer tanner is
activated but its power cannot be turned down. As soon as the face
tanner is switched off, the shoulder tanner is turned off as well.
Important: Do not operate the shoulder tanner without lamp
unit.
Level II Once the tanning program has been started, the facial
tanners are automatically switched on at maximum
setting.
Level ITo reduce the output to level I, use the field “–”.
This step is not available with megaSun 5600 Super,
Super Power and Ultra Power UV type 3.
Level 0 To switch off the facial tanners completely, touch the “–”
field again for at least 3 seconds.
By touching the “+” field you can switch the facial tanners on
again or you can increase their output.
When the system has been switched off, there will be a time lag
before you can switch it on again due to the necessary cooling
of the burners.
Operation and Service megaSun 5600
Body fanThe power of the body fan can be increased or reduced by
steps of 10 % by touching the fields „+“ or „–”.
After being switched on, the fan starts running at the power-level
value that has been entered for ACS/A.START on level II of the
service menu.
When changing the value, the current setting is displayed as a
two-digit number between “20%” (minimum) and “99%” (maximum) in the numerical field for a short time.
In order to switch off the body fan completely, press the “−" field
several times until the value of 20% appears. Then press the "–”
field once again and keep the key pressed for 0.5 seconds. After
a short time lag the body fan is then switched off.
The body fan can be switched on again at any time simply by
touching the “+” field.
Channel selection*
With the help of this system you can choose the audio source,
e.g. change the CD or go to the next piece of music (MP3).
The MP3-player is equipped with a 256MB-chip, which can take
the volume of the 3 music CDs.
The studio operator himself can choose the music and with the
computer he can load it to the chip. The MP3-player is designed
in such a way that you only have to change the chip for the mu-
sic. KBL delivers all the apparatuses with MP3-players with the
music of the CD „megaSun & friends“.
As an optional feature, the music of the MP3-player can be
turned on during the tanning breaks.
Tip: The music of the MP3-unit can only be controlled by one
audio source, i.e. either by the chip of the MP3-player or by an
external music source.
11
Operation and Service megaSun 5600
Air-conditioning*
This airCon function is only in
this level if the
aquaCool is activated.
Otherwise you will
find airCon one
level higher as
the picture shows
on the right hand
side.
By pressing the „+“ or „–” keys you can switch the air-
conditioning on or off during the tanning session. Once the air-
conditioning has been switched off, it can only be switched on
again after an interval of 3 minutes. A small star is displayed to
confirm this.
If the request to switch on the system is made earlier, it will be
registered (big star) and when the interval of 3 minutes is over it
will be executed automatically.
Exception
In case that the system has been switched off by means of the
coin-controlled system, it can be switched on again immediately.
Main display with air condition (aquaCool is not congurated)
* this is only preset if the feature is ordered
12
Colour
stimulation*
The colour of the colour stimulation can be selected by means
of the „+“ key or by the „ - “ key: Red- Green - Blue.
You can only switch on one colour, but you can switch them all
off (see Service level).
48 high-performance diodes for each colour (Red - Green Blue) produce the mood desired: relaxing blue, stimulating blue
and calming green.
Operation and Service megaSun 5600
Aroma*
The „aroma“ function can be switched on by means of the „+“
key above “1” and switched off by the „ - “ key below „0“.
The display flashes a signal when the function is not activated.
KBL can offer 2 aroma fragrances: „Sunrise“ and „Daydream“.
The apparatus only has one fragrance which can changed very
easily, however.
The fragrance is combined with a gel. Please note that the gel
is not completely used up but a small rest will remain. This status is shown on the display so that the operator knows when to
change the gel.
The fragrance comes out at the foot of the bed. The air stream
leads the fragrance over the body to the face so that it can be
perceived intensively.
aroma and aquaCool are activated one after the other
(aroma – aquaCool – aroma) and start again and again in an interval of 1 minute.
Tip: pureAir and aroma exclude each other. As long as aroma is
given off pureAir will be switched off.
megaVoice*
* this is only preset if the
feature is ordered
The „Voice“ function can be switched on by means of the „+“ key
above “0” and switched off by the „ - “ key below „1“.
The display flashes a signal when the function is not activated.
megaVoice informs the customer in a simple and short way
about the operating functions of the sunbed. If requested,
megaVoice can be switched off by the customer during the tanning session.
13
Operation and Service megaSun 5600
4.3 Tips for the studio operator
Daily checks and
basic settings
Illumination after
use
Please make sure
•that the tank for the condensed water is checked and
emptied every day (5.11)
•that materials which have been used up are refilled (8.4)
and
•that the settings which can be executed in the service
levels (8.2, 8.3) of operation, e.g. colour-stimulation,
aroma, time controls etc., are made.
The illumination (decorative) may be switched on or off if the
timer signal is not active by pressing the key sequence
„+“....„–”....“+“ of the body fan.
You have to press the individual buttons within a period of 1 sec.
Please also bear in mind the possibility of defining two different
illumination cycles for each day of the week (see 8.2.2).
14
Error message
„Abluft “ (exhaust
air)
This error message is shown in the display and can be
acknowledged by pressing the „Stop“ key.
But before doing so, service people should repair the defect.
Possible reasons of this message can be:
• the temperature in the apparatus is too high or
• the exhaust vent system is defective
For more information see 8.6
Operation and Service megaSun 5600
5. Maintenance of the sun bed
Preparatory worksBefore you open the apparatus, switch off the fuses to discon-
nect it from the mains supply!
Do not operate the tanning unit without the front panels, without
acrylic panes or with the base section opened, because otherwise the tanner areas will become overheated. This will destroy
the filter panes!
As far as CPI-equipped units are concerned, the electronic
switchboxes located under the bed are also exposed to the danger of overheating.
5.1 Cleaning and care
Plastic parts
Chromed parts
Acrylic panes
The bigger plastic parts are made of solid, high-quality ABS
material.
The surfaces and the acrylic glass must not be cleaned with
concentrated disinfectants or solvents or other liquids that
contain alcohol! The manufacturer cannot be held liable for
any damages caused by chemically active agents such as
inappropriate cleaning agents. To clean the varnished and plastic
surfaces use a damp soapy cloth.
It must be avoided at any rate that cleaning fluid runs into the
apparatus.
Clean only with a damp (not wet) washleather and a plexiglass
cleaner (antistatic). The cleaning agent must be applied onto the
cleaning cloth and not directly onto the chromed parts.
For a harmless cleaning of the acrylic panes use the special
cleaning and disinfectant fluid „megaClean “ (to be obtained
from KBL) which has to be diluted in water at a ratio of 1:13.
Fixing the canopyThe canopy can be fixed in the upper position, to perform
service and maintenance works.
To do so, turn the lever of the left hand side of the tanning
system to the left. Lift the canopy to the upper position and it
will remain in this position. To release the canopy again, turn the
lever to the right.
After removing the screws on the left and on the right, the bed
pane can be fastened to the canopy.
Operation and Service megaSun 5600
15
5.2 Dismantling the acrylic panes
Dismantling the
pane in canopy
and lateral part
StepProcedureReference
The following tables explain how to dismantle the acrylic panes.
1Fix the canopy. 10
2Remove the screws and tilt down the canopy and/or
lateral pane(s).
Illustr. 5-2
Illustr. 5-3
3When the pane is in the lower position, you can lift it out of
the swivel hinge support, if necessary.
4Mount the pane in reverse order. Make sure that the frame
is correctly positioned in the hinge.
5When closing the pane, all air nozzles must be matching
their counterparts. If not, carefully push the nozzles
concerned into their proper position.
6Release the canopy.
16
Illustr. 5-2 Release the four screws
of the canopy pane
Base and duct
pane
The following table shows how to clean the base and duct pane.
The electronic parts installed underneath the bed must not get in
contact with any moisture.
Therefore, in order to clean the underside of the base pane and
the inner base section, use a slightly damp micro fibre cloth
only. You can also use it to clean the shoulder tanner. You can
use megaClean as a detergent (spray the cloth with it).
Operation and Service megaSun 5600
Illustr. 5-3 Release the four screws
of the lateral pane
StepProcedureReference
1Fix the canopy.
2Undo the two pan-head screws on the right and on the
Illustr. 5-4
left-hand side of the base pane.
3Lift the base pane and fix it to the canopy by means of the
Illustr. 5-5
enclosed hooks.
4Clean the lower part of the base pane.
5If there is a duct pane in the bed, you can take it out for
Illustr. 5-6
cleaning purposes.
Carefully put the duct pane back into its correct position
for the proper cooling of the base pane!
Proceed in the same way with the shoulder tanner.
6Clean the upper surface of the base pane and fasten it
with the two screws.
Illustr. 5-4 Pan-head screwIllustr. 5-5 Suspension of the base pane
Illustr. 5-6 Duct pane
Operation and Service megaSun 5600
17
5.3 Filter panes
Safety function The facial tanners are equipped with an additional safety
function. Behind each of the filter panes there is a safety switch
that switches off the burner in the case of a missing or broken
pane.
Do not operate the tanning system with a defective filter pane.
Carry out regular visual inspections!
Filter panes have to be replaced only by those of the same type!
The filter panes may be dismantled and replaced by trained
expert staff only.
Filter panes in the
canopy or lateral
part
StepProcedureReference
1Dismantle the acrylic pane of the canopy or of the lateral
part.
2Undo the screws of the filter pane cover (1), swing it out (2)
and pull it out (3).
3Carefully and with both hands, press the filter pane down (4)
until the upper springs release the pane (5). Take the pane
out from above (6).
4After cleaning the pane, mount it again in reverse order.
After dismantling the filter panes (see below), clean them with a
standard cleaning agent for glass and a soft cloth or chamois.
see 5.2
Illustr. 5-7
Illustr. 5-8
1
3
2
18
1
56
3
Illustr. 5-7 Remove filter pane coverIllustr. 5-8 Remove pane from the
MarkThe filters are marked with
„KBL 3020 0191“
Operation and Service megaSun 5600
2
clamping springs
5.4 Tubes, facial and shoulder tanners
DismantlingCarry out the following procedure to clean or replace tubes or
face and shoulder tanners:
StepProcedureReference
1Dismantle the canopy pane, base pane and lateral pane. Section 5.2
2Remove the tube covers in the facial area. Section 3.3.
For apparatuses equipped with burners: You will have to
3
dismantle the filter panes as well, if you want to replace
the burner.
4Remove the covers of the shoulder tanners.
Cleaning intervals
To make sure that the tanning effect is maintained, we
recommend you to clean the tubes and UV radiators with warm
water and a chamois after approx. every 200 hours of use. Do
not use any aggressive or alcoholic cleaning agents.
Unit lighting
The coloured filter (Sec. 5.7 Unit lighting) has to be replaced at
the latest when replacing the tanning tubes.
Replacement
intervals
Only replace tubes, face tanners, shoulder tanners and starters
with those of the same type!
When installing the tubes, make sure that the inscription is
visible, i.e. the reflector must be at the back.
For units equipped with CPI technology, it is essential to carry
out a reset after each tube replacement! (see Section 8.2.2)
For units equipped with inductive technology also install new
starters when replacing the tubes!
After each change of tubes, do not forget to reset the counter of
the service hours of the tubes. (see Section 8.3.)
1Undo the screw that holds the outer covering. Lift the ou-
2Undo the screws of the chrome covering and pull it off
3
4
5
6
Every 600 hours of operation, the lamps of the shoulder tanner
have to be replaced. Let the tanning system cool down before you
replace the burner. Disassembly and assembly of the burners must
only be carried out by trained expert staff. The base pane must
remain tilted downwards during dismantling and re-assembly.
Important: Do not operate the shoulder tanner without lamp unit.
Illustr. 5-5-1
ter covering off in upward direction and towards the front.
Illustr. 5-5-2
towards the front.
Disconnect the reflector from the electrical system by
Illustr. 5-5-3
pulling the plug out of the ignition unit at the position
marked in the figure. Remove the reflector by pressing
Illustr. 5-5-4
it downwards vertically and then turning it to the left
while keeping it pressed down. Pay attention that you
do not twist the socket.
To spread the clamp, press one side downwards. Then
take hold of the socket of the burner on the opposite
side and pull it out in an inclined upward movement.
Illustr. 5-5-5
Burner and socket represent one single component.
When installing the new burner, be careful not to
touch the glass with your bare hands. This would
cause stains that burn in during operation. If you
happen to touch the glass, use alcohol to clean it
carefully. Press one side of the clamp downwards,
then take the new burner and place it into its exact
Illustr. 5-5-6
position by paying attention to the recess in the
socket. After that, press the socket downwards on the
opposite side until it locks into place.
Connect the plug to the ignition unit.
When installing the reflector, the wider part of the highgrade steel ring must be directed towards the centreline
of the shoulder tanner. Place the reflector in position
Illustr. 5-5-7
as shown in figure 5-6-7, then press it downwards and
turn to the right while keeping it pressed down. Pay
attention that you do not twist the socket.
Insert the chrome cover into the slots of the shouldertanner casing, press it down to ensure a snug fit and
7
screw it on. Position the reflector correctly under the
chrome covering. To do so, press the reflector slightly
to align it.
8Attach the outer covering vertically and tighten the screw.
Operation and Service megaSun 5600
Illustr. 5-5-8
Illustr. 5-5-1: Undo the screw holding
the outer covering
Illustr. 5-5-3:Disconnect the reflectors at the respective ignition unit
from the electrical system
Illustr. 5-5-2: Undo the screws holding the chrome covering
Illustr. 5-5-4: Unscrew the reflector
Illustr. 5-5-5: Spread the clamp and
take off the burner including socket
Flat projection
Illustr. 5-5-7: Insert the reflectorIllustr. 5-5-8: Reflector correctly posi-
Illustr. 5-5-6: Insert the new burner
and ensure a snug fi t
tioned under the chrome cover
Operation and Service megaSun 5600
21
5.6 Replacing the burners of the facial tanner
BurnersOnly trained expert staff is allowed to install or remove burners.
StepProcedureReference
1Remove the filter pane(s)Section 5.3
2Hold the burners with a soft cloth in order to push them to
one side and then pull them out towards the front.
3Do not touch the burner glass with your bare hands. If
necessary, you can clean the glass bulb with an alcoholic
cleaning agent.
Illustr. 5-12
Illustr. 5-13
22
Illustr. 5-12 Pushing the burner
sidewards
Installing the
burners
During service, dirt accumulation and an incorrect positioning
may lead to damages of lamps and sockets. Therefore, when
inserting the burners please make sure that the contact surfaces
of both sockets and burners are clean. Insert the burners in a
straight position into their sockets.
After being inserted into the socket, the little metal shackle in the
centre of the reflector should face the reflector.
Illustr. 5-13 Pulling the burner out
towards the front
Operation and Service megaSun 5600
5.7 Unit lighting
Coloured filter
The coloured filter has to be replaced at the latest when replacing the tanning tubes.
Replacing the
lighting system in
the canopy
StepProcedureReference
1Canopy:
Both in the canopy and in the lateral section, there is a coloured
lighting tube installed behind the tanning tubes. (see Table).
Section 5.2
Open the canopy pane and tilt it downwards.
2Remove the tanning tubes 5 and 6. Now you can
replace the tube.
3Re-install the tanning tubes and close the canopy.
4Lateral pane:
Section 5.2
Open the lateral pane and remove the two upper
tanning tubes. Now you can replace the tube.
5Re-install the tanning tubes and close the lateral pane.
Replacing the
unit lighting in the
lower front section
The tube in the lower front section is located in a protective
conduit, which has been screwed onto the tube sockets. Take
the opportunity to check the filter mat and to clean or replace it if
necessary.
StepProcedureReference
1Undo the two screws of the base pane and tilt the
pane upwards.
2Unscrew the protective conduit on both sides and
Illustr. 5-14
push it to the right (or to the left). Now you can replace
the tube.
3Close the base pane.
23
Illustr. 5-14 Unit lighting in the lower front section and the starter for this tube on the left side.
Operation and Service megaSun 5600
Canopy lightingmegaSun 5600: Below the canopy casing you will find two
energy saving lamps and a dual ballast.
To replace the lamps touch it at the lamp socket.
StepProcedureReference
1
Remove the chromium-plated front
cover.
2Unscrew the next cover
(5 screws)
24
3Remove carefully the lamp
downwards
4If necessary the reflector may be
exchanged, too.
5Insert the new (reflector and) lamp
and mount the covers in reverse
mode.
Illustr. 5-15 Energy saving lamps in the canopy and its ballast
Operation and Service megaSun 5600
5.8 Filter mats
Cleaning intervalsThe cooling air is drawn in through two dust filters. Depending
on the installation site, clean the filter mats or, if necessary,
replace them after approx. every 100 hours of service. To ensure
a trouble-free service of the unit, exclusively use original spare
filter mats.
Take the opportunity to check the heat exchangers of the airconditioning unit as well to see if they are dirty. (Section 5.10).
Dirty heat exchangers considerably reduce the capacity of
the air-conditioning unit. Vacuum-clean the heat exchangers if
necessary.
Filter mat in the
canopy
Filter mat in the
base section
This filter mat can be easily replaced at the rear side of the
canopy.
Illustr. 5-16 Replacing the filter mat
The filter mat is located behind the decorative lighting in the
base section. Open the bed pane and remove the fluorescent
tube. Now you have free access to the filter mat.
Illustr. 5-17 Filter mat in the base section
25
Operation and Service megaSun 5600
5.9 Canopy drive
Regular
maintenance
In order to guarantee a trouble-free operation of the canopy
drive, check and service the spring ropes each time the tubes
are replaced. (see table step 1-2)
Tightening the
springs
If the canopy does no longer remain firmly in the upper position,
the two springs have to be re-tightened. For that purpose you
will need a ratchet spanner with a 10mm socket.
StepProcedureReference
1Check the ropes for wear. If individual wires of the rope
are spliced, always replace both ropes.
2Remove the lateral pane.see 5.2
3Both at the right-hand and at the left-hand side you will
have free access to the tension screws. When you have
Illustr. 5-18
Illustr. 5-19
an XXL-unit remove the cover plates.
4Tighten both springs in a balanced way.
5Check the canopy drive: the canopy remains firm in any
position.
6Close the lateral pane.
26
Illustr. 5-18 Left tension screw Illustr. 5-19 Right tension screw
Operation and Service megaSun 5600
5.10 Cooling system and exhaust air
Principle of the
cooling system
The following pictures illustrate the cooling system of the
sunbed.
Ambient air (if there is no air-conditioning) or cooled air mixed
with ambient air (if there is air-conditioning) (Illustr. 5-22 and
Illustr. 5-23) is blown by the body ventilator through ten nozzles
into the tanning room of the sunbed (blue).
Through the upper filter, the fan draws in air to cool the tubes
and burners in the upper part; through the front filter cooling air
is drawn in for the lower part (tubes). The exhaust air is then
blown off through the exhaust flue (green).
Illustr. 5-20 Body cooling (blue) and unit
cooling (green), filter mats (orange) and
exhaust air (red)
Illustr. 5-21 Exhaust fan (mounting
picture)
27
Operation and Service megaSun 5600
Illustr. 5-22 Cold air for the canopy
(mounting picture)
Illustr. 5-23 Ambient air mixed with cold air
for the canopy
28
Cooling the base
pane
Air nozzles
Filter
In apparatuses with an air-conditioning unit (optional), both
base pane and canopy are cooled.
Ambient air is drawn in through the filter, cooled in the airconditioning unit and led through an air hose to the space
between duct pane and base pane. At the foot of the bed, this
air is mixed with cabin air and blown through a fan into the
tanning space of the system (three nozzles).
Air conditioner,
blower and
air tube
Illustr. 5-24 Cooling principle of base section
Operation and Service megaSun 5600
Maintenance of
the exhaust air
system and the
air-conditioning
StepProcedureReference
A clean and trouble-free exhaust air system prevents the
apparatus from overheating. The maximum hose length of 6 m
must not be exceeded unless there is an additional ventilator.
1Open the lower front cover and check the following
items in regular intervals:
2The air hose of the air-conditioning unit must not have
any kinks.
3The filter mats in the base section and in the canopy
section must be clean.
see also
Section 5.10
see also
Section 5.7
4Check the exhaust air hose for kinks or damages,
and if there is an additional ventilator due to hose
overlength, check its function as well.
5An adequate ventilation and air extraction in the studio
must be guaranteed at any time.
6
Check the correct position of the duct pane to make
sure that the base pane is adequately cooled.
5.11 Air-conditioning unit
Air hose
Fan
Condensation
hose leads
outside to the
condensate tank
Condensate pump
ChecksCheck the heat exchangers of the air-conditioning unit for dirt
particles each time a tube is replaced. Dirty heat exchangers
reduce the performance of the air-conditioning unit.
Open the front cover and vacuum-clean the heat exchangers, if
necessary.
Check the connection hose each time the tubes are replaced. Defective hoses must be replaced.
29
Operation and Service megaSun 5600
5.12 Condensate pump
MaintenanceCheck the function of the condensation pump each time a tube
is replaced.
Open the front cover and slowly fill the tub of the air-conditioning
unit with water.
Make sure that the water is pumped off periodically. For this test,
the unit must be connected to the mains supply.
By a regular and proper maintenance of the apparatus, you make
a substantial contribution to the safety of the system and to a
long period of trouble-free operation.
The condensate tank has to be checked every day and to be
emptied if necessary.
Air condition
device
Condensat tube
30
Condensat pump
Tub
5.13 Changing aroma box / aquaCool canister*
aquaCoolIf the canister is empty - it will be displayed after the tanning
session or by a icon on display - the aquaCool function must be
switched off suddenly and the canister must be replaced by a
new one.
More about replacement see Section 8.4 .
aroma About replacement see Section 8.4 .
* this is only preset if the feature is ordered
Operation and Service megaSun 5600
5.14 Music system with MP3-player*
MP3 player
Below the base pane (head of the bed) you will find the
construction elements for
•MegaVoice, the audio user guidance,
•MP3-player for the options: Music and
•I²C-Audioswitch
Audioswitch is for the I²C-BUS-adaption, for the connection
of an external music signal with volume regulation and the
connections to the MP3-players.
The memory card for the MP3-player can be changed after
opening the base pane (see illustration on the following page).
Illustr. 5-26 Installation below the base
Illustr. 5-27 MP3 player with music card
pane
Illustr. 5-28 Construction elementsIllustr. 5-29 MP3 for megaVoice
* this is only preset if the feature is ordered
31
Operation and Service megaSun 5600
Abb. 5.31 I2C AudioswitchAbb. 5.30 MP3 for music (Option)
32
Abb. 5.32 Memory card;
Unlock: press it and then remove
the card.
5.15 Replacing the aquaCool nozzles
After 1000 hours of operation, the aquaCool nozzles have to be
replaced in order to ensure that aquaCool stays fully operative
and efficient. The installation instructions will be enclosed in
your spare parts consignment.
Abb. 5.33 New memory card:
insert and press until it is looked.
Operation and Service megaSun 5600
6. Technical data
6.1 Data which all apparatuses have in common
Ambient conditions
Installation sitein dry rooms with sufficient air supply and ventilation
Relative humidity≤70 %
Ambient temperature≤30°C
ATTENTION!The unit must not be operated if the coin/timer system or
the internal control system of the maximum tanning time
is defective or if a filter is broken or missing.
Condensate
Outletat the left-hand rear side of the unit
DisposalConnection to sewage system or tank (capacity ≥5l)
Quantity Depending on local conditions and air humidity
NoteFor the purpose of pumping the water off, the power
supply must not be disconnected after the tanning
session
Dimensions of megaSun 5600
Length x width x height2360 x 1260 x 1400 mm when closed
2360 x 1260 x 1800 mm when opened
Central exhaust air duct
Diameter
Height (top edge)
Exhaust air hoseØ 300 mm
Weight (with airconditioning unit)
Electrical connection
Connection box≥ (140mm x 120mm x 70 mm) with PG 21
Power supply400 V /3N/50Hz
FusesCircuit breaker 3 pins, 3 x 20 A (RCD) for megaSun 5600
Wires and diamoter5 x 4 mm2 Ölflex
Internal plug: 230 VFor PC, lamp etc., NOT for high loads.
300 mm
1600 mm
670 kg
Super
Circuit breaker 3-polig, 3 x 25 A (RCD) for
megaSun 5600 Super Power und megaSun 5600 Ultra
Power
33
Operation and Service megaSun 5600
6.2 Views
Ø300
1600
1260
Illustr. 6-1 Front view Illustr. 6-2 Lateral view
6.3 megaSun 5600 Super / Super CPI
34
Super Super CPI
Exhaust airappr. 2250m³/h (free blow) appr. 10 m/sec
Air velocity
Lamps4x 400 W / megaSun 600
Filter panesKBL 3020019100
Tubes, canopy and
lateral sections
UV3: 26x megaSun R 100 III
UV4: 26x megaSun Super R
100W
UV3: 26x megaSun R 100 III
UV4: 26x megaSun Ultra
Power R 100 Longlife
powered by CPI
Tubes, base section UV3: 18x megaSun R 100 III
UV4: 18x megaSun Super R
100W
UV3: 18x megaSun R 100 III
UV4: 18x megaSun Ultra
Power R 100 Longlife
powered by CPI
Shoulder tanners 2x 250 W / megaSun 250
Rated capacity W
w. air conditioner
w/o air-condition
8910
7650
10110
8850
Operation and Service megaSun 5600
6.4 megaSun 5600 Super Power / Super Power CPI
Super Power Super Power CPI
Exhaust air appr. 2250m³/h (free blow)
Air velocityappr. 10 m/sec
Lamps
Filter panesKBL 3020019100
Tubes, canopy and
lateral sections
UV3: 4x 400 W / megaSun 600
UV4: 4x 500 W / megaSun 600
UV3: 26x megaSun R 160W III
UV4: 26x megaSun Super R
160
UV3: 26x megaSun R 160W III
UV4: 26x megaSun Ultra Power
R 160 Longlife powered by CPI
UV4/legTanner: 26x megaSun
Ultra Power R 160 Longlife
powered by CPI
Tubes, base
section
Shoulder tanners2x 250 W / megaSun 250
Rated capacity W
w. air conditioner
w/o air conditioner
UV3: 18x megaSun R 100 III
UV4: 18x megaSun Super R
100W
10870
9610
UV3: 18x megaSun R 100 III
UV4: 18x megaSun Ultra Power
R 100 Longlife powered by CPI
6.5 megaSun 5600 Ultra Power / Ultra Power CPI
Ultra Power Ultra Power CPI
Exhaust airappr. 2250m³/h (free blow)
Air velocity appr. 10 m/sec
Lamps
Filter panesKBL 3020019100
Tubes, canopy and
lateral sections
Tubes, base section
Shoulder tanners2x 250 W / megaSun 250
UV3: 4x 400 W / megaSun 600
UV4: 4x 500 W / megaSun 600
UV3: 26x megaSun R 160W III
UV4: 26x megaSun Super
R 160
UV3: 18x megaSun R 160 III
UV4: 18x megaSun Super
R 160
UV3: 26x megaSun R 160W III
UV4: 26x megaSun Ultra
Power R 160 Longlife
powered by CPI
UV4/legTanner: 26x
megaSun Ultra Power R 160
Longlife powered by CPI
UV3: 18x megaSun R 160 III
UV4: 18x megaSun Ultra
Power R 160 Longlife
powered by CPI
12070
10810
35
Rated capacity W
w. air conditioner
w/o air-conditioner
11950
10960
13150
11890
Operation and Service megaSun 5600
7. Wiring diagram
7.1 Mains voltage
Fuses and residual
current-operated
circuit breaker (FI)
The unit has to be connected to the 400 V mains; the
connection is to be protected by fuses. For details on the fuses,
please refer to the section „Technical data“. An FI protective
switch is required in any case. KBL Solarien AG recommend the
following type: KBL 3200 0770 00.
Should any interference occur due to the operation of your tanning unit with the mains, e.g. with ripple-control systems (TRA),
consult your power-supply company regarding the installation of
corresponding blocking elements (audio frequency suppressor).
400V/3N/50
Branch box with fuses (see Technical
Date) and protective circuit breaker
type FI KBL 3200077000)
PE N L3 L2 L1
36
blaugnge
gngeblau
PE N L3 L2 L1
321
321
megaSun 5600*
Operation and Service megaSun 5600
7.2 megaVoice without music option
Music amplifier
3220 2885 00
Via an interface card, the MP3-player megaVoice is connected
to the music amplifier, which leads to the loudspeakers
(connected in parallel, equal-phased).
Musikverstärker
3220 2885 00
E8: 6 5 ... 2 1
7.3 Internal music signal MP3-player
MP3-player and megaVoice are connected to the Audio switch
which leads the music signal to the amplifier and then to the
loudspeakers (connected in parallel, equal-phased).
Interface-
karte
3220 3230 60
MP3
megaVoice
3220 3222 95
Musikverstärker
3220 2885 00
E8: 6 5 ... 2 1
I2C Audio-
switch
3220 3230 20
megaVoice
3220 3222 95
MP3 Musik
3220 3222 90
Audio switchMP3 MusicMP3 megaVoice
MP3
37
Operation and Service megaSun 5600
7.4 External music signal without channel selection
To connect the music signal use a 2-pole shielded cable, the
shield has to be earthed at the signal source. The cable is
connected to the marked clamps of the Audio switch. The
potentiometer is used to set the signal. The loudspeakers are
connected in parallel, equal-phased.
Music amplifier
3220 2885 00
E8: 6 5 ... 2 1
I2C Audio-
switch
3220 3230 20
shielded cable
Masse
ext. music
signal
7.5 External music signal (100V) without channel selection
100V-Music signal
Transformer
9100 0170 00
For this application you will need a transmitter, type
9100017000, and the music signal is connected to the clamps
“IN”.
MP3
megaVoice
3220 3222 95
38
Music amplifier
3220 2885 00
E8: 6 5 ... 2 1
Music signal
Operation and Service megaSun 5600
Transformer
OUT
IN
I2C Audio-
switch
3220 3230 20
MP3
megaVoice
3220 3222 95
7.6 External music signal with channel selection
To connect the music signal use a 2-pole shielded cable, the
shield has to be earthed at the signal source. The cable is
connected to the marked clamps of the Audio switch. The
potentiometer is used to set the signal. The loudspeakers are
connected in parallel, equal-phased.
Music amplifier
3220 2885 00
E8: 6 5 ... 2 1
I2C Audio-
switch
3220 3230 20
MP3
megaVoice
3220 3222 95
Channel
Processor
selection
3220 3110 00
shielded cablel
Masse
Music signal
Audio switch
100V-SignalIf the external music signal is a 100V-signal, the transmitter is
introduced into the signal path in front of the Audio switch. (see
7.4)
Operation and Service megaSun 5600
39
7.7 External Channel Selection
The following diagram shows the wiring of the channel selection
on the audio equipment’s side.
Wiring on the audio system of the studio
Puls Coding
Volume -
channel selection -
channel selection +
Control voltage
Volume +
PE12345
Wiring on the audio system of the studio
BCD Coding
channel selection
channel selection
Control voltage
40
PE12345
Operation and Service megaSun 5600
7.8 External Timer
TimerThe timer has to be connected as follows. The individual
specifications and wiring diagrams of the different types of
timers have to be observed. A door contact is necessary for the
option “cabin fragrance”.
Release signalDoor contoct
Timer
Wire No.
Cable
Ölflex 7 x 1 mm
Wire No.
L1N
2
gnge
6
gnge364512
43215
PENL1
Control
megaSunm 5600
41
Start
(5V/10mA ... 230V/2A)
Operation and Service megaSun 5600
8. Service
8.1 General information and structures
Service levelsThere are two service levels which are both accessible by
passwords. To get into these levels and to release processes the
touch keys 1 ... 0 have to be pressed. For that purpose, the plus
and minus keys bear numbers which in the illustration below are
slightly bigger than in reality.
In order to get access to the service pages, two prerequisites
have to be fulfilled:
• there must not be any error message on the display
• there must not be any incoming signal from the coin/
token box system
In case there is an error message you need to reset this
message by touching the “Stop” sensor field.
12345
42
67890
Illustr. 8-1 Touch keys 1 ... 0 for service operations
Service level IIn order to get access to level I, first enter the sequence 1 6 1
and then PIN 1 1 1 1.
Service level IIThis level comprises service pages that may be used by
Technical Service staff only.
Starting from level I, menu „PIN II“, you will get into level II by
entering the correct PIN (not 1 1 1 1!)
General navigationWhen having called up service level I, the following keys can be
used as follows:
Key 5 to move forward in the menu
Key 0 to move backwards in the menu
Stop key to leave service level or menu
Start key to select a menu item or to save the value displayed
Operation and Service megaSun 5600
8.2 Service level I
8.2.1 Structure of the menu on service level I
Operation-InfoWorking hpurs
Tube hours
CPIModus Ö/P/ SP
CPI RESET
TimerMonday MO
Tuesday TU
...
Sunday SU
Time/DateTime
Date
PIN II
AACAroma
Enter the
correct PIN
Timer A on
Timer A off
Timer B on
Timer B off
Service level II
Solar. ON/ OFF
Booth ON/OFF
B. Inter 00/h
Gate ON/OFF
B.Timer
Aqua
Cycle
Color
AR. Cont 99%
ON/OFF
AQ. Time
43
R G B
Operation and Service megaSun 5600
AudioExtern
ON/OFF
Volume
Nonstop
OverviewOn this level you will find the following menus:
Selection of menus by
pressing keys 5 and 0
84% (± 2%)
ON/OFF
44
8.2.2 The menus on service level I
Operation-InfoIn this menu, the service hours of the sunbed (WORK) and the
burning time of the tubes (TUBE) are displayed.
DisplaySelection
5
0
With the START key you open the sub menus.
With the STOP key you go back one level higher.
If you have changed a value and you will safe it press START.
Operation and Service megaSun 5600
CPI*In this menu, the service hours of the sunbed (WORK) and the
burning time of the tubes (TUBE) are displayed.
Enter the CPI ModeSelectionConfirmation
4
9
CPI ResetSelectionConfirmation
0
51
Timer
This function allows you to specify two times for switching on
and two times for switching off the decorative lighting for any
day of the week.
If you do not need the switching time you can delete it by
pressing key 1. The hours are set using keys 2 – 4 and the
minutes with the help of the keys 3 – 8
Weekday: Monday to SundaySelectionConfirm.
0
. . . .
5
Time A/BON and A/BOFHours / MinSafe
2 3
4 8
* this is only preset if the feature is ordered
Operation and Service megaSun 5600
45
Time / DateThis menu shows time and date. Both values can be changed.
Display DateSelection
5
0
Change the timeSelectionSafe
Std Min
1 3
6 8
Change the dateDaySafe
1
6
The day of the week
appears automatically
46
AACThis menu has four sub-menus: :
•AROMA
•AQUA
•COLOR
•CYCLE
which can be selected – as in all the other menus – by pressing
the keys „0“ and „5“
AromaThis is a sub menu of AAC and it has also 6 sub-menus:
•SOLAR. ON / OFF: A fragrance is or is not sprayed off on
the sunbed.
•BOOTH ON / OFF: A fragrance is or is not sprayed off in
the booth.
•B. INTER. xx/h: Selection of the cycles per hour, when
the fragrance is sprayed off. It can be adjusted to times
between 00/h and 24/h
•GATE ON / OFF: A fragrance is sprayed off in the booth
when the door is opened or closed.
•B: TIMER: A fragrance can be sprayed off at particular
times on the days of the week. There is one interval
Operation and Service megaSun 5600
available for each day (for the setting see „Timer“).
•AR. CONT: Shows the filling level of the aroma gel. When
it has reached 00 %, this status is also shown after the
tanning session. When having replaced the tin with the
aroma gel this message has to be acknowledged (see 8.3
and 8.4) by pressing touch key 1.
These sub-menus can be selected – as in all the other menus
– by pressing the keys „0“ and „5“. The function is switched on
by the key “+” or off by “-”, in the same manner increased or
decreased.
SelectionConfirm.
0
AquaThis is a sub menu of AAC.
Water is „misted up” by means of nozzles making the tanning
session more refreshing.
•AQUA ON / OFF: This function can be switched on by
pressing the „+“ key (4) above „OFF“, and switched off by
pressing the „ - “ key (8) below „ON“.
•AQ.TIME: The spraying cycle is set in the menu CYCLE
and the spraying duration in this menu AQ.TIME between
2 ... 6 seconds. The details are set by pressing the „+“
and „-“ keys above or under the time display.
5
47
Operation and Service megaSun 5600
ColorIt is a sub-menu of AAC.
The colour of the colour-stimulation can be pre-selected. If you
press the „+“ key above one of the letters (e.g. G), this letter
(here G) will stop flashing and this colour (Green) has been
selected.
When all „-“ keys have been pressed, all the letters will flash, i.e.
the colour-stimulation has been inactivated.
It is only possible to choose one colour by pressing the
corresponding „+“ key.
Selectionon / off
04 / 9
5Adjust
4 / 9
48
SelectionConfirm.
+ / -
CycleIt is a sub-menu of AAC.
The duration of the breaks of aroma and aqua can be set
between 1... 5 minutes.
The details are set by pressing the „+“- and „-“ keys above or
below the time.
AdjustConfirm.
+ / -
Operation and Service megaSun 5600
Audio*This menu has five sub-menus:
•EXTERN: If the signal is ON, an external source sends
the music signal, otherwise the internal MP3-player is
used.
•VOL. HOT: the volume of the music or of the user
guidance system when the fan is running
•VOL. COOL: the volume of the music or of the user
guidance system when the fan is not running.
•NONSTOP: when the signal is ON, the music signal is
permanently amplified, otherwise the music transmission
ends with the tanning cycle.
•CH: The channel selection may be changed from channel
and volume selection to BCD selection of a music source.
It is possible to select up to 4 music sources. (The volume is adjusted at the music amplifier).
The menu can be selected by pressing the „0“ and „5“ keys,
the functions can be activated or inactivated by pressing the „+“
key above OFF or the „-„ key below ON, or you can increase or
decrease the values by pressing +/- above the numerical value.
* this is only preset if the feature is ordered
on / offConrm.
+ / -
Adjust
+ / -
Adjust
+ / -
in 2-%-
Steps
in 2-%-
Steps
on / off+ / -
5 SelectConrm.
0
49
Operation and Service megaSun 5600
8.3 Service level II
8.3.1 Structure of the menus in service level II
Configuration
C M A B
Configuration
ACS
Aircon.
OFFSET
A.Start
Adjust of the
tube hours
Time stamp
1st download
Time stamp
last download
Conguration
Aroma / Aqua
Test
Release
Zero or
start-value
Display
Time
Display
Date
Aroma
aquaCool
aquaExtra
Software release
UV-type, device
50
Operation and Service megaSun 5600
8.3.2 Menus of service level II
Conguration
menus
ACS
In this menu functions can be activated or inactivated. This
makes sense when the corresponding function is missing or
temporarily not available (faded out).
C Channel / Music channel
M Music / Volume
A Air-conditioning
B Facial tanner
The setting can be changed by pressing the “+” or “-“ key above
or below the symbol. If the two dots behind the letter are at the
bottom, the respective function is inactivated.
C: no channel selection possible,
B: facial tanner can be operated
This menu has three sub-menus: “Aircon.“, “OFFSET“ and
“A.START“.
•
Aircon. Presetting for the air-conditioning unit in tanning
mode.
•
ON: The air-conditioning unit starts automatically as
soon as the tanning session is started.
•
OFF: The air-conditioning unit starts operating only if
it is activated by the studio guest.
•
OFFSET: Only applicable for tanning units equipped with
ACS.
NOTE: Contact your KBL Technical Service before making
any changes within this menu item.
Increasing the offset value results in the fan starting at a
higher speed. The offset value may have to be adjusted, e.g.
in case of the thermal switch of the sunbed being triggered
due to bad exhaust vent conditions in the tanning studio. The
offset value may only be increased after any other causes for
the triggering of the thermal switch have been excluded (see
section “Fault messages/exhaust air”).
00-99%: The offset value can be increased in steps of 10%.
A.START: Presets the fan-power level at the beginning of
•
the tanning session. Adjustable from 20 to 99%. During the
tanning session, the studio guest can change the fan power
or switch off the fan.
51
Operation and Service megaSun 5600
AR/AQ*
The aroma function can be activated (AR:) or inactivated (AR:),
the same goes for the aquaCool function (AQ: / AQ: ).
The setting can be modied by pressing the „+“ or „-’’ key above
or below the symbol.
Any modications are accepted by pressing the START key.
Tube hoursIn this menu, you can set the service hours of the tubes in steps
of 5 hours. This display has to be reset to zero after each tube
replacement.
Attention! Always carry out a reset after each tube replacement
Enter the hourschangesafe
1
6
52
Time stampsHere you can store the time stamps of the rst and last download
of the software.
Selection
5
First Download
0
5
Last Download
0
* this is only preset if the feature is ordered
Operation and Service megaSun 5600
Test*You can also test the three functions Aroma, aquaCool and
aquaExtra without a tanning program.
After selecting a function, press key 1 to start the test.
* this is only preset if the
feature is ordered
aquaExtra is switched on by the key 4 and off by the key 9. The
cycle time is 5 min. It is use to check the quality of aquaCool.
SelectionOn
5 1
0 4
9
VersionThe version of loaded software is displayed since vers. 4.8.
This is analogue to the display after the rst start. The version
depends on the sunbed: without easyCare (here 5.3) or with
easycare (here 1.8).
1
Sub-type of the sun bed
UV-type
Sun bed0
Selection
5
53
Operation and Service megaSun 5600
8.4 Refilling / Changing Aroma and aquaCool*
Gel: SUNRISE and
DAYDREAMS /
aquaCool
StepProcedureReference
1Open the lower front cover and regularly
check the lling level of the water tank and
of the aroma tin. When the content of
one of the container has been used up,
replace the corresponding container.
2Pull the holding element of water tank and
aroma tin forward. .
3Move the covering handle on the lid of the
aroma tin to the left (1) and then move the
lid upward (2). Now you can replace the
tin.
The gel tin and the water tank are in the base part between the
air-conditioning unit (on the left) and the electronics system (on
the right).
2
1
54
4Unscrew the lid with the hoses from the
tank and replace the empty tank by a full
one. Screw the lid on again.
Keep clean the end of the tubes when
changing the tank (use a plastic bag).
Only use the specic water by KBL
„aquacool“. Otherwise the nozzles may
clog up which might produce infections.
5Put the constructional elements back into
their original place in the sunbed.
6Acknowledge the error message in
service level I by calling up the displays
shown on the right and by pressing key 1.
The pipes are marked with colour points:
Blue compressed air for aquaCool
Red reflux aquaCool
Green flow pipe aquaCool
Yellow aroma
Abb. 8-5 Canopy undersideAbb. 8-6 Canopy upper side
Abb. 8-7 Ionizor and aroma pipesAbb. 8-8 Pipes at the nozzles
Operation and Service megaSun 5600
55
8.6 Error message
Error message
“Abluft“ oder
“Windschalter“
This error message is displayed on the operating panel and
can be acknowledged by pressing the “Stop“ key. Prior to this,
service staff has to nd the reasons of these error messages.
Possible reasons can be:
• temperature in the unit is too high
• exhaust vent system is defectiv
Error message
“Ende der
Besonnung“
„End of tanning
session“
BUS-ErrorDaten line of the Bus I²C-Bus is disturbed
This message will be displayed after 40 minutes of uninterrupted
operation of the tanning system.
By turning off the coin-operated system this message is
acknowledged.
— 230 V is missing at MP3-Player or Audio Switch
— Bus connector at MP3-Player in wrong position
E01BUS:ABLThere is not any data link between the controller board and the
revolution control...
Reason: defective or not connected I²C revolution control.
56
E02:BUS:TMPReason: defective or not connected I²C temperature sensor.
Solution: press the START key. The blower is running with max.
revolution during the temperature controll.
E04:BUS:VOICReason: There is not any data link between the controller board
and the MP3 player Voice.
Solution: press the START key. The controller is working as one
w/o megaVoice.
Reason:
— missing soldering bridge on MP3-Player megaVoice,
— SD card not readable
— formating or wrong inserted,
— Plug at MP3 iInterface or at I²C Audio switch is inserted uncorrect.
E05BUS:RELConguration error: I²C-Relay board (8) an I²C Relais board (2) at
the same time connected.
Operation and Service megaSun 5600
9. Tanning instructions
9.1 General tanning instructions
1Different skin types react differently to sun and tanning times. Follow the
skin type table and the individual tanning program (see p. 56 ff.).
Once you have reached your nal tanning result, further tanning can only
be achieved by considerably exceeding the recommended tanning times.
This has to be avoided at all costs!!
2UV radiation from the sun or from UV apparatuses may cause damages
to skin or eyes. These biological effects depend upon the quality and
quantity of the radiation as well as on the skin and eye sensitivity of the
individual customer.
3Sunburn can be a reaction of the skin after excessive radiation.
Excessively repeated exposures to UV radiation from the sun or from UV
apparatuses may lead to premature ageing of the skin and increase the
risk of getting skin cancer.
4Unprotected eyes may become inflamed on their surface or in some
cases, e.g. after a cataract operation, the retina can be damaged after
an excessive UV exposure. Cataracts may develop after many repeated
exposures.
5Special care is necessary in cases of pronounced individual sensitivity
to UV radiation and in cases where certain medicines or cosmetics are
applied.
6It cannot be said in any case that the use of a sunbed reduces the risk of
getting sunburn.
7The apparatus must not be operated when the timer or the lter panes are
defective.
8The following safety precautions have to be taken: Safety precautions
•Always use the goggles provided.
•Remove any cosmetics before the tanning session and do not
use any sunscreens.
•Refrain from tanning when taking medicine which increases the
sensitivity to ultra-violet radiation. If in doubt, ask your doctor for
advice.
•Allow a period of at least 48 hours between the rst two tanning
sessions; do not sunbathe and use the apparatus on the same
day.
•Follow the recommendations concerning tanning times and
tanning intervals (see 56 ff).
•See a doctor when your skin produces persistent swellings or
sore points, or when pigmented moles change their appearance.
57
Operation and Service megaSun 5600
9The following groups of people are not allowed to use the apparatus:
•children
•people with pace-makers
•people who get sunburn without tanning when exposing
themselves to the sun
•people suffering from sunburn
•people who suffer or have suffered from skin cancer or who are
predisposed towards it
10Tanning apparatuses of UV-Type 4:
Attention – To be used only after prior consultation of a doctor.
9.2 Super, UV-Type 3, inductive
Tanning session Skin type IISkin type IIISkin type IV