!Warning! For your safety please read the following warning notices and instructions.
Safety, Approvals and Regulatory Domain
Information
Safety Instruction
For your protection, please read and observe all safety instructions before operating this
system and keep this sheet and any additional instructions for future reference.
Installation and Use
OBSERVE WARNINGS: All warnings in the operating instructions should be carefully
followed. Do not make any modifications to the WESII unit, Power Injection Module
(PIM), or any other KBC Networks electronic device, as the unit(s) will no longer comply
with legal regulations and therefore void its warranty.
WATER AND MOISTURE: The WESII unit is weatherproof provided it is installed in
accordance to the mounting details listed in section 2.4.3. However, further protection
or housing is suggested for harsh environments, as moisture damage voids its warranty.
The PIMs used in this system are NOT weatherproof. None of the modules in this system
are waterproof and should never be submerged. Severe electrical shock, personal injury
or damage to the equipment may result.
POWER SOURCE: Connect the equipment to a power source only of the type described
on the operating instructions or as marked on the equipment. Excessive or insufficient
current or voltage can cause extended trouble-shooting or even damage that could
negate its warranty. The power supply cable should not be modified/extended due to the
ability to use up to 100m of power over Ethernet cable. In addition, Ethernet cable
running from the PIM to the WEM should be kept separated from high-voltage cables
and/or transformers.
ATTACHMENTS: Use only KBC Networks’ supplied or recommended Power Injection
Modules, Power Supplies, Cat5 Cables and weather seals and plugs.
WHEN NOT IN USE: Unplug the power if the equipment is left unattended or unused
for long periods of time or during lightning storms.
REPLACEMENT PARTS: When replacement parts are required, use only replacement
parts specified by KBC Networks. Unauthorized substitutions may result in damage to
the system and could void the warranty.
Radio Frequency Interference Statement for Class B Digital Devices
This equipment has been tested and found to comply with the limits for an intentional
radiator, pursuant to Part 15, subpart C of the FCC Rules. This equipment generates,
uses and can radiate radio frequency energy. This equipment generates, uses, and can
radiate radio frequency energy. If not installed and used in accordance with the
instructions, it may cause harmful interference to radio communications. The limits are
designed to provide reasonable protection against such interference in residential
situations. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause interference to radio or television reception,
which can be determined by turning the equipment on and off, the user is encouraged to
try to correct the interference but on or more of the following measures:
• Re-orientate or relocate the receiving antenna of th
• Increase the separation between the equipment and the affected receiver.
• Connect the equipment and the affected receiver to power outlets on separate
circuits.
• Consult the dealer or an experienced radio/TV technician for assistance.
Shielded cables must be used with this unit to ensure compliance with Class B FCC
limits. Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
Changes or modifications not expressly approved by KBC could void the user’s authority
to operate the equipment.
FCC Power Output Restrictions
The FCC does not require licensing to implement this device. License-free operation in
the industrial, scientific and medical band is documented in FCC Rules Part 15.247. It is
the responsibility of the individuals designing and implementing the radio system to
ensure compliance with any pertinent FCC Rules and Regulations. This device must be
professionally installed.
Exposure to Radio Frequency Fields
The WESII is designed to operate on the 5 GHz frequency band with up to 50 Watts EIRP
maximum transmit power. This level of RF energy is above the Maximum Permissible
Exposure (MPE) levels specified in FCC OET65:97-01. The following precautions must be
taken during installation of this equipment:
• The installed antenna must not be located in a manner that allows exposure of
the general population to the direct beam path of the antenna at a distance less
than 20cm. Installation on towers, masts, or rooftops not accessible to the
general population is recommended or alternatively mount the antenna in a
manner that prevents any personnel from entering the area within 20cm from the
front of the antenna.
• It is recommended that the installer place radio frequency hazard warnings signs
on the barrier that prevents access to the antenna.
• During installation and alignment of the antenna, do not stand in front of the
antenna assembly.
• During installation and alignment of the antenna, do
These simple precautions must be taken to prevent general population and installation
personnel from exposure to RF energy in excess of specified MPE levels.
Industry Canada Restrictions
IC ID# 7849A-N523ESD
This Class A digital apparatus complies with Canadian ICES-003. To reduce potential
radio interference to other users, the antenna type and its gain should be so chosen that
the equivalent isotropically radiated power (E.I.R.P.) is not more than that permitted for
successful communication. This device complies with Industry Canada license-exempt
RSS standard(s).
Operation is subject to the following two conditions:
This device may not cause interference, and
This device must accept any interference, including interference that may cause
undesired operation of the device.
Cet appareil numérique de la classe A est confrome à la norme NMB-003 Canada. Pour
réduire le risque d’interférence aux autres utilisateurs, le type d’antenne et son gain
doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne
dépasse pas ce qui est nécessaire
pour une communication réussie. Cet appareil est conforme à la norme RSS Industrie
Canada exempts de licence norme(s). Son fonctionnement est soumis aux deux
conditions suivantes:
17 Compliance
Cet appareil ne peut pas provoquer d’interférences et
Cet appareil doit accepter toute interférence, y compris les interférences qui peuvent
causer un mauvais fonctionnement du dispositif.
RF Exposure Warning
The antennas used for this transmitter must be installed to provide a separation distance
of at least 37.2 cm from all persons and must not be located or operating in conjunction
with any other antenna or transmitter.
Les antennes utilisées pour ce transmetteur doivent être installé en considérant une
distance de séparation de toute personnes d'au moins 37.2 cm et ne doivent pas être
localisé ou utilisé en conflit avec tout autre antenne ou transmetteur.
This is a Class B product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Declaration of Conformity:
KBC declares the following:
Product Name: WESII
Model No.: 802.11n Station conforms to the following Product Standards:
This device complies with the Electromagnetic Compatibility Directive (89/336/EEC)
issued by the Commission of the European Community. Compliance with this directive
implies conformity to the following European Norms (in brackets are the equivalent
international standards.)
Electromagnetic Interference (Conduction and Radiation): EN 55022 (CISPR 22)
Electromagnetic Immunity: EN 55024 (IEC61000-4-2, 3, 4, 5, 6, 8, 11)
Low Voltage Directive: EN 60 950: 1992+A1: 1993+A2: 1993+A3: 1995+A4:
1996+A11: 1997.
CE Mark: following the provisions of the EC directive.
KBC also declares that:
The wireless card in this product complies with the R&TTE Directive (1999/5/EC) issued
by the Commission of the European Community. Compliance with this directive implies
conformity to the following:
EMC Standards: CE: EN 300 328-2, EN 300 826 (EN 301 489-17) EN 301 893.
CE marking on this product represents the product is in compliance with all directives
that are applicable to it.
This equipment may be operated in the following countries:
Great Britain and Northern Ireland, Austria, Belgium, Denmark, Finland, France,
Germany, Ireland, Italy, Netherlands, Norway, Portugal, Romania, Switzerland, Sweden
Installer Compliance Responsibility
Devices must be professionally installed and it is the professional installer's responsibility
to make sure the device is operated within local country regulatory requirements.
Dynamic Frequency Selection (DFS) & Transmit Power Control (TPC):
DFS and TPC are requirements of the ETSI standard EN301 893 V1.5.1, the European
Union’s harmonized radio standard for unlicensed devices operating in the 5150 – 5350
MHz and 5470 – 5725 MHz frequency bands. Radar detection is required when operating
on channels whose nominal bandwidth falls partly or completely within the frequency
ranges 5250 MHz to 5350 MHz or 5470 MHz to 5725 MHz. In addition devices using the
5600 – 5650 MHz band are subject to a 10 minute Channel Availability Check (CAC).
The following table shows how this can affect connection times for certain frequencies:
5MHz 10MHz 20MHz 20/40MHz
2 mins 2 mins 2 mins 2 mins
2 mins
2 mins 2 mins
2 mins
2 mins 2 mins 2 mins
2 mins
2 mins 2 mins
2 mins
2 mins 2 mins 2 mins 2 mins
2 mins
2 mins 2 mins
2 mins
2 mins 2 mins 2 mins
2 mins
2 mins 2 mins
2 mins
2 mins 2 mins 2 mins 10 mins
2 mins
2 mins 2 mins
2 mins
10 mins 10 mins 10 mins
10 mins
10 mins 10 mins
10 mins
10 mins 10 mins 10 mins 10 mins
10 mins
10 mins 10 mins
10 mins
10 mins 10 mins 10 mins
10 mins
10 mins 10 mins
2 mins
2 mins 2 mins 2 mins 2 mins
2 mins
2 mins 2 mins
2 mins
2 mins 2 mins 2 mins
2 mins
2 mins 2 mins
2 mins
2 mins 2 mins
2 mins
WESII User Manual
Environmental Restrictions of Wireless Devices
KBC products are engineered to the highest standards and designed to work in a variety
of wireless applications and environments. A wireless environment includes the site in
which the product is installed, the installation including power and cabling as well as any
extra materials that might be necessary to complete the wireless project. Due to the fact
that environments and installations differ from site to site, KBC cannot control the
variables required to ensure an ideal environment. Therefore, it is not possible to
guarantee a successful application based on a drawing, application note, distance
calculation, quote or other type of material that KBC may provide. Should a quote,
drawing, etc. be made available, it is based on the performance of the WESII product in
an ideal environment with clear line-of-sight, absence of 5 GHz interference and/or
frequency multi-path reflection. Therefore, KBC cannot be held responsible should the
products not operate as desired or should additional products be required to complete a
project. In addition, should a particular environment restrict the usage of the WESII in
any way, KBC offers a thirty (30) day return policy from date of shipment to the original
purchaser if goods are returned in an ‘as new’ condition.
European Directive 2002/96/EC requires that the equipment bearing this symbol on the
product and/or its packaging must not be disposed of with unsorted municipal waste.
The symbol indicates that this product should be disposed of separately from regular
household waste streams. It is your responsibility to dispose of this and other electric
and electronic equipment via designated collection facilities appointed by the
government or local authorities. Correct disposal and recycling will help prevent potential
negative consequences to the environment and human health. For more detailed
information about the disposal of your old equipment, please contact your local
authorities, waste disposal service, or the shop where you purchased the product.
Instruction of Disassembly
Note: disassembling or opening of the WESII unit voids warranty.
Instruction of Disassembly of KBC Product (For EU Directive 2002/95/EECWEEE)
Remove Serial Label adhesive
Remove cover screws attaching top cover to radio module cavity.
Remove tightening screws for printed circuit board (PCB).
Take out all PCBs.
Note: W
hen a product reaches the end of its life – return to KBC.
You may have received from KBC Networks products that contained – in part – free
software (software licensed in a way that ensures your freedom to run, copy, distribute,
study, change and improve the software). Such products include the WESII Series of
products.
As part of these products, KBC Networks may have distributed to you hardware and/or
software that contained a version of free software programs developed by the Free
Software Foundation, a separate not-for-profit organization without any affiliation to KBC
Networks. See http://www.gnu.org/philosophy/free-sw.html for more details. If KBC
Networks distributed any portions of these free software programs to you, you were
granted a license to that software under the terms of either the GNU General Public
License or GNU Lesser General Public License (“License”, copies of which are available
from http://www.gnu.org/licenses/licenses.html). The Licenses allow you to freely copy,
modify and redistribute that software without any other statement or documentation
from us.
For at least one (1) year from the date of distribution of the applicable product or
software, KBC Networks will provide to anyone who contacts us at the contact
information provided below, for a charge of no more than our cost of physically
performing source code distribution, a complete machine-readable copy of the complete
corresponding source code for the free software programs used in the version of the
programs that we distribute to you. The cost will be free if the delivery medium of the
machine-readable copy is through the Internet.
Contact information:
Email: techsupport@kbcnetworks.com
Tel: 949.297.4930
Address: 25691 Atlantic Ocean Drive Lake Forest, CA 92630
We do ask for your understanding regarding expected delivery timelines:
We will reply within 7 working days once the request has been made through
email/telephone.
The default version sent will be the latest that we used in the firmware/programs.
Note: i
exceed 2 weeks.
t may take longer if an older version is requested. The waiting time will not
This manual covers all the functions of the products that form KBC Networks’ WESII
Series. The WESII Wireless Ethernet System is a wireless transmission system that
provides a cable less transmission path for an Ethernet channel. They are designed for
use in a wide range of operating temperatures in non-environmentally conditioned,
outdoor applications. The primary function of the system is to replace Ethernet cables
where it is not practical or cost-effective or where it is beyond distance limitations.
WESII has been specifically designed to transmit constant streaming video but can also
be used to send and receive standard Ethernet data packets or to operate as a WiFi
Access Point. The units can be configured as a long range point-to-point wireless bridge
or as a point-to-multipoint receiving antenna communicating to numerous transmitting
Client/Station devices. This manual covers all operations and functions of the point-topoint and point-to-multipoint systems.
1.1.1.
The KBC WESII Series is a wireless transmission system that operates in the license free
2.4GHz & 5GHz bands and also in the 4.9GHz Public Safety band (only available in the
US). The units are available as PoE or non-PoE with a range of antennas to suit
applications. The units will support throughput of up to 99Mbps due to MIMO technology.
Data throughput2
(max values – limited by 10/100 port)
HT5 HT20 HT40
17Mbps 99Mbps 99Mbps
Latency < 10 mS
Power
Power input (supplied by PIM)
24Vdc, 500mA
Reverse voltage protected
Power method (non-PoE WESII) Passive PoE
Power method (PoE WESII) IEEE 802.3af (PD)
PoE cable spec 100m on 24AWG Cat5/5e/6/6e
Mechanical
Casing IP66
Dimensions (Patch L x W x D)
Weight
245mm x 245mm x 76mm
9.625” x 9.625” x 3”
420g
15oz
Installation Wall-mount or pole-mount
Environmental
Operating Temperature -40° ~ +74°C / -40° ~ +165°F
Storage Temperature -40° ~ +90°C / -40° ~ +194°F
Operating Humidity 5% to 95% non-condensing
Connectors
10/100 Electrical 1 x RJ45
Approvals
FCC Part 15 subpart C Class B
IC ID# 7849A-N523ESD
CE Class B
EN 55024 (IEC61000-4-2,3,4,5,6,8,11) Electromagnetic Immunity
EN 55022 (CISPR 22)
EN 60 950: 1992+A1; 1993+A2;
1995+A4; 1996+A1; 1997
Electromagnetic Interference (Conduction
and Radiation)
Low Voltage Directive
EN 300 328-2
EN 300 826
EN 301 489-17
EN 301 893
R&TT Directive (1999/5/EC)
2
Assumes an ideal environment with maximum signal rates & within receive
The WESII units are available with the following antennas:
• 2dBi/5dBi dual rated omni-directional antenna for 2.4GHz/4.9GHz & 5GHz
operation
• 9dBi integral patch antenna for 4.9GHz & 5GHz operation
• 11dBi integral patch antenna for 2.4GHz operation
• 17dBi integral patch antenna 4.9GHz 5GHz operation
• 9dBi external patch antenna for 4.9GHz & 5GHz operation
• 11dBi external patch antenna for 2.4GHz operation
• 17dBi external patch antenna for 4.9GHz & 5GHz opera
3.1 Omni-directional options
3.1.1 2dBi/5dBi
This is a dual frequency rated omni-directional antenna for 2.4GHz,
4.9GHz & 5GHz operation. At 2.4GHz the antenna has a gain of
2dBi and at 4.9GHz & 5GHz the antenna has a gain of 5dBi. The
beamwidth of the antenna is 360°.
tion
3.2 Integrated directional patch antenna
options
3.2.1 9dBi
This is an integral directional patch antenna option for 4.9GHz & 5GHz operation. The
antenna is dual polarized. The beamwidth is:
External antennas can be attached to the antenna ports on the external antenna chassis
and are provided with 2 x 1m cables. See section 6.1.2.
3.3.1 9dBi
This is an external directional patch antenna option for 4.9GHz & 5GHz operation, part
number PAT5M-9. The antenna is supplied as a separate unit that contains 1 x 9dBi
patch antenna and 2 x 1m cables. The antenna is dual polarized. The
beamwidth is:
This is an external directional patch antenna option for 2.4GHz operation,
part number PAT2M. The antenna is supplied as a separate unit that contains
1 x 11dBi patch antenna and 2 x 1m cables. The antenna is dual polarized.
The beamwidth is:
This is an external directional patch antenna option for 4.9GHz & 5GHz operation, part
number PAT5M. The antenna is supplied as a separate unit that contains 1 x 17dBi patch
antenna and 2 x 1m cables. The antenna is dual polarized. The beamwidth is:
• Replace flat washer, locking washer and hex nut.
• Remove ‘U’ shaped bolt.
• Bolt the unit to the pole.
• Up/Down Alignment offers one position when using the pre-fabricated channel
lock grooves on the swivel brackets. Directional antennas may require additional
up/down alignment angles than those allowed on the pre-fabricated grooves. To
achieve different angles, remove the 50mm Hex bolt. Insert the longer bolt and
add the star washer. Re-connect and tighten.
• Position the WESII unit to face the WESII unit at the other end of the link.
• Carry out the alignment process – see Section 10.4 for instructions and Section 7
WESII units are available as either PoE or non-PoE units.
6.2.1 Power Injector Module for the non-PoE WESII
Non-PoE WESII units are supplied with a mid-span Power Injector Module (PIM) and a
standard 24Vdc, 500mA Power Supply Unit.
Note: The Power Injector Modules are not weatherproof units and must be protected
from moisture.
Power – Power supply input
OUT – Connect to the WESII unit
IN – Connect to the Ethernet device
For extreme temperature conditions there is also a KBC Networks Industrial DIN Rail
power supply available, part number MDR-20-24. These units provide 24W at 24Vdc.
These units need to be purchased separately, for further details please contact KBC
Networks.
Note: K
powered using the supplied KBC Networks’ Power Injection Module.
BC Networks’ WESII non-PoE units are mid-span compliant and must be
WESII User Manual
6.2.2 Power for the PoE WESII
The PoE WESII units are IEEE 802.3af Powered Devices (PD) ie. they are powered from a
Power Sourcing Equipment (PSE) such as an Ethernet switch which provides power on
the Ethernet cable. There are a number of different Ethernet switches options with PoE
available from KBC Networks, these can be purchased separately. Please contact KBC
Networks for further information.
1 Status/Signal Strength Indicator – 40 RSSI
2 Signal Strength Indicator – 30 RSSI
3 Signal Strength Indicator – 20 RSSI
4 Signal Strength Indicator – 10 RSSI
5 Ethernet Link Activity
6 Power
7.1.1 LED Boot Up Process
• Upon connection of an Ethernet cable from the PIM to the unit, the Power LED 6
will light.
• After 1 second RSSI LEDs 1, 2 & 3 illuminate.
• RSSI LEDs 1, 2 & 3 then go off.
• After 5 seconds the Ethernet Link Activity LED 5, illuminates.
• At the same time the Signal Strength Indicator, LED 1 flashes for approximately 2
seconds.
• LEDs 1 & 5 then switch off.
• LED 5 comes on again and flashes intermittently showing that a connection is
established.
• After approximately 1 – 2 minutes RSSI LEDs 1, 2, 3 & 4 will light depending on
the level of signal strength.
1 2 3 4 5 6
7.2 PoE WESII
1 Signal Strength Indicator – 40 RSSI
2 Signal Strength Indicator – 30 RSSI
3 Signal Strength Indicator – 20 RSSI
4 Signal Strength Indicator – 10 RSSI
5 Not used
6 Ethernet Link Activity
7 Power
7.2.1 LED Boot Up Process
• Upon connection of an Ethernet cable from the PSE to the unit, the Power LED 7
will light.
• After 1 second RSSI LEDs 1, 2 & 3 illuminate.
• RSSI LEDs 1, 2 & 3 then go off.
• After 5 seconds the Ethernet Link Activity LED 6, illuminates.
• At the same time the Signal Strength Indicator, LED 1 flashes for approximately 2
seconds.
• LEDs 1 & 6 then switch off.
• LED 6 comes on again and flashes intermittently showing that a connection is
established.
• After approximately 1 – 2 minutes RSSI LEDs 1, 2, 3 & 4 will light depending on
1. Thread the Cat 5 cable through the hole in the gland.
2. Pull the cable through and crimp on the RJ45 connector – see section 8.2
3. Connect the RJ45 connector into the WESII’s LAN port.
4. Tighten the clamping nut until the Ethernet cable is secured in the connector until it
is hand tight.
Note: the RJ45 connector does move slightly within the LAN port on the WESII unit this
allows the RJ45 connector to be connected to the Ethernet port more easily.
8.2 Configuring the Cable.
Note: The total length of cable from the WESII to the Ethernet device cannot exceed
100m (325 feet); however, for a non-PoE WESII unit the PIM can be located anywhere
along the overall 100m of cable. KBC Networks recommends shielded Ethernet cables for
the cable connecting the PIM to the WESII unit. Any cable exposed to the elements
should also be outdoor rated.
1. Determine the length of cable that will be required and where the PIM will be
located.
2. Slide the weatherproof connector over the cable jacket before crimping the
connector. See Section 8.1 for the assembly instructions. If needed, see below for
color-code standards to configure the correct type of Ethernet cable.
Note: E
to one of the Ethernet standards (568-A or 568-B) in order for the WESII system to
operate efficiently. Any deviation from one of the two standard configurations can lead to
undesired activity.
thernet standard straight-through cable configurations used must be configured