KBC WESII User Manual

User Manual
WESII
Wireless Ethernet System
WESII Series
WESII User Manual
About This Users’ Guide
Intended Audience
This manual is intended for people who want to configure any of the WESII Series. You will need a basic knowledge of TCP/IP and wireless topology.
Related Documentation
Quick Start Guide
The Quick Start Guide is designed to help you get up and running. It contains basic information on setting up your individual WESII unit.
Technical Specification
The Technical specification is designed to provide you with all the technical specifications related to the WESII units.
KBC Networks’ Website
Please refer to www.kbcnetworks.com for additional support documentation and product certifications.
Feedback
We welcome all comments, questions and suggestions relating to our User Guides. Please contact us on:
Technical Department KBC Networks Ltd 25691 Atlantic Ocean Drive Suite B3 Lake Forest CA 92630
Email: techsupport@kbcnetworks.com
Thank you
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 1 of 140 www.kbcnetworks.com
WESII User Manual
Document Conventions
Warnings and Notes
These are how warnings and notes are shown is this Guide.
!Warning!
arnings tell you about things that could harm you or your device.
W
Note:
Notes tell you other important information or recommendations.
Example:
Examples are provided to help make the WESII set up straight forward.
Syntax Conventions
The WESII units may be referred to as the ‘device’, the ‘product’ or the ‘system’ in this guide.
<ENTER> denotes enter or return on your keyboard.
<*****> denotes that you need to select that option.
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 2 of 140 www.kbcnetworks.com
WESII User Manual
Safety Warnings
!Warning! For your safety please read the following warning notices and instructions.
Safety, Approvals and Regulatory Domain Information
Safety Instruction
For your protection, please read and observe all safety instructions before operating this system and keep this sheet and any additional instructions for future reference. Installation and Use
OBSERVE WARNINGS: All warnings in the operating instructions should be carefully followed. Do not make any modifications to the WESII unit, Power Injection Module (PIM), or any other KBC Networks electronic device, as the unit(s) will no longer comply with legal regulations and therefore void its warranty.
WATER AND MOISTURE: The WESII unit is weatherproof provided it is installed in accordance to the mounting details listed in section 2.4.3. However, further protection or housing is suggested for harsh environments, as moisture damage voids its warranty. The PIMs used in this system are NOT weatherproof. None of the modules in this system are waterproof and should never be submerged. Severe electrical shock, personal injury or damage to the equipment may result.
POWER SOURCE: Connect the equipment to a power source only of the type described on the operating instructions or as marked on the equipment. Excessive or insufficient current or voltage can cause extended trouble-shooting or even damage that could negate its warranty. The power supply cable should not be modified/extended due to the ability to use up to 100m of power over Ethernet cable. In addition, Ethernet cable running from the PIM to the WEM should be kept separated from high-voltage cables and/or transformers.
ATTACHMENTS: Use only KBC Networks’ supplied or recommended Power Injection Modules, Power Supplies, Cat5 Cables and weather seals and plugs.
WHEN NOT IN USE: Unplug the power if the equipment is left unattended or unused for long periods of time or during lightning storms.
REPLACEMENT PARTS: When replacement parts are required, use only replacement parts specified by KBC Networks. Unauthorized substitutions may result in damage to the system and could void the warranty.
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 3 of 140 www.kbcnetworks.com
WESII User Manual
FCC Required Information
Radio Frequency Interference Statement for Class B Digital Devices
This equipment has been tested and found to comply with the limits for an intentional radiator, pursuant to Part 15, subpart C of the FCC Rules. This equipment generates, uses and can radiate radio frequency energy. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. The limits are designed to provide reasonable protection against such interference in residential situations. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference but on or more of the following measures:
Re-orientate or relocate the receiving antenna of th
Increase the separation between the equipment and the affected receiver.
Connect the equipment and the affected receiver to power outlets on separate
circuits.
Consult the dealer or an experienced radio/TV technician for assistance.
Shielded cables must be used with this unit to ensure compliance with Class B FCC limits. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Changes or modifications not expressly approved by KBC could void the user’s authority to operate the equipment.
FCC Power Output Restrictions
The FCC does not require licensing to implement this device. License-free operation in the industrial, scientific and medical band is documented in FCC Rules Part 15.247. It is the responsibility of the individuals designing and implementing the radio system to ensure compliance with any pertinent FCC Rules and Regulations. This device must be professionally installed.
Exposure to Radio Frequency Fields
The WESII is designed to operate on the 5 GHz frequency band with up to 50 Watts EIRP maximum transmit power. This level of RF energy is above the Maximum Permissible Exposure (MPE) levels specified in FCC OET65:97-01. The following precautions must be taken during installation of this equipment:
The installed antenna must not be located in a manner that allows exposure of
the general population to the direct beam path of the antenna at a distance less than 20cm. Installation on towers, masts, or rooftops not accessible to the general population is recommended or alternatively mount the antenna in a manner that prevents any personnel from entering the area within 20cm from the front of the antenna.
It is recommended that the installer place radio frequency hazard warnings signs
on the barrier that prevents access to the antenna.
During installation and alignment of the antenna, do not stand in front of the
antenna assembly.
During installation and alignment of the antenna, do
of the antenna.
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 4 of 140 www.kbcnetworks.com
e affected radio or television.
not handle or touch the front
WESII User Manual
These simple precautions must be taken to prevent general population and installation personnel from exposure to RF energy in excess of specified MPE levels.
Industry Canada Restrictions
IC ID# 7849A-N523ESD
This Class A digital apparatus complies with Canadian ICES-003. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (E.I.R.P.) is not more than that permitted for successful communication. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
This device may not cause interference, and This device must accept any interference, including interference that may cause undesired operation of the device.
Cet appareil numérique de la classe A est confrome à la norme NMB-003 Canada. Pour réduire le risque d’interférence aux autres utilisateurs, le type d’antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire pour une communication réussie. Cet appareil est conforme à la norme RSS Industrie Canada exempts de licence norme(s). Son fonctionnement est soumis aux deux conditions suivantes: 17 Compliance
Cet appareil ne peut pas provoquer d’interférences et Cet appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif.
RF Exposure Warning
The antennas used for this transmitter must be installed to provide a separation distance of at least 37.2 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter.
Les antennes utilisées pour ce transmetteur doivent être installé en considérant une distance de séparation de toute personnes d'au moins 37.2 cm et ne doivent pas être localisé ou utilisé en conflit avec tout autre antenne ou transmetteur.
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 5 of 140 www.kbcnetworks.com
WESII User Manual
CE Regulatory Statement
Class B ITE:
This is a Class B product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Declaration of Conformity: KBC declares the following: Product Name: WESII Model No.: 802.11n Station conforms to the following Product Standards: This device complies with the Electromagnetic Compatibility Directive (89/336/EEC) issued by the Commission of the European Community. Compliance with this directive implies conformity to the following European Norms (in brackets are the equivalent international standards.) Electromagnetic Interference (Conduction and Radiation): EN 55022 (CISPR 22) Electromagnetic Immunity: EN 55024 (IEC61000-4-2, 3, 4, 5, 6, 8, 11) Low Voltage Directive: EN 60 950: 1992+A1: 1993+A2: 1993+A3: 1995+A4: 1996+A11: 1997. CE Mark: following the provisions of the EC directive. KBC also declares that: The wireless card in this product complies with the R&TTE Directive (1999/5/EC) issued by the Commission of the European Community. Compliance with this directive implies conformity to the following: EMC Standards: CE: EN 300 328-2, EN 300 826 (EN 301 489-17) EN 301 893.
CE marking on this product represents the product is in compliance with all directives that are applicable to it.
This equipment may be operated in the following countries:
Great Britain and Northern Ireland, Austria, Belgium, Denmark, Finland, France, Germany, Ireland, Italy, Netherlands, Norway, Portugal, Romania, Switzerland, Sweden
Installer Compliance Responsibility
Devices must be professionally installed and it is the professional installer's responsibility to make sure the device is operated within local country regulatory requirements.
Dynamic Frequency Selection (DFS) & Transmit Power Control (TPC):
DFS and TPC are requirements of the ETSI standard EN301 893 V1.5.1, the European Union’s harmonized radio standard for unlicensed devices operating in the 5150 – 5350 MHz and 5470 – 5725 MHz frequency bands. Radar detection is required when operating on channels whose nominal bandwidth falls partly or completely within the frequency ranges 5250 MHz to 5350 MHz or 5470 MHz to 5725 MHz. In addition devices using the 5600 – 5650 MHz band are subject to a 10 minute Channel Availability Check (CAC). The following table shows how this can affect connection times for certain frequencies:
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 6 of 140 www.kbcnetworks.com
WESII User Manual
Frequency (MHz)
5500 5505 5510 5515 5520 5525 5530 5535 5540 5545 5550 5555 5560 5565 5570 5575 5580 5585 5590 5595 5600 5605 5610 5615 5620 5625 5630 5635 5640 5645 5650 5655 5660 5665 5670 5675 5680 5685 5690 5695 5700
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 7 of 140 www.kbcnetworks.com
Channel Bandwidth
5MHz 10MHz 20MHz 20/40MHz 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 10 mins 2 mins 2 mins 2 mins 2 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 10 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins 2 mins
2 mins
WESII User Manual
Environmental Restrictions of Wireless Devices
KBC products are engineered to the highest standards and designed to work in a variety of wireless applications and environments. A wireless environment includes the site in which the product is installed, the installation including power and cabling as well as any extra materials that might be necessary to complete the wireless project. Due to the fact that environments and installations differ from site to site, KBC cannot control the variables required to ensure an ideal environment. Therefore, it is not possible to guarantee a successful application based on a drawing, application note, distance calculation, quote or other type of material that KBC may provide. Should a quote, drawing, etc. be made available, it is based on the performance of the WESII product in an ideal environment with clear line-of-sight, absence of 5 GHz interference and/or frequency multi-path reflection. Therefore, KBC cannot be held responsible should the products not operate as desired or should additional products be required to complete a project. In addition, should a particular environment restrict the usage of the WESII in any way, KBC offers a thirty (30) day return policy from date of shipment to the original purchaser if goods are returned in an ‘as new’ condition.
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 8 of 140 www.kbcnetworks.com
WESII User Manual
RoHS/WEEE Compliance Statement
European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product.
Instruction of Disassembly
Note: disassembling or opening of the WESII unit voids warranty.
Instruction of Disassembly of KBC Product (For EU Directive 2002/95/EEC­WEEE)
Tools required:
No. 1 Phillips screwdriver No. 2 Phillips screwdriver
Steps for disassembly:
Remove Serial Label adhesive Remove cover screws attaching top cover to radio module cavity. Remove tightening screws for printed circuit board (PCB). Take out all PCBs.
Note: W
hen a product reaches the end of its life – return to KBC.
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 9 of 140 www.kbcnetworks.com
WESII User Manual
General Public License Statement
You may have received from KBC Networks products that contained – in part – free software (software licensed in a way that ensures your freedom to run, copy, distribute, study, change and improve the software). Such products include the WESII Series of products.
As part of these products, KBC Networks may have distributed to you hardware and/or software that contained a version of free software programs developed by the Free Software Foundation, a separate not-for-profit organization without any affiliation to KBC Networks. See http://www.gnu.org/philosophy/free-sw.html for more details. If KBC Networks distributed any portions of these free software programs to you, you were granted a license to that software under the terms of either the GNU General Public License or GNU Lesser General Public License (“License”, copies of which are available from http://www.gnu.org/licenses/licenses.html). The Licenses allow you to freely copy, modify and redistribute that software without any other statement or documentation from us.
For at least one (1) year from the date of distribution of the applicable product or software, KBC Networks will provide to anyone who contacts us at the contact information provided below, for a charge of no more than our cost of physically performing source code distribution, a complete machine-readable copy of the complete corresponding source code for the free software programs used in the version of the programs that we distribute to you. The cost will be free if the delivery medium of the machine-readable copy is through the Internet.
Contact information:
Email: techsupport@kbcnetworks.com Tel: 949.297.4930 Address: 25691 Atlantic Ocean Drive Lake Forest, CA 92630
We do ask for your understanding regarding expected delivery timelines:
We will reply within 7 working days once the request has been made through email/telephone.
The default version sent will be the latest that we used in the firmware/programs.
Note: i
exceed 2 weeks.
t may take longer if an older version is requested. The waiting time will not
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 10 of 140 www.kbcnetworks.com
WESII User Manual
TABLE OF CONTENTS
ABOUT THIS USERS GUIDE…………………………………………………………………………………………1
Intended Audience…………………………………………………………………………………………………………………………..….…….…1 Related Documentation…………………………………………………………………………………………………………………..……………1
DOCUMENT CONVENTIONS……………………………………………………………………………………….2
Warnings and Notes………………………………………………………………………………………………………………………...………….2 Syntax Conventions ……………………………………………………………………………………………………………………………………..2
SAFETY WARNINGS……………………………………………………………………………………………………3
SAFETY, APPPROVALS AND REGULATORY DOMAIN INFORMATION………………………….3
Safety Instruction………………………………………………………………………………………………………………………….…………….3 FCC Required Information……………………………………………………………………………………………….…………………………..4 Industry Canada Restrictions……………………………………………………………………………………………………….……………...5 CE Regulatory Statement…………………………………………………………………………………………………….………………………6 Environmental Restrictions of Wireless Devices…………………………………………………………………….…………………….8
ROHS/WEEE COMPLIANCE STATEMENT…………………………………………………………………….9
Instructions of Disassembly……………………………………………………………………………………………………..…………………..9
GENERAL PUBLIC LICENSE STATEMENT………………………………………………………………….10
1 OVERVIEW…..………………………………………………………………….……………………………13
1.1 Introduction………………………………………………………………………………………………………………………………………13
1.2 General Technical Specification…………………………………………………………………………..…………………………….14
2 TYPICAL CONFIGURATIONS…………………………………………………….……………..…..16
2.1 Point-to-point…………………………………………………………………………………………………………………………………….16
2.2 Point-to-multipoint…………………………………………………………………………………………………………………………….17
2.3 Relay………………………………………………………………………………………………………………………………………………….18
2.4 Wi-Fi Access Point………………………………………………………………………………………………………………………………18
2.5 Mixed systems – WESII & MeshII………………………………………………………………………………………………….…...19
3 ANTENNA OPTIONS……………………………………………………………………………………….20
3.1 Omni-directional antennas………………………………………………………………………………………………………………..20
3.2 Integrated directional antenna options……………………………………………………………………………………………..20
3.3 External directional patch antenna options………………………………………………………………………………………..21
4 POINT-TO-POINT KITS…………………………………….……………………….………………….22
5 MOUNTING INSTRUCTIONS…………………………………………………………………………..23
5.1 Pole and wall-mount for integrated directional WESII units………………………………………………………………23
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 11 of 140 www.kbcnetworks.com
WESII User Manual
6 CONNECTIONS……………………………………………………………………………….……………..25
6.1 Physical Connections…………………..…………………………………………………….……………………………………………..25
6.2 Power Connections…………………………………………………………………………………………………………………………..26
7 LED STATUS……………………………………………….………………………………………………….28
7.1 Non-PoE WESII……………………………………………………………………………………………………………….…………………28
7.2 PoE WESII……………………………………………………………….………………………………………………………………………..28
8 CABLE ASSEMBLY………………………………………………………………………………………….29
8.1 Strain Relief Assembly…………………………………………………………………..……………………..……….………………….29
8.2 Configuring the Cable……………………………………………………………………………………………………………………….29
9 SETTING UP A BASIC LINK…………………………………………………………………………..31
9.1 Setting up a basic point-to-point link – United States & Canada…………………………………………….………..32
9.2 Setting up a basic point-to-point link – EMEA………………………….…………………………………………….………..40
9.3 Setting up a basic point-to-point link – Australia…………………….……………………………….…………….………..53
9.4 Setting up a basic point-to-multipoint link – United States & Canada………………………………...….………..61
9.5 Setting up a basic point-to-multipoint link – EMEA………………………….…………………………………….………..70
9.6 Setting up a basic point-to-point link – Australia…………………….……………………………………….…….………..83
10 INSTALLING ON A SITE………………………………………………………………………………….91
10.1 Line-of-sight………………………………………………………………………………………………………………………………..…...91
10.2 Spacing required when mounting WESII units…………………………………………………………………………………..93
10.3 Cable lengths when installing WESII units…………………………………………………………………………….……………94
10.4 Aligning the WESII units……………………………………………………………………………………….……………………………95
10.5 Configuring IP addresses on a site…………………………………………………………………………………………………….95
10.6 Replacing/adding a WESII Module from/to the existing application………………………………………………….96
11 GRAPHICAL USER INTERFACE………………………………………………………………………97
11.1 Connecting to the WESII GUI using a PC……………………………………………………..…………………..………………..97
11.2 WESII Menu Options………………………………………………………………………………………………………..……………….99
12 TROUBLESHOOTING……………………………………………………………………………………136
12.1 Visual Inspection……………………………………………………………………………………………..……………………………..136
12.2 Test Cable Connections…………………………………………………………………………………………………………………...136
12.3 GUI Tools…………………………………………………………………………………………………………………………………………136
12.4 Hard reset to defaults……………………………………………………………………………………………………………………..137
12.5 Contact KBC Technical Assistance…………………………………………………………………………………………………….138
13 WARRANTY………………………………………………………………………………………………….139
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 12 of 140 www.kbcnetworks.com
WESII User Manual
1. Overview
1.1 Introduction
This manual covers all the functions of the products that form KBC Networks’ WESII Series. The WESII Wireless Ethernet System is a wireless transmission system that provides a cable less transmission path for an Ethernet channel. They are designed for use in a wide range of operating temperatures in non-environmentally conditioned, outdoor applications. The primary function of the system is to replace Ethernet cables where it is not practical or cost-effective or where it is beyond distance limitations. WESII has been specifically designed to transmit constant streaming video but can also be used to send and receive standard Ethernet data packets or to operate as a WiFi Access Point. The units can be configured as a long range point-to-point wireless bridge or as a point-to-multipoint receiving antenna communicating to numerous transmitting Client/Station devices. This manual covers all operations and functions of the point-to­point and point-to-multipoint systems.
1.1.1.
The KBC WESII Series is a wireless transmission system that operates in the license free
2.4GHz & 5GHz bands and also in the 4.9GHz Public Safety band (only available in the US). The units are available as PoE or non-PoE with a range of antennas to suit applications. The units will support throughput of up to 99Mbps due to MIMO technology.
WESII
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 13 of 140 www.kbcnetworks.com
WESII User Manual
General Technical Specification
WESII Specification
Standards
IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX IEEE 802.3x Full Duplex IEEE 802.11a 5GHz
IEEE Standards
Radio
Frequency (MHz)
Frequency Operation
Power Output
Channel Capacity Selectable 5, 20 or 40MHz Modulation OFDM
Antennas
2dBi/5dBi (2.4GHz/4.9GHz & 5GHz) Omni-directional
9dBi (4.9GHz & 5GHz)
11dBi (2.4GHz)
17dBi (4.9GHz & 5GHz)
IEEE 802.11b 2.4GHz IEEE 802.11g 2.4GHz IEEE 802.11y 4.9GHz US Public Safety IEEE 802.11n MIMO IEEE 802.11h ETSI DFS & TPC IEEE 802.3af
USA & Canada: 2412 - 2472 4940 - 4990 5745 – 5825 Europe: 2412 - 2472 5500 - 5700 Auto-select User static selectable Dynamic Frequency Selection (ETSI DFS) 23dBm max1 Transmit Power Control (ETSI TPC)
Directional integrated patch Dual polarization Beamwidth: Azimuth: Horizontal 65°, Vertical 65° Elevation: Horizontal 33°, Vertical 33°
Directional integrated patch Dual polarization Beamwidth Azimuth: Horizontal 56°, Vertical 62° Elevation: Horizontal 38°, Vertical 26° Directional integrated patch Dual polarization Beamwidth: Azimuth: Horizontal 30°, Vertical 33° Elevation: Horizontal 17°, Vertical 17°
1
Territory specific.
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 14 of 140 www.kbcnetworks.com
WESII User Manual
System
Data throughput2 (max values – limited by 10/100 port)
HT5 HT20 HT40 17Mbps 99Mbps 99Mbps
Latency < 10 mS
Power
Power input (supplied by PIM)
24Vdc, 500mA
Reverse voltage protected Power method (non-PoE WESII) Passive PoE Power method (PoE WESII) IEEE 802.3af (PD) PoE cable spec 100m on 24AWG Cat5/5e/6/6e
Mechanical
Casing IP66
Dimensions (Patch L x W x D)
Weight
245mm x 245mm x 76mm
9.625” x 9.625” x 3”
420g
15oz Installation Wall-mount or pole-mount
Environmental
Operating Temperature -40° ~ +74°C / -40° ~ +165°F Storage Temperature -40° ~ +90°C / -40° ~ +194°F Operating Humidity 5% to 95% non-condensing
Connectors
10/100 Electrical 1 x RJ45
Approvals
FCC Part 15 subpart C Class B IC ID# 7849A-N523ESD CE Class B EN 55024 (IEC61000-4-2,3,4,5,6,8,11) Electromagnetic Immunity
EN 55022 (CISPR 22)
EN 60 950: 1992+A1; 1993+A2; 1995+A4; 1996+A1; 1997
Electromagnetic Interference (Conduction
and Radiation)
Low Voltage Directive
EN 300 328-2 EN 300 826 EN 301 489-17 EN 301 893 R&TT Directive (1999/5/EC)
2
Assumes an ideal environment with maximum signal rates & within receive
sensitivity specification.
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 15 of 140 www.kbcnetworks.com
WESII User Manual
2. Typical Configurations
The WESII units are available to work in the following configurations:
Point-to-point
Point-to-multipoint
Relay
Wi-Fi Access Point
Mixed systems
2.1 P
oint-to-Point
2.1.1 Non-PoE WESII
2.1.2 PoE WESII
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 16 of 140 www.kbcnetworks.com
WESII User Manual
2.2 Point-to-multipoint
2.2.1.
2.2.2.
Non-PoE WESII
PoE WESII
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 17 of 140 www.kbcnetworks.com
WESII User Manual
2.3 Relay
.4 Wi-Fi Access Point
2
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 18 of 140 www.kbcnetworks.com
WESII User Manual
2.5 Mixed systems – WESII & MeshII
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 19 of 140 www.kbcnetworks.com
WESII User Manual
3. Antenna Options
The WESII units are available with the following antennas:
2dBi/5dBi dual rated omni-directional antenna for 2.4GHz/4.9GHz & 5GHz
operation
9dBi integral patch antenna for 4.9GHz & 5GHz operation
11dBi integral patch antenna for 2.4GHz operation
17dBi integral patch antenna 4.9GHz 5GHz operation
9dBi external patch antenna for 4.9GHz & 5GHz operation
11dBi external patch antenna for 2.4GHz operation
17dBi external patch antenna for 4.9GHz & 5GHz opera
3.1 Omni-directional options
3.1.1 2dBi/5dBi
This is a dual frequency rated omni-directional antenna for 2.4GHz,
4.9GHz & 5GHz operation. At 2.4GHz the antenna has a gain of 2dBi and at 4.9GHz & 5GHz the antenna has a gain of 5dBi. The beamwidth of the antenna is 360°.
tion
3.2 Integrated directional patch antenna options
3.2.1 9dBi
This is an integral directional patch antenna option for 4.9GHz & 5GHz operation. The antenna is dual polarized. The beamwidth is:
Azimuth: Horizontal 65°, Vertical 65° Elevation: Horizontal 33°, Vertical 33°
3.2.2 11dBi
This is an integral directional patch antenna option for 2.4GHz operation. The antenna is dual polarized. The beamwidth is:
Azimuth: Horizontal 56°, Vertical 62° Elevation: Horizontal 38°, Vertical 26°
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 20 of 140 www.kbcnetworks.com
WESII User Manual
3.2.3 17dBi
This is an integral directional patch antenna option for 4.9GHz & 5GHz operation. The antenna is dual polarized. The beamwidth is:
Azimuth: Horizontal 30°, Vertical 33° Elevation: Horizontal 17°, Vertical 17°
3.3 External directional patch antenna options
External antennas can be attached to the antenna ports on the external antenna chassis and are provided with 2 x 1m cables. See section 6.1.2.
3.3.1 9dBi
This is an external directional patch antenna option for 4.9GHz & 5GHz operation, part number PAT5M-9. The antenna is supplied as a separate unit that contains 1 x 9dBi patch antenna and 2 x 1m cables. The antenna is dual polarized. The beamwidth is:
Azimuth: Horizontal 65°, Vertical 65° Elevation: Horizontal 33°, Vertical 33°
3.3.2 11dBi
This is an external directional patch antenna option for 2.4GHz operation, part number PAT2M. The antenna is supplied as a separate unit that contains 1 x 11dBi patch antenna and 2 x 1m cables. The antenna is dual polarized. The beamwidth is:
Azimuth: Horizontal 56°, Vertical 62° Elevation: Horizontal 38°, Vertical 26°
3.3.3 17dBi
This is an external directional patch antenna option for 4.9GHz & 5GHz operation, part number PAT5M. The antenna is supplied as a separate unit that contains 1 x 17dBi patch antenna and 2 x 1m cables. The antenna is dual polarized. The beamwidth is:
Azimuth: Horizontal 30°, Vertical 33° Elevation: Horizontal 17°, Vertical 17°
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 21 of 140 www.kbcnetworks.com
WESII User Manual
4. Point-to-point Kits
There are a number of WESII point-to-point kits that are available, details are below:
Part number Description Contents
WESII-KT 5GHz, point-to-point 17dBi kit 2 x 5GHz WESII 17dBi point-to-
point units
WESII-KT-9 5GHz, point-to-point 9dBi kit 2 x 5GHz WESII 9dBi point-to-
point units
WESII-KT-POE 5GHz, point-to-point kit with WESII PoE
units
WESII-KT-49 4.9GHz, point-to-point kit 2 x 4.9GHz WESII point-to-point
WESII-KT-49P 4.9GHz, point-to-point kit with WESII
PoE units
WESII-KT-ED 5GHz, point-to-point kit with encoder &
decoder
WESII-KT-P5 5GHz, point-to-point kit with 5 port PoE
switch & narrow temperature range PSU
WESII-KT-P5T 5GHz, point-to-point kit with 5 port PoE
switch & extended temperature range PSU
WESII-KT-P8 5GHz, point-to-point kit with 5 port PoE
switch & narrow temperature range PSU
WESII-KT-P8T 5GHz, point-to-point kit with 5 port PoE
switch & extended temperature range PSU
2 x 5GHz WESII 17dBi PoE point-to-point units
units
2 x 4.9GHz WESII PoE point-to­point units
2 x 5GHz WESII point-to-point units + KBC encoder & decoder
2 x 5GHz WESII point-to-point units + ESUL5P-D + DRP-120­48
2 x 5GHz WESII point-to-point units + ESUL5P-D + SDR-120­48
2 x 5GHz WESII point-to-point units + ESUG8P-D + DRP-480­48
2 x 5GHz WESII point-to-point units + ESUG8P-D + SDR-480­48
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 22 of 140 www.kbcnetworks.com
WESII User Manual
5. Mounting Instructions
WESII units are sold with all necessary mounting brackets and screws for installation on 76mm/3” diameter pole or wall mount.
Note: T
manual. The orientation must be as depicted below. Failure to comply with these instructions will invalidate warranty.
his equipment must be installed in accordance with the instructions found in this
5.1 Pole and wall-mount for WESII units
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 23 of 140 www.kbcnetworks.com
WESII User Manual
Qty Description
1 Bracket body
1 Pole clamp bracket
1 Connecting piece 1
1 Connecting piece 2
1 50mm, 1.98” long ¼” hex bolt
3 ¼” hex nuts
1 27mm, 1.06” long ¼” hex bolt
3 Flat washers 15mm, 0.59”
3 Locking washers 10mm, 0.39” long
1 U bolt
4 ¼-20 lock washers
Remove all packaging material
Remove 50mm bolt, flat washer, locking washer and hex nut.
Mount back plate to front WESII assembly plate.
Replace flat washer, locking washer and hex nut.
Remove ‘U’ shaped bolt.
Bolt the unit to the pole.
Up/Down Alignment offers one position when using the pre-fabricated channel
lock grooves on the swivel brackets. Directional antennas may require additional up/down alignment angles than those allowed on the pre-fabricated grooves. To achieve different angles, remove the 50mm Hex bolt. Insert the longer bolt and add the star washer. Re-connect and tighten.
Position the WESII unit to face the WESII unit at the other end of the link.
Carry out the alignment process – see Section 10.4 for instructions and Section 7
for LED status information.
When in the best position, tighten.
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 24 of 140 www.kbcnetworks.com
WESII User Manual
Front view
7
6. Connections
6.1 Physical Connections
6.1.1 Integrated Patch Antenna Chassis
1. Patch antenna cover
2. Serial number label
3. Internal RF module enclosure
4. Status LEDs
5. LAN port (RJ45)
6. Mounting block
7. Reset to default button
6.1.2 External Antenna Chassis
1. Antenna ports, attach screw down omni-directional antennas (for directional antennas, connect jumper LMR-200 cable)
2. Serial number label
3. Internal RF module enclosure
4. Status LEDs
5. LAN port (RJ-45)
6. Mounting block
7. Reset to default button
Rear view
Note: See Section 11.2.2.3 for details of how to carry out a hard reset to default
settings.
3
1
Rear view
2
7
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 25 of 140 www.kbcnetworks.com
WESII User Manual
6.2 Power Connections
WESII units are available as either PoE or non-PoE units.
6.2.1 Power Injector Module for the non-PoE WESII
Non-PoE WESII units are supplied with a mid-span Power Injector Module (PIM) and a standard 24Vdc, 500mA Power Supply Unit.
Note: The Power Injector Modules are not weatherproof units and must be protected
from moisture.
Power – Power supply input OUT – Connect to the WESII unit IN – Connect to the Ethernet device
For extreme temperature conditions there is also a KBC Networks Industrial DIN Rail power supply available, part number MDR-20-24. These units provide 24W at 24Vdc. These units need to be purchased separately, for further details please contact KBC Networks.
Note: K
powered using the supplied KBC Networks’ Power Injection Module.
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 26 of 140 www.kbcnetworks.com
BC Networks’ WESII non-PoE units are mid-span compliant and must be
WESII User Manual
6.2.2 Power for the PoE WESII
The PoE WESII units are IEEE 802.3af Powered Devices (PD) ie. they are powered from a Power Sourcing Equipment (PSE) such as an Ethernet switch which provides power on the Ethernet cable. There are a number of different Ethernet switches options with PoE available from KBC Networks, these can be purchased separately. Please contact KBC Networks for further information.
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 27 of 140 www.kbcnetworks.com
WESII User Manual
7. LED Status
7.1 Non-PoE WESII
1 Status/Signal Strength Indicator – 40 RSSI 2 Signal Strength Indicator – 30 RSSI 3 Signal Strength Indicator – 20 RSSI 4 Signal Strength Indicator – 10 RSSI 5 Ethernet Link Activity 6 Power
7.1.1 LED Boot Up Process
Upon connection of an Ethernet cable from the PIM to the unit, the Power LED 6
will light.
After 1 second RSSI LEDs 1, 2 & 3 illuminate.
RSSI LEDs 1, 2 & 3 then go off.
After 5 seconds the Ethernet Link Activity LED 5, illuminates.
At the same time the Signal Strength Indicator, LED 1 flashes for approximately 2
seconds.
LEDs 1 & 5 then switch off.
LED 5 comes on again and flashes intermittently showing that a connection is
established.
After approximately 1 – 2 minutes RSSI LEDs 1, 2, 3 & 4 will light depending on
the level of signal strength.
1 2 3 4 5 6
7.2 PoE WESII
1 Signal Strength Indicator – 40 RSSI 2 Signal Strength Indicator – 30 RSSI 3 Signal Strength Indicator – 20 RSSI 4 Signal Strength Indicator – 10 RSSI 5 Not used 6 Ethernet Link Activity 7 Power
7.2.1 LED Boot Up Process
Upon connection of an Ethernet cable from the PSE to the unit, the Power LED 7
will light.
After 1 second RSSI LEDs 1, 2 & 3 illuminate.
RSSI LEDs 1, 2 & 3 then go off.
After 5 seconds the Ethernet Link Activity LED 6, illuminates.
At the same time the Signal Strength Indicator, LED 1 flashes for approximately 2
seconds.
LEDs 1 & 6 then switch off.
LED 6 comes on again and flashes intermittently showing that a connection is
established.
After approximately 1 – 2 minutes RSSI LEDs 1, 2, 3 & 4 will light depending on
the level of signal strength.
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 28 of 140 www.kbcnetworks.com
WESII User Manual
8. Cable Assembly
8.1 Strain Relief Assembly
1. Thread the Cat 5 cable through the hole in the gland.
2. Pull the cable through and crimp on the RJ45 connector – see section 8.2
3. Connect the RJ45 connector into the WESII’s LAN port.
4. Tighten the clamping nut until the Ethernet cable is secured in the connector until it
is hand tight.
Note: the RJ45 connector does move slightly within the LAN port on the WESII unit this
allows the RJ45 connector to be connected to the Ethernet port more easily.
8.2 Configuring the Cable.
Note: The total length of cable from the WESII to the Ethernet device cannot exceed
100m (325 feet); however, for a non-PoE WESII unit the PIM can be located anywhere along the overall 100m of cable. KBC Networks recommends shielded Ethernet cables for the cable connecting the PIM to the WESII unit. Any cable exposed to the elements should also be outdoor rated.
1. Determine the length of cable that will be required and where the PIM will be
located.
2. Slide the weatherproof connector over the cable jacket before crimping the
connector. See Section 8.1 for the assembly instructions. If needed, see below for color-code standards to configure the correct type of Ethernet cable.
Note: E
to one of the Ethernet standards (568-A or 568-B) in order for the WESII system to operate efficiently. Any deviation from one of the two standard configurations can lead to undesired activity.
thernet standard straight-through cable configurations used must be configured
Manual-WESII-Rev1403 Copyright © KBC Networks 2014 Page 29 of 140 www.kbcnetworks.com