WES2HT 17dBi
Welcome to KBC Networks’ Quick Start Guide for the WES2HT point­to-point host / client with 17dBi antennas for 5GHz operation.
This document provides some tips to get up and running. More detailed information can be found on our website (see Downloads).
Features:
5GHz operation
MIMO technology
Dynamic Frequency Selection &
Transmission Power Control
Antenna alignment & signal survey tools
IP66 casing
Gigabit Ethernet
System Contents
1 WES2HT Single Point host/client module with PIM
and power supply 1 Cable weather-proof kit assembly 1 Wall or pole-mount bracket and assembly kit
including: 1 Bracket body 1 Pole clamp bracket 1 Connecting piece 1 1 Connecting piece 2 1 50mm, 1.98” long ¼” hex bolt 2 ¼” hex nuts 1 27mm, 1.06” long ¼” hex bolt 2 Flat washers 15mm, 0.59” 2 Locking washers 10mm, 0.39” long 1 U bolt 2 ¼-20 lock washers
Point-to-Point Client / Host
Installation manual: for other features & functions:
http://www.kbcnetworks.com/downloads
Specification Sheets:
http://www.kbcnetworks.com/downloads
Equipment Required for Physical Deployment
Two straight-through Ethernet cables are required for connection from the WES2HT to PoE enabled switches or PIMs.
Note:
WES2HT requires a CAT6 or Gigabit Ethernet
cable. KBC recommends shielded outdoor rated Ethernet cables when connecting near power outlets & when exposed to the elements.
Physical Deployment
This equipment must be installed and operated in accordance with instructions found in the KBC
be as depicted, failure to comply with these instructions will invalidate warranty.
Note:
The WES2HT comes pre-configured from the
factory and does not require custom settings for basic operation. Please refer to the documentation provided for pre-set configuration settings.
If custom settings are required and/or desired, please set the custom configurations as follows:
Configuring the Host unit:
1. Connect the PIM, PoE 802.3af or 802.3at compliant sourcing device to the Ethernet port of the WES2HT Host PoE unit.
2. Allow 60s for the unit to boot.
3. Verify that the static IP address on the laptop is set to 192.168.1.x subnet.
4. Open a web browser to access the Host on its 192.168.1.200 IP address; this is the default address for the unit.
5. Enter the following to access the GUI:
ID: admin Password: admin
Note: Ensure that all other network interface
connections including your laptop Wifi are disabled.
6. Select: <Interference Analyzer> to
determine which frequencies are available in your location.
Select: one of the available channels Select: <Apply Settings> Select: <Save>
Configuring the Client unit:
7. Connect the PIM, PoE 802.3af or 802.3at compliant sourcing device to the Ethernet port of the WESII Client PoE unit.
8. Allow 60s for the unit to boot.
9. Verify that the static IP address on the laptop is set to 192.168.1.x subnet.
10. Open a web browser to access the Host on its 192.168.1.201 IP address; this is the default address for the unit.
11. Enter the following to access the GUI:
ID: admin Password: admin
Note: Ensure that all other network interface
connections including your laptop Wifi are disabled.
QSG-WES2HT_17dBi_Pt-Pt_Host_Client-Rev1311A Copyright © KBC Networks Ltd. 2013
www.kbcnetworks.com
Note: The Client will not need the frequency selection
and SSIDs
contact KBC Networks
Parameter
Setting
Compliance
but will need the country setting, SSID and the channel spectrum width to be the same as the Host.
12. Allow up to 2 minutes for the units to connect to each other.
13. Note down all the MAC addresses used in the application for future reference.
Note: Point-to-point Host/APs and their respective
Clients must be MAC locked to each other.
Topology/Mapping Option
3. In the Topology page to upload a background image Select: <Browse>
4. Choose a file
Select: <Upload>
Note:
5. Move the nodes around on the page to
6. Hover over the node to display details of the
The image size is limited to 120kB and must be JPEG
or GIF format.
represent their physical locations. Select: <Save>
radio link.
Default Configurations
FCC Industry Canada RF Exposure Warning CE Marking RoHS/WEEE Compliance Statement Installer Compliance Responsibility
Devices must be professionally installed and it is the professional installer's responsibility to make sure the device is operated within local country regulatory requirements.
Please visit our website at www.kbcnetworks.com for full compliance statements and information
If you have chosen the mapping option on your unit you will be able to view system configuration and health all on one page. Mapping is purchased as a separate option; please if you would like this option.
Note:
Only KBC nodes are shown on the topology page
Configuring the Topology/Mapping Option
1. In the web browser
Select: ‘Basic Network’ Enter: enter a gateway address
Note:
network device that is connected to any one of the system node’s Ethernet port.
2. Once the complete system has been
Note:
gateway. All nodes will have the same gateway IP address which is set to the gateway shown connected to Node 1.
The gateway address must be a ping-able
configured and is properly connected, a generic map will be created in the Topology page.
The router symbol is used to represent the
LAN IP Address 192.168.1.200 (Host/AP)
GUI User ID admin
GUI Password admin
SSID KBC-WES2HT Pre-shared Key 11111111
Frequency selection (Host only)
Bandwidth 20/40 Long Range Parameters Enabled
Note:
settings and disable the MAC lock feature.
A restore to defaults will erase custom configuration
192.168.1.201 (Client)
Auto
WES2HT Status Indicators
1. Signal Strength Indicator – 40 RSSI
2. Signal Strength Indicator – 30 RSSI
3. Signal Strength Indicator – 20 RSSI
4. Signal Strength Indicator – 10 RSSI
5. Not used
6. Not used
7. Ethernet Link Activity
8. Power
Need Help?
Visit our website http://www.kbcnetworks.com or contact your nearest KBC office or dealer:
USA
Phone: +1 949 297 4930 Toll Free: +1 888 366 4276 Email:
techsupport@kbcnetworks.com
EMEA
Phone: Email: emeatechsupport@kbcnetworks.com
+44(0)1622 618787
APAC
Phone: +65 98463323 Email: apactechsupport@kbcnetworks.com
QSG-WES2HT_17dBi_Pt-Pt_Host_Client-Rev1311A Copyright © KBC Networks Ltd. 2013
www.kbcnetworks.com
Loading...