KBC FCHA1-M1T-R-WSB User Manual

Fiber Optical Transceiver
for Up-the-Coax
User Manual
Table of Contents
0. Product Type..............................................................................................1
1. Overview.....................................................................................................1
1.1 Introduction ..........................................................................................................1
1.2 Features ...............................................................................................................1
1.3 Technical Specification ....................................................................................... 2
2. Package Contents ......................................................................................2
3. Product Enclosure.....................................................................................3
3.1 Transmitter ........................................................................................................... 3
3.2 Receiver ............................................................................................................... 4
4. Caution.......................................................................................................6
5. Typical Application....................................................................................6
6. Dimensions.................................................................................................8
7. W arranty....................................................................................................9
8. Instruction of Disassembly .....................................................................10
0. Product Type
Configuration
User Manual
Fiber
SM MM
ST/PC SC/PC FC/PC
1. Overview
1.1 Introduction
The KBC FCHA1 series video and data transmission system is designed for full
compatibility with ‘Up-the-Coax’ video/data systems from major manufactures such as
Bosch Bi-Linx., and others. This series supports simultaneous 10-bit digitally encoded
video and “up the coax” data over one multimode or singlemode fiber. Plug-and-play
design ensures ease of installation requiring no electrical or optical adjustments. This
series features two optional contact closure circuits that allow two additional devices
such as dome tamper switches or alarm inputs to be added. LED indicators are
provided to clearly show the operaional status of the unit.This series is available in
wall mount ,rack mount,or 3U classis card configurations.
1.2 Features
z Transmission of Video and ‘Up-the-Coax’ Data
z 10-Bit Digitally Encoded Video Transmission
z Exceeds RS-250C Short-Haul Transmission
z 2 channel Bi-Directional Contact Closure circuits optional
z BBV , Bosch ,Pelco or Honeywell selectable
z No Electrical or Optical Adjustments Required
z LED indicators are provided quick diagnosis of all system parameters
z Singlemode & Multimode models.
Manual-FCHA1-Rev1009.pdf Page 1 of 9 www.kbcnetworks.com Copyright © KBC Networks Ltd
User Manual
z Wall mount ,rack mount and 3U classis card configerations
z Special technique is used to extend Bi-Linx transmission distance, the distance
depends on optical power.
1.3 Technical Specification VIDEO
Signal Level 1.0V
typical, 1.5V
P-P
max.,75
P-P
Sampling Resolution 10 bit Differential Gain < 1% Differential Phase < 1º Signal to Noise Ratio (SNR) 67dB typical Connector Type BNC
CONTACT CLOSURE
Contact Max. voltage/current 25V/0.8A(DC), 110V/0.4A(AC) Connector Type Terminal
OPTICAL SM MM
Wavelength 1310nm 1550nm 1310nm 1550nm Optical Out Power -10 dB -10 dB -11 dB -11 dB Optical Sensitivity
-30 dB -30 dB -26 dB -23 dB
Effective Fiber power budget 20 dB 12 dB Fiber Type 9/125μm 62.5/125μm Distance 0 ~ 30km 0 ~ 4km
GENERAL
Operating Temperature -40 ~ 70˚C / -40 ~ +158ºF Relative Humidity 0 ~ 95% non-condensing
Power Supply Adaptor
Input: 100~240VAC, 50/60Hz,0.5A
Output: +12VDC, 2A Mean Time Between Failure(MTBF) > 100,000hrs Enclosure Color Silver Housing Wall mount
2. Package Contents
One Transmitter One Receiver One User Manual
Manual-FCHA1-Rev1009.pdf Page 2 of 9 www.kbcnetworks.com Copyright © KBC Networks Ltd
3. Product Enclosure
3.1 Transmitter
Connectors:
User Manual
C1: Channel 1 Contact Closure input.
C2: Channel 1 Contact Closure output.
C3: Channel 2 Contact Closure input.
C4: Channel 2 Contact Closure output.
Terminal pins assignment:
Channel 1 contact closure input “A”
1
Channel 1 contact closure input “B”
2
Channel 1 contact closure output “A”
3
Channel 1 contact closure output “B”
4
Channel 2 contact closure input “A”
5
Channel 2 contact closure input “B”
6
Channel 2 contact closure output “A”
7
Channel 2 contact closure output “B”
8
DIP Switch setup table:
DIP Switch pin name
D1 D2
D3,D4
Bosch or Pelco BBV Honeywell
OFF OFF ON
OFF ON ON
Non functional/Reserved
Manual-FCHA1-Rev1009.pdf Page 3 of 9 www.kbcnetworks.com Copyright © KBC Networks Ltd
Connectors:
DC or AC Power Supply between 12V and 24V can be used on this product.
DC:
: +12VDC~+24VDC
: Power Supply Ground
AC:
There is no difference between +/-; the power supply can be connected into
the device directly.
FIB: Fiber Optic connector.
GND: Ground pin.
LEDs Definition:
User Manual
POW: Power Supply. On if power input is in OK. FIB: Fiber Link. Off if the link is in OK. V: Video. On if video input is in OK. C1: Channel 1 Contact Closure input. On if the contact input is closed. C2: Channel 1 Contact Closure output. On if the contact output is closed. C3: Channel 2 Contact Closure input. On if the contact input is closed. C4: Channel 2 Contact Closure output. On if the contact output is closed.
The other is reserved.
3.2 Receiv er
Manual-FCHA1-Rev1009.pdf Page 4 of 9 www.kbcnetworks.com Copyright © KBC Networks Ltd
Connectors:
C1: Channel 1 Contact Closure input.
C2: Channel 1 Contact Closure output.
C3: Channel 2 Contact Closure input.
C4: Channel 2 Contact Closure output.
Terminal pins assignment:
Channel 1 contact closure input “A”
1
Channel 1 contact closure input “B”
2
Channel 1 contact closure output “A”
3
Channel 1 contact closure output “B”
4
Channel 2 contact closure input “A”
5
Channel 2 contact closure input “B”
6
Channel 2 contact closure output “A”
7
Channel 2 contact closure output “B”
8
Connectors:
DC or AC Power Supply between 12V and 24V can be used on this product.
DC:
User Manual
: +12VDC~+24VDC
: Power Supply Ground
AC:
There is no difference between +/-; the power supply can be connected into
the device directly.
FIB: Fiber Optic connector.
GND: Grounded pin.
Manual-FCHA1-Rev1009.pdf Page 5 of 9 www.kbcnetworks.com Copyright © KBC Networks Ltd
User Manual
LEDs Definition:
POW: Power Supply. On if power input is in OK. FIB: Fiber Link. Off if the link is in OK.
V: Video. On if video output is in OK. C1: Channel 1 Contact Closure input. On if the contact input is closed. C2: Channel 1 Contact Closure output. On if the contact output is closed. C3: Channel 2 Contact Closure input. On if the contact input is closed.
C4: Channel 2 Contact Closure output. On if the contact output is closed.
The other is reserved.
4. Caution
Switch off all power supply before installation.
Ensure fiber is properly aligned to the Fiber connector.
Do NOT stare at the fiber core.
5. Typical Application
Coax Cable
Manual-FCHA1-Rev1009.pdf Page 6 of 9 www.kbcnetworks.com Copyright © KBC Networks Ltd
Coax Cable
User Manual
Manual-FCHA1-Rev1009.pdf Page 7 of 9 www.kbcnetworks.com Copyright © KBC Networks Ltd
6. Dimensions
User Manual
115.5
155
3.8
111
36
118
Manual-FCHA1-Rev1009.pdf Page 8 of 9 www.kbcnetworks.com Copyright © KBC Networks Ltd
User Manual
7. Warranty
5 years warranty for product only. Repair
Please contact your local distributors when product is defective. Please apply
RA in advance and prepay shipping cost when returning the defective product to us. We will pay the cost for sending it back to you.
Please attach a statement clearly describing the problem.
We will repair defective product under warranty free of charge to our customer. Any unauthorized modification of hardware and software voids the warranty. Warranty does not cover mishandling and/or abuse of the product.
Products comply with the following Safety Label for International Fiber Communication Equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful Interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at this own expense.
Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Manual-FCHA1-Rev1009.pdf Page 9 of 9 www.kbcnetworks.com Copyright © KBC Networks Ltd
User Manual
8. Instruction of Disassembly
Instruction of Disassembly of KBC Product
(For EU Directive 2002/95/EECWEEE)
Tools Required:
1) 5 mm flat tip screwdriver
2) Φ3 cross tip screwdriver
3) Φ5 cross tip screwdriver
4) Size small snip nose pliers
5) 15 mm spanner
Steps for Disassembly:
1) Remove tightening screws of box cover (1 or 4-8 screws in general);
2) Remove lock nut for BNC with spanner;
3) Remove cover plate;
4) Remove tightening screws for printed circuit board (PCB);
5) In case the assembly has more than one PCB then continue removing the remain tightening screws until none left;
6) Use snip nose pliers to loose the nut of flange and then remove optic cable connector (jump wire);
7) Snip off power conducting cable and remove power switch /jack/etc.;
8) Take out all PCBs;
9) Disassembly of product completed.
NoticeWhen a product reaches the end of it’s lifereturn to KBC
Manual-FCHA1-Rev1009.pdf Page 10 of 9 www.kbcnetworks.com Copyright © KBC Networks Ltd
Headquarters:
KBC Networks, Ltd.
25691 Atlantic Ocean Drive,
Suite B3
Lake Forest, CA 92630
U.S.A.
Main: 1-949-297-4930
Fax: 1-949-297-4933
KBC Networks Ltd., EMEA
Carlton Suite, Barham Court
Teston, Maidstone
Kent ME18 5BZ
United Kingdom
Office: +44(0)1622618787
Fax: +44(0)2071008147
Email: info@kbcnetworks.com
Web: www.kbcnetworks.com
Loading...