KBC ESUG8P User Manual

Ethernet Switch
ESUG8P
User Manual
Ethernet Switch User Manual
TABLE OF CONTENTS
1 OVERVIEW ................................................................................. 3
1.1
I
NTRODUCTION
............................................................................................ 3
1.1.1 ESUG8P ............................................................................................. 3
1.2
T
ECHNICAL SPECIFICATION
.............................................................................. 4
2 INSTALLATION ............................................................................. 5
2.1
P
ACKAGE CONTENTS
2.2
C
ONFIGURATIONS
2.2.1 Physical Connections ........................................................................... 6
2.3
I
NSTALLATION METHOD
2.3.1 DIN Rail Mount ................................................................................... 7
2.3.2 Wall-mount ........................................................................................ 7
2.4
E
2.5
2.6
2.7
2.8
THERNET
P
OWER CONNECTIONS
F
AULT ALARM CONTACT
DIP S
LED S
RJ45 C
WITCH FUNCTION
TATUS
............................................................................................... 9
...................................................................................... 5
......................................................................................... 5
................................................................................... 7
ONNECTIONS
.................................................................................... 8
................................................................................... 8
.................................................................................. 9
......................................................................... 7
3 TROUBLESHOOTING .................................................................... 10
3.1
S
ELF-TESTING
........................................................................................... 10
4 SYSTEM EXAMPLE ....................................................................... 11
5 DIMENSIONS ............................................................................. 11
6 WARRANTY .............................................................................. 12
6.1
W
6.2
6.3
ARRANTY INFORMATION
C
LASS A
FCC ....................................................................................................... 13
ITE ............................................................................................ 13
.............................................................................. 12
7 INSTRUCTION OF DISASSEMBLY ...................................................... 13
Manual-ESUG8P_Series_HW-Rev1112 Copyright © KBC Networks Ltd. Page 2 of 14 www.kbcnetworks.com
Ethernet Switch User Manual
1 Overview
1.1 Introduction
This manual covers the ESUG8P series. KBC Networks’ ESUG8P products are high performance, unmanaged, eight gigabit port industrial PoE Ethernet switches designed for use in a wide range of operating temperatures in non­environmentally conditioned, industrial applications. The units have redundant power supply terminals and an alarm output. All copper ports are automatically configured and the plug-and-play design provides ease and speed of installation.
1.1.1 ESUG8P
The ESUG8P provides connectivity for up to eight, 10/100/1000 RJ45 twisted pair copper ports, with all eight ports capable of simultaneously supplying IEEE802.3at PoE. Each port supports a self-adaptive function allowing it to be configured to 10Base-T or 100Base-TX, full or half duplex operation mode. It is available as either DIN rail or wall-mount configurations.
Manual-ESUG8P_Series_HW-Rev1112 Copyright © KBC Networks Ltd. Page 3 of 14 www.kbcnetworks.com
Ethernet Switch User Manual
1.2 Technical Specification
Switching
Mode Store-and-forward
Switching rate 14,881pps, 148,810pps, 1,488,100pps
Backplane switching bandwidth 16Gbps
Mac address table 2k
ESUG8P
Ports
Copper
Physical port 8 x shielded RJ45
RJ45 port 10BASE-T/100Base-TX/1000Base-T
Auto-negotiation
Standard IEEE 802.3
Transmission distance <100m
PoE
Physical port 8 x shielded RJ45
Standard IEEE 802.3at
Power supplied (per port) 30W @ +50Vdc
Electromagnetic compatibility
Interference EN55022 Class A
Immunity IEC61000-6-2
Power
Input voltage
Power consumption
Power supply Supplied separately
50 - 57Vdc
8W (no PoE) 250W ( full load PoE)
Environmental
Operating temperature -40°C - +74°C / -40°F - +165°F
Storage temperature -40°C - +74°C / -40°F - +165°F
Relative humidity 5% - 95%, Non-condensing
Mean Time Between Failure >300,000 hours
Mechanical
Dimensions (W x H x D) 27mm x 145mm x 95 mm
1.07” x 5.71” x 3.74”
Protection class rating IP30
Weight
Manual-ESUG8P_Series_HW-Rev1112 Copyright © KBC Networks Ltd. Page 4 of 14 www.kbcnetworks.com
390g
13.75oz
Ethernet Switch User Manual
2 Installation
2.1 Package Contents
Ethernet switch fitted with DIN rail mount.
2 x Wall-mount brackets with screws
Pluggable terminal block
Quick Start Guide
Note: A 50 – 57Vdc PSU is required but supplied separately.
Please contact you dealer or distributor if a part is missing or damaged.
2.2 Configurations
Products are available in either DIN rail or wall-mount packages, with the following configurations:
Product Type DIN Rail Wall-mount
ESUG8P
Manual-ESUG8P_Series_HW-Rev1112 Copyright © KBC Networks Ltd. Page 5 of 14 www.kbcnetworks.com
Ethernet Switch User Manual
Front View
2.2.1 Physical Connections
Manual-ESUG8P_Series_HW-Rev1112 Copyright © KBC Networks Ltd. Page 6 of 14 www.kbcnetworks.com
Ethernet Switch User Manual
2.3 Installation Method
2.3.1 DIN Rail Mount
Remove all packaging material.
Attach the device to a DIN rail.
Attach copper cables as required.
Insert the male power block (attached to the supplied in-line PSU) to the
female power socket on the device and tighten the terminal locking screws
using a flathead screw driver.
See Section 2.7 for LED status.
2.3.2 Wall-mount
Remove all packaging material.
Unscrew the DIN rail mounting plate from the switch taking special care to
retain the 3 screws using a Phillips No.1 or No.2 screwdriver.
Attach the supplied wall mount plates to the switch using the screws that
have just been removed from the DIN rail mounting plate with a Phillips
No.1 or No.2 screwdriver.
Position the unit on the required, flat surface and secure with screws via the
mounting plate holes. Screws are not provided.
Attach copper cables as required.
Insert the male power block (attached to the supplied in-line PSU) to the
female power socket on the device and tighten the terminal locking screws
using a flathead screw driver.
See Section 2.7 for LED status.
2.4 Ethernet RJ45 Connections
Each RJ45 port is adaptive and supports auto MDI/MDI-X connection. They can be connected by straight through or cross-over cables to terminal devices, servers, hubs or other switches. Each switch supports IEEE802.3x and IEEE802.3ab so the optimum transmission mode (either half-duplex or full-duplex) and data rate (10Mbps, 100Mbps or 1000Mbps) will be selected automatically.
Manual-ESUG8P_Series_HW-Rev1112 Copyright © KBC Networks Ltd. Page 7 of 14 www.kbcnetworks.com
Ethernet Switch User Manual
24Vdc, 1A resistance
2.5 Power Connections
A 6 pin, power terminal block should be used to connect the power cable to the unit.
Figure 2.1 Power connections
Contact number Connections
1 PWR2: -
2 PWR2: +
3 Fault alarm contact
4 Fault alarm contact
5 PWR1: -
6 PWR1: +
Note:
otherwise the Power Fault Alarm will be lit.
If only using one power source, connect pin 1 to pin 5 and pin 2 to pin 6
2.6 Fault Alarm Contact
The fault alarm contacts are in the middle of the 6 pin, screw block terminal on pins 3 &
4. An open circuit will occur if a power failure is detected.
Load
P-Fail
External power
Fig 2.2 Fault Alarm Contacts
Manual-ESUG8P_Series_HW-Rev1112 Copyright © KBC Networks Ltd. Page 8 of 14 www.kbcnetworks.com
Ethernet Switch User Manual
2.7 DIP Switch Function
DIP-1
DIP-2 Description
OFF OFF Power failure relay alarm & P-Fail disabled
ON OFF P1 failure: relay alarm & P-Fail enabled
OFF ON P2 failure: relay alarm & P-Fail enabled
ON ON P1 or P2 failure: relay alarm & P-Fail enabled
2.8 LED Status
LED Status Description
P1
P2
P-Fail
ON
OFF
ON
OFF
ON
OFF
Power is supplied to the unit
No power to the unit
Power is supplied to the unit
No power to the unit
Power to P1 or P2 has failed
Power is functioning to both or none of the powered devices
Ethernet RJ45 Port Status LED
Each RJ45 Ethernet port has two green indicators. The lower green lamp indicates whether power is being supplied to a PD and the upper green lamp indicates port link state.
Green (lower)
Green (upper)
ON
OFF
ON
FLASH
OFF
The port is supplying power to the powered device
There is no powered device attached or the power to the device has failed
Effective network connection has been established for the port
Data traffic is passing through the port
No effective network connection has been established for the port
Manual-ESUG8P_Series_HW-Rev1112 Copyright © KBC Networks Ltd. Page 9 of 14 www.kbcnetworks.com
Ethernet Switch User Manual
3 Troubleshooting
3.1 Self-testing
When the device is powered on, the top green LED on the RJ45 ports will flash once
then go out, the bottom green LED on the RJ45 will light in succession, starting at P1
to P8, each port will continue to light in turn unless it is connected to an external
device. The power (P1 & P2) and P-Fail LEDs will be lit according to the power being
supplied to the unit and the DIP switch selection (see Section 2.7).
If problems are encountered when using this Ethernet switch please check the
following:
Verify that the correct power supply unit is being used; this unit requires a
48Vdc supply.
Ensure that the correct cables are being used to construct your network:
o Unshielded Twisted Pair or Shielded Twisted Pair for RJ45 connections
o 100Ω Cat 3 cable or above for 10Mbps connections
o 100Ω Cat 5 cable or above for 100Mbps connections
o 100Ω Cat 5e cable or above for 1000Mbps connections
o Twisted pair connection must not exceed 100m (328 feet)
See section 2.7 for LED status indicators.
Manual-ESUG8P_Series_HW-Rev1112 Copyright © KBC Networks Ltd. Page 10 of 14 www.kbcnetworks.com
Ethernet Switch User Manual
WESII
Power
Up to 7 IP Cameras
8 Port
4 System Example
(IEEE 802.3at Compliant powered)
Switch
Client
5GHz
Injection Module
Figure 4.1 ESUG8P Typical System Application
5 Dimensions
Manual-ESUG8P_Series_HW-Rev1112 Copyright © KBC Networks Ltd. Page 11 of 14 www.kbcnetworks.com
Ethernet Switch User Manual
6 Warranty
6.1 Warranty Information
KBC extends the following LIMITED WARRANTY to the original owner/purchaser of this product as follows:
- Five years from the date of initial sale for Ethernet switches.
- Two years from the date of initial sale for all wireless and other network products.
- Five years from the date of initial sale for all fiber products.
1) If, within the specified warranty period, this product, or any part or portion thereof, shall prove upon examination by KBC, to be defective in material or workmanship, KBC will repair or replace such part or portion at KBC’s option. The warranty period on the repaired or replaced part or portion of this product shall be limited to the unexpired term of the original warranty. The buyer shall be responsible for all shipping and transportation of the product to KBC for any performance under this warranty.
2) Conditions and Exceptions: a) Any accident to this product, any misuse or abuse, alternation, use in modified
form, or any attempt to repair this product shall void this warranty. These conditions to the warranty include, but are not limited to, incorrect power connections, physical damage due to mechanical shock, exposure to moisture, and circuit modification.
b) SHOULD THIS PRODUCT PROVE DEFECTIVE FOLLOWING PURCHASE, THE BUYER,
NOT THE MANUFACTURER, DISTRIBUTOR, OR RETAILER, ASSUMES THE ENTIRE COST OF ALL SERVICING OR REPAIR, EXCEPT AS OTHERWISE PROVIDED BY THE TERMS OF THIS WARRANTY.
c) FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY ON THIS PRODUCT, THE
BUYER IS LIMITED TO THE FOLLOWING DAMAGES. (1) THE COST OF LABOR TO REPAIR OR REPLACE DEFECTIVE PARTS OR PORTIONS OF THIS PRODUCT, AND (2) THE COST OF THE REPAIRED OR REPLACE PARTS OR PORTIONS OF THIS PRODUCT.
d) NO OTHER EXPRESSED OR IMPLIED WARRANTIES HAVE BEEN MADE OR WILL BE
MADE ON BEHALF OF KBC WITH RESPECT TO THE SALE, REPAIR, INSTALLATION, OPERATION, OR REPLACEMENT OF THIS PRODUCT. KBC DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OF THIS PRODUCT OR ITS FITNESS FOR ANY PURPOSE, AND THE BUYER AGREES THAT THIS PRODUCT IS SOLD “AS IS” AND THAT THE ENTIRE RISK OF QUALITY AND PERFORMANCE OF THIS PRODUCT IS WITH THE BUYER, EXCEPT AS OTHERWISE PROVIDED BY THE TERMS OF THIS WARRANTY.
e) Some states/jurisdictions do not allow exclusions or limitations of incidental or
consequential damages, or limitations on how long an implied warranty lasts, so the above exclusions or limitations may not apply to you.
f) If you do not wish to be bound by any of the provisions in this warranty, please
return the product(s) immediately.
3) Contact your dealer regarding return authorizations for out of warranty repairs and any further product information.
Manual-ESUG8P_Series_HW-Rev1112 Copyright © KBC Networks Ltd. Page 12 of 14 www.kbcnetworks.com
Ethernet Switch User Manual
6.2 Class A ITE
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
6.3 FCC
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful Interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at this own expense.
7 Instruction of Disassembly
Instruction of Disassembly of KBC Product
(For EU Directive 2002/95/EEC-WEEE)
Tools required:
No. 1 Phillips screwdriver
No. 2 Phillips screwdriver
Steps for disassembly:
1. Remove tightening screws of box cover (8 screws).
2. Remove cover plate.
3. Remove tightening screws for printed circuit board (PCB).
4. Take out all PCBs.
Notice: When a product reaches the end of its life – return to KBC.
Manual-ESUG8P_Series_HW-Rev1112 Copyright © KBC Networks Ltd. Page 13 of 14 www.kbcnetworks.com
data delivered
KBC Networks
25691 Atlantic Ocean Drive
Suite 3B
Lake Forest, CA 92630
U.S.A
Americas
Phone: 1-949-297-4930
Fax: 1-949-297-4933
KBC Networks Ltd., EMEA
KBC Networks Ltd.
Barham Court
Teston, Maidstone
Kent, ME18 5BZ
United Kingdom
Phone: +44(0)1622 618787
Fax: +44(0)20 7100 8147
Email:
Web: www.kbcnetworks.com
info@kbcnetworks.com
Loading...