Kaz V971N IB User Manual

10. Cleaning and Storage
Use an alcohol swab or cotton swab moistened with alcohol (70% Isopropyl) to clean the thermometer casing and the measuring sensor lens. Ensure that no liquid enters the interior of the thermometer. Never use abrasive cleaning agents, thinners or benzine for cleaning and water or other cleaning liquids. Take care not to scratch the surface of the display. After cleaning, replace Protective Cap.
Remove the battery from the instrument if it is not required for extended periods of time in order to avoid damage to the thermometer resulting from a leaking battery.
11. Replacing the Battery
The VICKS Ear Thermometer is supplied with two AAA batteries. Replace with new AAA batteries when the low battery symbol appears on the display. Remove the battery cover and replace batteries. Replace the cover.
12. Warranty
Your VICKS®Ear Thermometer is durable and manufactured for a lifetime of normal household use. Following directions carefully will ensure years of dependable operation. If for any reason (other than misuse or normal battery replacement) you are dissatisfied with your VICKS Ear Thermometer, we will repair or replace it, at our option, free for one year from the date of purchase. This Warranty gives you specific legal rights as well as other rights which may vary from state to state.
If the thermometer does not function properly, first check the battery. Replace if necessary. If repair is necessary call our Consumer Service Department at 1-800-477-0457, email us at consumerservice@kaz.com, or write to KAZ Thermometer Service Department, P.O. Box 544, Hudson, NY 12534, explaining just how the thermometer is improperly working. Our consumer service representative will provide further instruction on how to correct the trouble yourself or will ask you to return the thermometer for repair or replacement.
never immerse the instrument in
Low battery symbol
VICKS®
Ear Thermometer
Questions? Call Kaz toll free at 1-800-477-0457 or E-mail: consumerservice@kaz.com www.kaz.com
k
Kaz, Incorporated • Thermometer Service Dept. • P.O. Box 544 • Hudson, NY 12534 • www.kaz.com Distributed by Kaz, Inc. under license from The Procter & Gamble Company, Cincinnati, Ohio USA. VICKS is a registered trademark of The Procter & Gamble Company.
© 2003 KAZ, Incorporated Made and printed in China
Manufacturing Quality Healthcare Products for Over 75 Years
QUICK START GUIDE
®
VICKS
FIRST TIME USE:
• “Pull” plastic strip from Battery Compartment. Discard.
• Remove 98.6F label from the LCD display. Discard.
1
2
3
Ear Thermometer Model V971N
Remove and Save Protective Cap.
ON/OFF
Gently Pull Outer Ear to Straighten Ear Canal.
for
Pull Probe Cover Into Position on Dispenser.
Insert Thermometer Tip Straight and Push Firmly until “Click.”
Turn Unit “ON”. Display Indicates Ready
to Measure.
Some Helpful Guidelines For Best Results When Using the Vicks OneSecond Ear Thermometer,
Practice until you receive consistent readings.
Unit is calibrated with a Sensor Cover.
Accuracy can only be assured when Sensor Covers are used.
Call your doctor when your child has diarrhea, vomiting or changes in appetite, lethargy (sluggishness) or is unusually sleepy.
It is important to know each individuals Normal temperature when they are well.
< 1 Year
> 1 Year
4
5
ON/OFF
Call Kaz at 1-800-477-0457 e-mail: consumerservice@kaz.com • www.kaz.com
Push Start Button.
Turn Please Note: Unit Reads Oral Equivalent Unit Temperature. Add One Degree for Rectal
OFF”. Equivalent. Take 3 or More Measurements
Indicates Complete.
Especially if Readings Appear Low.
Need Assistance?
2
Fully Insert Thermometer Probe
Gently into Ear.
BEEP
98.6 °F
This is the only way to accurately diagnose a fever. Take multiple readings when healthy to determine Normal temperature.
A childs normal temperature can be as high as 99.9°F. Re-measure with a standard digital thermometer for confirmation.
3
VICKS®Ear Thermometer
Instruction Manual
Thank you for purchasing the VICKS Ear Thermometer (V971N).
The VICKS Ear Thermometer incorporates the latest technology and is tested in accordance with international standards. With its unique technology, the thermometer provides a stable, heat­interference-free reading with each measurement. The instrument performs a self-test every time it is switched on to always guarantee the specified accuracy of measurements.
The VICKS Ear Thermometer is intended for intermittent measurements and monitoring of human body temperature in the home. It is appropriate for use on people of all ages.
Please read these instructions carefully before using this instrument and keep the instructions and the thermometer in a safe place.
Gentle and Easy to Use
Soft tip sensor for comfort.
Special ergonomic design of the unit makes its use simple and easy.
The VICKS Ear Thermometer can be used without interference to daily lifestyle. A
measurement can be taken even while a child is sleeping.
The VICKS Ear Thermometer is more pleasant to use and less theratening to children than a
rectal thermometer and is more pleasant to use than an oral thermometer.
Auto-Display Memory
The thermometer displays the last reading automatically for 3 seconds when the unit is switched ON.
Safe and Hygienic
No risk of broken glass or mercury ingestion.
Safe for children.
Disposable sensor covers help prevent the spread of germs.
Table of Contents
1. The Advantages of your VICKS Ear Thermometer
2. Important Safety Instructions
3. Product Description
4. How the VICKS Ear Thermometer Measures Ear Temperture
5. How to Read the Display
6. How to Apply a New Sensor Cover
7. Directions for Use
8. Error Messages
9. Technical Specifications
10. Cleaning and Storage
11. Replacing the Battery
12. Warranty
1. The Advantages of your VICKS®Ear Thermometer
Measurement in 1 second
This innovative infrared technology enables users to measure body temperature in only 1 second.
Accurate and reliable
Due to the unique patented sensor assembly configuration, the advanced infrared sensor, and the complete calibration process, this unit offers a very accurate and reliable way of measuring body temperature.
4
2. Important Safety Instructions
Never use the thermometer for purposes other than body temperature measurement. Please
follow the safety precautions when using on children.
Always use the thermometer with a new undamaged Probe Cover for each measurement to
prevent infection. VICKS branded probe covers can ensure that you get an accurate measurement from the Ear Thermometer.
Never immerse the VICKS Ear Thermometer into water or other liquids (not
waterproof). For cleaning and disinfecting please follow the instructions in the "Cleaning and Storage (Section 10).
Keep the instrument and the probe covers away from direct exposure to the sun and store
in a dust-free, dry area at a temperature between 41°F - 104°F.
Do not use the thermometer if there are signs of damage on the measuring tip or on the
instrument itself. If damaged, do not attempt to repair the instrument!
Earwax in subjects ear canal may cause a lower temperature reading. Before taking
measurement make sure the ear canal is clean to ensure an accurate reading.
The VICKS Ear Thermometer consists of high quality precision parts. Do not drop it! Protect
it from severe impact and shock. Replace protective cap when not in use.
WARNING:
Please keep the sensor covers out of the reach of children.
Use of this thermometer is not intended as a substitute for consultation with your
physician.
This thermometer is not waterproof! NEVER immerse into liquids!
Cleaning the ear canal using improper techniques can harm the inner ear. Follow
doctors instructions for proper cleaning.
Readings taken without probe covers will not be accurate. Only
5
3. Product Description
(1) Sensor Cover
(2)
(2) Soft Sensor Tip
(3) Readout Display
(4) Start Button
(5) ON/OFF Button
(6) Battery Cover
(7) Senser Cover
(8)
(3)
(4)
(5)
(7)
(6)
Applicator
(8) Protective
Storage Cap
4. How the VICKS®Ear Thermometer Measures Ear Temperature
The VICKS Ear Thermometer measures infrared energy radiated from the eardrum and the surrounding tissue. This energy is collected through the sensing lens and converted to a temperature value. The measured reading obtained directly from the eardrum (Tympanic Membrane) can ensure the most accurate ear temperature. Measurements taken from the surrounding tissue of the ear canal generate lower readings and may result in misdiagnosis of a fever.
To avoid an inaccurate measurement:
Use VICKS sensor covers. The unit is calibrated to work with sensor covers.
Straighten the ear canal by gently pulling the middle of the ear back and up. Pull the ear
straightback for newborns to age 1.
Place the sensor firmly into the ear canal. Press the Start button and keep the sensor in the ear until the thermometer beeps to indicate completion of the measurement.
The VICKS Ear Thermometer has been clinically tested to meet ASTM standard E-1065 as pertains to infrared thermometers. It is proven to be safe and accurate when used in accordance with this operating instruction manual.
6
5. How to Read the Display
Display Display Meaning
Self-check ensures proper functioning.
Recall of last reading.
Ready to measure.
Measurement complete.
Low battery indication. Unit will not take accurate measurements.
Description
Press the ON/OFF button to turn on the unit. All icons will be shown for 2 seconds.
The last reading will be shown on the display automatically for 3 seconds.
The unit beeps once and the °F icon will keep flashing.
The reading will be shown on the LCD display. When the °F starts to flash the unit is ready for next temperature.
The battery icon will flash when the unit is on to alert you to replace the batteries.
6. How to Apply a New Sensor Cover
(1) Remove protective cap from thermometer.
Pull sensor cover into position over the hole in the top of dispenser.
Completely push the tip into the
(3)
sensor cover holder hole. Push firmly.
NOTE:
Unit is calibrated to work with sensor covers. Only use of VICKS sensor covers ensures accuracy and hygienic use.
In order to avoid spreading germs, please use a new sensor cover for each measurement.
Check to ensure sensor cover is fitted on firmly before use. If the sensor cover is broken,
discard and apply a new one immediately.
Failure to use sensor covers each time will result in low, misreadings.
(2) With Protective Cap off, push the thermometer
vertically into the center part of the sensor cover.
(4) After feeling a slight click, take out the sensor
with cover attached tightly.
7
7. Directions for Use
BEFORE FIRST USE:
Remove insulating plastic strip from Battery Cover.
Important: Prior to each measurement, fit a new undamaged sensor cover onto sensor. Failure to do so may result in an incorrect temperature measurement.
1. Press the ON/OFF button. The display is activated to show all symbols for 2 seconds.
2. The last measurement reading with an “M” icon will be shown on the display automatically for 3 seconds.
3. When a beep sound is heard and the °F symbol starts flashing, the thermometer is ready to measure.
4. Straighten the ear canal by pulling the ear up and back to give a clear view of the eardrum.
For children under 1 year:
- Pull the ear straight back
Children ages 1 year to adult:
- Pull the ear up and back. (Caution: Many pediatricians suggest use of ear thermometers for children older than 6 months.)
5. While pulling the ear, insert the sensor snugly into the ear
canal and press and release the "START button. When you hear a beep sound, this indicates measurement is complete.
6. Remove the thermometer from the ear canal. The display
shows the measured temperature.
7. Replace the sensor cover after each measurement. To do this, please follow the instructions
in Section 6 How to Apply a New Probe Cover.
8. In order to assure accurate readings, please wait at least 30 seconds after 3-5 continuous
measurements.
1 year-adult Newborn-1 year
ON/OFF
98.6
F
°
M
Readings Recall Sequence
- - -
12
5. To clear memory: a) Press and hold START Button. b) While holding START Button, press and release ON/OFF Button. After a few seconds the unit will turn on and display the last reading. When the last reading comes up, release the START Button before the reading disappears. The “M” will disappear from the Display indicating memory is cleared. When “°F starts flashing, the thermometer is ready to take a temperature.
Pressing and releasing the START button after the last 12 readings have all been recalled will resume the above sequence from reading 1.
NOTE:
For an infant, it is best to have the child lie on its back with head turning sideways and one of the ears is facing upwards. For an older child or adult, it is best to stand behind and slightly to the side of the patient.
Always take measurements in the same ear as the temperature in the right ear may be different from that in the left ear.
Please wait for a few minutes to take the ear temperature after sleeping.
In the following situations, it is recommended that three temperatures in the same ear be
taken and the highest one taken as the reading:
1) Newborn infants in the first 100 days.
2) Children under three years of age with a compromised immune system and for whom
3) When the user is learning how to use the ear thermometer for the first time until he/she
1. Press the START Button to enter Recall Mode when the power is off. The memory icon "M" will flash.
M
2. Press and release the START Button to recall the latest
°
F
M
1
2
98.2
M
101.5
M
101.8
the presence or absence of fever is critical.
has familiarized himself/herself with the instrument and obtains consistent readings.
reading. The LCD will display 1 alone with the memory
M
icon when the button is pressed and the most recent reading when the button is released.
°
F
3. Press and release the START Button again to recall the
M
second latest reading.
°
F
4. Press and release the START Button consecutively to recall
M
readings in succession, up to the last 12 readings.
Caution: If you are not confident of the readings obtained, confirm temperature with a standard VICKS digital thermometer.
8
9
8. Error Messages
Display Meaning
Measured temperature too high
Measured temperature too low
* Caution: High fever requires immediate medical attention!
Display / Problem Display Meaning
Room temperature too high
Room temperature too low
Error function display
Blank display
Dead battery indication
Possible cause and remedy
Displays “H“ when measured temperature is higher than
108.0 °F. Repeat taking temperature and confirm with digital thermometer.
Displays “L“ when measured temperature is lower than 89.6 °F. See Section 7 for proper technique.
Possible cause and fault remedy
Displays “H“ in conjunction with the s when room temperature is higher than
104.0 °F.
Display “L“ in conjunction with the t“ when room temperature is lower than
41.0 °F.
Check battery. Possible damage from dropping or water.
Please check if battery is loaded correctly.
If the steady battery icon is the only symbol shown, the battery should be replaced immediately.
9. Technical Specifications
Type:
Measuring Range:
Accuracy:
Display:
Beeps When:
Memory:
Illuminated Display: (Back-Lite)
Operating temperature:
Storage/transport temperature:
Automatic Switch-off:
Battery:
Dimensions:
Weight:
Standards:
Please observe the applicable disposal regulations.
Digital Infrared Thermometer IR 1DA1
32.0 - 42.2 °C or 89.6 - 108.0 °F
Laboratory: : ±0.2 °C, 32.0 ~ 42.2 °C ±0.4 °F, 89.6 ~ 108.0 °F
Liquid Crystal Display with 0.1 °C (0.1 °F) resolution.
a. The unit is turned ON and ready for the measurement:
b. Measurement complete: 1 long beep sound. c. System error, malfunction, or Hi””Low measurement.
d. Fever alert: If measurement >99.5F, multiple beeps sound
Automatically displays the last measured temperature.
a. The display will be lighted for 4 seconds when the unit
b. The display will be lighted again for 5 seconds when
-20°C to +50°C (-4°F to +122°F)
-25 °C to +55 °C (-13 °F to 131 °F)
Approx. 1 minute after last measurement has been taken.
2 AAA bateries
122mm (L) x 44 mm (W) x 63 mm (H)
92g (with batteries), 70g (w/o batteries)
Complies with European PrEN12470-5 and U.S. ASTM E-1965 requirements
1 short “beep“ sounds.
3 short “beep“ sounds.
(instead of a single beep).
is turned ON.
the measurement has been completed.
10
11
Loading...