IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE SAFETY INSTRUCTIONS
BEFORE USING THIS HUMIDIFIER
When using electrical appliances, basic
precautions should always be followed
to reduce the risk of fire, electric
shock, and injury to persons, including
the following:
1.Always place this humidifier on a
firm, flat and level surface. This
humidifier may not work properly on
an uneven surface.
2.Place this humidifier in an area where
it is not accessible to children.
3.Do not place the humidifier near any
heat sources such as stoves, radiators, and heaters.
4.Do not use the humidifier outdoors.
5.Before using the humidifier, check the
power cord for any signs of damage.
If the cord is found to be damaged,
DO NOT USE and return the humidifier to the manufacturer under the
warranty agreement for repair.
6.This appliance has a polarized plug
(one blade is wider than the other). To
reduce the risk of shock, this plug is
intended to fit only one way in a
polarized outlet. If the plug does not
fit securely in the outlet, reverse the
plug. If it still does not fit, contact a
qualified electrician. DO NOT attempt
to defeat this safety feature.
7.To disconnect the humidifier, first turn
controls to the OFF position, then grip
the plug and pull it from the wall outlet. Never pull by the cord.
8.A loose fit between the AC outlet
(receptacle) and plug may cause
overheating and a distortion of the
plug. Contact a qualified electrician to
replace loose or worn outlet.
9.The humidifier should always be
unplugged and emptied when not in
operation or while being serviced or
cleaned.
10. Never tilt or attempt to move the
humidifier while it is operating or
filled with water. UNPLUG the humidifier before moving.
11. This humidifier requires regular
cleaning. Refer to the CLEANING
instructions provided. Never clean the
humidifier in any manner other than
as instructed in this manual.
12. Do not direct moisture flow directly at
individuals, walls or furniture.
13. When a humidifier is used in a closed
room or small rooms, check periodically for proper ventilation, as excessive humidity can cause condensation
stains on walls.
14. Turn the humidifier OFF if you notice
moisture on the inside of your windows. For proper humidity reading
use a hygrometer, which is available
in many hardware and department
stores, or by ordering one from the
manufacturer.
The sealed UV bulbs contain a
small amount of mercury. Dispose
of these items at household hazardous waste collection sites only.
If the UV bulb breaks, do not vacuum or handle with your bare
hands.
VICKS®COOL MIST HUMIDIFIER (V3800 Series)
Water Tank
Seal Pad
Tank Cap
Filter
Tray
Main Housing
SETTING UP YOUR HUMIDIFIER
Placement
Soak Filter
Fill Tank
Step 1
Select a firm, level location at least 6” (15cm) from any
walls for proper airflow. Place the humidifier on a waterresistant surface, as water can damage furniture and
some flooring.
Kaz will not accept responsibility for property damage
caused by water spillage.
Step 1
Remove tank.
Remove the filter from
the holding basket.
Soak the filter in cool water.
Step 3Step 2
Place wet filter back in
the filter holding basket
and place back in unit.
DO NOT squeeze filter.
Step 1Step 2Step 3
Power
Turn tank upside-down.
Remove tank cap by turn-
ing counterclockwise
Power Step 1
.
Fill tank with cool
tap water.
Replace tank cap. Tighten
by turning clockwise .
Place tank back on
Once the filled water tank
has been placed on the
unit do not move humidifier. Doing so could
cause leakage and spills.
humidifier.
With the power switch in the OFF position, plug the filled
humidifier into a polarized 120V outlet. DO NOT FORCE
THE POLARIZED PLUG INTO THE OUTLET; it will only fit
one way.
DO NOT plug in humidifier with wet hands to avoid
electric shock.
OPERATING YOUR HUMIDIFIER
Model # Output/Fan Speed Control Set Humidity
V3800
V3850
Step 1
Set fan speed to desired
output:
High ()
Fast Humidifiying
Medium ()
Everyday moisture control
Low ()
Step 1Step 2
Turn the humidistat knob
clockwise to the
highest setting ().
Run on high for at least
1 hour or until room has
reached a comfortable
humidity level.
Nighttime or
maintenance use
Step 1Step 1
Press power to start unit
in high speed.
Max: 55% Min: 35%
Use the (+) up or (–) down
button to set desired
humidity.
Then slowly turn the humidistat knob counter-clockwise
until the humidifier
shuts off. The desired humidity light will illuminate.
Once set, the humidifier will
automatically cycle on and off
based on your setting.
Step 2
Push (+) Up button or (–)
Down button to select the
output level.
The unit will operate until the selected humidity is reached
or the unit is turned off. When desired humidity is reached,
the fan will shut off but LED will remain lit. The fan will turn
back on when the room humidity drops below the set
level.
NOTE: To go back to continuous run mode, turn your
unit off and on again.
NOTE: The UV bulb can be turned off and on using the
button.
NOTE: It is recommended that all maintenance be done in the kitchen or bathroom on a water resistant surface. Remove water tank from unit before moving.
CHANGING YOUR FILTER
The filter should be changed every 1-3 months depending on your water quality. Keep in mind, depending
on your water quality, mineral deposits can still clog or discolor the filter, affecting its life and that of the
humidifier.
It is recommended you change your filter in the bathroom or kitchen. Keep in mind your filter may be
damp depending on your last usage.
To change the filter:
Step 1Step 2Step 3
Uses replacement filter
WF2.
Turn off and unplug
your humidifier.
Remove the water tank.Remove filter holding
Step 4
basket and discard old
filter.
Step 5Step 6Step 7
Soak new filter in cool
water.
Do not squeeze out.
Insert new filter into
holding basket and
place filter holding basket back in unit.
Replace the water tank.
CHANGING THE UV BULB
The UV bulb will operate for an average output of 10,000 hours. To replace UV bulb contact 1-800-477-0457
or consumerrelations@kaz.com.
Step 1Step 2Step 3
Turn off and unplug
your humidifier.
Remove the water tank
and carefully set aside.
Press on the button located on the side of the UV
bulb. Carefully use your other hand to pull the UV
cartridge away from the unit.
CHANGING THE UV BULB (CONT’D.)
Step 4Step 5
Place your replacement UV bulb in the unit by
pressing the UV bulb firmly into the opening. Be
Step 6
Place filter basket and replace the water tank in
the humidifier.
certain the prongs locate on the back of the bulb
are lined up with the receptacle in the UV holder.
NOTE: Discard the old UV bulb cartridge at a household hazardous waste collection site. Bulb and
bulb housing are not intended for use with any other product or purpose.
Lamp contains mercury. Manage in accordance with disposal laws.
See www.lamprecycle.org or call 1-800-895-8842.
CLEANING
Cleaning involves two steps, SCALE REMOVAL and DISINFECTING. Be sure to perform these in the
proper order to avoid harmful chemical interactions.
NOTE: REMOVE FILTER BEFORE CLEANING.
Failure to remove filter during cleaning will destroy the filter.
SCALE REMOVAL
Step 1Step 2Step 3Step 4
Turn off and unplug
your humidifier.
Place basket in sink or
tub and fill the bottom
of the basket with undiluted vinegar.
Remove water tank.Remove filter basket.Remove filter from bas-
ket. Failure to do so will
destroy the filter.
Step 8
Rinse the filter basket
thoroughly with water
to remove scale using
Let stand for 20 minutes.
Step 7Step 6Step 5
With vinegar in the bas-
ket, wipe surface with a
soft cloth or brush.
cleaning solution.
CLEANING (CONT’D.)
DISINFECTING
Step 1
Step 2Step 3
Remove water tank.Remove filter holding
basket.
Remove filter and set
aside. Failure to do so
will destroy the filter.
Step 4
1
l
g
a
Fill water tank with 1
tsp. of household
bleach and 1 gallon of
cool water
Step 5
Step 6Step 7
NOTES: The use of
other water treatment
products and chemicals may cause deterioration of the filter
or damage the humidifier, thereby hinder-
Pour some solution into
the filter basket.
Let stand for 20 minutes.
Rinse with water until
the smell of bleach is
ing the humidifier’s
effectiveness.
gone.
END-OF-SEASON CARE AND STORAGE
• Follow the CLEANING instructions when the humidifier will not be used for at least one week or more,
or at the end of the season.
• At the end of the season, remove and throw away the filter; do not store with a used filter.
• Dry the humidifier completely before storing. DO NOT store with water inside the Base or Water Tank.
• Pack the unit in its original carton and store in a cool, dry location.
• Before next use, remember to clean your humidifier and install a new filter.
CONSUMER RELATIONS
Mail questions or comments to: Kaz, Incorporated
Consumer Relations Dept.
250 Turnpike Road, Southborough, MA 01772
Please be sure to specify model number.
Call us toll-free at: 1-800-477-0457; E-mail: consumerrelations@kaz.com
Or visit our website at: www.kaz.com
Purchase replacement filter part number WF2 and UV bulb part number XXXXX.
ELECTRICAL RATINGS
The Vicks®models are rated at 120V, 60 Hz.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE RETURN THE HUMIDIFIER TO THE ORIGINAL PLACE
OF PURCHASE OR SEE YOUR WARRANTY. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER OR PERSONAL INJURY.
TROUBLESHOOTING
Q: I hear the fan turning, but I don’t see any mist. Is my humidifier operating properly?
A: Dry air is pulled through the system and a fan disperses invisible, moisture balanced air.There is no
“mist” emitted. When operating normally you will feel only cool air coming from the unit. Monitor the
water level in your Tank/ Base. If you notice a decrease in the Water Tank over 24 hours then the unit
is operating normally.
Q: My unit has been running for several hours. I hear the fan spinning, but I do not notice the
water level in the tank decreasing.
A: First, check the filter to ensure it is wet. If the pad appears dry, remove it from the Base and gently
rinse under cool water. Reposition wet filter in the Base. You may also want to note the current moisture level in your home. If the humidity level is over 60% the unit will not put out much moisture as
your air is already saturated.
Q: The humidifier is not running (the fan is not even spinning), but all (or some) of the lights are
on. (Model V3800)
A: If the Desired Humidity light is ON: The Advanced Mist
™
Humidistat knob may be set too low. Moving
the knob clockwise to the end should restart the unit.
Q: The Advanced Mist
™
Humidistat knob was set according to the manual, but the humidifier
never seems to turn back on. Is something wrong? (Model V3800)
A: The Humidistat knob may be set too low. Moving the Humidistat knob to the end clockwise
should restart the unit.
Q: The Advanced Mist
™
Humidistat knob was set according to the manual, but the humidifier
never seems to turn off. Is something wrong? (Model V3800)
A:The Humidistat knob may be set too high. Reset the Advanced Mist
™
Humidistat knob following the
instructions under FEATURES.
Q: My filter has turned light brown and rust colored. Do I need a new filter?
A:Probably not. Since your filter has been made with Protec
™
antimicrobial the change in color indicates only a mineral deposit. Soak filter in a sink full of cool water to help break up deposits. The
discoloration may remain but will not affect the humidifier’s performance.
Q: My humidifier doesn’t appear to be as clean as when I first purchased and/or I’m smelling an
unpleasant odor. What should I do?
A: If you have been using your humidifier regularly for over 30 days, follow the cleaning instructions.
3 YEAR LIMITED WARRANTY
You should first read all instructions before
attempting to use this product.
A.This 3 year limited warranty applies to repair
or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from
commercial, abusive, unreasonable use or
supplemental damage. It also does not apply
to the filter or Protec
™
Cleaning Cartridge.
Defects that are the result of normal wear
and tear will not be considered manufacturing
defects under this warranty.
KAZ IS NOT LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES OF ANY
NATURE. ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE ON THIS PRODUCT
IS LIMITED IN DURATION TO THE DURATION
OF THIS WARRANTY.
Some jurisdictions do not allow the exclusion
or limitation of incidental or consequential
damages or limitations on how long an
implied warranty lasts, so the above limitations or exclusions may not apply to you. This
warranty gives you specific legal rights, and
you also may have other rights which vary
from jurisdiction to jurisdiction. This warranty
applies only to the original purchaser of this
product from the original date of purchase.
B.At its option, Kaz will repair or replace this
product if it is found to be defective in material or workmanship. Defective product should
be returned to the place of purchase in accordance with store policy. Thereafter, while
within the warranty period defective product
may be returned to Kaz.
C.This warranty does not cover damage result-
ing from any unauthorized attempts to repair
or from any use not in accordance with the
instruction manual.
D.Return defective product to Kaz, Incorporated
with a brief description of the problem.
Include proof of purchase and a $10
US/$15.50 CAN check or money order for
handling, return packing and shipping
charges. Please include your name, address
and a daytime phone number. You must pre-pay shipping charges. Send to
:
In U.S.A.:
Kaz, Incorporated
Attn: Returns Department
4755 Southpoint Drive
Memphis, TN 38118
USA
In Canada:
Kaz, Incorporated
Attn: Returns Department
510 Bronte Street South
Milton, ON L9T 2X6
Canada
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.