Kaz V3850, V3800, V3850juv Owner's Manual

Vicks®Cool Moisture Humidifier
Use and Care Manual
IMPORTANT!
READ AND SAVE THESE INSTRUCTIONS
V3800 Series
If you have any questions about the operation of your Vicks Cool Mist Humidifier, call our toll-free Consumer Relations line at 800 VAPOR-12 or e-mail us at Consumerrelations@kaz.com.
k
Manufacturing Quality Healthcare Products for Over 75 Years
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE SAFETY INSTRUCTIONS
BEFORE USING THIS HUMIDIFIER
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
1. Always place this humidifier on a
firm, flat and level surface. This humidifier may not work properly on an uneven surface.
2. Place this humidifier in an area where
it is not accessible to children.
3. Do not place the humidifier near any
heat sources such as stoves, radia­tors, and heaters.
4. Do not use the humidifier outdoors.
5. Before using the humidifier, check the
power cord for any signs of damage. If the cord is found to be damaged, DO NOT USE and return the humidifi­er to the manufacturer under the warranty agreement for repair.
6. This appliance has a polarized plug
(one blade is wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit securely in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
7. To disconnect the humidifier, first turn
controls to the OFF position, then grip the plug and pull it from the wall out­let. Never pull by the cord.
8. A loose fit between the AC outlet
(receptacle) and plug may cause overheating and a distortion of the
plug. Contact a qualified electrician to replace loose or worn outlet.
9. The humidifier should always be
unplugged and emptied when not in operation or while being serviced or cleaned.
10. Never tilt or attempt to move the
humidifier while it is operating or filled with water. UNPLUG the humidi­fier before moving.
11. This humidifier requires regular
cleaning. Refer to the CLEANING instructions provided. Never clean the humidifier in any manner other than as instructed in this manual.
12. Do not direct moisture flow directly at
individuals, walls or furniture.
13. When a humidifier is used in a closed
room or small rooms, check periodi­cally for proper ventilation, as exces­sive humidity can cause condensation stains on walls.
14. Turn the humidifier OFF if you notice
moisture on the inside of your win­dows. For proper humidity reading use a hygrometer, which is available in many hardware and department stores, or by ordering one from the manufacturer.
The sealed UV bulbs contain a small amount of mercury. Dispose of these items at household haz­ardous waste collection sites only. If the UV bulb breaks, do not vacu­um or handle with your bare hands.
VICKS®COOL MIST HUMIDIFIER (V3800 Series)
Water Tank
Seal Pad
Tank Cap
Filter
Tray
Main Housing
SETTING UP YOUR HUMIDIFIER
Placement
Soak Filter
Fill Tank
Step 1
Select a firm, level location at least 6” (15cm) from any walls for proper airflow. Place the humidifier on a water­resistant surface, as water can damage furniture and some flooring.
Kaz will not accept responsibility for property damage caused by water spillage.
Step 1
Remove tank.
Remove the filter from the holding basket.
Soak the filter in cool water.
Step 3Step 2
Place wet filter back in the filter holding basket and place back in unit.
DO NOT squeeze filter.
Step 1 Step 2 Step 3
Power
Turn tank upside-down. Remove tank cap by turn-
ing counter­clockwise
Power Step 1
.
Fill tank with cool tap water.
Replace tank cap. Tighten by turning clockwise .
Place tank back on
Once the filled water tank has been placed on the unit do not move humidi­fier. Doing so could cause leakage and spills.
humidifier.
With the power switch in the OFF position, plug the filled humidifier into a polarized 120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET; it will only fit one way.
DO NOT plug in humidifier with wet hands to avoid electric shock.
OPERATING YOUR HUMIDIFIER
Model # Output/Fan Speed Control Set Humidity
V3800
V3850
Step 1
Set fan speed to desired output:
High () Fast Humidifiying
Medium () Everyday moisture control
Low ()
Step 1 Step 2
Turn the humidistat knob clockwise to the highest setting ( ).
Run on high for at least 1 hour or until room has reached a comfortable humidity level.
Nighttime or maintenance use
Step 1 Step 1
Press power to start unit in high speed.
Max: 55% Min: 35% Use the (+) up or (–) down
button to set desired humidity.
Then slowly turn the humidis­tat knob counter-clockwise
until the humidifier shuts off. The desired humidi­ty light will illuminate.
Once set, the humidifier will automatically cycle on and off based on your setting.
Step 2
Push (+) Up button or (–) Down button to select the output level.
The unit will operate until the selected humidity is reached or the unit is turned off. When desired humidity is reached, the fan will shut off but LED will remain lit. The fan will turn back on when the room humidity drops below the set level.
NOTE: To go back to continuous run mode, turn your unit off and on again.
NOTE: The UV bulb can be turned off and on using the
button.
NOTE: It is recommended that all maintenance be done in the kitchen or bathroom on a water resis­tant surface. Remove water tank from unit before moving.
CHANGING YOUR FILTER
The filter should be changed every 1-3 months depending on your water quality. Keep in mind, depending on your water quality, mineral deposits can still clog or discolor the filter, affecting its life and that of the humidifier.
It is recommended you change your filter in the bathroom or kitchen. Keep in mind your filter may be damp depending on your last usage.
To change the filter:
Step 1 Step 2 Step 3
Uses replacement filter WF2.
Turn off and unplug your humidifier.
Remove the water tank. Remove filter holding
Step 4
basket and discard old filter.
Step 5 Step 6 Step 7
Soak new filter in cool water.
Do not squeeze out.
Insert new filter into holding basket and place filter holding bas­ket back in unit.
Replace the water tank.
CHANGING THE UV BULB
The UV bulb will operate for an average output of 10,000 hours. To replace UV bulb contact 1-800-477-0457 or consumerrelations@kaz.com.
Step 1 Step 2 Step 3
Turn off and unplug your humidifier.
Remove the water tank and carefully set aside.
Press on the button located on the side of the UV bulb. Carefully use your other hand to pull the UV cartridge away from the unit.
CHANGING THE UV BULB (CONTD.)
Step 4 Step 5
Place your replacement UV bulb in the unit by pressing the UV bulb firmly into the opening. Be
Step 6
Place filter basket and replace the water tank in
the humidifier. certain the prongs locate on the back of the bulb are lined up with the receptacle in the UV holder.
NOTE: Discard the old UV bulb cartridge at a household hazardous waste collection site. Bulb and bulb housing are not intended for use with any other product or purpose.
Lamp contains mercury. Manage in accordance with disposal laws. See www.lamprecycle.org or call 1-800-895-8842.
CLEANING
Cleaning involves two steps, SCALE REMOVAL and DISINFECTING. Be sure to perform these in the proper order to avoid harmful chemical interactions.
NOTE: REMOVE FILTER BEFORE CLEANING.
Failure to remove filter during cleaning will destroy the filter.
SCALE REMOVAL
Step 1 Step 2 Step 3 Step 4
Turn off and unplug your humidifier.
Place basket in sink or tub and fill the bottom of the basket with undi­luted vinegar.
Remove water tank. Remove filter basket. Remove filter from bas-
ket. Failure to do so will destroy the filter.
Step 8
Rinse the filter basket thoroughly with water to remove scale using
Let stand for 20 min­utes.
Step 7Step 6Step 5
With vinegar in the bas-
ket, wipe surface with a
soft cloth or brush.
cleaning solution.
CLEANING (CONTD.)
DISINFECTING
Step 1
Step 2 Step 3
Remove water tank. Remove filter holding
basket.
Remove filter and set
aside. Failure to do so
will destroy the filter.
Step 4
1
l
g
a
Fill water tank with 1 tsp. of household bleach and 1 gallon of cool water
Step 5
Step 6 Step 7
NOTES: The use of other water treatment products and chemi­cals may cause dete­rioration of the filter or damage the humid­ifier, thereby hinder-
Pour some solution into the filter basket.
Let stand for 20 min­utes.
Rinse with water until
the smell of bleach is
ing the humidifier’s effectiveness.
gone.
END-OF-SEASON CARE AND STORAGE
• Follow the CLEANING instructions when the humidifier will not be used for at least one week or more,
or at the end of the season.
• At the end of the season, remove and throw away the filter; do not store with a used filter.
• Dry the humidifier completely before storing. DO NOT store with water inside the Base or Water Tank.
• Pack the unit in its original carton and store in a cool, dry location.
• Before next use, remember to clean your humidifier and install a new filter.
CONSUMER RELATIONS
Mail questions or comments to: Kaz, Incorporated
Consumer Relations Dept. 250 Turnpike Road, Southborough, MA 01772
Please be sure to specify model number.
Call us toll-free at: 1-800-477-0457; E-mail: consumerrelations@kaz.com Or visit our website at: www.kaz.com
Purchase replacement filter part number WF2 and UV bulb part number XXXXX.
ELECTRICAL RATINGS
The Vicks®models are rated at 120V, 60 Hz.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE RETURN THE HUMIDIFIER TO THE ORIGINAL PLACE OF PURCHASE OR SEE YOUR WARRANTY. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOUR­SELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER OR PERSON­AL INJURY.
TROUBLESHOOTING
Q: I hear the fan turning, but I don’t see any mist. Is my humidifier operating properly? A: Dry air is pulled through the system and a fan disperses invisible, moisture balanced air.There is no
“mist” emitted. When operating normally you will feel only cool air coming from the unit. Monitor the water level in your Tank/ Base. If you notice a decrease in the Water Tank over 24 hours then the unit is operating normally.
Q: My unit has been running for several hours. I hear the fan spinning, but I do not notice the
water level in the tank decreasing.
A: First, check the filter to ensure it is wet. If the pad appears dry, remove it from the Base and gently
rinse under cool water. Reposition wet filter in the Base. You may also want to note the current mois­ture level in your home. If the humidity level is over 60% the unit will not put out much moisture as your air is already saturated.
Q: The humidifier is not running (the fan is not even spinning), but all (or some) of the lights are
on. (Model V3800)
A: If the Desired Humidity light is ON: The Advanced Mist
Humidistat knob may be set too low. Moving
the knob clockwise to the end should restart the unit.
Q: The Advanced Mist
Humidistat knob was set according to the manual, but the humidifier
never seems to turn back on. Is something wrong? (Model V3800)
A: The Humidistat knob may be set too low. Moving the Humidistat knob to the end clockwise
should restart the unit.
Q: The Advanced Mist
Humidistat knob was set according to the manual, but the humidifier
never seems to turn off. Is something wrong? (Model V3800)
A: The Humidistat knob may be set too high. Reset the Advanced Mist
Humidistat knob following the
instructions under FEATURES.
Q: My filter has turned light brown and rust colored. Do I need a new filter? A: Probably not. Since your filter has been made with Protec
antimicrobial the change in color indi­cates only a mineral deposit. Soak filter in a sink full of cool water to help break up deposits. The discoloration may remain but will not affect the humidifier’s performance.
Q: My humidifier doesn’t appear to be as clean as when I first purchased and/or I’m smelling an
unpleasant odor. What should I do?
A: If you have been using your humidifier regularly for over 30 days, follow the cleaning instructions.
3 YEAR LIMITED WARRANTY
You should first read all instructions before attempting to use this product.
A. This 3 year limited warranty applies to repair
or replacement of product found to be defec­tive in material or workmanship. This warran­ty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. It also does not apply to the filter or Protec
Cleaning Cartridge. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty.
KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limita­tions or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.
B. At its option, Kaz will repair or replace this
product if it is found to be defective in materi­al or workmanship. Defective product should be returned to the place of purchase in accor­dance with store policy. Thereafter, while within the warranty period defective product may be returned to Kaz.
C. This warranty does not cover damage result-
ing from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.
D. Return defective product to Kaz, Incorporated
with a brief description of the problem. Include proof of purchase and a $10 US/$15.50 CAN check or money order for handling, return packing and shipping charges. Please include your name, address and a daytime phone number. You must pre- pay shipping charges. Send to
:
In U.S.A.:
Kaz, Incorporated Attn: Returns Department 4755 Southpoint Drive Memphis, TN 38118 USA
In Canada:
Kaz, Incorporated Attn: Returns Department 510 Bronte Street South Milton, ON L9T 2X6 Canada