Kaz HWM705 series User Manual

WARM MIST
HUMIDIFIER
MODEL HWM705 Series
IMPORTANT
SAFETY INSTRUCTIONS
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HUMIDIFIER
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to people or property, including the following:
1. The appliance should always be placed on a
firm, flat, waterproof surface at least four feet (1.22m) away from bedside, twelve inches (30cm) from the wall and out of reach of patients, children and pets. Be sure the appliance is in a stable position and the power cord is away from heated surfaces and out of the way to prevent the humidifier from being tripped over.
2. The appliance should not be left unattended
in a closed room since air could become saturated and leave condensation on walls and furniture. Leave room door partly open.
3. Before using the appliance, extend the cord and inspect for any signs of damage. Do not use the unit if the cord has been damaged.
4. The appliance has a polarized plug (one blade is wider than the other) as a safety feature. This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
5. To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.
6. The appliance should always be unplugged and emptied when not in operation or while being cleaned. Shut off and unplug humidifier before moving. Do not move or tilt humidifier while it is in operation. Plug and unplug unit with dry hands. Never pull by cord.
7. Do not operate the appliance without water.
Turn off and unplug unit when tank is empty and the reset light is on.
8. Caution: To avoid the risk of fire, shock or
personal injury, do not use an extension cord.
9. Appliance requires regular cleaning. Refer to and follow cleaning instructions.
10. Do not operate outdoors; this appliance is
intended for indoor use.
11. Do not cover or insert objects into any
openings on the unit.
12. Do not attempt to repair or adjust any
electrical or mechanical functions on this appliance. Doing so will void your warranty.
13. Do not add any medications (e.g. Kaz Inhalant
or Vicks VapoSteam®) into Mist Outlet, Base, Water Reservoir or Water Tank.
14. Do not touch the steam vapor. Steam can cause burns. Do not operate without the Medicine Cup in place on top of the Mist Outlet.
15. When moving or lifting the Water Tank, use one hand on the Top Tank Handle and the other on the Bottom Tank Handle. The bottom housing and Water Tank are not attached.
16. For Residential Use Only.
HWM705 SERIES ACCESSORIES
1. Remove Water Tank by grasping the Top Tank Handle and pulling up. Remove Tank Cap
located on bottom of Water Tank by turning counter clockwise.
2. Fill Water Tank with cool water. Do not fill with warm or hot water.
3. Replace Tank Cap by turning clockwise to lock back in place. Do not over tighten.
Place Water Tank back on humidifier Base and turn humidifier on.
Step 1 Step 2
Step 3
Power Knob
Power Light
Heating Chamber
Heating Element
Cooling
Chamber
Medicine Cup
Mist Outlet
Steam Outlet
Base
Water Tank
Removable Tray Lift Tab
Cooling Chamber Tab
Water Reservoir
Locking Tab
Bottom Tank Handle
Top Tank Handle
Removable Tray
HWM705 SERIES HUMIDIFIER COMPONENTS
SETTING UP YOUR HUMIDIFIER
How it Works:
The tank feeds water into the Heating Chamber where it is heated to a pure steam vapor. The steam vapor mixes with dry air in the Cooling Chamber and is released in to the room as soothing warm mist.
FILLING/REFILLING
NOTE: The Water Tank should be carried using two hands: one handing holding the Top Tank Handle and the other holding the Bottom Tank Handle.
The following accessories work great with your humidifier.
Kaz Inhalant, KFC-4 in U.S, or Vicks VapoSteam, VS177CANEA in Canada
Can be added to medicine cup area to provide soothing menthol vapors to help provide comfort.
Protec Cleaning Cartridge, PC-1BXN in U.S, or PC-1C in Canada
Keeps your humidifier cleaner, longer. Continuously cleans and protects humidifiers against bacteria and mold for 30 days.
1. Remove humidifier and all contents from box. Save Use and Care Manual for future use. Recycle packaging materials or save for storage.
2. Remove twist tie from power cord and extend power cord full length. Do not operate with power cord coiled or twist tie in place.
3-4. Ensure proper assembly. Make sure Cooling Chamber and and Removable Tray are securely in place and the Locking Tab is engaged.
5. Select a firm, level location at least 12" (30cm) from any walls. Place the humidifier on a water-resistant surface. Steam should be directed away from any walls, bedding or furniture.
Kaz will not accept responsibility for property damage caused by water spillage.
RESET:
When your humidifier is out of water the refill light will illuminate. Turn off and unplug the humidifier, and wait 20-30 mins until unit cools down.
WARNING: KEEP OUT OF REACH OF CHILDREN AND PETS.
This product produces HOT STEAM and should be placed in an area not accessible to children or pets. Ensure the power cord is also securely out of reach.
Step 5
Step 3 Step 2 Step 1
Step 4
Refill Light
Loading...
+ 2 hidden pages