Kaz HY-047, HY-048, HY-041, EFY-047, EFY-041 User Manual

...
Owner’s Manual
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS F AN
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
1. Use this fan only as described in this
manual. Other use not recommended as it may cause fire, electric shock or injury to persons.
2. This product is intended for household use commercial, industrial or outdoor use.
3. To protect against electric shock, do not place fan in window, immerse unit, plug or cord in water or spray with liquids.
4. This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. to defeat this safety feature.
ONLY and not for
NOT
DO
attempt
TOWER FAN
EFY-041 Series, EFY-045 Series EFY-047 Series, HY-041 Series HY-047 Series, HY-048 Series
5. Close supervision is necessary when
any appliance is used by or near children.
6. Turn the fan OFF and unplug the fan from the outlet when not in use, when moving the fan from one location to another and before cleaning.
7. To disconnect the fan, first tur n the unit
OFF, grip the plug and pull it from the wall outlet. Never pull the plug by the cord.
8. Do not operate the fan in the presence of explosive and/or flammable fumes.
9. Do not place the fan or any parts near an open flame, cooking or other heating appliance.
10. Do not operate the fan with a damaged cord or plug or if the product malfunctions, is dropped or damaged in any manner (see warranty).
11. Avoid contact with moving fan parts.
12. The use of attachments not
recommended by the manufacturer may be hazardous.
13. Place the fan on a dry level surface.
14. Do not hang or mount fan on a wall or
ceiling.
15. Do not operate if the fan housing is damaged.
16. A loose fit between the AC outlet (receptacle) and plug may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn outlet.
WARNING: To Reduce The Risk of Fire or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.
ASSEMBLY INSTRUCTIONS
ASSEMBLY INSTRUCTIONS FOR LOW FAN HEIGHT OPTION A. Base Assembly
• Align the two portions of the circular base and snap together by gently pushing the 4 round extrusions (Fig. 1, Item A) into the adjacent circles of the connecting piece. (Fig. 1, Item B)
• Place the power cord through the center of the 2 halves of the base assembly.
B. Securing the Tower Fan to the Base
• Carefully turn the fan on its side.
• Pull any slack out of the power cord. Align the base arrow marked as with the tower fan arrow marked as . Rotate the base clockwise to lock the tower fan in place. (Fig. 2)
• Secure the base assembly to the tower fan by inserting and tightening the thumb screw to the bottom of the base. (Fig. 3)
C. Securing the Cord to the Base
• With the fan on its side, locate the cord holding bracket on the bottom of the base.
• Gently pull any slack out of the power cord, place the power cord securely in the power cord holding bracket and secure the power cord bracket over the power cord. (Fig. 4)
• Return the tower fan to its upright position. Note: Do not operate the tower fan unless it is in its proper,
upright position. Note: Only one thumb screw is needed for the low height option.
Do not discard the additional screws as they will be needed for Tall Height Option
D. Placing the Remote Control in the Storage Area
• Locate the remote control that has been provided with the tower fan.
Make sure that the remote control is not thrown out with
the packing materials.
• Install batteries into the remote control battery compartment
Battery Installation/Replacement Instructions).
(see
• Place the remote control in the recessed remote holder located on the top of the fan. (Fig. 5)
Fig. 1
A
B
Base Assembly
Fig. 2
Fig. 3
Fig. 4
Fig. 5
ASSEMBLY INSTRUCTIONS FOR TALL FAN HEIGHT OPTION (Using pedestal height extender)
NOTE: Product is most stable when pedestal extender is not used. A. Pedestal Assembly
• Line up the left and right pedestal assembly and firmly snap together
. (Fig. 6).
Fig. 6
Pedestal Assembly
ASSEMBLY INSTRUCTIONS (cont’d)
B. Base Assembly
• Align the two portions of the circular base and snap together by gently pushing the 4 round extrusions (Fig. 7, Item A) into the adjacent circles of the connecting piece (Fig. 7, Item B)
C. Securing the Pedestal to the Base
• Line up the arrow marked as on the pedestal with the arrow marked as on the base. (Fig. 8) Align the 3 round extrusions with the 3 holes in the base.
•Secure the base assembly to the pedestal by inserting and tightening the 3 thumb screws in the 3 holes located on the bottom of the base. (Fig. 9)
D. Securing the Tower Fan to the Pedestal
• Carefully turn the fan on its side. Place the power cord through the center of the pedestal and base assembly.
• Align the pedestal arrow marked as with the tower fan arrow marked as . Firmly hold the base steady and rotate the pedestal assembly clockwise to lock the tower fan in place. (Fig. 10)
• Secure the pedestal to the tower fan by inserting and tightening 1 thumb screw in the opening located near the top rear of the pedestal assembly. (Fig. 11)
E. Securing the Cord to the Base
• With the fan still on its side, locate the cord holding bracket on the bottom of the base.
• Gently pull any slack out of the power cord, place the power cord securely in the holding bracket and secure the power cord bracket over the power cord. (Fig. 12)
• Return the tower fan to its upright position. Note: Do not operate the tower fan unless it is in its proper,
upright position. Note: Only one thumb screw is needed for the low height
option. Do not discard the additional screws as they will be needed for Tall Height Option
F. Placing the Remote Control in the Storage Area
• Locate the remote control that has been provided with the tower
Make sure that the remote control is not thrown out with
fan.
the packing materials.
• Install batteries into the remote control battery compartment (see
y Installation/Replacement Instr
Batter
uctions
).
• Place the remote control in the recessed remote holder located on the top of the fan. (Fig. 13)
Fig. 7
A
B
Base Assembly
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
BATTERY INSTALLATION/REPLACEMENT INSTRUCTIONS
Coin
+
+
Separate the front and rear housing by inserting a small coin into the two recessed
A.
slots located on the bottom of the remote (Fig 14). Twist the coin until the housings separate. Pull the remote open, separating the halves (Fig. 15). This will automatically force the lens cover to dislodge.
B. Insert 2 AAA batteries into the remote following the directional guides in the recessed
slots (Fig. 16).
C. Snap the remote together by lining up the front and back and firmly pressing
together.
Fig. 14 Fig. 15 Fig. 17
Fig. 16
NOTE: DO NOT MIX OLD AND NEW BATTERIES. DO NOT MIX ALKALINE, STANDARD (CARBON-ZINC) OR RECHARGEABLE (NICKEL-CADMIUM) BATTERIES.
FAN OPERATIONFAN OPERATIONEFY-041 SERIES AND HY-041 SERIES FAN OPERATION
On/Off
To tur n fan on, press the Power button () located on the center of the control panel.
Speed Control
The fan will automatically start on the High speed setting ( ) when initially turned on. To adjust the speed up or down, press the
Speed button
twice for Medium speed ( ). Pressing the will return the fan to High speed operation.
Note: When the fan is turned off and restarted using the Power button, it will operate in the same speed setting that it was last set to. If unplugged, the fan will reset to start on High speed when turned on again.
Breeze Mode
Press the Breeze Mode button ( ) once to operate Breeze Mode in the low breeze
A.
setting ( ). The low breeze mode operates in accordance with the chosen speed setting of the fan as follows:
• High Fan Speed: Breeze Mode will alternate between the high and medium speed settings
• Medium Fan Speed: Breeze Mode will alternate between the medium and low speed settings
• Low Fan Speed: Breeze Mode will alternate between the low and off setting
B. Press the Breeze Mode button a second time to operate the fan in high Breeze
Mode ( ). This will operate the fan in a random high/medium/low pattern regardless of the speed setting.
C. Press the Breeze Mode button a third time to turn the Breeze Mode off. Oscillation
To activate the Oscillation feature, press the Oscillation button ( ) once. Press the
Timer
The Timer can be set in two hour increments. Choose from 2, 4, 6, or 8 hour settings by performing the following function:
• 2 hours: Press the
• 4 hours: Press the
• 6 hours: Press the
• 8 hours: Press the
Press the
once for Low speed ( ), and
Fan Speed button a third time
Oscillation button again to turn the Oscillation feature off.
Timer button ( ) once. Timer button twice. Timer button a third time. Timer button a fourth time.
Timer button a fifth time to turn the Timer feature off.
Fan
EFY-041 SERIES REMOTE CONTROL OPERATIONEFY-041 SERIES AND HY-041 SERIES REMOTE CONTROL OPERATION
Note: The Remote Control functions the same
as the control panel on the fan.
On/Off:
Press the Power button ( ) once to turn the fan on. Press the Power button a second time to turn the fan off.
Speed Control
The fan will automatically start on the High speed setting when initially turned on. To adjust the speed up or down, press the
Speed button Speed button
Note: When the fan is turned off and restarted using the Power button, it will operate in
the same speed setting that it was last set to. If unplugged, the fan will reset to start on High speed when turned on again.
Breeze Mode A.
Press the Breeze Mode button ( ) once to operate Breeze Mode in the low breeze setting. The low breeze mode operates in accordance with the chosen speed setting of the fan as follows:
• High Fan Speed: Breeze Mode will alternate between the high and medium speed settings
• Medium Fan Speed: Breeze Mode will alternate between the medium and low speed settings
• Low Fan Speed: Breeze Mode will alternate between the low and off setting
B. Press the Breeze Mode button a second time to operate the fan in high Breeze
Mode. This will operate the fan in a random high/medium/low pattern regardless of the speed setting.
C. Press the Breeze Mode button a third time to turn the Breeze Mode off. Oscillation
To activate the Oscillation feature, press the Oscillation button ( ) once. Press the
Timer Function
The Timer can be set in two hour increments. Choose from 2, 4, 6, or 8 hour settings by performing the following function:
• 2 hours: Press the
• 4 hours: Press the
• 6 hours: Press the
• 8 hours: Press the
Press the
once for Low speed, and twice for Medium speed. Pressing the Fan a third time will return the fan to High speed operation.
Oscillation button again to turn the Oscillation feature off.
Timer button ( ) once. Timer button twice. Timer button a third time. Timer button a fourth time.
Timer button a fifth time to turn the Timer feature off.
Fan
EFY-041 SERIES REMOTE CONTROL OPERATIONEFY-041 SERIES AND HY-041 SERIES REMOTE CONTROL OPERATION (cont’d)
Flashlight Feature:
Press and hold the Flashlight button ( ) located on the back of the remote control to activate the Flashlight.
Note: Only one bulb will activate when using the flashlight feature. The Remote Control has only one light. The second bulb is the Remote Transmitter.
Remote Control Storage
The remote control may be stored in the recessed area located behind the controls when it is not in use.
EFY-045, EFY-047 SERIES, HY-047 AND HY-048 SERIES FAN OPERATION
Power and Speed Mode
Press the Power button ( ) once: Fan will activate and run on High speed ( )
A. B. Press the Power button twice: Fan will change to Medium speed ( ) C. Press the Power button a third time: Fan will run at Low speed ( ) D. Press the Power button a fourth time: Fan will turn off Note: The fan will run continuously on high speed when initially activated. The
temperature displayed will be the current ambient temperature.
Timer and Temperature Mode A.
Pressing the Mode button ( ) once will activate the Temperature Mode. The thermometer icon ( ) will display and blink on the LCD screen and the desired room temperature will be displayed. The default temperature setting is 74°F (23°C). To change the temperature setting, press the be programmed in two degree increments between 60°F (16°C) and 90°F (32°C). The temperature will set within 5 seconds of the last time the Up and Down buttons are pressed. The thermometer icon will stop flashing and the current room temperature will once again be displayed. The fan will automatically turn off when the selected temperature is reached. If the room temperature exceeds the selected temperature setting, the fan will turn on.
B. Press the Mode button a second time to activate the Timer Mode. The clock
icon ( ) will display and blink on the LCD screen. Note: The temperature set mode will automatically disengage once the Timer Mode
is activated. The LCD screen will display a default timer setting of 10 hours. To set the timer, use the 12 hours in 1 hour increments.
Up and Down buttons to set the timer off function between 1 and
Up and Down buttons ( ). The fan may
EFY-045, EFY-047 SERIES, HY-047 AND HY-048 SERIES FAN OPERATION (CONT’D)
The timer will set itself within 5 seconds of the last time the Up and Down buttons are pressed. The timer icon will stop flashing. The current room temperature will once again be displayed along with the chosen timer hour setting followed by “HR”. When time runs out the fan will turn off.
C. Press the Mode button a third time to activate the combined Temperature/Timer
Mode. In this mode your fan will operate based on the temperature and timer settings set previously in A and B. If you have not set one of your modes, you may press the
Temp/Timer Mode button a fourth time to start over and follow instructions A and B.
D. Press the Mode button a fourth time to disengage the Temperature/Timer modes
and return to the continuous run mode. Note: When operating in either mode, the temperature or timer can be adjusted by
pressing the the last adjustment is made. When operating in the Temperature/Timer combination mode, no changes can be made to the previous settings. To change the temperature or timer settings for the combination mode, you must go back through the temperature and timer set modes and then enter the combination mode.
Oscillation and Ionizer Mode
The fan may be operated in Oscillation or Ionizer mode independently or may be operated using both features simultaneously.
A. Press the Oscillation/Ionization button ( ) once to activate oscillation B. Press the Oscillation/Ionization button twice to activate ionization in addition to
oscillation
C. Press the Oscillation/Ionization button a third time to operate the ionizer and turn
the oscillation fan off
D. Press the Oscillation/Ionization button a fourth time to turn the ionizer off. Breeze Mode
Press the Breeze Mode button ( ) once to operate Breeze Mode in the low breeze
A.
setting. The low breeze mode operates in accordance with the chosen speed setting of the fan as follows:
• High Fan Speed: Breeze Mode will alternate between the high and medium speed settings
• Medium Fan Speed: Breeze Mode will alternate between the medium and low speed settings
• Low Fan Speed: Breeze Mode will alternate between the low and off setting
B. Press the Breeze Mode button a second time to operate the fan in high Breeze
Mode. This will operate the fan in a random high/medium/low pattern regardless of the speed setting.
C. Press the Breeze Mode button a third time to turn the Breeze Mode off. °F to °C Display Change
This is done by simultaneously pressing and holding the Up and Down buttons ( ) for 2 seconds.
Note: The EFY-045, EFY-047, HY-047 and HY-048 Series are not air purifiers. These fans are equipped with an ionizer feature which helps freshen the air with negative ions creating a crisp, natural sensation. These units do not make any claims
egarding air cleaning or purification and should not be expected to perform as such.
r If you have allergy or asthma symptoms that could be triggered by the presence of an ionizer, an alternate product would be advisable.
Up or Down buttons. The appropriate icon will blink for 5 seconds after
EFY-045 SERIES, HY-047 SERIES AND HY-048 SERIES REMOTE CONTROL OPERATION
Power and Fan Speed Mode
Press the Power button ( ) once: Fan will
A.
activate and run on High speed ( )
B. Press the Power button twice: Fan will
change to Medium speed ( )
C. Press the Power button a third time: Fan
will run at Low speed ( )
D. Press the Power button a fourth time: Fan
will turn off
Note: The fan will run continuously on high speed when initially activated. The temperature displayed will be the current ambient temperature.
Up and Down Buttons When the fan is operating in Temperature or Timer Mode, press the Up or Down
buttons Note: The Temperature and Timer, or the combined Temperature/Timer mode cannot be
entered by using the remote control.
Oscillation and Ionizer Mode
The fan may be operated in Oscillation or Ionizer mode independently or may be operated using both features simultaneously.
A. Press the Oscillation/Ionization button ( ) once to activate oscillation B. Press the Oscillation/Ionization button twice to activate ionization in addition to
C. Press the Oscillation/Ionization button a third time to operate the ionizer and turn
D. Press the Oscillation/Ionization button a fourth time to turn the ionizer off. Note: The Ionizer is activated when the green light on the receiver is on.
( ) on the remote control to change the temperature or timer settings.
oscillation
the oscillation off
Breeze Mode
Press the Breeze Mode button ( ) once to operate Breeze Mode in the low breeze
A.
setting ( ). The low breeze mode operates in accordance with the chosen speed setting of the fan as follows:
• High Fan Speed: Breeze Mode will alternate between the high and medium speed settings
• Medium Fan Speed: Breeze Mode will alternate between the medium and low speed settings
• Low Fan Speed: Breeze Mode will alternate between low and off setting
B. Press the Breeze Mode button a second time to operate the fan in high Breeze
setting ( ). This will operate the fan in a random high/medium/low pattern regardless of the speed setting.
C. Press the Breeze Mode button a third time to turn the Breeze Mode off.
EFY-045 SERIES, EFY-047, HY-047 AND HY-048 SERIES REMOTE CONTROL OPERATION (CONT’D)
Flashlight Feature:
Only one bulb will activate when using the flashlight feature. The Remote Control
Note:
has only one light. The second bulb is the Remote Transmitter. Press and hold the Flashlight button ( ) located on the back of the remote control to
activate the Flashlight.
Remote Control Storage
The remote control may be stored in the recessed area located behind the bezel controls when it is not in use.
CLEANING AND STORAGE EFY-041, HY-041, EFY-047, HY-047 AND HY-048 SERIES
A. CLEANING THE FILTER
The filter feature is only available on the EFY-041 Series, EFY-047 Series,
Note:
HY-041 Series, HY-047 Series, and HY-048 Series. The EFY-045 Series does not have this feature.
The filter is located behind the rear grille of the fan. To clean the filter:
• Be sure the fan is turned off and the power cord in unplugged from the outlet.
Fig. 18
• Gently unsnap the rear grille from the fan (Fig. 18) and remove the filter.
• Run the filter under
cool water to remove the accumulation
of particles.
• Once filter has been cleaned let it dry
completely before placing
back in fan. Do not wring, bend or pull on the filter as this may cause damage.
• Once the filter is
completely dry, replace the filter and firmly snap rear
grille cover back in place.
B. CLEANING THE FAN
Fig. 19
Filter
• Ensure the fan is turned off and unplugged.
• Use only a soft cloth to gently wipe the outer surfaces of the fan clean.
• To clean between the grilles and fan blade area, we recommend using a pipe cleaner, flexible dustwand, vacuum cleaner or compressed air to gently remove the dust.
• To clean the rear grille use a soft dry cloth. Once the rear grille is clean replace filter and rear grille before operating. (Fig. 19)
Grille
This fan is equipped with a safety “OFF” switch to prevent the fan
om operating if the r
fr DO NOT immerse the fan in water and never allow water to drip into
ear grille is r
emoved or not properly assembled.
the motor housing.
• DO NOT use gasoline, paint thinner or other chemicals to clean the fan.
• For storage, you may leave the fan assembled and covered to protect it from dust. Store the fan in a cool, dry place.
CLEANING AND STORAGE EFY-045 SERIES
• Be sure the fan is turned off and the power cord is unplugged from the outlet.
• Use only a soft, damp cloth to gently wipe the outer surfaces of the fan clean.
• To clean between the grilles, we recommend using a pipe cleaner, flexible dustwand, vacuum cleaner or compressed air to gently remove the dust.
• DO NOT immerse the fan in water and never allow water to drip into the motor housing.
• DO NOT use gasoline, paint thinner or other chemicals to clean the fan.
• For storage, you may leave the fan assembled and covered to protect it from dust. Store the fan in a cool, dry place.
Loading...
+ 25 hidden pages