IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HUMIDIFIER
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
1. Always place this humidifier on a firm, flat and level surface. This humidifier may not work properly on an uneven surface.
2. Place this humidifier in an area where it is not accessible to children.
3. Do not place the humidifier near any heat sources such as stoves, radiators, and heaters.
4. Before using the humidifier, check the power cord for any signs of damage. If the cord is found to be damaged, DO NOT USE and return the humidifier to the manufacturer under the warranty agreement for repair.
5. This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt too defeat this safety feature.
6. To disconnect the humidifier, first turn controls to the OFFposition, then grip the plug and pull it from the wall outlet. Never pull by the cord.
7. A loose fit between the AC outlet (receptacle) and plug may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn outlet.
8. The humidifier should always be unplugged and emptied when not in operation or while being serviced or cleaned.
9. Never tilt or attempt to move the humidifier while it is operating or filled with water. UNPLUG the humidifier before moving.
10. This humidifier requires regular cleaning. Refer to the CLEANING instructions provided. Never clean the humidifier in any manner other than as instructed in this manual.
11. Turn the humidifier OFF if the relative humidity exceeds 60%, or if you notice moisture on the inside of your windows. For proper humidity reading use a hygrometer, which is available in many hardware and department stores or by ordering one from the manufacturer (see Care Products).
High
Low
Off
INTRODUCTION
Thank you for purchasing a Duracraft®Natural Cool Moisture®humidifier. If you would like more information on our full line of products please visit our website at: www.honeywell.com/yourhome.
HOW DOES IT WORK?
Natural Cool Moisture®System The fan pulls dry air through a wet filter and releases invisible moisture into the air. When the unit is running you will not see or feel a “mist”. You will know your humidifier is putting moisture into the air as you watch the water level in your tank decrease throughout the day.
®
The Duracraft when the air is dry and lowers the moisture output when the humidity level is high. This automatically helps to adjust the output for maximum comfort and helps prevent condensation.
WHAT IS AgION™ ANTIMICROBIAL?
Your DURACRAFT®Natural Cool Moisture®filter has been designed using new AgION™ technology which prevents the growth and migration of surface mold, mildew, fungus and odor causing bacteria in the filter for the filter’s life, approximately one season. Keep in mind, depending on your water quality, mineral deposits can still clog or discolor the filter and affect humidifier performance.
MODEL DH-890
exclusive Automatic Moisture Balance System®increases moisture output
MOTOR HOUSING
Your humidifier is made up of the following parts:
NATURAL COOL MOISTURE®FILTER
RINSE-TO-CLEAN BASE
WATER TANK
FILL CAP
®
SET UP
NOTE: We recommend that the humidifier be disinfected prior to first use.
Please see CLEANING instructions.
• Select a firm, level, flat location — at least six inches (15 cm) from any wall for proper air
flow (Fig. 1).
• Place the humidifier on a water-resistant surface, as water can damage furniture and some
flooring. Duracraft
®
will not accept responsibility for property damage caused by water
spillage.
FILLING
Fig. 1
6”
• Remove the water tank by grasping the handle and pulling straight up (Fig. 1).
• Lift up on the Motor Housing to remove and set aside (Fig. 2). Remove the Natural Cool
Moisture
®
filter from the base before filling the unit with water. Soak in a sink full of cool water to help reduce mineral build up and place back in the humidifier while wet. DO NOT SQUEEZE OR WRING OUT THE NATURAL COOL MOISTURE your filter repeat this step each time you fill your humidifier.
• Turn the water tank upside down so that the fill cap is facing up; unscrew the fill cap by turning it counter-clockwise and set aside.
Fig. 2 Fig. 3
Wall
Lift
®
FILTER. To help extend the life of
• Fill the water tank with COOL tap water (Fig. 3). Distilled water is not necessary as the water is filtered by the Natural Cool Moisture
®
filter. DO NOT USE HOT WATER. Doing so may
damage the humidifier.
• Replace the fill cap by turning it clockwise . DO NOT OVER TIGHTEN. Turn the water tank right-side up.
FILLING CONTINUED
NOTE: WHEN CARRYING THE FILLED WATER TANK, PLEASE USE THE HANDLE AND PLACE
YOUR OTHER HAND UNDER THE TANK FOR ADDITIONAL SUPPORT.
®
• Place the Motor Housing back onto Rinse-to-Clean
Base.
• Once the filled tank has been positioned, do not attempt to move the humidifier. If it has to be moved, unplug the humidifier and remove the water tank first.
NOTE: DO NOT POUR WATER INTO THE GRILL ON THE TOP OF THE MOTOR HOUSING.
DOING SO MAY DAMAGE THE HUMIDIFIER OR CAUSE PERSONAL INJURY.
OPERATION
CAUTION: DO NOT PLUG IN THE HUMIDIFIER WITH WET HANDS AS AN ELECTRIC SHOCK
COULD OCCUR.
POWER
• With the power switch in the OFF position, plug the filled humidifier into a polarized 120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET; it will only fit one way.
HUMIDITY CONTROL
Fig. 4
1. Set the fan speed control to the desired position (Fig. 4).
HIGH: For fast humidifying
High
Low
ff
O
LOW: For quieter operation
NOTE: The length of time your humidifier runs will vary depending on the quality of
construction and insulation of your room and house, as well as the fan speed.
2. Turn the humidifier OFF if the humidity level feels too moist or you notice condensation
forming on the walls and/or windows.
®
ALWAYS be sure to empty any unused water in the Rinse-to-Clean
Base and/or Water Tank
each time you refill the water tank or finish using the humidifier.
WEEKLY CLEANING
We recommend cleaning the humidifier once a week, more often if you have hard water or notice a build up of impurities or detect unpleasant odors.
NOTE: THE USE OF OTHER WATER TREATMENT PRODUCTS MAY DAMAGE THE FILTER OR HUMIDIFIER.
Cleaning involves two steps SCALE REMOVAL and DISINFECTING. Be sure to perform these in the proper order to avoid harmful chemical interactions.
• First, turn off and unplug the humidifier.
• Remove the Water Tank and Motor Housing.
• Remove the Natural Cool Moisture®filter from the Rinse-to-Clean®Base.
• Discard any residual water from the Base.
• Clean all outside surfaces with a dry, soft cloth. DO NOT USE WATER. THIS MAY DAMAGE THE HUMIDIFIER OR CAUSE ELECTRIC SHOCK.
NOTE: Remove filter before cleaning
Failure to remove the filter during cleaning will destroy the filter
STEP ONE:
SCALE REMOVAL
Rinse-to-Clean®Base
®
1. Fill the Rinse-to-Clean either:
• one cup (8 ozs) of undiluted white vinegar
OR
®
• DuraRinse
Humidifier Cleaner, part no. AC-816, following bottle instructions
2. Let solution stand for 20 minutes
3. With the vinegar or DuraRinse Rinse-to-Clean
®
interior surfaces with a soft cloth or brush to help remove scales.
4. Rinse the Rinse-to-Clean thoroughly with water to remove scale and cleaning solution.
Base with
Base clean all
®
Base
®
in the
STEP TWO:
DISINFECTING
Water Tank
1. Fill the water tank with:
• 1 teaspoon of household bleach
• 1 gallon of water. Pour some of this solution into the Rinse-to-Clean
2. Let solution stand for 20 minutes.
3. Rinse with water until the odor of bleach is gone.
®
Base.
PROLONGING THE LIFE OF THE FILTER AND MAINTAINING A CLEAN HUMIDIFIER
NOTE: DO not attempt to clean the Natural Cool Moisture®filter with any chemical solutions,
doing so will damage the filter.
®
• If the Natural Cool Moisture soak it in a sink full of cool water for 10 minutes. DO NOT SQUEEZE OR WRING OUT THE NATURAL COOL MOISTURE
filter appears to be clogged by hard water or mineral deposits,
®
FILTER. Always place it back in the humidifier wet.
There are many steps you can take each time you fill your humidifier to make sure you get the most life out of our Natural Cool Moisture
1. To prevent mineral deposits use DuraFree
®
filter.
®
Humidifier Descaler Water Softener, part
no. AC-817, each time the Water Tank is refilled.
®
2. Treat the Natural Cool Moisture
filter with care. DO NOT squeeze or wring it out, DO NOT
clean the filter using any chemical solution.
®
3. Always purchase Honeywell Brand Natural Cool Moisture
of this humidifier and the Natural Cool Moisture
®
filter are designed to function
filters as the fan motor
efficiently as a set. Using any other filter could damage the motor or impair the humidifier’s performance.
4. Be sure to empty water from the Water Tank and Base when not in use.
NOTE: AgION™ prevents the filter from growing fungus and bacteria. It is normal for the filter
to turn brown or rust colored from mineral build-up. This will vary depending on water quality.
END-OF-THE-SEASON CARE AND STORAGE
• Follow weekly CLEANING instructions when the humidifier will not be used for at least one week or more, or at the end of the season.
• At the end of the season, remove and throw away the filter; do not store with a used filter.
• Dry the humidifier completely before storing. Do not store with water inside the Base or Water Tank.
• Pack the unit in its original carton and store in a cool, dry location.
• Before next use, remember to install a new filter and clean the humidifier.
TROUBLE SHOOTING
Q: I hear the fan turning, but I don’t see any mist. Is my humidifier operating properly?
A: Dry air is pulled through the Cool Moisture system and a fan disperses invisible, moisture
balanced air. There is no “mist” emitted. When operating normally you will feel only cool air coming from the unit. Monitor the water level in your tank/base. If you notice a decrease in the water tank over 24 hours then the unit is operating normally.
Q: My unit has been running for several hours. I hear the fan spinning, but I do not notice the
water level in the tank decreasing.
A: First, check the moisture pad to be sure it is wet. If the pad appears dry, remove it from the
base and gently rinse under cool water. Reposition wet filter in the base. You may also want to check the current moisture level in your home. If the humidity level is over 60%, the unit will not put out much moisture as your air is already saturated.
Q: My filter has turned light brown and rust colored. Do I need a new filter?
A: Probably not. Since your filter has been made with AgION™ technology the change in
color indicates only a mineral deposit. Soak filter in a sink full of cool water to help break up deposits. The discoloration may remain but will not effect the humidifier’s performance.
ELECTRICAL RATINGS
This product is rated at 0.6 amps, 120V, 60 Hz.
NOTE: IF YOU EXPERIENCE A PROBLEM WITH YOUR HUMIDIFIER PLEASE SEE THE WARRANTY INSTRUCTIONS. PLEASE DO NOT ATTEMPT TO OPEN OR REPAIR THE HUMIDIFIER YOURSELF. DOING SO WILL VOID THE WARRANTY AND COULD CAUSE DAMAGE TO THE UNIT OR PERSONAL INJURY. IF THE PROBLEM PERSISTS PLEASE CONTACT THE CONSUMER SERVICE CENTER.
CUSTOMER ASSISTANCE
Mail questions or comments to: Honeywell
Consumer Service Center 250 Turnpike Road Southborough, MA 01772
Please be sure to specify model number.
Call us toll-free at: 1-800-554-4558
Or visit our website at: www.honeywell.com/yourhome
0
3
0
5
0
1
0
0 D
R
Y
C
O
M
F
O
R
T
D
A
M
P
%
CARE PRODUCTS
If your local dealer is out of stock, Duracraft®replacement parts and care products may be ordered directly. You can call 1-800-554-4558 to order with a MasterCard, Visa or Discover or fill out the form below and mail it along with a check or money order (sorry no COD’s accepted) to:
Honeywell Consumer Service Center 250 Turnpike Road Southborough, MA 01772
Please allow four to six weeks for delivery. Massachusetts residents please add 5% Sales Tax.
PRICE
Item Item No. Qty. US CAN Total
Natural Cool Moisture®Filter, one per pack AC-888 $ 9.99 $13.50 DuraSept®Humidifier Bacteriostatic Treatment(32 oz.) AC-802 5.00 6.75
DuraFree®Humidifier Water Softener DuraRinse®Humidifier Cleaner (32 oz.) AC-816 5.00 6.75 Rinse-to-Clean Base DH-890-1 10.00 13.50
Water Tank and Fill Cap DH-890-2 19.99 27.00 Fill Cap DH-890-3 5.00 6.75
Digital Hygrometer and Thermometer (F°/C°)
Measure room temperature and humidity level. Free standing can be used anywhere in the room. Display Temperature.
MA Residents add 5% Sales Tax/CAN residents only add 7% GST
Shipping and Handling
Name Check or Money Order Enclosed
(32 oz.) AC-817 5.00 6.75
HAC-555 19.99 27.00
SUBTOTAL
(US residents add $4.95/CAN residents add $7.00)
TOTAL ENCLOSED
Address Credit Card No.
Exp. Date
Day Time Phone Signature
Loading...
+ 25 hidden pages