1. UNRAVEL CORD BEFORE USE. Failure to do so could
cause overheating and possible fire hazard.
Always disconnect cord at electrical outlet before
removing the steam unit or when vaporizer is not
in use. Allow steam unit to cool before handling.
2. FILL WATER CONTAINER: Remove steam unit. Fill
container with tap water to water level marking
on bowl. DO NOT OVERFILL.
(Figure A)
3. ADD SALT: For tap water of low or moderate mineral
content, ADD 4 TO 5 PINCHES (1/8 teaspoon) of
ordinary table salt to the water and mix thoroughly.
(Figure B)
Salt has no effect on the purity of the steam or
medication.
Caution: Too much salt can cause excessive
boiling or blown fuse.
4. REPLACE STEAM UNIT. Hold down steam unit for ten
seconds to allow water to enter the housing and
seat it properly in water container. If steam unit
floats, container is overfilled.
(Figure C)
5. PLACE VAPORIZER IN A SAFE POSITION. Vaporizer
should always be placed on a firm, flat surface
at least four feet away from bedside. For safest
operation, vaporizer should be placed on floor,
where it cannot fall or be pulled down. Be sure
the vaporizer is in a stable position and power cord
is out of the way to prevent vaporizer from being
upset or tipped over.
☞
PROTECT floor, rug or furniture by placing the
vaporizer on a non-metallic heat-resistant surface.
CAUTION: Do not direct steam flow directly at
patient, walls or furniture. You will still obtain desired
level of humidity. KEEP OUT OF THE REACH OF
CHILDREN, ESPECIALLY CRAWLING INFANTS
AND TODDLERS; STEAM CAN CAUSE BURNS.
6. KAZ INHALANT MEDICATION: For best results fill the
medication cup on the steam unit (located directly
below and in front of the steam outlet) with one
tablespoon of KAZ INHALANT.
(Figure D)
Do not pour any other brand of medication into
the water container. It will damage the unit and
void our guarantee.
7. PLUG IN: Plug power cord into 110-120
Volts AC outlet in good condition fused
for at least 15 Amps. Do not use with
extension cords.
This product has a polarized plug (one
blade is wider than the other) as a safety
feature. This plug will fit into a polarized
outlet only one way. If the plug does not
fit fully into the outlet, reverse the plug.
If it still does not fit, contact a qualified
electrician. DO NOT ATTEMPT TO
DEFEAT THIS SAFETY FEATURE.
Vaporizer will produce a gentle flow of
steam within a few minutes. If steaming
does not start within ten minutes, see
Troubleshooting checklist. The vaporizer
will automatically stop producing steam
when water has reached minimum level
(about 3/4 inch from bottom of container).
The night-light will remain on, indicating
that the vaporizer is plugged in.Always
unplug steam unit and allow to cool
before removing from water container.
☞
Under conditions of rapid boiling and
near the end of each operation, steam
may emerge from Safety Vents (in front
corners of night-light lens). This condition
is normal, preventing overboiling by
relieving steam pressure.
(Figure E)
☞
Do not lift or move vaporizer while it
is in use.
8. Use fresh water and medication each
time vaporizer is used.
NOTE: All medicinal ingredients of Kaz
Inhalant are released in use, leaving only
the mineral oil base in medication cup.
This should be emptied after operation.
Medication cup can be cleaned with a
piece of cotton.
9. AFTER EACH USE: Empty any unused
water from the water container. Shake
container gently back and forth to remove
any remaining water. Rinse container
thoroughly with water, drain and wipe
with a dry, clean cloth.
IMPORTANT: To maintain proper operation
of your vaporizer, be sure to follow
Care
and Cleaning Instructions.
Instructions
Figure A
Troubleshooting: What To Do If…
Figure C
Figure B
Figure D
Figure E
…Vaporizer does not operate or steams
too slowly:
1. Make sure vaporizer is plugged in and
the night-light is lit.
If the night-light is not on, you may have
a blown fuse, tripped circuit breaker or a
defective electrical outlet. Try a different
outlet or you may want to contact an
electrician to check out the potentially
defective outlet.
2. The fault may be the low mineral content
of the water in your area.
Unplug vaporizer from electrical outlet,
remove steam unit, add one or two
PINCHES of salt to the water and mix
thoroughly. Replace the steam unit and
plug in vaporizer. It should steam within
5 minutes. Add salt only by the PINCH,
since too much salt can cause excessive
boiling or blowing of fuse.
3. If vaporizer has been operating normally
and is now failing to steam, it needs
to be cleaned. See the “Weekly
Maintenance” section of
Care
and Cleaning Instructions.
…Vaporizer operates too fast, fuse
blows or circuit breaker trips:
Overboiling, flickering lights, blown fuse or
heavy steam flow from Safety Vents generally
indicates one of the following causes...
1. Too much salt was added to the water.
To correct the condition: Disconnect
vaporizer from electrical outlet, pour out
water and rinse container. Rinse steam
unit as described in “Weekly Maintenance”
section of
Care and Cleaning Instructions.
Refill with fresh water but DO NOT ADD SAL T.
If vaporizer now does not operate or
steams too slowly, see above.
2. You live in a “hard water” area and
minerals in the tap water are causing
the vaporizer to steam too rapidly.
To correct the condition: Disconnect
vaporizer from electrical outlet, pour
out water and rinse container. Rinse
steam unit as described in “Weekly
Maintenance” section of
Care and
Cleaning Instructions.
Refill with fresh
water but DO NOT ADD SALT.
If unit still steams too rapidly, use
1/2 distilled water and 1/2 tap water.
Food and drug stores usually stock
distilled water.
In “hard water” areas it is advisable
to clean the unit every few days in
accordance with the “Weekly
Maintenance” section of
Care
and Cleaning Instructions.
…Vaporizer is making crackling/
buzzing/humming sounds or water
container is unusually hot:
1. You may have added too much salt.
See above.
2. You may live in a “hard water” area.
See above.
3. This may be an indication your vaporizer
needs cleaning. Refer to the “Weekly
Maintenance” section of
Care and
Cleaning Instructions.
If you are still experiencing difficulty
in operating your vaporizer, please
call our Consumer Service
Department at 800-477-0457.
Special Notes
Discoloration/Black Particles
After use, the water residue in the bottom
of the container may contain black particles,
and, in some areas, the water and the bottom
of container may discolor. These conditions
are normal and do not affect the purity of the
steam or medication. The container is easily
cleaned with soap and water. Rinse and dry
the container after cleaning.
Ventilation
When vaporizer is used in closed or small
rooms, check periodically for proper ventilation,
as excessive humidity can cause condensation
stains on walls.
Storage of Vaporizer
When vaporizer is not in use, clean thoroughly,
following
Care and Cleaning Instructions.
Dry all parts and store in a cool, dry location.
NEVER store with water in the container!
Condition of Sale
As a condition of sale, the purchaser assumes
responsibility for the proper care and use of
this appliance in accordance with our printed
instructions. The purchaser or user must
judge for himself or herself when to use it
and length of use.
This vaporizer is warranted against defective
materials and workmanship. See carton for
warranty period. Any defective part will be
replaced at no charge if it has not been
tampered with and appliance has been used
according to our printed directions. Warranty
gives you specific legal rights; you may have
other rights which vary from state to state.
If you experience unsatisfactory operation,
first follow
Troubleshooting and Care and
Cleaning Instructions.
If the unit still does
not operate satisfactorily, call our Consumer
Service Department at 800/477-0457 or
write to Vaporizer Service Department,
4411 Route 9, One Vapor Trail, Hudson, NY
12534, explaining just how the vaporizer is
operating. Specify model number. Our
Consumer Service Representative will provide
further instructions on how to correct the
trouble yourself, or will ask you to return
the steam unit for repair or replacement.
Limited Warranty