Thank you for choosing a Katadyn portable water microfiltration system.
The Katadyn Gravity Camp 6L and Katadyn Base Camp Pro 10L Micro lters meet industry standards for reduction of bacteria (99.9999% Klebsiella terrigena) and protozoan cysts (99.9% Giardia and Cryptosporidium). These products are designed to be used with untreated fresh water sources, such as lakes, rivers and streams. They are ideal for single persons or small groups while trekking or camping. These portable water  lters are designed for the  ltering of water only – never use it for any other purposes.
KEY COMPONENTS
Bag, Filter, Cap with built-in Quick Connector, Hose, On/Off output hose valve
Waterbag
Filter Cap with Quick Connector
On/Off Valve
HOW IT WORKS
The Katadyn Gravity Camp 6L and Katadyn Base Camp Pro 10L Micro lters utilize a cleanable  lter protection sheet as a pre lter to extend the cartridge life and on a second step a 0.2 micron Ultra Flow Filter Technology
TM
pleated glass ber cartridge to remove bacteria and protozoa like Giardia and amoeba as well as particles larger than 0.2 microns.
WARNING
IMPORTANT SAFETY MESSAGE
Read before using Katadyn Micro lter
When you travel abroad, camp or backpack, you run a risk of illness ranging
from the inconvenience and discomfort of diarrhea to more serious illnesses
caused by protozoan cysts (i.e., Giardia, Cryptosporidium), viruses and
bacteria.
The microorganisms that cause these diseases are often found in the food and
water you consume. Lakes, streams and the local water supply may also be
contaminated.
To minimize the risk of contracting these illnesses, we suggest that you consult
with your physician, state health department or travelers’ clinic 4 - 6 weeks
before you depart.
And while you are traveling
– Make sure that prepared food is thoroughly cooked to the following
instructions.
– Select non-cooked foods (fruits, nuts, etc.) that have intact shells or skins,
and clean your hands before peeling the food.
– Wash your hands with soap and warm water thoroughly and often,
especially before you eat.
– Filter all drinking water with your Katadyn Gravity Camp 6L Microlter or
Base Camp Pro 10L Microlter, including water used for brushing teeth, washing your face, etc.
WARNING
Improper use of this lter increases your risk of getting gastrointestinal illness. Read manual before assembling or using this water lter and f o l l o w a l l i n s t r u c t i o n s . I f y o u h a v e a n y q u e s t i o n s , c o n t a c t K a t a d y n a t +41 44 839 21 11 or email us at customerservice@katadyn.ch or visit our website at www.katadyn.com.
EN
DE
FR
NL
DK
SWE
NOR
Keep output hoses and other parts away from untreated water to prevent cross
contamination.
If there is any risk of virus in the water, use a registered disinfectant such as Micropur Forte Tablets as post treatment, boil your water or use 4 drops of ordinary household bleach.
PRODUCT SET-UP
The Camp Microlters require minimal set up. For best results, try out the products before rst use and familiarize yourself with their operation.
FIN
ESP
POR
1. Install Filter Protector (pre-assembled)
The Filter Protector is a cleanable screen that covers the Ultra Flow Filter Cartridge. A frequent cleaning is not required; however, using the Filter Protector will extend the life of your cartridge. It may be used continually or when source water contains suspended particulates or dirt.
Step 1: Wrap protector sheet around cartridge (there will be approximately a 5 cm overlap) and hold in place.
Step 2: Slip the exible netting over the cartridge. Adjust lter protector sheet and netting so they are positioned evenly. (Figure 1)
Step 1
Filter
Protective Screen
Step 2
Netting
TM
(Figure 1)
2. Install Filter
Screw cartridge clockwise inside cap as far as it will go. Do not grasp the cartridge around the pleated surface, since it may damage the  lter. Screw the cap clockwise on the external threads of the bag as far as it will go. Connect the output hose to cap by pushing the connector at hose into the cap connector until it clicks in place. (Figure 2)
Thread
EN
DE
On-Off Output Hose Valve
Cartridge
(Figure 2)
Cap
Quick Connection System including On/Off Valve
Outlet Hose
3. Flush System (Important!)
Before  rst use,  ush system by running approximately 2 liters of water through the unit to remove harmless particles and dust. See following section on Normal Operation on how to  lter water.
WARNING
Improper threading of  lter cartridge to cap could cause  uid leakage and result in illness.
Follow instructions for proper installation of the cartridge. A damaged and contaminated  lter could expose you to harmful microorganisms and result in illness.
Always handle  lter carefully.
If  lter has been dropped into contaminated water source, follow instructions
for storage to completely disinfect hoses and  lter before use.
If  lter is damaged or contaminated, do not use.