Kastel KP 21/5, KP 22/5, KP 25/6, KP 28/7, KP 30/10 User Manual

...
All rights reserved. No part of this publication may be reproduced without the written authorisation of the manufacturer
KASTEL s.r .l. - Via Fusina, 1/A - 31033 Castelfranco Veneto - Treviso - Italy
AUTOMA TIC ICE MAKER
USER MANUAL
I
GB
2
ENGLISH
INDEX
1. INTRODUCTION TO MACHINE OPERA TION Page 3
Operating cycle description Page 3 Operational diagram Page 3
2. TECHNICAL DA T A Page 4
Ice maker technical features Page 4 Dimensions table Page 5 Ice cube size Page 5
3. MALFUNCTIONS-CAUSES-ACTIONS TO BE T AKEN Page 6
4. P ARTS SECTION Page 8
Casing Page 8 Water system Page 10 Refrigerating system Page 12
5. A TTACHMENTS Page 14
Instructions booklet Page 14 Ice level thermostat adjustment diagram Page 23 Evaporator thermostat adjustment diagram Page 24 Timer operational diagram Page 25 Drain fitting diagram Page 26 Electrical diagram KP21 - KP25 Page 27 Electrical diagram KP28 - KP50 Page 28 Electrical diagram KP75 - KP130 Page 29 Electrical diagram KP160 Page 30 Refrigerating system diagram Page 31
IDENTIFICATION PLATE
3
ENGLISH
1
INTRODUCTION TO MACHINE OPERATION
OPERA TING CYCLE DESCRIPTION
Correctly connect the ice maker to power and water mains, fill up the water tank and bring the machine switch to position “I”. Power will get to the compressor, water pump and fan motors, switching them on to start the freezing cycle. The nozzles will begin spraying water into the caps. As the evaporator thermostat bulb reaches the right temperature, the freezing cycle timer starts off. At the set time, the water pump stops and the water load (to top up the tank) and cycle reversal solenoid valves are opened. Heat is pumped to the evaporator and, as a result, the ice cubes are dropped from the copper caps into the ice storage bin. When the bin is full, the ice level thermostat stops ice production. As the evaporator thermostat reaches the preset temperature, the cycle reversal timer starts off. At the set time, the water load and cycle reversal solenoid valves are closed and the machine starts a new freezing cycle.
OPERA TIONAL DIAGRAM
4
ENGLISH
2
TECHNICAL DATA
ICE MAKERS - TECHNICAL DETAILS
Mod. Production Storage Cooling G as Cubes in Voltage Power
24h capacity system refrigerant a cycle max.
(Kg) (Kg) (N°) (W)
KP 21/5 21 5 A R404A 24 230V~50Hz 420
21 5 W R404A 24 230V~50Hz 420
KP 22/5 22 5 A R404A 24 230V~50Hz 420
22 5 W R404A 24 230V~50Hz 420
KP 25/6 25 6 A R404A 24 230V~50Hz 420
25 6 W R404A 24 230V~50Hz 420
KP 28/7 28 7 A R404A 24 230V~50Hz 530
28 7 W R404A 24 230V~50Hz 530
KP 30/10 30 10 A R404A 24 230V~50Hz 530
30 10 W R404A 24 230V~50Hz 530
KP 44/15 44 15 A R404A 36 230V~50Hz 700
44 15 W R404A 36 230V~50Hz 700
KP 50/26 50 26 A R404A 36 230V~50Hz 800
50 26 W R404A 36 230V~50Hz 800
KP 75/40 75 40 A R404A 60 230V~50Hz 950
75 40 W R404A 60 230V~50Hz 950
KP 100/60 100 6 0 A R404A 60 230V~50Hz 1200
100 6 0 W R404A 60 230V~50Hz 1200
KP 130/75 130 7 5 A R404A 108 230V~50Hz 1350
130 7 5 W R404A 108 230V~50Hz 1350
KP 160/75 160 7 5 A R404A 108 230V~50Hz 1700
160 7 5 W R404A 108 230V~50Hz 1700
KP 150 MOD. 150 - A R404A 108 230V~50Hz 1700
150 - W R404A 108 230V~50Hz 1700
KP 300 MOD. 300 - A R404A 216 230V~50Hz 3500
300 - W R404A 216 230V~50Hz 3500
5
DIMENSION TABLE
ENGLISH
ICE CUBE DIMENSIONS
Ice cube weigh = 17 g
MACHINE MACHINE WITH PACKAGE
Mod. L P H Foot Net L P H Volume Gross
weight weight
(mm) (mm) (mm) (mm) (Kg) (mm) (mm) (mm) (m
3
) (Kg)
KP21/5 KP22/5 430 530 680 0,154 KP25/6 360 450 585 0÷10 35 38
KP28/7 605 38 710 0,18 42 KP30/10 685 40 790 0,2 44 KP44/15 685 52 820 0,31 57 KP50/26 795 55 930 0,35 61 KP75/40 915 72 1050 0,58 80
KP100/60 1015 87 1150 0,64 96 KP130/75 108 1 18 KP160/75 113 123
KP150 870 560 730 - 97 925 640 860 0,51 109 KP300 1255 595 860 - 153 1310 640 1015 0,9 170
350 450 575 34 37
390 465 466 536
500 585 0÷20 576 656
740 605 816 676
55÷85
840 740 1070 916 816 1210 0,9
6
ENGLISH
PROBLEM - REASON - SOLUTION
3
PROBLEM REASON SOLUTION
No water supply Check the water system
Sw itc h in g o n th e mach in e , it doesn’t start No power supply Check the electrical system
No refrigerant in the ice maker
Probable gas leak from the cooling system. Repear the leak
The condensation cycle is not correctly effected
Air cooled system:
-
possible faulty fan m otor
-
possible faulty pressure switch
Water cooled system:
- no water in the cooling system (see “ the safety therm ostat
operates”) Blow-by of the freon from the gas valve
Change gas valve Blow-by of water throught the
wa te r in le t va lv e
Change water inlet valve
The ice maker effects the cycle but it doesn’t produce ice
Low perform ance of the comp resso r
Change compressor
Dirty or faulty w ater pump
First clean water pump, eventually
change it Obstructed suntion filter of the pump
Check and clean the filter Faulty or obstructed water inlet
valve
First clean the valve, eventually
change it Faulty timer: it doesn’t open the valve
Change timer
Dirty or obstructed sprayers
Check the sparyers and clean
them Water leak from the bin Check bin seal
No water spraid during spaying period
The overflow gasket is damaged
Check and eventually change the
gasket The hot gas valve doesn’t open when operated
Check electrical system
Check the valva and eventually
change it Faulty evaporator therm ostat Change the thermostat No water filled up in the bin Check water flow in the evaporator The thermostat operates or it is faulty
Check if the bin thermostat has
operated and eventually change it
The defrost is not correctly effected
Blocked timer Change the timer Faulty evaporator therm ostat Change the evaporator thermostat
Sheet of ice under the evaporator
Faulty or blocked tim er Change the timer
7
ENGLISH
PROBLEM REASON SOLUTION
Faulty bin thermostat
Check and eventually change the bin thermostat
The ice makers works also when the bin is fu ll
Bin thermostat not calibrated
Check the therm ostat and eventually calibrate it
No electrical supply Check water system Blocked water valve
Check and eventually change the water valve
Faulty pressure switch
Check and eventually change the pressure s w itch
The safety therm ostat operates
Scale in the water condenser
Clean the condenser w ith apposite anti scale products
Low water level in the bin
See ” no water spraid from
spra yers” Evaporator thermostat not calibrated
Calibrate thermostat
Not standard water jets
Check that each jet sprays directly
without obstacles the center of the
copper cups The ice maker is not in the correct horizontal position
Check the feet and place in the
right horizontal position Small quantity of refrigerant in the cooling system
Repear eventula leaks and
recharge the refrigerant
The ice cubes are not complete
See also “decreasing of production” High ambient temperature and/or
small air circulation
Change place of installation of the
ice maker or change am bient
temperature Obstracted position of the machine (e.g. inside a furniture)
Change place of installation or
permit air circulation Dirty air condenser
Clean the condenser w ith
compressed a ir High water temperature
Check water temperature and
change place of installatio n Bin full of water Check drain pipe of the bin
Decreasing of production
Small quantity of refrigerant in the cooling system
Repear eventula leaks and
recharge the refrigerant The compressor is short-circuited and/or grounded
Check and change the compressor The pump is short-circuited and/or
grounded
Check and change the pump The hot gas valve is short-circuited
and/or grounded
Check and change the hot gas
valve The thermostats are grounded Check and change the thermostat Other electrical componets are short-circuited and/or grounded
Check and change the component
The circuit breaker operates
Circuit breaker differential is faulty Check and change the component
8
4
PARTS SECTION
ENGLISH
BODY
9
Pos. Description Note
21/5 22/5 25/6 28/7 30/10 44/15 50/26 75/40 100/60 130/75 160/75
1 Foamed body
K00997 K00997 K00997 K00471 K00470 K00469 K00468 K00466 K00467 K00473
2a Right angle
K00155 K00155 K00155 K00155 K00155 K00126 K00126 K00052 K00052 K00446
2b Left angle
K00704 K00704 K00704 K00704 K00704 K00703 K00703 K00702 K00702 K00706
3 Base assembly
K00803 K00803 K00803 K00154 K00154 K00123 K00123 K00550 K00550 K00549
4 Right panel
K00832 K00805 K00995 K01613 K01615 K01618 K01620 K01623 K01625 K01628
5 Left panel
K00831 K00804 K00996 K01614 K01616 K01619 K01621 K01624 K01626 K01629
6 Door
K00828 K00816 K00816 K00241 K00241 K00245 K00245 K00249 K00249 K00456
7 Front panel
K00830 K00811 K00811 K00182 K00165 K00136 K00194 K00063 K00214 K00455
8 Back grid
K00844 K00844 K00844 K00173 K00173 K00195 K00195 K00065 K00065 K00450
9 Back panel
K00810 K00810 K00810 K00178 K00163 K00134 K00191 K00059 K00211 K00448
10 Top assembly
K01369 K01393 K01651 K01658 K01658 K01659 K01659 K01656 K01656 K01657
11 Door support
K00834 K00834 K00834 K00273 K00273 K00274 K00274 K00275 K00275 K00224
12 Thermostat pocket
K00896 K00896 K00896 K00895 K00895 K00043 K00043 K00043 K00043 K00043
13 Foot
K01086 K01086 K01086 K01086 K01086 K01574 K01574 K01341 K01341 K01341
14 Bush
K01148 K01148 K01148 K01148 K01148 K01148 K01148 K01148 K01148 K01148
ENGLISH
BODY
10
ENGLISH
Pos. Description Note
21/5 22/5 25/6 28/7 30/10 44/15 50/26 75/40 100/60 130/75 160/75
1 Tank
K00800 K00800 K00800 K00149 K00149 K00144 K00144 K00045 K00045 K00300 K00300
2 Tank support
/ / / K00152 K00152 K00121 K00121 K00036 K00036 K00439 K00439
3 Evaporator support
K00817 K00817 K00817 K00151 K00151 K00120 K00120 K00041 K00041 K00320 K00320
4 Flag support assembly
K00826 K00826 K00826 K00225 K00225 K00653 K00653 K00556 K00556 K00227 K00227
5 Flag
K00008 K00008 K00008 K00008 K00008 K00008 K00008 K00008 K00008 K00008 K00008
6 Pawl
K00013 K00013 K00013 K00013 K00013 K00013 K00013 K00013 K00013 K00013 K00013
7 Suction filter
K00012 K00012 K00012 K00012 K00012 K00012 K00012 K00012 K00012 K00012 K00012
8 Suction ring
K00058 K00058 K00058 K00058 K00058 K00058 K00058 K00058 K00058 K00058 K00058
9 Suction pipe
K00823 K00823 K00823 K00185 K00142 K00142 K00198 K00072 K00218 K00218 K00218
10 Pump assembly W
K01530 K01530 K01530 K00553 K00553 K00553 K00553 K00553 K00553 K01 164 K01164
A
K01302 K01302
WATERWORKS
11
ENGLISH
11 Fan W
/ / / K01023 K01023 K01023 K01023 K01023 K01023 K01023 K01023
A
K01301 K01301
12 Inlet pipe
K00824 K00824 K00824 K00184 K00141 K00141 K00197 K00109 K00217 K00217 K00217
13 Inlet ring
K00057 K00057 K00057 K00057 K00057 K00057 K00057 K00057 K00057 K00057 K00057
14 Bar pipe
K00048 K00048 K00048 K00048 K00048 K00048 K00048 K00048 K00048 / /
15 Sprayers bar assembly
K00825 K00825 K00825 K00171 K00171 K00133 K00133 K00047 K00047 K00316 K00316
16 Sprayers
K00220 K00220 K00220 K00220 K00220 K00220 K00220 K00220 K00220 K00220 K00220
17 Plug
K00527 K00527 K00527 K00527 K00527 K00527 K00527 K00527 K00527 K00527 K00527
18 Chute
K00820 K00820 K00820 K00157 K00157 K00124 K00124 K00024 K00024 K00334 K00334
19 Fan motor assembly W
K01083 K01083 K01083 / / / / K01083 K01083 K01083 K01083
A
K01380 K01380 K01380 / / / / / / / /
20 Overflow assembly
K01317 K01317 K01317 K01317 K01317 K01317 K01317 K01317 K01317 K01317 K01317
21 Gasket
K01125 K01125 K01125 K01125 K01125 K01125 K01125 K01125 K01125 K01 125 K01 125
22 Overflow drain
K00006 K00006 K00006 K00006 K00006 K00006 K00006 K00006 K00006 K00006 K00006
23 Gasket
K00536 K00536 K00536 K00536 K00536 K00536 K00536 K00536 K00536 K00536 K00536
24 Ring nut
K01126 K01126 K01126 K01126 K01126 K01126 K01126 K01126 K01126 K01 126 K01 126
25 Overflow pipe
/ / / / K00541 K00542 K00543 K00540 K00544 K00545 K00545
26 Drain screw nut
K00004 K00004 K00004 K00004 K00004 K00004 K00004 K00004 K00004 K00004 K00004
27 Gasket
K00003 K00003 K00003 K00003 K00003 K00003 K00003 K00003 K00003 K00003 K00003
28 Drain stub pipe
K00039 K00039 K00039 K00039 K00039 K00039 K00039 K00039 K00039 K00039 K00039
29 Drain pipe
K00110 K00110 K00110 K00110 K00110 K00110 K00110 K00110 K00110 K00110 K00110
30 Nipple water outlet W
K00578 K00578 K00578 K00578 K00578 K00578 K00578 K00578 K00578 K00578 K00578
A
K00001 K00001 K00001 K00001 K00001 K00001 K00001 K00001 K00001 K00001 K00001
31 Watervalve W
K01045 K01045 K01045 K01045 K01045 K00204 K00204 K01322 K01322 K01 195 K01046
A
K01212 K01212 K01212 K01212 K01212 K01213 K01213 K01213 K01213 K01214 K01214
32 Hydrohelectrical support
K00822 K00822 K00822 K00030 K00030 K00030 K00030 K01146 K01146 K01146 K01146
33 Cable
K01324 K01324 K01324 K01324 K01324 K01324 K01324 K01324 K01324 K01324 K01324
34 Wye
/ / / / / / / K00010 K00010 K00010 K00010
35 Valve support W
//////////K00330
36 Nipple W
//////////K01160
37 Pressure valve W
//////////K00497
38 Union tee
/ / / / / / / / / K00230 K00230
39 Bar pipe
/ / / / / / / / / K00445 K00445
40 Bar pipe
/ / / / / / / / / K00444 K00444
41 Pipe
/ / / / / / / / / K00311 K00311
Pos. Description Note
21/5 22/5 25/6 28/7 30/10 44/15 50/26 75/40 100/60 130/75 160/75
WATERWORKS
W: WATER A: AIR
12
ENGLISH
COOLING SYSTEM
13
1 Evaporator
K00145 K00145 K00145 K00145 K00139 K00139 K00138 K00138 K00332 K00332
2 Hot gas valve
K01531 K01531 K01531 K01531 K01531 K01531 K01531 K01531 K01532 K01532
3 Compressor
K00200 K00200 K00200 K01186 K00202 K00085 K00085 K00206 K00475 K00476
4 Water condenser ass. W
K00278 K00278 K00278 K00112 K00147 K00147 K00017 K00017 K00333 K00333
5 Condenser support W
K00279 K00279 K00279 K00113 K00146 K00146 K00029 K00029 K00335 K00335
6 Gas filter
K00199 K00199 K00199 K00199 K00199 K00199 K00081 K00081 K00478 K00478
7 Safety thermostat W
K00076 K00076 K00076 K00076 K00076 K00076 K00076 K00076 K00076 K00076
8 Electric panel
K00808 K00808 K00808 K00119 K00119 K00119 K00049 K00049 K00049 K00049
9 On-off switch
K00082 K00082 K00082 K00082 K00082 K00082 K00082 K00082 K00082 K00082
10 Timer
K00075 K00075 K00075 K00075 K00075 K00075 K00075 K00075 K00075 K00257
11 Evaporator thermostat
K00080 K00080 K00080 K00080 K00080 K00080 K00080 K00080 K00080 K00080
12 Bin thermostat
K00079 K00079 K00079 K00079 K00079 K00079 K00079 K00079 K00079 K00079
13 Pressure switch
K00077 K00077 K00077 K00077 K00077 K00077 K00077 K00077 K00077 K00077
14 Contactor
/ / / / / / / / / K00500
15 Evaporator cover
K00150 K00150 K00150 K00150 K00118 K00118 K00069 K00069 K00226 K00226
16 Air condenser ass. A
K01223 K01223 K01223 K01665 K01225 K01225 K01313 K01314 K01314 K01315
Pos. Description Note
21/5 22/5 25/6 28/7 30/10 44/15 50/26 75/40 100/60 130/75 160/75
W: WA TER A: AIR
ENGLISH
COOLING SYSTEM
14
5
ATTACHMENTS
ENGLISH
USER MANUAL
15
ENGLISH
USER MANUAL
16
ENGLISH
USER MANUAL
17
ENGLISH
USER MANUAL
18
ENGLISH
USER MANUAL
19
ENGLISH
USER MANUAL
20
ENGLISH
USER MANUAL
21
ENGLISH
USER MANUAL
22
ENGLISH
USER MANUAL
23
ENGLISH
BIN THERMOST AT REGULA TION
24
ENGLISH
EVAPORA T OR THERMOSTA T ADJUSTMENT
25
ENGLISH
TIMER
26
WA TER SUPPL Y AND ELECTRICAL
ENGLISH
27
ENGLISH
ELECTRICAL P ANNEL (KP 21)
28
ENGLISH
ELECTRICAL P ANNEL (FROM KP28 TO KP50)
29
ENGLISH
ELECTRICAL P ANNEL (FROM KP75 TO KP130)
30
ENGLISH
ELECTRICAL P ANNEL (KP160)
31
ENGLISH
NOTES
Via Fusina, 1/A - 31033
Castelfranco Veneto Treviso - Italy
T el. +39 0423 724061 - Fax +39 0423 743222
E-mail: info@kastelice.com
KASTEL s.r .l.
Rev .01-Ed.03/05
Loading...