Kason 1967-A2 Installation Instructions Manual

Page 1
INSTALLATION INSTRUCTIONS
1967-A2
Part Number: 11967*
Caution: Risk of Electrical Shock
Turn off breaker at all energized switches before making any electrical connections.
Warning This item may contain chemicals known to cause cancer or reproductive harm in the state of California. www.p65warnings.ca.gov
OEM INSTALLATION
• Requires 2 standard 2-1/8” deep junction boxes. One for battery and one for Temperature Display unit. Separate conduit required for “LINE” and low voltage wiring
• Run wiring for probe from device box to refrigerated space. Seal around wires to prevent moisture from entering device box
• Run battery cable to battery junction box. This allows battery to be replaced
• Run power wiring 14 AWG min., crimp and secure 1/4 spade insulated female connectors to all wires. Follow all manufacturing recommendations for installation of connectors
• All wiring must comply with local code
• Test display by temporarily applying a 9 volt battery to the battery connector
• Display will cycle through a test program and show temperature. Display will flash temperature. Remove battery for shipping
ERRORS AND TROUBLESHOOTING
• Display reads “HOT”, “OFF”or “- - -”: Connect temperature probe or replace probe.
• Temperature doesn’t change fast enough: The temperature sensor is encapsulated in epoxy and wrapped in a tube. This encapsulation is designed to simulate product mass and not be effected by door opening or defrost cycling.
• Low Battery or “LoBat” is blinking: The battery is not installed or the battery charge is too low to allow unit to operate. Replace battery
• Power goes off and display goes blank: The battery is not installed or the battery charge is too low to allow unit to operate. Replace battery
DESIGN CRITERIA
• Electrical Rating
– Voltage: 120 VAC (240 VAC special order) – Load: 20 AMP resistive/general use – Temperature sensing and display range
-40°F [-40°C] to 104°F [40°C] – Resolution: 1° +/- .5°C – Mounting: Inside cooler, outside cooler,
and outside freezer 32°F [0°C] to 72°F [22°C]
Part No. Description
119670000A2 Temp Display w/ Kason (120 VAC)
FIELD WIRING
• Once the unit has been wired using supplied wiring schematic, connect the 9 volt battery. Connect power to circuit
119670000A2240 Temp Display w/ Switch (240 VAC)
91967000942 Temperature Probe, 72 in [6 ft]
919670094224000 Temperature Probe, 240 in [20 ft]
BATTERY
• Never place 9 V battery in freezer
• Never use lithium ion batteries
OPERATION
• Light Control: Press rocker switch to turn lights ON
• Unit Change: To change temperature units from °F to °C, install the small black jumper on the back of unit. This is found in the bag with mounting screws
• Battery Voltage Monitoring: The far right decimal point will flash if the battery voltage gets too low to operate the unit properly. In battery-only mode, the display will turn on and off to conserve battery life
© 2019 Kason Industries, Inc. IS-1967-A2 0919 kasonind.com | 1.800.935.2766 | PAGE 1
Page 2
INSTALLATION INSTRUCTIONS
1967-A2
Part Number: 11967*
© 2019 Kason Industries, Inc. IS-1967-A2 0919 kasonind.com | 1.800.935.2766 | PAGE 2
Page 3
Temperature display needs constant AC power. Always pull power to display.
INSTALLATION INSTRUCTIONS
1967-A2
Part Number: 11967*
© 2019 Kason Industries, Inc. IS-1967-A2 0919 kasonind.com | 1.800.935.2766 | PAGE 3