Kason 1832LT0004 User Manual

WALL THICKNESS
TED VENT
6-1/4”
1832LT LOW TEMPERATURE VENTILATOR
HEA
4-5/8”
117.5mm
158.8mm
WALK-IN
DIA.
Model No. Item Wall Thickness Quantity Per Carton Weight Per Carton
1832SA0001 Square Outside Louver, Aluminum
1832SS0001 Square Outside Louver, Stainless Steel
1832LT8630117 Inside Louver Replacement Kit for 1832LT Ventilator
Contact Kason Representative
AIR FLOW CHART AND QUANTITY SELECTOR ON FOLLOWING PAGE
KASON INDUSTRIES, INC.* 57 AMLAJACK BLVD.*NEWNAN*GEORGIA*30265 1.800.93KASON WWW.KASONIND.COM
© 2009 Kason Industries, Inc.
1832LT LOW TEMPERATURE VENTILATOR
Comprehensive performance testing has shown that Kason 1832LT ventilators have better air flow and frost resistance than competitively sized units.
WALK-IN
LT
1832LT VENTILATOR QUANTITY SELECTOR
Number of Ventilators Required
Volume of Cooler or
Freezer
3
ft
(m3)
Cooler
o
F (5.6o C) Temp
10
Change / 20 min.
o
(0.5
F/min)
Freezer
o
30
F (16.8o C) Temp
Change / 20 min.
o
(1.5
F/min)
4,000 (113) 1 1
6,000 (170) 1 2
8,000 (226) 1 2
12,000 (340) 1 3
16,000 (453) 2 4
20,000 (566) 2 See Note 3
24,000 (679) 2 See Note 3
NOTES: (1) The table above should be used as a general guideline only. Kason does not guarantee these numbers, as many factors beyond those as­sumed can affect the amount of ventilation required in a refrigerated space. Some of these factors include, but are not limited to: the number of doors in the enclosure, air-tightness of the enclosure, refrigeration load (how quickly the temperature drops), strength of panel construction, etc. (2) Vent quantities are calculated based on actual measured flow rates at an assumed allowable pressure differential for given temperature change rate. Example: 1832 = 14 ft
3
/min @ .6inH2O pressure. (3) Specify model 1832LT for boxes this size and larger if box temperature is below -20F. For higher temperature boxes, use model 1845.
KASON INDUSTRIES, INC.* 57 AMLAJACK BLVD.*NEWNAN*GEORGIA*30265 1.800.93KASON WWW.KASONIND.COM
© 2009 Kason Industries, Inc.