K-array Redline KR200S User Manual

Page 1
ENGLISH
USER'S MANUAL
REV. A
USER'S MANUAL
K-array is the new voice that sings aloud, "outside the choir", and whose performance is better than any other products.
Born on-the-road, in the PA world, where you get no discount, you have to give your best as fast as you can, often with a "compressed" budget, K-Array systems have been designed to give precise answers to precise needs.
Driven by new generation digital engines, with power/dimension/weight ratios that are ten times better than any other professional products, K-arrays can deliver the full spectrum of musical styles with clarity, power, punch, intelligibility and evenness across both volume levels and the frequency spectrum. These systems can be remotely controlled and come with a sophisticated on-board software, allowing the user to shape their performance to taste and needs. Inside K-array systems you will find something that only we can offer: the best in technology, proudly conceived, designed and produced in Italy. If they were cars, they would be Ferrari. Don't agree to pay for a simple brand, claim performance, and don't believe those who maintain that these products are only for few people, the only truth is that K-array systems are uni que, but affor dabl e and w ithi n everybody's reach!
HP Sound Equipment s.r.l.
KR200S
Page 2
SYMBOLS
1. SAFETY INSTRUCTIONS
!
This symbol, wher ever it ap pears , ale rts y ou to
impor ta nt ope ratin g and mai ntena nce istru ct ions in
the ac compa nying lit erature . Re ad the manual !
Dange ro us voltag es: risck of electr ic shock.
For in fo rmati on abo ut the dispo sal of Was te Electric al
and El ectro nic Equipme nt (WEEE) , pl ea se refer to the
websi te at
www.sc an ning. datal ogic.co m
This s ymbol alerts the u ser to the prese nc e of
rec om m end a t ions ab ou t pro du c t's use an d
maint en ance.
CAUTION
!
!
To reduce t he risk of el ec tric shock, d isconnect the a mp lifier from t he AC mains be fo re installi ng audio cable.
Reconnect th e power cord on ly aft er making all s ignal conn ec tions.
Connect the amplifier to a t wo -pole, thr ee wire groun di ng mains receptacle . T he receptacle must b e connected to
a fu se o r circ ui t br eaker. Connection to any other type of receptacle poses a shock hazard and may violate local
electrical c odes.
Do not i nstall the amplifier in wet or h umid locations w it hout using weather p rotection.
Do not all ow water o r any foreign object t o get inside the amplifier. Do n ot put objects con taining l iquid o n, or near,
the unit.
To reduce t he risk of ove rh eating the amplifie r, avoid exposin g it to d irect s un light. Do not install t he unit nea r heat
emitting a pp liances, such as a ro om heater or st ove.
No nake d flame sources s uc h like li gh ted candle s should be pl aced on the d ev ice.
The ampl if ier sho ul d be placed so th at its location does no t int er fere wi th its proper ventilation . For example, the
appliance s hould not be situa te d on a bed, c arpet, or similar su rface that m ay create an obstacl e for the ventilatio n
openings.
ENGLISH
USER'S MANUAL
pag. 02
Page 3
2. INTRODUCTION
The KR 200S i s a high perform an ce u lt ra-slim powered two way system designed for small to medium wavefront
systems, i n both mobile and ins ta lled applicatio ns .
The KR200S inc lu des two KR200 s at ellites an d 2 KL18ma powere d subwoofers .
KL18ma feature s a 1600 w att 18" drive unit with n eo dymium magne t str ucture and s uspension engineered for
maximum linear excu rs ion. Its ultra-lig ht reflex cabinet is fi tt ed with two pocket handles and on e 3 5m m p ole
mounting p oi nt for easy installa ti on with every s atellite s pe aker on it.
The KR2 00 S feature s a lin e array of 32x2" high efficien cy neodymiu m magnet drivers enclosed in an ul tra-strong
chassis, t o ensure high res is tance and d urability in the har dest working conditio ns .
The K R200S thanks to true line array tech no logies and powerful DSP syst em , a ch ieve outstandin g p ow er a nd
coherence th roughout the intended cov er age allowi ng a wide dynamic range a nd a faithful r ep roduction of sou nd.
All th e compon en ts are
The
designed by K- ar ray R& D depart me nt and c us tom ma de under K -array c ontrol q uality
system.
3. VOLTAGE REQUIREMENTS
KA 10 operates s afely a nd w it hout audio disc on tinuity i f th e AC v ol tage stays with in e ither of two operat in g
windows: 95-125 (voltage sel ec tor on 115 V) or 195-25 0 V (voltage se le ctor on 230 V), at 50 or 60 Hz.
115-230
Conne ct ing a 115 V syste m on a 23 0V AC Powe r c au ses heavy
damag es to the devi ce and serious risk for use rs .
CAUTIO N
!
The devic e is defaul t set to be connected to 2 30 V AC Powe r. To u se the de vi ce on a 115 V AC Power you nee d,
before connecting it, to m ove the vol ta ge sel ec tor's cover, just loosening the two screws, and to choo se the correc t
use volta ge by the red sw it ch. Be sure th at both voltage se t on th e selector and A C Power have the same value .
Always clo se the v oltage sel ec tor's c over before connecti ng the d evice t o AC Power. Cha ng e t he label that p oints
out the correc t voltage i n use.
ENGLISH
pag. 03
USER'S MANUAL
Page 4
PRESET
keep pressed
for preset lock
INPUT
PARALLEL
OUT
INPUT
(balanced)
GROUND
LIFT
ON
LIMIT
LINK
LINK
(parallel)
POWER
ON
ATTENTION!:
READ MANUAL FOR
CORRECT
PRESET SELECTION
1+ POSITIVE OUT 1- NEGATIVE OUT 2+ N.C. 2- N.C.
REMOTE
DSP
POWER
OUTPUT
ANALOG
POWER SUPPLY
INPUT
PAD
dB
0
0.5 3
4
5
6
9
12
18
35
0
0
RS485
ADDRESS
MADE IN ITALY
WARNINGS:
To ensure correct operation,
allow at least
20 cm clearance from
back surface and correct ventilation. To reduce risk of electric shockdo not remove
cover. No operatoror serviceable
parts inside. Refer servicing to
qualified personnel. To reduce the
risk of fire or electric shock do
not expose this appliance to
rain or moisture.
CAUTION
RISK OF ELECTRICAL SHOCK
DO NOT OPEN!
DO NOT EXPOSE
TO RAIN OR MOISTURE!
ATTENTION
RISQUE DE CHOC ELECTRIQUE
NE PAS ENLEVER!
is a product of
viale Roma 7/i, 50037 S.Piero a Sieve Firenze ITALY Tel + 39 055 8487222
HP Sound Equipment srl
ID12 PRESET
I
0
PUSH
Balanced XLR In \ Out parallel
RS485 connection for remote control (don't connect to LAN port!)
Ground lift switch
Input pad level
Pr es et change but to n Keep it pressed 10sec. to store presetas default
I D n u m b e r f o r remote control
S p e akon po we r output. To use with KR200 sa te ll ite or wit h K L 1 8 p a s s i v e subwoofer
PowerCon Input
PowerCon parallel Output
(max 14 A)
Preset loaded
ENGLISH
pag. 04
4. AMPLIFIER PANEL
USER'S MANUAL
Page 5
9 Kg
20 Kg
200 cm
100 cm
46.5 cm
46.5 cm
58.5 cm
7 cm
KR200
KL18ma
Open and lock the KR200 satellite before installing onthe KL18ma.
Warning
Pay attention when closing the KR200 satellite, do it slowly and watch your hands!
ENGLISH
pag. 05
5. PHYSICAL
USER'S MANUAL
Page 6
To get higher SPL and horizontal directivity, is
possible to combine two KR200 columns using the
machanical parts fitted oneach speaker.
Assembly Manual
System 1
System 2
2 x KR200
SX DX
2 x KL18ma
2 x KR200
2 x KL18ma
Unscrew the four screws that
fix the high steel brac ket (by
a 2.5mm allen key ), then
remove it.
Combine two KR2 00 by the
t o p u s i n g o n e o f t he
disassembl ed brac kets.
Disassembl e the junctio n of the lower suppor t.
Combine t he two
KR200 by the bottom
u s i ng th e o t he r
disasse mble d steel
bracket. Fix it only by
the mo re e xtern al
h o l es . T h e f o u r
cen t ra l p oi nt s o f
attachment (A ) m ust
be left free .
Ass emble th e jun ction
sopport with the middle of
the brac ket, by the four
free cent ral points of
att achm ent. Use other
four scr ews in the fou r
holes on the bottom of the
speaker.
M3x10
M3x10
A
M3x10
ENGLISH
pag. 06
6. SYSTEM'S EXTENSION
USER'S MANUAL
Page 7
HP Sound E quipment s.r.l. - www.k-array.com
Viale R oma 7/i 50037 Sa n Piero a Sieve (Firenze) Ital y - tel +39 055 8487222 fax e-mail: info@k-array.com+39 055 8487238
7. TECHNICAL DATA
ENGLISH
pag. 07
USER 'S MANUAL
horizontal
500 Hz
250 Hz
8 KHz
4 KHz
1 KHz
500 Hz
250 Hz
8 KHz
4 KHz
1 KHz
vertical
KR200S
Acoustics
Speakers power handling 800(sub) + 500(sat) w
(EAS)
Max power 1200(sub) + 1200(sat) w
1
Impedance 8Ω(sub)+16Ω(sat)
Frequency range 30Hz - 19 KHz +/- 3dB (preset dependent)
SPL 1W/1mt 97 dB (sub) 101 dB (sat)
2
Maximum SPL 127dB continuous - 133 dB peak
Coverage
Horizontal 100°
Vertical
Crossover
Type DSP controlled
Frequency 150 Hz minimum (preset dependent)
Transducers
Low frequency 1 x 18” Neodymium speakers with 3” voice coil
High frequency 32 x 2” Neodymium speakers with 0,75” voice coil
Audio Input
Connectors male + female parallel 3-pin balanced XLR
Wiring Pin1 = ground - Pin2 = hot - Pin3 = cold
Audio powered Output
Connector Female Speakon
Wiring Pin1+= CH1+ Pin1= CH1- Pin2+= N.C. Pin2= N.C.
Remote control Input
Connectors 1 x female 8 poles RJ45
Power Input
Connectors 2 x PowerCon IN/OUT
Type 1 modules class D - DSP controlled
Subwoofer power 1000 Watt
3
@8Ω
Satellite power output 1000 Watt
3
@8Ω
Protection Dynamic limiter, over current, over temp, short circuits
AC power
Operating range 210 - 240 Vac 50Hz (Default)
100 - 120 Vac 60Hz (Selectable)
I. nom 5.5 A / 115 Vac - 2.9 A / 230 Vac
Minimum operation voltage 95 Vac - 195 Vac
Maximum operation voltage 125 Vac - 205 Vac
Max continuos and
burst current
Default 6A(>10 sec) - 12A (<1 sec)
Selectable 10A(>10 sec) - 20A (<1sec)
Physical
Dimensions
KL18ma: 46.5 x 47.5 x 61 cm (18.31”x 18.70” x 24.02”)
KR200: 5.7 x 222.5 x 7.4 cm (2.24”x 87.60” x 2.91”)
Weight KL18ma: 25.8 Kg (56.88 lbs) KR200: 8.2 Kg (18.08 lbs)
90°
120° 60°
30°
-30°
-60°
150°
-90°
180°
-150°
-120°
front
back
90°
120° 60°
30°
-30°
-60°
150°
-90°
180°
-150°
-120°
front
back
DISPERSION GRAPHS
Notes for data
1. Maximum RMS applicable power for a musical signal, the reference signal is the one proposed by EIAJ standard.
2. Measured @4 mt then scaled @1 mt
nominal load impedance.
New materials and design are introduced into existing products without previous notice. Present systems may differ in some respects from those presented in this brochure.
Page 8
Cl ear Sm oot h
Ba ck
Ton y
HP 60
Di sco Liv e
Da rk
Cl -3 (C le ar - 3 dB Su b)
Cl -6 (C le ar - 6 dB Su b)
To- 3 (Ton y -3 dB S ub)
To- 6 (Ton y -6 dB S ub)
Li -3 (L iv e -3 dB Su b)
Li -6 (L iv e -6 dB Su b)
ENGLISH
pag. 08
8. PRESETS
USER'S MANUAL
Page 9
ENGLISH
pag. 09
NOTES
USER'S MANUAL
Page 10
NOTES
www.k-array.com
by
HP Sound Equipment s.r.l
.
Viale Roma 7/i
50037 San Piero a Sieve (Firenze)
Italy
tel +39 055 8487222 fax +39 055 8487238
e-mail: info@k-array.com
K
array
The contents of this manual are fornished for informational purpose
only. Hp Sound Equipment s.r.l. assumes no responsability for any
errors or inaccuracies that may appear in this manual.
Hp Sound Equipment s.r.l. reserves the right to make modifications
without prior notice.
USER'S MANUAL
REV. A
Loading...