12. TOUCH SCREEN FUNCTIONS 15
HOME PAGE 15
LEVELS 15
MATRIX 15
DEL AY 16
CONFIGURATION 16
PRESET 17
INFO 17
13. REMOTE CONTROL SOFTWARE 17
14. KA-POT1 ACCESSORY 18
14.1 CHANNEL LEVELS ASSIGNMENT 18
14.2 ASSEMBLING AND WIRING 19
15. SERVICE 21
16. SPECIFICATIONS 22
DECLARATIONS OF CONFORMITY 23
3
PRELIMINARY
KA24/KA84
4
PRELIMINARY
KA24/KA84
SYMBOLS
K-array declares that this device is in compliance with applicable CE
standards and regulations. Before putting the device into operation, please
observe the respective country-specific regulations!
WEEE
Please dispose of this product at the end of its operational lifetime by bringing
it to your local collection point or recycling center for such equipment.
This symbol alerts the user to the presence of recommendations about the
product’s use and maintenance.
Warning! Dangerous voltages: RISK of electric shock.
Terminals marked with this symbol are HAZARDOUS LIVE and the external
wiring connected to these terminals requires installation by a qualified
professional or the use of ready-made leads or cords.
This symbol alerts the user to the presence of recommendations about
product’s use and maintenance.
This device complies with Restriction of Hazardous Substances Directive.
5
PRELIMINARY
KA24/KA84
1. INTRODUCTION
The K-array KA line of power amplifiers are comprised of KA24 and KA84. The KA24 has 4 channels
per 500W on 4Ω and the KA84 has 4 channels per 2000W on 4Ω. Each model has 4 fully independent
and configurable channels. The integrated DSP offers EQ, Matrix, Levels, Delays and Limiter functions
on every channel, to avoid the need of external additional processors. The front panel has an
easy-to-use touchscreen that gives access to all the basic functions for quick setup and corrections.
The KA24 and KA84 can be used as a mixer for fixed installations thanks to the microphone and
Phantom power options available on every analog IN. 2 GPIO ports give easy external analog controls
using K-array accessories.
An on-board K-array speaker preset library gives an optimal and easy configuration for endless
combinations. All DSP functions are remote controlled via the K-framework software over RS485 (3-pin
XLR) or integrated USB connector.
Both amplifiers are built into a 2U light weight aluminium chassis and come with a kit of removable
rack adapters and four rubber pads for flat surfaces.
KA amplifiers feature optical limiters, and protection against over heating, over current and short
circuits.
All KA components are designed by the K-array R&D department and custom made under the K-array
quality control system.
2. KEY FEATURES
• 2000 W or 8000 W in just 2 rack units
• 4 analog IN and 2 AES-EBU IN to 4 fully
configurable OUT
• 2 GPIO for external analog controls
• Mix sensitivity and phantom power is available
in all 4 analogue inputs.
• Integrated DSP with processing, matrix and
delays
• On-board touch screen for easy access functions
• K-array loudspeakers presets already on-board
• RS485 and USB connectivity for remote control
3. APPLICATIONS
• Theatrical sound reinforcement
• Concert halls, clubs, house of worship
• Exhibit audio for museum displays
• Cinema and installed AV systems
• Touring PA and Monitoring
6
PRELIMINARY
KA24/KA84
4. SAFETY INFORMATION
Read these instructions - Keep these instructions - Heed all warnings
Warning. Failure to follow these safety instructions could result in fire,
shock or other injury or damage to the device or other property.
This symbol alerts the user to the presence of
recommendations about the product’s use and
maintenance.
The lighting flash with arrowhead symbol within
an equilateral triangle is intended to alert the
user to the presence of uninsulated, dangerous
voltage within the product enclosure that may
be of magnitude to constitute a risk of electrical
shock.
IMPORTANT SAFETY INSTRUCTIONS
• Read these instructions.
• Keep this instructions.
• Heed all warnings.
• Follow all instructions.
• Do not use this apparatus near water.
• Clean only with dry cloth.
• Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
• Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat.
• Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two
blades with one wider than the other. A grounding type plug has two blades and a third grounding prong.
The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your
outlet, consult an electrician for replacement of the obsolete outlet.
• Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles,
and the point where they exit from the apparatus.
• Only use attachments/accessories specified by the manufacturer.
• Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the
apparatus.
• When a cart is used, use caution when moving the cart/apparatus combination to avoid
injury from tip-over.
• Unplug this apparatus during lightning storms or when unused for long periods of time.
• Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been
damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects
have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate
normally, or has been dropped.
7
PRELIMINARY
KA24/KA84
WARNING
• Since the device is a CLASS I apparatus, it must be only connected to an AC three-wire grounding outlet.
If your outlet isn’t grounded, contact a licensed electrician to replace it with a property grounded outlet.
• To reduce the risk of electric shock, disconnect the amplifier from the AC mains before installing audio
cable. Reconnect the power cord only after making all signal connections. Do not use the product if the
power cord is broken or frayed. Protect the power cord from being walked upon or pinched.
• To completely disconnect this apparatus from the ac mains, disconnect the power supply cord plug
from the ac receptacle.
• Voltage requirement. Make sure that the supplied voltage stays within the specified range. Verify that
your mains connection satisfies the power ratings of the device.
• Only connect the power supply to an appropriate power outlet.
• Do not install the amplifier in wet or humid locations without using weather protection.
• TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do not expose this apparatus to rain or moisture
and objects filled with liquids, such as vases, should not be placed on this apparatus.
• The main plug of the power supply cord shall remain readily accessible.
CAUTION
• Choking Hazards. This device contains small parts, which may present a choking hazard to small
children. Keep the device and its accessories away from small children.
• It is important that loudspeaker systems are used in a safe manner.
• Do not make repairs yourself. Caution, risk of electric shock. Do not open the device, it contains
potentially hazardous voltage. Never attempt to disassemble, repair or modify the system yourself.
Disassembling the unit may cause damage that is not covered under the warranty. The device contains
no user-serviceable parts. Repairs should only be performed by factory trained service personnel. Do not
plug the power cord in if you suspect that your device needs service or repair.
5. UNPACKING
Each K-array amplifier is built to the highest
standard and thoroughly inspected before leaving
the factory. Upon arrival, carefully inspect the
shipping carton, then examine and test your new
amplifier. If you find any damage, immediately
notify the shipping company. Only the consignee
may institute a claim procedure regarding the
system’s electronic equipment.
6. INCLUDED ACCESSORIES
• Power cable 3 m
• USB cable 1.8 m
• Rubber pads for flat surfaces installation
• Rack brackets
8
PRELIMINARY
KA24/KA84
7. P H Y S I C A L
480 mm (18.9")
430 mm (16.9")
94.9 mm (3.7")
304.8 mm (12.0")
294.8mm (11.6")
304.8 mm (12.0")
Weight
KA24: 5.5 Kg (12.12 lb)
KA84: 6.1 Kg (13.45 lb)
9
PRELIMINARY
KA24/KA84
8. INSTALLATION
KA24 and KA84 are two rack units high (2U) and can be mounted in an EIA-standard 19’’ rack using
two rack adapters (included). In case of istallation on a flat surface, use the four rubber pads included.
To maintain a low and even operating temperature, the amplifier contains two fans on the right side.
The figure below shows the air flow:
10
WARNING
For effective cooling, do not obstruct the ventilation openings.
PRELIMINARY
KA24/KA84
9. AC POWER
KA24 and KA84 operate safely and without audio discontinuity if the AC voltage stays within an operating
range of 90 V to 264 V (nominal range: 100-240 V) at 50 or 60 Hz. Please verify that your AC main
connections are capable of satisfying the power rating for the device.
CAUTION. Do not connect the system to AC power mains exceeding 265 V. Doing
so will cause significant damage to the device and create serious risk for users!
10. FRONT PANEL
21
1. TOUCH SCREEN Control panel. Provides access to the main functions of the DSP on board (see Section 12)
2. POWER SWITCH. Turns the amplifier on and off.
11. BACK PANEL
1011121314
3
24
20
CH 5 - 6
16
6789
22
5
4
2728
11
26
2125
1718
19
1516
23
PRELIMINARY
KA24/KA84
CH 5 - 6
11.1 POWER SUPPLY
345
11.2 AUDIO CONNECTIONS
3. AC INPUT. PowerCon for AC power.
4. AC LINK. PowerCon ouput for feeding AC mains
power to additional K-array components with a
powercon AC input socket.
5. POWER ON LED. Indicates the amplifier is ON.
6. CH 1 MIC/LINE INPUT. XLR analog input, with
selectable sensitivity for Mic (-30 dBu) or Line (+4 dBu).
CH 5 - 6
7. CH 2 MIC/LINE INPUT. XLR analog input, with
selectable sensitivity for Mic (-30 dBu) or Line (+4 dBu).
8. CH 3 MIC/LINE INPUT. XLR analog input, with
selectable sensitivity for Mic (-30 dBu) or Line (+4 dBu).
9. CH 4 MIC/LINE INPUT. XLR analog input, with
selectable sensitivity for Mic (-30 dBu) or Line (+4 dBu).
10. CH 1 MIC/LINE SWITCH. Selects CH 1 input
17181921
sensitivity for Mic (pressed) or Line (depressed) level.
11. CH 2 MIC/LINE SWITCH. Selects CH 2 input sensitivity for Mic (pressed) or Line (depressed) level.
12. CH 3 MIC/LINE SWITCH. Selects CH 3 input sensitivity for Mic (pressed) or Line (depressed) level.
13. CH 4 MIC/LINE SWITCH. Selects CH 4 input sensitivity for Mic (pressed) or Line (depressed) level.
14. PHANTOM POWER SWITCH. Turns phantom power (48 V) on (pressed) / off (depressed) on CH 1,
CH 2, CH 3, CH 4 inputs (only for channels with MIC/LINE SWITCH pressed).
15. CH 1 PARALLEL OUT. XLR parallel output, providing a direct signal from the CH 1 Input. This output
cannot be processed or controlled via the K-Framework software.
16. CH 2 PARALLEL OUT. XLR parallel output, providing a direct signal from the CH 2 Input. This output
cannot be processed or controlled via the K-Framework software.
17. CH 3 PARALLEL OUT. XLR parallel output, providing a direct signal from the CH 3 Input. This output
cannot be processed or controlled via the K-Framework software.
18. CH 4 PARALLEL OUT OR DSP OUT. This XLR connector provides a direct signal from the CH 4 Input
when the switch 19 is depressed. In that case, this output cannot be processed or controlled via the
K-Framework software. Otherwise, when the switch 19 is pressed, this XLR acts as an auxiliary XLR
balanced output, controlled via the K-Framework software. Users can select the signal routed to this
output and manage its amplitude and EQ individually.
12
PRELIMINARY
KA24/KA84
19. CH 4 LINK OUT/DSP OUT SWITCH. Press the switch to use output 18 as an auxiliary XLR balanced output
controlled via the K-Framework software.
20. CH 5/6 AES/EBU INPUT. XLR input connector for two-channel AES/EBU digital audio, accepting sample
rates from 32 kHz – 96 kHz.
21. CH 5/6 AES/EBU OUTPUT. XLR output, providing two-channel digital audio from ch 5/6 AES/EBU input,
at a sample rate of 48 kHz.
22. POWER OUT A. Speakon output to drive passive speakers. 1+/1- provides OUT A1, 2+/2- provides OUT
A2.
23. POWER OUT B. Speakon output to power passive speakers. 1+/1- provides OUT B1, 2+/2- provides OUT B2.
11.3 REMOTE CONTROL
24
CH 5 - 6
SPEAKON OUT A
2+
2-
Speakon wiring diagram
SPEAKON OUT B
2+
1-
2-
1+
1-
1+
24. REMOTE RS485 LINK INPUT. XLR input for
connecting the amplifier from another RS485
device in a K-Framework network. RS485 Link
Input can also be used to connect a computer
running the K-Framework software (requires
K-USB USB-to-RS485 adapter).
25. REMOTE RS485 LINK OUTPUT. XLR output
for connecting additional RS485 devices in a
K-Framework network.
26. REMOTE USB Input. Connects a computer running the K-Framework software, for remote control of
the amplifier. Users can manage an entire network of RS485 devices with one PC connected via USB.
27. EXTENSION CONNECTOR. Multi-pin connector for various K-array extension modules, for wireless
control and audio transmission, memory extension, digital signal encoding and audio reproduction.
28. KA-POT1 CONNECTOR. These two analog GPIO ports allow the user to control same amplifier’s
parameters using the K-POT1 accessory. See Section 14 for further information about these feature.
13
PRELIMINARY
KA24/KA84
CH 5 - 6
CH 5 - 6
CH 5 - 6
USB connection from a PC
RS485 XLR LINK
RS485 XLR LINK
RS485 network
Next device in the K-framework network
14
PRELIMINARY
KA24/KA84
12. TOUCH SCREEN FUNCTIONS
The main functions of the onboard DSP can be managed with the integrated touch screen. Functions are
grouped into six pages, shown as icons on the Home page.
HO ME PAGE
To reach the Home page from any other page,
touch the Home button.
LEVELS
MAT R I X
The Levels page allows users to independently manage
the amplitude of all the four input channels and all the
four output channels.
Click the arrow button on the top right corner to switch
between Input levels page and Output levels page.
The Matrix page allow users to manage the routing of the
four input channels to the four output channels.
15
PRELIMINARY
KA24/KA84
DEL AY
The Delay page allows users to independently set the
delays for the four output channels (up to 3.5 mt) and for
Channel 3 and Channel 4 input channels (up to 114 mt).
Pressing on a delay value, users can set the delay in ms
or in mt. Press the OK button to return to the Delay page.
CONFIGURATION
Before connecting the speakers to the amplifier, follow
the instructions below.
Warning. Failure to follow these instructions
could result in serious damage to the
speakers connected to the amplifier!
Go to the Configuration page and press the SETUP
button Insert the model and the number of speakers
connected to Output A1. Press the arrow button on the
top right corner.
Insert the model and the number of speakers you
want to match to the previous ones. For example if you
have two KP102 mid-high arrays connected to an A1
output and a KMT21P sub connected to another output
(or to another amplifier) select KMT21P to the A1 Out
Match page and the DSP will compute automatically the
crossover setting to obtain a perfect match between the
speakers. Press the arrow button on the top right corner.
Repeat step 2 and 3 for all other outputs. At the and
you will return to the main Configuration page. Press
APPLY to load all settings. The DSP will automatically
adjust the output gain and the crossover on each output
channel to match the requirement for the speakers
connected.
16
Warning. If you are using speakers with selectable impedance, pay
attention to set the value indicated in the Configuration page!
PRELIMINARY
KA24/KA84
PRESET
The Preset page allows users to load presets stored
on-board.
INFO
The Info page contains information about the
current software and firmware, and the Board ID
of the amplifier. The Board ID is automatically
assigned to the amplifier unit when connected to a
K-Framework network.
13. REMOTE CONTROL SOFTWARE
All amplifier functions, including signal routing, output configuration, channel equalization and delay can
be controlled via K-Framework software.
To download your free K-Framework software and K-Framework User Guide, please navigate to the
K-array “K-Framework” page located at http://www.k-array.com/framework
17
PRELIMINARY
KA24/KA84
14. KA-POT1 ACCESSORY
KA-POT1 allows users to control input channels and output channels levels with a potentiometer installed
in a standard box for switches. It is possible to connect up to two independent KA-POT1 to each amplifier
in order to control two independent levels.
14.1 CHANNEL LEVELS ASSIGNMENT
To assign each KA-POT1 an amplifier parameter, connect a computer running the K-framemork
software and follow the instruction you find in the K-framework manual. As shown in the window
below, users can assign each KA-POT1 one or more channel levels. In the example below, the first
KA-POT1 controls all input channel volumes and the second controls all output channel volumes.
18
PRELIMINARY
KA24/KA84
14.2 ASSEMBLING AND WIRING
The KA-POT1 pack is composed of:
PCB with potentiometer
2 x screws M3X6
2 x 4-pin connector plugs
Drilling jig
Ø7
Ø4
KA-POT1 UNPACKING
Ø4
Position the drilling jig on an appropriate box and make the three holes. Install your cap in a box for
switches and insert the PCB with the potentiometer coming out from the center hole. Secure with
the two included screws. Cover the potentiometer with the gray knob.
19
PRELIMINARY
KA24/KA84
Follow the wiring scheme below to connect the 4-pin connector plugs. Follow the scheme on the
top if you own only one KA-POT1 and the one on the bottom if you own two KA-POT1. Then insert
one plug in the PCB and the other into the GPIO port on the amplifier.
20
KA-POT1 WIRING
PRELIMINARY
KA24/KA84
15. SERVICE
To obtain service:
1) Contact the official K-array distributor in your country. Your local distributor will direct you to the
appropriate service center.
2) If you are calling for service, please have the serial number(s) of the unit(s) available for reference.
Ask for Customer Service, and be prepared to describe the problem clearly and completely.
3) If the problem cannot be resolved over the phone, you may be required to send the unit in
for service. In this instance, you will be provided with an RA (Return Authorization) number which
should be included on all shipping documents and correspondence regarding the repair. Shipping
charges are the responsibility of the purchaser.
Any attempt to modify or replace components of the device will invalidate your warranty. Service
must be performed by an authorized K-array service center.
Cleaning:
Use only a soft, dry cloth to clean the housing. Do not use any solvents, chemicals, or
cleaning solutions containing alcohol, ammonia, or abrasives. Do not use any sprays near
the product or allow liquids to spill into any openings.
21
PRELIMINARY
KA24/KA84
16. SPECIFICATIONS
Max Power @ 4Ω
Max Power @ 8Ω
Max Power bridged @ 8Ω
Minimum impedance
Slew rate 8 Ω
Distortion (THD + N)
Input impedance
Gain
Output
Bandwidth
Damping factor
Thermal
Short circuit / over-load
Clip limit, Analog signal limit
Analog Connectors
Digital Connectors
Connectors
Connectors
NL4 1 wiring
NL4 2 wiring
Connector
Nominal voltage
Operating Range
Efciency
1/8 rated power (pink noise)@ 8Ω
Thermal dissipation
1 male + 1 female XLR parallel / 1 USB B Jack serial converter
KA24KA84
Power Output
4 x 600 W
4 x 300 W
2 x 1200 W
< 0.09% 1W to full power @ 4Ω (typically <0.05%)
180 BTU/h621 BTU/h
(1)
4 x 2000 W
(1)
(1)
4 x 1000 W
2 x 4000 W
4 Ω (single channel mode)
8 Ω (bridge mode)
Audio specs
50V/μS (input lter bypassed)
10 kΩ balanced
26 dB32 dB
Unbalanced to ground
20Hz 20KHz (+-1dB)
> 10000 @ 100Hz
Protection
Yes
Yes
Yes
Audio Input
4 male + 4 female 3-pin balanced XLR
1 male + 1 female 3-pin XLR
Remote control Input
Audio powered Output
2 x 4-pin Speakon NL4
1+1- = A1 | 2+2- = A2
1+1- = B1 | 2+2- = B2
AC power
2 x PowerCon IN/OUT
100 / 240 V, 50/60Hz with PFC
AC 90V - 264V
>79%(typical)
220 W600 W
1/8 of max output power @ 4Ω
1/4 of max output power @ 4Ω
(1)
(1)
(1)
22
Dimensions
Weight
396 BTU/h 1154 BTU/h
Certication
IP
20
Physical
426 mm x 304 mm x 88.2 mm
(19.1“ x 12” x 3.5 “)
5.5 Kg (12.12 lb)6.1 Kg (13.45 lb)
Notes for data
1. EIAJ Test Standard, 1KHz, 1%THD
New materials and design are introduced into existing products without previous notice. Present systems may differ
in some respects from those presented in this catalogue.
PRELIMINARY
KA24/KA84
The content s of this manual are f urnished for informational purposes only. K-array s.u.r.l. assumes no responsibility for any errors or inaccuracies that may appear
in this manual. K-array s.u.r.l. reserves the right to make modifications without prior notice.
23
PRELIMINARY
K-array s.u.r.l.
Via Paolina Romagnoli - 50037
San Piero a Sieve (Firenze) - Italy
tel. +39 055 8487222 - fax. +39 0558487238
e-mail: info@k-array.com
www.k-array.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.