Karma 622 Service Manual

MODEL 622
LIQUID COFFEE DISPENSER
For use with shelf stable liquid coffee
GENERAL DESCRIPTION
This model 622 - two flavor dispenser is designed for use with liquid concen­trate of various ratios (80:1-5:1). The model 622 uses peristaltic pumps to deliver the coffee concentrate and vend valves that deliver the water. The dis­pense ratio is 1 to 1.5 ounces per second. The dispensers efficient hot water tank produces portion sizes up to 60 ounces from cold water lines. If high vol­umes are needed, a hot water line connection can be made, or the dispenser can be connected to 240v.
MODEL 622
SPECIFICATIONS
DIMENSIONS:
Overall 9⁄” W x 26”D x 28 ⁄”H
CONSTRUCTION:
All Stainless Steel Cabinetry
ELECTRICAL:
115 V 50/60 HZ 12amps or 208/240 V 50/60 HZ 12 amps @ 240V
PLUMBING:
1/4” Waterline Filters
WATER RESERVOIR:
1 3/4 Gallons
DISPENSE SPOUTS:
2 independent mechanism for product
1 spout for hot water (center)
OPERATION:
Timed for each flavor
DISPENSE RATE:
1.5 ounces per second
PRODUCT COMPARTMENT SIZE:
8”H x 8”W x 9”D
SHIPPING WEIGHT:
68 lbs.
P.O. Box 433 Watertown, WI 53094 USA 920-261-1424 800-558-9565 Fax 920-261-3302 800-257-6806 Internet Web Page http://www.karma-inc.com E-mail - karma@karma-inc.com
Producers of dependable dispensing equipment
for the food and beverage industries.
KARMA dispensers are covered by one or more U.S. patents and applications and corresponding foreign patents and applications.
CAUTION: THE HOT WATER IN WATER TANK CAN CAUSE SEVERE BURNS. WHEN SERVICING OR CLEANING DO NOT TIP OR MOVE MACHINE CAUSING WATER TO SPILL.
DO NOT ATTEMPT TO REPAIR, ADJUST OR REPLACE COMPONENTS WITHOUT UNPLUGGING ELECTRICAL CORD.
CAUTION: WATER PIPE CONNECTIONS AND FIXTURES DIRECTLY CONNECTED TO A PORTABLE WATER SUPPLY SHALL BE SIZED, INSTALLED AND MAINTAINED ACCORDING TO FEDERAL, STATE, AND LOCAL LAWS.
TABLE OF CONTENTS
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Timer Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Exploded Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-12
Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
1
16
INSTALLATION
1. Connect a 1/4” waterline from a filtered source that provides a minimum flow rate of 1 GPM.
2. The electrical connection on the 115 V model requires a minimum 15 amp outlet for the line cord to be plugged into.
3. To connect this machine to 240V, cut the current plug off and replace with 240V plug or hard wire. Hook black and red wires to “HOT”, white wire to neutral and green wire to ground.
- NOTES -
OPTIONAL
STEP SIDE
WARMER
FIG. 1
WATERLINE
CONNECTION
Loading...
+ 7 hidden pages