Kärcher HD 10-23-4 SX Plus operation manual

HD 10/23-4 S HD 10/23-4 SX
Deutsch 6 English 15 Français 24 Italiano 34 Nederlands 44 Español 54 Português 64 Dansk 74 Norsk 83 Svenska 92 Suomi 101 Ελληνικά 110 Türkçe 120 Русский 129 Magyar 140 Čeština 149 Slovenščina 158 Polski 167 Româneşte 177 Slovenčina 187 Hrvatski 196 Srpski 205 Български 214 Eesti 225 Latviešu 234 Lietuviškai 243 Українська 252
001
59668640 07/16
2
3
HD 10/23-4 S
4
HD 10/23-4 SX
5
Lesen Sie vor der ersten Benut-
zung Ihres Gerätes diese Origi­nalbetriebsanleitung, handeln Sie danach und bewahren Sie diese für späteren Ge­brauch oder für Nachbesitzer auf.

Inhaltsverzeichnis

Geräteelemente . . . . . . . . . . . DE 1
Sicherheitshinweise . . . . . . . . DE 1
Bestimmungsgemäße Verwen-
dung . . . . . . . . . . . . . . . . . . . . DE 2
Sicherheitseinrichtungen. . . . . DE 2
Umweltschutz . . . . . . . . . . . . . DE 3
Vor Inbetriebnahme. . . . . . . . . DE 3
Inbetriebnahme. . . . . . . . . . . . DE 4
Bedienung. . . . . . . . . . . . . . . . DE 4
Transport. . . . . . . . . . . . . . . . . DE 6
Lagerung. . . . . . . . . . . . . . . . . DE 6
Pflege und Wartung . . . . . . . . DE 6
Hilfe bei Störungen . . . . . . . . . DE 7
Zubehör und Ersatzteile . . . . . DE 8
Garantie . . . . . . . . . . . . . . . . . DE 8
EU-Konformitätserklärung. . . . DE 8
Technische Daten . . . . . . . . . . DE 9

Geräteelemente

siehe Umschlagseite
1 Handspritzpistole EASY!Lock 2 Abzugshebel 3 Sicherungshebel 4 Hochdruckschlauch EASY!Lock 5 Halter für Handspritzpistole 6 Reinigungsmittel-Dosierventil 7 Verschlussdeckel für Reinigungsmittel-
tank 8 Reinigungsmitteltank 9 Reinigungsmittel-Saugschlauch mit Filter 10 Befestigungsschraube Gerätehaube 11 Geräteschalter 12 Gerätehaube 13 Manometer 14 Hochdruckanschluss EASY!Lock 15 Düsenablage 16 Wasseranschluss 17 Feinfilter 18 Ölstandsanzeige 19 Ölbehälter 20 Schlauchablage 21 Entlüftung Reinigungsmitteltank
22 Zubehörfach 23 Kabelhalter
24 Schlauchtrommel 25 Kurbel 26 Griff 27 Überwurfmutter 28 Düse 29 Strahlrohr EASY!Lock 30 Druck-/Mengenregulierung
(nur 1.286-911.0)
31 Sicherungsraste

Farbkennzeichnung

– Bedienelemente für den Reinigungs-
prozess sind gelb.
– Bedienelemente für die Wartung und
den Service sind hellgrau.

Sicherheitshinweise

– Vor erster Inbetriebnahme Sicherheits-
hinweise Nr. 5.951-949.0 unbedingt lesen!
– Jeweilige nationale Vorschriften des
Gesetzgebers für Flüssigkeitsstrahler beachten.
– Jeweilige nationale Vorschriften des
Gesetzgebers zur Unfallverhütung be­achten. Flüssigkeitsstrahler müssen re­gelmäßig geprüft und das Ergebnis der Prüfung schriftlich festgehalten werden.
– Am Gerät/Zubehör dürfen keine Verän-
derungen vorgenommen werden.

Gefahrenstufen

GEFAHR
Hinweis auf eine unmittelbar drohende Ge­fahr, die zu schweren Körperverletzungen oder zum Tod führt.
WARNUNG
Hinweis auf eine möglicherweise gefährli­che Situation, die zu schweren Körperver­letzungen oder zum Tod führen kann.
VORSICHT
Hinweis auf eine möglicherweise gefährli­che Situation, die zu leichten Verletzungen führen kann.
ACHTUNG
Hinweis auf eine möglicherweise gefährli­che Situation, die zu Sachschäden führen kann.
6 DE
– 1

Symbole auf dem Gerät

Hochdruckstrahlen können bei
unsachgemäßem Gebrauch ge­fährlich sein. Der Strahl darf nicht auf Per­sonen, Tiere, aktive elektrische Ausrüstung oder auf das Gerät selbst gerichtet werden. Gemäß gültiger Vorschriften darf das Gerät nie ohne Systemtrenner am Trinkwassernetz betrieben werden. Es ist ein geeigneter Sys­temtrenner der Fa. KÄRCHER oder alter­nativ ein Systemtrenner gemäß EN 12729 Typ BA zu verwenden. Wasser, das durch einen Systemtrenner geflossen ist, wird als nicht trinkbar einge­stuft.
VORSICHT
Systemtrenner immer an der Wasserver­sorgung, niemals direkt am Gerät anschlie­ßen.
Bestimmungsgemäße
Verwendung
Diesen Hochdruckreiniger ausschließlich verwenden – zum Reinigen mit dem Niederdruck-
strahl und Reinigungsmittel (z.B. Reini­gen von Maschinen, Fahrzeugen, Bau­werken, Werkzeugen),
– zum Reinigen mit Hochdruckstrahl
ohne Reinigungsmittel (z.B. Reinigen von Fassaden, Terrassen, Gartengerä-
ten). Für hartnäckige Verschmutzungen emp­fehlen wir den Dreckfräser als Sonderzube­hör.
Anforderungen an die Wasserqualität:
ACHTUNG
Als Hochdruckmedium darf nur sauberes Wasser verwendet werden. Verschmutzun­gen führen zu vorzeitigem Verschleiß oder Ablagerungen im Gerät. Wird Recyclingwasser verwendet, dürfen folgende Grenzwerte nicht überschritten werden.
pH-Wert 6,5...9,5 elektrische Leitfähigkeit * Leitfähigkeit
Frischwasser
+1200 µS/cm absetzbare Stoffe ** < 0,5 mg/l abfiltrierbare Stoffe *** < 50 mg/l Kohlenwasserstoffe < 20 mg/l Chlorid < 300 mg/l Sulfat < 240 mg/l Kalzium < 200 mg/l Gesamthärte < 28 °dH
< 50 °TH
< 500 ppm
(mg CaCO Eisen < 0,5 mg/l Mangan < 0,05 mg/l Kupfer < 2 mg/l Aktivchlor < 0,3 mg/l frei von üblen Gerüchen * Maximum insgesamt 2000 µS/cm
** Probevolumen 1 l, Absetzzeit 30 min *** keine abrasiven Stoffe
/l)
3

Sicherheitseinrichtungen

Sicherheitseinrichtungen dienen dem Schutz des Benutzers und dürfen nicht au­ßer Betrieb gesetzt oder in ihrer Funktion umgangen werden.

Überströmventil mit Druckschalter

Beim Reduzieren der Wassermenge mit der Druck-/Mengenregulierung öffnet das Überströmventil und ein Teil des Wassers fließt zur Pumpensaugseite zurück. Wird der Abzugshebel an der Handspritz­pistole losgelassen, schaltet der Druck­schalter die Pumpe ab, der Hochdruck­strahl stoppt. Wird der Abzugshebel gezo­gen, schaltet die Pumpe wieder ein. Überströmventil und Druckschalter sind werkseitig eingestellt und plombiert. Ein­stellung nur durch den Kundendienst. Bei zu hoher Stromaufnahme schaltet der Motorschutzschalter das Gerät ab.
– 2
7DE

Umweltschutz

2.
1.
Die Verpackungsmaterialien sind recyclebar. Bitte werfen Sie die Verpackungen nicht in den Haus­müll, sondern führen Sie diese ei­ner Wiederverwertung zu.
Altgeräte enthalten wertvolle recy­clingfähige Materialien, die einer Verwertung zugeführt werden soll­ten. Batterien, Öl und ähnliche Stoffe dürfen nicht in die Umwelt gelangen. Bitte entsorgen Sie Alt­geräte deshalb über geeignete Sammelsysteme.
Elektrische und elektronische Geräte ent­halten oft Bestandteile, die bei falschem Umgang oder falscher Entsorgung eine po­tentielle Gefahr für die menschliche Ge­sundheit und die Umwelt darstellen kön­nen. Für den ordnungsgemäßen Betrieb des Gerätes sind diese Bestandteile jedoch notwendig. Mit diesem Symbol gekenn­zeichnete Geräte dürfen nicht mit dem Hausmüll entsorgt werden.
Hinweise zu Inhaltsstoffen (REACH)
Aktuelle Informationen zu Inhaltsstoffen fin­den Sie unter:
www.kaercher.de/REACH

Vor Inbetriebnahme

Auspacken

Packungsinhalt beim Auspacken prüfen.
– – Bei Transportschaden sofort Händler
informieren.

Ölstand kontrollieren

Ölstandsanzeige bei stehendem Gerät
ablesen. Der Ölstand muss oberhalb der beiden Zeiger liegen.

Entlüftung Ölbehälter aktivieren

Befestigungsschraube der Gerätehau-
be herausdrehen, Gerätehaube abneh­men.
Spitze des Ölbehälterdeckels ab-
schneiden.
Gerätehaube befestigen.
Handspritzpistole, Strahlrohr und
Düse montieren
Hinweis: Das EASY!Lock-System verbin-
det Komponenten durch ein Schnellgewin­de mit nur einer Umdrehung schnell und si­cher.
Hochdruckdüse auf Strahlrohr stecken.Überwurfmutter montieren und hand-
fest anziehen (EASY!Lock).
Strahlrohr mit Handspritzpistole verbin-
den und handfest anziehen (EA­SY!Lock).

Zubehör montieren

Bei Geräten ohne Schlauchtrommel:
Hochdruckschlauch mit Handspritzpis-
tole und Hochdruckanschluss des Ge­rätes verbinden und handfest anziehen (EASY!Lock).
Kabelhalter in die seitliche Bohrung am
Griff einrasten.
Bei Geräten mit Schlauchtrommel:
Kurbel in die Schlauchtrommelwelle
einstecken und einrasten.
Hochdruckschlauch vor dem Aufwi-
ckeln gestreckt auslegen.
Hochdruckschlauch durch Drehen der
Kurbel in gleichmäßigen Lagen auf die Schlauchtrommel aufwickeln. Drehrich­tung so wählen, dass der Hochdruck­schlauch nicht geknickt wird.
Hochdruckschlauch mit Handspritzpis-
tole verbinden und handfest anziehen (EASY!Lock).
8 DE
– 3

Inbetriebnahme

WARNUNG
Verletzungsgefahr! Gerät, Zubehör, Zulei­tungen und Anschlüsse müssen in ein­wandfreiem Zustand sein. Falls der Zu­stand nicht einwandfrei ist, darf das Gerät nicht benutzt werden.

Elektrischer Anschluss

GEFAHR
Verletzungsgefahr durch elektrischen Schlag.
Das Gerät muss zwingend mit einem Ste-
cker an das elektrische Netz angeschlos­sen werden. Eine nicht trennbare Verbin­dung mit dem Stromnetz ist verboten. Der Stecker dient zur Netztrennung.
Gerät nur an Wechselstrom anschließen.Mindestabsicherung der Steckdose
(siehe Technische Daten).
– Die maximal zulässige Netzimpedanz
am elektrischen Anschlusspunkt (siehe Technische Daten) darf nicht über­schritten werden. Bei Unklarheiten be­züglich der an Ihrem Anschlusspunkt vorliegenden Netzimpedanz setzen Sie sich bitte mit Ihrem Energieversor­gungsunternehmen in Verbindung.
– Verlängerungskabel mit ausreichen-
dem Querschnitt verwenden (siehe „Technische Daten“) und ganz von der Kabeltrommel abwickeln.
Anschlusswerte siehe Typenschild/Techni­sche Daten. Netzkabel abwickeln und auf dem Bo-
den ablegen.
Netzstecker in eine Steckdose stecken.

Wasseranschluss

Anschluss an die Wasserleitung
WARNUNG
Vorschriften des Wasserversorgungsunter­nehmens beachten. Gemäß gültiger Vorschriften darf das Gerät nie ohne Systemtrenner am Trinkwassernetz betrieben werden. Es ist ein geeigneter Sys­temtrenner der Fa. KÄRCHER oder alter-
nativ ein Systemtrenner gemäß EN 12729 Typ BA zu verwenden. Wasser, das durch einen Systemtrenner geflossen ist, wird als nicht trinkbar einge­stuft.
Anschlusswerte siehe Technische Daten. Zulaufschlauch (Mindestlänge 7,5 m,
Mindestdurchmesser 3/4“) am Wasser­anschluss des Gerätes und am Was­serzulauf (zum Beispiel Wasserhahn) anschließen.
Hinweis:
Der Zulaufschlauch ist nicht im Lieferum­fang enthalten. Wasserzulauf öffnen.
Wasser aus offenen Behältern ansaugen
Saugschlauch mit Filter (Bestell-Nr.
4.440-238.0) am Wasseranschluss an­schrauben.
Gerät entlüften:
Düse abschrauben. Gerät so lange laufen lassen bis das Wasser blasenfrei austritt.
Gerät ausschalten und Düse wieder
aufschrauben.

Bedienung

GEFAHR
Verletzungsgefahr! Gerät nie ohne mon­tiertes Strahlrohr verwenden. Strahlrohr vor jeder Benutzung auf festen Sitz überprü­fen. Verschraubung des Strahlrohrs muss handfest angezogen sein. Explosionsgefahr! Keine brennbaren Flüssigkeiten versprü­hen. Beim Einsatz des Gerätes in Gefahrberei­chen (z.B. Tankstellen) sind die entsprechen­den Sicherheitsvorschriften zu beachten. Verletzungsgefahr! Beim Arbeiten Handspritzpistole und Strahlrohr mit beiden Händen halten. Verletzungsgefahr! Der Abzugshebel und der Sicherungshebel dürfen bei Betrieb nicht festgeklemmt werden. Verletzungsgefahr! Bei defektem Siche­rungshebel Kundendienst aufsuchen.
– 4
9DE
Verletzungsgefahr durch Hochdruckwas­serstrahl. Vor allen Arbeiten am Gerät Si­cherungsraste an der Handspritzpistole nach vorne schieben.
VORSICHT
Motoren nur an Stellen mit entsprechendem Ölabscheider reinigen (Umweltschutz).
ACHTUNG
Verstopfungsgefahr. Düsen nur mit der Mündung nach oben in das Zubehörfach legen.

Handspritzpistole öffnen/schließen

Handspritzpistole öffnen: Sicherungs-
hebel und Abzugshebel betätigen. Handspritzpistole schließen: Sicherungs-
hebel und Abzugshebel loslassen.

Betrieb mit Hochdruck

Hinweis:
Das Gerät ist mit einem Druckschalter aus­gestattet. Der Motor läuft nur an, wenn die Handspritzpistole geöffnet ist. Hochdruckschlauch ganz von der
Schlauchtrommel abrollen.
Geräteschalter auf „I“ stellen.
Kontrollleuchte leuchtet grün.
Handspritzpistole entsichern, dazu Si-
cherungsraste nach hinten schieben.
Handspritzpistole öffnen.
Nur 1.286-911.0:
GEFAHR
Beim Einstellen der Druck-/Mengenregulie­rung darauf achten, dass sich die Ver­schraubung des Strahlrohrs nicht löst.
Arbeitsdruck und Wassermenge durch
Drehen (stufenlos) an der Druck- und Mengenregulierung einstellen(+/-)

Betrieb mit Reinigungsmittel

WARNUNG
Ungeeignete Reinigungsmittel können das Gerät und das zu reinigende Objekt be­schädigen. Nur Reinigungsmittel verwen­den, die von Kärcher freigegeben sind. Do­sierempfehlung und Hinweise, die den Rei­nigungsmitteln beigegeben sind, beachten. Zum Schonen der Umwelt sparsam mit Reinigungsmitteln umgehen
Sicherheitshinweise auf den Reinigungs­mitteln beachten.
Kärcher-Reinigungsmittel garantieren ein störungsfreies Arbeiten. Bitte lassen Sie sich beraten oder fordern Sie unseren Ka­talog oder unsere Reinigungsmittel-Infor­mationsblätter an. Reinigungsmitteltank füllen.
GEFAHR
Verletzungsgefahr! Gerät vor Düsenwech­sel ausschalten und Handspritzpistole be­tätigen, bis Gerät drucklos ist.
Handspritzpistole sichern, dazu Siche-
rungsraste nach vorne schieben.
Hockdruckdüse durch Niederdruckdü-
se (Größe 250, Zubehör) ersetzen.
Reinigungsmittel-Dosierventil auf ge-
wünschte Konzentration stellen. Reinigungsmittelkonzentration [%] (bei max. Fördermenge)
Stellung Dosier­ventil
Reinigungsmittel­konzentration [%] (bei max. Förder­menge)
Empfohlene Reinigungsmethode
Reinigungsmittel sparsam auf die tro-
ckene Oberfläche sprühen und einwir-
ken (nicht trocknen) lassen. Gelösten Schmutz mit dem Hochdruck-
strahl abspülen. Nach dem Betrieb Filter in klares Was-
ser tauchen. Dosierventil auf höchste
Reinigungsmittel-Konzentration dre-
hen. Gerät starten und eine Minute lang
klarspülen.
1357
0,5 2,5 5,0 7,0

Betrieb unterbrechen

Handspritzpistole schließen.
Das Gerät schaltet sich ab. Handspritzpistole sichern, dazu Siche-
rungsraste nach vorne schieben.
Nach der Unterbrechung:
Handspritzpistole entsichern, dazu Si-
cherungsraste nach hinten schieben. Handspritzpistole öffnen.
Das Gerät schaltet sich wieder ein.
10 DE
– 5

Gerät ausschalten

Wasserzulauf schließen.Handspritzpistole öffnen.Pumpe mit Geräteschalter einschalten
und 5-10 Sekunden laufen lassen.
Handspritzpistole schließen.Geräteschalter auf „0/OFF“ stellen.Netzstecker nur mit trockenen Händen
aus Steckdose ziehen.
Wasseranschluss entfernen.Handspritzpistole betätigen, bis Gerät
drucklos ist.
Handspritzpistole sichern, dazu Siche-
rungsraste nach vorne schieben.
GEFAHR
Verbrühungsgefahr durch heißes Wasser. Im ausgeschalteten Gerät enthaltenes Restwas­ser kann sich erhitzen. Beim Entfernen des Schlauchs vom Wasserzulauf kann das er­hitzte Wasser herausspritzen und Verbrü­hungen verursachen. Schlauch erst abneh­men, wenn das Gerät abgekühlt ist.

Gerät aufbewahren

Handspritzpistole in den Halter stecken.Hochdruckschlauch aufwickeln und
über die Schlauchablage hängen. oder Hochdruckschlauch auf die Schlauch­trommel aufwickeln. Griff der Kurbel einschieben, um die Schlauchtrommel zu blockieren.
Anschlusskabel um den Kabelhalter wi-
ckeln.

Frostschutz

ACHTUNG
Frost zerstört das nicht vollständig von Wasser entleerte Gerät.
Gerät an einem frostfreien Ort aufbewahren.
Ist eine frostfreie Lagerung nicht möglich:
Reinigungsmitteltank leeren (siehe
„Pflege und Wartung/Bei Bedarf“).
Wasser ablassen.Handelsübliches Frostschutzmittel
durch das Gerät pumpen.
Hinweis:
Handelsübliches Frostschutzmittel für Au­tomobile auf Glykolbasis verwenden. Handhabungsvorschriften des Frostschutz­mittelherstellers beachten. Gerät max. 1 Minute laufen lassen bis
Pumpe und Leitungen leer sind.

Transport

VORSICHT
Verletzungs- und Beschädigungsgefahr! Gewicht des Gerätes beim Transport be­achten.
ACHTUNG
Abzugshebel während des Transports vor Beschädigung schützen.
Zum Transport über längere Strecken
Gerät am Griff hinter sich herziehen. Vor liegendem Transport Reinigungs-
mitteltank entleeren. Beim Transport in Fahrzeugen Gerät
nach den jeweils gültigen Richtlinien
gegen Rutschen und Kippen sichern.

Lagerung

VORSICHT
Verletzungs- und Beschädigungsgefahr! Gewicht des Gerätes bei Lagerung beach­ten.
Dieses Gerät darf nur in Innenräumen gela­gert werden.

Pflege und Wartung

GEFAHR
Verletzungsgefahr durch unabsichtlich an­laufendes Gerät und elektrischen Schlag. Vor allen Arbeiten am Gerät, Gerät aus­schalten und Netzstecker ziehen.
Hinweis:
Altöl darf nur von den dafür vorgesehenen Sammelstellen entsorgt werden. Bitte ge­ben Sie anfallendes Altöl dort ab. Ver­schmutzen der Umwelt mit Altöl ist strafbar.
Sicherheitsinspektion/
Wartungsvertrag
Mit Ihrem Händler können Sie eine regel­mäßige Sicherheitsinspektion vereinbaren oder einen Wartungsvertrag abschließen. Bitte lassen Sie sich beraten.
– 6
11DE

Vor jedem Betrieb

Anschlusskabel auf Schaden prüfen
(Gefahr durch elektrischen Schlag), be­schädigtes Anschlusskabel unverzüg­lich durch autorisierten Kundendienst/ Elektrofachkraft austauschen lassen.
Hochdruckschlauch auf Beschädigung
überprüfen (Berstgefahr). Beschädigten Hochdruckschlauch un­verzüglich austauschen.
Gerät (Pumpe) auf Dichtheit prüfen.
3 Tropfen Wasser pro Minute sind zu­lässig und können an der Geräteunter­seite austreten. Bei stärkerer Undichtigkeit Kundendienst aufsuchen.

Wöchentlich

Ölstand prüfen. Bei milchigem Öl (Wasser
im Öl) sofort Kundendienst aufsuchen.
Feinfilter reinigen.
Gerät drucklos machen. Befestigungsschraube der Gerätehaube herausdrehen, Gerätehaube abnehmen. Deckel mit Filter abschrauben. Filter mit sauberem Wasser oder Druckluft reinigen. In umgekehrter Reihenfolge zusam­menbauen.
Filter am Reinigungsmittel-Saug-
schlauch reinigen.
Alle 500 Betriebsstunden,
mindestens jährlich
Wartung des Gerätes vom Kunden-
dienst durchführen lassen.
Öl wechseln.
Ölwechsel Hinweis:
Ölmenge und -sorte siehe „Technische Daten“. Befestigungsschraube der Gerätehau-
be herausdrehen, Gerätehaube abneh­men.
Ölablassschraube vorne am Motorge-
häuse herausdrehen.
Öl in Auffangbehälter ablassen.Ölablassschraube eindrehen.Neues Öl langsam einfüllen; Luftblasen
müssen entweichen.
Deckel des Ölbehälters anbringen.Gerätehaube befestigen.

Bei Bedarf

Reinigungsmitteltank entleeren und rei-
nigen.
Verschlussdeckel für Reinigungsmittel-
tank mit Saugschlauch herausziehen.
Gerät auf die Rückseite legen.
Reinigungsmitteltank entleeren und rei-
nigen.

Hilfe bei Störungen

GEFAHR
Verletzungsgefahr durch unabsichtlich an­laufendes Gerät und elektrischen Schlag. – Vor allen Arbeiten am Gerät, Gerät aus-
schalten und Netzstecker ziehen. – Elektrische Bauteile nur vom autorisier-
ten Kundendienst prüfen und reparie-
ren lassen. – Bei Störungen, die in diesem Kapitel
nicht genannt sind, im Zweifelsfall und
bei ausdrücklichem Hinweis einen auto-
risierten Kundendienst aufsuchen.

Gerät läuft nicht

Anschlusskabel auf Schaden prüfen.Bei elektrischem Defekt Kundendienst
aufsuchen.

Gerät kommt nicht auf Druck

Hochdruckdüse montieren.Düse reinigen/erneuern.Feinfilter reinigen, bei Bedarf erneuern.Gerät entlüften (siehe „Inbetriebnahme“).Wasserzulaufmenge prüfen (siehe
Technische Daten). Sämtliche Zulaufleitungen zur Pumpe
prüfen. Bei Bedarf Kundendienst aufsuchen.

Pumpe undicht

3 Tropfen Wasser pro Minute sind zulässig und können an der Geräteunterseite aus­treten. Bei stärkerer Undichtigkeit Kunden­dienst aufsuchen. Bei stärkerer Undichtigkeit Gerät durch
Kundendienst prüfen lassen.
12 DE
– 7

Pumpe klopft

CEO
Head of Approbation
Saugleitungen für Wasser und Reini-
gungsmittel auf Undichtheit prüfen.
Gerät entlüften (siehe „Inbetriebnah-
me“).
Feinfilter reinigen.Bei Bedarf Kundendienst aufsuchen.
Reinigungsmittel wird nicht
angesaugt
Hochdruckdüse durch mitgelieferte
Niederdruckdüse ersetzen.
Reinigungsmittel-Saugschlauch mit Fil-
ter prüfen/reinigen.
Rückschlagventil im Anschluss des
Reinigungsmittel-Saugschlauches rei­nigen/erneuern.
Reinigungsmittel-Dosierventil öffnen
oder prüfen/reinigen.
Entlüftungsbohrung des Reinigungs-
mitteltanks im Gehäuse reinigen.
Bei Bedarf Kundendienst aufsuchen.

Zubehör und Ersatzteile

Nur Original-Zubehör und Original-Ersatz­teile verwenden, sie bieten die Gewähr für einen sicheren und störungsfreien Betrieb des Gerätes. Informationen über Zubehör und Ersatztei­le finden Sie unter www.kaercher.com.
schlägigen grundlegenden Sicherheits­und Gesundheitsanforderungen der EU­Richtlinien entspricht. Bei einer nicht mit uns abgestimmten Änderung der Maschine verliert diese Erklärung ihre Gültigkeit.
Produkt: Hochdruckreiniger Typ: 1.286-xxx Typ: 1.292-xxx Typ:
1.441-xxx
Einschlägige EU-Richtlinien
2006/42/EG (+2009/127/EG)
2014/30/EU
2000/14/EG
Angewandte harmonisierte Normen
EN 55014–1: 2006+A1: 2009+A2: 2011 EN 55014–2: 2015
EN 60335–1 EN 60335–2–79
EN 61000–3–2: 2006+A1: 2009+A2: 2009 EN 61000–3–3: 2013
EN 61000–3–11: 2000 EN 62233: 2008
Angewandtes Konformitätsbewertungs­verfahren
2000/14/EG: Anhang V
Schallleistungspegel dB(A)
Gemessen: 85 Garantiert: 87
Die Unterzeichnenden handeln im Auftrag und mit Vollmacht der Geschäftsführung.

Garantie

In jedem Land gelten die von unserer zu­ständigen Vertriebsgesellschaft herausge­gebenen Garantiebedingungen. Etwaige Störungen an Ihrem Gerät beseitigen wir innerhalb der Garantiefrist kostenlos, so­fern ein Material- oder Herstellungsfehler die Ursache sein sollte. Im Garantiefall wenden Sie sich bitte mit Kaufbeleg an Ih­ren Händler oder die nächste autorisierte Kundendienststelle.

EU-Konformitätserklärung

Hiermit erklären wir, dass die nachfolgend bezeichnete Maschine aufgrund ihrer Kon­zipierung und Bauart sowie in der von uns in Verkehr gebrachten Ausführung den ein-
Dokumentationsbevollmächtigter: S. Reiser
Alfred Kärcher GmbH & Co. KG Alfred-Kärcher-Str. 28 - 40 71364 Winnenden (Germany) Tel.: +49 7195 14-0 Fax: +49 7195 14-2212
Winnenden, 2016/03/01
– 8
13DE

Technische Daten

HD 10/23-4 S
1.286-922.0
HD 10/23-4 S
1.286-911.0
1.286-923.0
HD 10/23-4 SX
1.286-924.0
Netzanschluss
Spannung V 400 220 Stromart Hz 3~ 50 3~60 Anschlussleistung kW 9,0 Absicherung (träge, Char. C) A 13 25 Schutzart IPX5 Maximal zulässige Netzimpedanz Ohm (0,189+j0,118) (0,145+j0,090) Verlängerungskabel 10 m mm Verlängerungskabel 30 m mm
2 2
2,5
4
Wasseranschluss
Zulauftemperatur (max.) °C 60 Zulaufmenge (min.) l/h (l/min) 1200 (20) Saughöhe aus offenem Behälter (20 °C) m 0,5 Zulaufdruck (max.) MPa (bar) 1 (10)
Leistungsdaten
Arbeitsdruck Wasser (mit Standarddüse) MPa (bar) 23 (230) 3...23 (30...230) Düsengröße der Standarddüse 050 Max. Betriebsüberdruck MPa (bar) 25,3 (253) Fördermenge l/h (l/min) 1000 (16,7) Reinigungsmittelansaugung l/h (l/min) 0...80 (0...1,3) Rückstoßkraft der Handspritzpistole (max.) N 62
Ermittelte Werte gemäß EN 60335-2-79
Hand-Arm Vibrationswert Handspritzpistole m/s Strahlrohr m/s Unsicherheit K m/s Schalldruckpegel L Unsicherheit K Schallleistungspegel L
pA
pA
+ Unsicherheit K
WA
WA
2 2 2
<2,5 <2,5
dB(A) 72 dB(A) 2 dB(A) 87
1
Betriebsstoffe
Ölmenge l 1,2 Ölsorte SAE 90
Maße und Gewichte
Länge x Breite x Höhe mm 560 x 500 x 1090 Gewicht ohne Zubehör (SX) kg 66(68) Inhalt Reinigungsmitteltank l 6
14 DE
– 9
Please read and comply with
these original instructions prior to the initial operation of your appliance and store them for later use or subsequent own­ers.

Contents

Device elements . . . . . . . . . . . EN 1
Safety instructions. . . . . . . . . . EN 1
Proper use . . . . . . . . . . . . . . . EN 2
Safety Devices . . . . . . . . . . . . EN 2
Environmental protection . . . . EN 2
Before Startup . . . . . . . . . . . . . EN 3
Start up . . . . . . . . . . . . . . . . . . EN 3
Operation . . . . . . . . . . . . . . . . EN 4
Transport. . . . . . . . . . . . . . . . . EN 6
Storage . . . . . . . . . . . . . . . . . . EN 6
Care and maintenance . . . . . . EN 6
Troubleshooting . . . . . . . . . . . EN 7
Accessories and Spare Parts . EN 8
Warranty . . . . . . . . . . . . . . . . . EN 8
EU Declaration of Conformity . EN 8
Technical specifications . . . . . EN 9

Device elements

see cover page
1 Trigger gun EASY!Lock 2 Triggering lever 3 Safety lever 4 High pressure hose EASY!Lock 5 Trigger gun storage clip 6 Dosage valve for detergent 7 Locking cap for detergent tank 8 Detergent Tank 9 Detergent suction hose with filter 10 Fastening screw for device hood 11 Power switch 12 Cover 13 Manometer 14 High-pressure connection EASY!Lock 15 Storage compartment for nozzles 16 Water connection 17 Fine filter 18 Oil level indicator 19 Oil tank 20 Storage compartment for hoses 21 Deaerating the detergent tank 22 Accessory compartment 23 Cable clamp
24 Hose drum 25 Crank 26 Handle 27 Union joint 28 Nozzle 29 Spray lance EASY!Lock 30 Pressure/ quantity regulation
(1.286-911.0 only)
31 Safety catch

Colour coding

– The operating elements for the cleaning
process are yellow.
– The controls for the maintenance and
service are light gray.

Safety instructions

– Before first start-up it is definitely nec-
essary to read the operating instruc­tions and safety indications Nr. 5.951-
949.0!
– Please follow the national rules and
regulations for fluid spray jets of the re­spective country.
– Please follow the national rules and
regulations for accident prevention of the respective country. Fluid spray jets must be tested regularly and the results of these tests must be documented in writing.
– The appliance/accessories must not be
modified.

Hazard levels

DANGER
Pointer to immediate danger, which leads to severe injuries or death.
WARNING
Pointer to a possibly dangerous situation, which can lead to severe injuries or death.
CAUTION
Pointer to a possibly dangerous situation, which can lead to minor injuries.
ATTENTION
Pointer to a possibly dangerous situation, which can lead to property damage.
– 1
15EN

Symbols on the machine

High-pressure jets can be dan-
gerous if improperly used. The jet may not be directed at persons, animals, live electrical equipment or at the appliance itself. According to applicable regula­tions, the appliance must never be used on the drinking water net without a system separator. A suit­able system separator by KÄRCHER or al­ternatively a system separator according to EN 12729 type BA must be used. Water that was flowing through a system separator is considered non-drinkable.
CAUTION
Always connect the system separator to the water supply, never directly to the appli­ance!

Proper use

Use this high pressure cleaner exclusively for – Cleaning using low pressure jet and de-
tergent (for e.g. for cleaning machines, cars, buildings, tools),
– For cleaning using high pressure jet
without detergent (for e.g. for cleaning
facades, terraces, garden appliances). For stubborn dirt, we recommend the use of the dirt blaster as a special accessory.
Quality requirements for water:
ATTENTION
Only clean water may be used as high pressure medium. Impurities will lead to in­creased wear and tear or formation of de­posits in the appliance. If recycled water is used, the following limit values must not be exceeded.
pH value 6,5...9,5 electrical conductivity * Conductivity
fresh water
+1200 µS/cm settleable solids ** < 0,5 mg/l total suspended solids *** < 50 mg/l Hydrocarbons < 20 mg/l
Chloride < 300 mg/l Sulphate < 240 mg/l Calcium < 200 mg/l Total hardness < 28 °dH
< 50 °TH < 500 ppm
(mg CaCO Iron < 0,5 mg/l Manganese < 0,05 mg/l Copper < 2 mg/l Active chloride < 0,3 mg/l free of bad odours * Maximum total 2000 µS/cm
** Test volume 1 l, settling time 30 min *** no abrasive substances
/l)
3

Safety Devices

Safety devices serve to protect the user and must not be rendered in operational or their functions bypassed.

Overflow valve with pressure switch

While reducing the water supply/quantity regulation at the pump head, the overflow valve opens and part of the water flows back to the pump suck side. If the pulling lever on the trigger gun is re­leased the pressure switch turns off the pump, the high-pressure jet is stopped. If the pulling lever is pulled the pump is turned on again. The overflow valve and pressure switch are set and sealed at the factory. Setting only by customer service. The motor protection switch switches off the device if the power consumption is high.

Environmental protection

The packaging material can be recycled. Please do not throw the packaging material into household waste; please send it for recycling.
16 EN
– 2
Old appliances contain valuable
2.
1.
materials that can be recycled; these should be sent for recy­cling. Batteries, oil, and similar substances must not enter the environment. Please dispose of your old appliances using appro-
priate collection systems. Electrical and electronic devices often con­tain components which could potentially
pose a danger to human health and the en­vironment if handled or disposed of incor­rectly. However, these components are necessary for the proper operation of the device. Devices marked with this symbol must not be disposed of with regular house­hold rubbish.
Notes about the ingredients (REACH)
You will find current information about the ingredients at:
www.kaercher.com/REACH

Before Startup

Unpacking

– Check the contents of the pack before
unpacking.
– In case of transport damage inform ven-
dor immediately.

Check oil level

Read the oil level display when the de-
vice is not running. The oil level must be above the two pointers.

Activate deaeration of oil container

Unscrew the fastening screws of the
device hood; remove the device hood.
Cut off tip of oil container coverFasten the device hood.
Install hand spray gun, spray lance
and nozzle
Note: The EASY!Lock system joins com-
ponents with a quick-fasten thread solidly and securely with just one turn.
Insert the high pressure nozzle onto the
spray lance.
Install union nut and hand-tighten it
(EASY!Lock).
Join the spray lance with the trigger gun
and tighten until hand-tight (EASY!Lock).

Attaching the Accessories

In devices without hose drum:
Join the high-pressure hose with trigger
gun and high-pressure connection of the appliance and tighten until hand­tight (EASY!Lock).
Lock a cable clip in the side-hole on the
handle.
In devices with hose drum:
Insert the crank in the hose drum shaft
and lock it in.
Before rolling up, stretch out the high
pressure hose.
Wind the high pressure hose in uniform
layers on the hose drum by rotating the crank. Select the rotation direction in such a way that the high pressure hose does not get bent.
Join the high pressure hose with trigger
gun and tighten until hand-tight (EASY!Lock).

Start up

WARNING
Risk of injury! Appliance, accessories, sup­ply lines and connections must be in fault­free condition. If they are not in a perfect state then the appliance must not be used.
– 3
17EN

Electrical connection

DANGER
Danger of injury by electric shock. – It is imperative to connect the appliance
to the electric mains by means of a plug. It is forbidden to permanently connect the appliance to the power supply. The plug serves for the disconnection from the mains.
– The appliance may only be connected
to alternating current.
– Minimum fuse strength of the socket
(see Technical Data).
– The highest allowed net impedance at
the electrical connection point (refer to technical data) is not to be exceeded. In case of confusion regarding the power impedance present on your connection, please contact your utilities provider.
– Use the extension cord that has an ad-
equate cross-section (see "Technical Data") and unwind it fully from the cable drum.
For connection values, see type plate/tech­nical data. Unwind the mains cable and place it on
the floor.
Insert the mains plug into a socket.

Water connection

Connection to the water supply
WARNING
Observe regulations of water supplier. According to applicable regula­tions, the appliance must never be used on the drinking water net without a system separator. A suit­able system separator by KÄRCHER or al­ternatively a system separator according to EN 12729 type BA must be used. Water that was flowing through a system separator is considered non-drinkable.
For connection values refer to technical specifications. Connect the supply hose (minimum
length 7.5 m, minimum diameter 3/4“) to the water connection point of the ma-
chine and at the water supply point (for e.g. a tap).
Note:
The supply hose is not included. Open the water supply.
Drawing in water from open reservoirs
Screw the suction hose with filter (order
no. 4.440-238.0) to the water connec­tion.
Deaerate the appliance:
Unscrew the nozzle. Switch on the appliance and let it run until the water exiting is bubble-free.
Switch off the appliance and fit the noz-
zle again.

Operation

DANGER
Risk of injury! Never use the appliance without the spray lance attached. Check and ensure proper fitting of the spray lance prior to each use. The screw connection of the spray lance must be finger-tight. Risk of explosion! Do not spray flammable liquids. If the appliance is used in hazardous areas (e.g. filling stations) the corresponding safety regulations must be observed. Risk of injury! Hold the hand spray gun and the spray pipe firmly with both hands. Risk of injury! The trigger and safety lever may not be locked during the operation. Risk of injury! Contact Customer Service if the safety lever is damaged. Risk of injury from high-pressure water jet. Slide the safety catch on the trigger gun for­ward before performing any work with the appliance.
CAUTION
Clean engines only at places with corre­sponding oil separators (environmental safety).
ATTENTION
Risk of blocking. Place the nozzles in the accessory compartment with their joint pointing upward.
18 EN
– 4

Opening/closing the trigger gun

To open the trigger gun: Actuate the
safety lever and trigger.
To close the hand spray gun: Release
the safety lever and trigger.

High pressure operation

Note:
The appliance is equipped with a pressure switch. The motor starts up only when the trigger gun is open. Roll off the high pressure hose totally
from the hose drum.
Set the appliance switch to "I".
Control lamp glows green.
Release the trigger gun. To do so, push
the safety catch towards the back.
Open the hand spray gun.
Only 1.286-911.0:
DANGER
When adjusting the pressure/quantity regu­lation, make sure that the screw connection of the spray lance does not become loose.
Set working pressure and flow rate
through turning (runless) at the pres­sure- and amount regulation (B) (+/-).

Operation with detergent

WARNING
Unsuitable detergents can cause damage to the appliance and to the object to be cleaned. Use only those detergents that have been approved by Kärcher. Observe the dosage and other instructions provided with these detergents. For considerate treatment of the environment use detergent economically. Follow the safety instructions for using de­tergents.
Kärcher detergents ensure smooth func­tioning. Please consult us or ask for our cat­alogue or our detergent information sheets. Fill detergent tank.
DANGER
Risk of injury! Switch the appliance off prior to replacing nozzle and activate hand spray gun until device is pressureless.
Secure the trigger gun. To do so, push
the safety catch towards the front.
Replace high pressure nozzle with a
low pressure nozzle (size 250, attach­ment).
Set dosing value for detergent to the
desired concentration. Detergent concentration [%] (for max. flow quantity)
Position of the dos­ing valve
Detergent concen­tration [%] (for max. flow quantity)
Recommended cleaning method
Spray the detergent sparingly on the
dry surface and allow it to react, but not
to dry. Spray off loosened dirt with the high-
pressure ray. After operations, dip the filter in clear
water. Turn the dosing valve to the
highest detergent concentration. Start
the appliance and rinse for one minute.
1357
0,5 2,5 5,0 7,0

Interrupting operation

Close the hand spray gun.
The appliance switches off. Secure the trigger gun. To do so, push
the safety catch towards the front.
After the interruption:
Release the trigger gun. To do so, push
the safety catch towards the back. Open the hand spray gun.
The appliance will switch on again.

Turn off the appliance

Shut off water supply.
  Open the hand spray gun.Switch on the pump with the power
switch and allow to run for about 5-10
seconds.
Close the hand spray gun. Set the appliance switch to "0/OFF“.Pull main plug out of socket with dry
hands only. Remove water connection.
– 5
19EN
Activate hand spray gun until device is
pressure less.
Secure the trigger gun. To do so, push
the safety catch towards the front.
DANGER
Danger of scalding on account of hot water. The water remaining in the switched off de­vice can get heated up. When you remove the hose from the water inlet, the heated water can spray out and cause scalding. Do not remove the hose before the device has cooled down.

Storing the Appliance

Insert the hand-spray gun in the holder.Wind up the high-pressure hose and
hang it over the hose storage. or Wind up the high-pressure hose on the hose drum. Push in the handle of the crank to block the hose drum.
Wind the connection cable around the
cable holder.

Frost protection

ATTENTION
Frost will destroy the not completely water drained device.
Store the appliance in a frost free area.
If you cannot store it in a frost-free place:
Emptying the detergent tank (see "Care
and Maintenance/ as required").
Drain water. Pump in conventional frost protection
agents through the appliance.
Note:
Use normal glycol-based anti-freezing agents for automobiles. Observe handling instructions of the anti­freeze agent manufacturer. Operate device for max. 1 minute until
the pump and conduits are empty.

Transport

CAUTION
Risk of personal injury or damage! Mind the weight of the appliance during transport.
ATTENTION
Protect the trigger from damage during transport.
Pull the device behind you at the handle
for transporting it over longer distances. Empty the detergent tank before trans-
porting in horizontal position. When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.

Storage

CAUTION
Risk of personal injury or damage! Consid­er the weight of the appliance when storing it.
This appliance must only be stored in inte­rior rooms.

Care and maintenance

DANGER
Risk of injury by inadvertent startup of ap­pliance and electrical shock. Prior to all work on the appliance, switch off the appliance and pull the power plug.
Note:
Used oil must only be disposed of by the designated collection points. Please turn in used oil there. Polluting the environment with used oil is prosecutable.
Safety inspection/ maintenance
contract
You can sign with your dealer a contract for regular safety inspection or even sign a maintenance contract. Please take advice on this matter.

Before each use

Check connection cable for damages
(risk of electrical shock); get the dam-
aged connection cable replaced imme-
diately by an authorised customer ser-
vice person/ electrician. Check the high pressure hose for dam-
ages (risk of bursting).
Please arrange for the immediate ex-
change of a damaged high-pressure
hose.
20 EN
– 6
Check appliance (pump) for leaks.
3 drops per minute are permitted and can come out from the lower side of the appliance. Call Customer Service if there is heavy leakage.

Weekly

Check oil level Please contact Custom-
er Service immediately if the oil is milky (water in oil).
Clean the fine filter.
Unpressurize the appliance. Unscrew the fastening screws of the device hood; remove the device hood. Unscrew lid with filter. Clean the filter with clean water or com­pressed air. Reinstall in reverse sequence.
Clean filter at the detergent suck hose.
Every 500 operating hours, at least
annually
Have the maintenance of the device
performed by the customer service.
Oil change.
Oil change Note:
See "Specifications" for oil volume and type. Unscrew the fastening screws of the
device hood; remove the device hood.
Turn out the oil drain screw at the front
on the motor casing.
Drain the oil in a collection basin. Screw in the oil drain screw. Fill in new oil slowly; air bubbles should
go out.
Attach the lid of the oil container.Fasten the device hood.

If required

Empty and clean the detergent tank.
Pull out the locking cap for the deter­gent tank along with the suction hose. Lay the device on the reverse. Empty and clean the detergent tank.

Troubleshooting

DANGER
Risk of injury by inadvertent startup of ap­pliance and electrical shock. – Prior to all work on the appliance,
switch off the appliance and pull the
power plug. – Get the electrical components checked
and repaired only by authorised cus-
tomer service persons. – Contact an authorised customer service
person in case of problems not men-
tioned in this chapter or if you are in
doubt or when you have been explicitly
asked to do so.

Appliance is not running

Check connection cable for damages.Call Customer Service in case of elec-
trical defects.
Pressure does not build up in the
appliance
Install the high pressure nozzle.Clean/ replace nozzle. Clean the fine filter; replace it, if neces-
sary.
Deaerate the appliance (see "Start-up")Check water supply level (refer to tech-
nical data).
Check all inlet pipes to the pump. Contact Customer Service if needed.

Pump leaky

3 drops per minute are permitted and can come out from the lower side of the appli­ance. Call Customer Service if there is heavy leakage. With stronger leak, have device
checked by customer service.

Pump is vibrating

Check suction pipes for water and de-
tergent and ensure that they are leak-
proof.
Deaerate the appliance (see "Start-up")Clean the fine filter. Contact Customer Service if needed.
– 7
21EN

Detergent is not getting sucked in

CEO
Head of Approbation
Replace the high-pressure nozzle with
the included low-pressure nozzle.
Check/ clean detergent suction hose
with filter.
Clean/ replace backflow valve in the
connection of the detergent suction hose.
Open or check/clean detergent dosing
valve.
Clean the deaerating hole of the deter-
gent tank in the casing.
Contact Customer Service if needed.

Accessories and Spare Parts

Only use original accessories and spare parts, they ensure the safe and trouble-free operation of the device. For information about accessories and spare parts, please visit www.kaerch­er.com.

Warranty

The warranty terms published by the rele­vant sales company are applicable in each country. We will repair potential failures of your appliance within the warranty period free of charge, provided that such failure is caused by faulty material or defects in man­ufacturing. In the event of a warranty claim please contact your dealer or the nearest authorized Customer Service centre. Please submit the proof of purchase.

EU Declaration of Conformity

We hereby declare that the machine de­scribed below complies with the relevant basic safety and health requirements of the EU Directives, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the machine is modified without our prior approval.
Product: High pressure cleaner Type: 1.286-xxx Type: 1.292-xxx Type: 1.441-xxx Relevant EU Directives
2006/42/EC (+2009/127/EC) 2014/30/EU 2000/14/EC
Applied harmonized standards
EN 55014–1: 2006+A1: 2009+A2: 2011 EN 55014–2: 2015 EN 60335–1 EN 60335–2–79 EN 61000–3–2: 2006+A1: 2009+A2: 2009 EN 61000–3–3: 2013 EN 61000–3–11: 2000 EN 62233: 2008
Applied conformity evaluation method
2000/14/EC: Appendix V
Sound power level dB(A)
Measured: 85 Guaranteed: 87
The undersigned act on behalf and under the power of attorney of the company man­agement.
Authorised Documentation Representative S. Reiser
Alfred Kärcher GmbH Co. KG Alfred-Kärcher-Str. 28 - 40 71364 Winnenden (Germany) Phone: +49 7195 14-0 Fax: +49 7195 14-2212
Winnenden, 2016/03/01
22 EN
– 8

Technical specifications

HD 10/23-4 S
1.286-922.0
HD 10/23-4 S
1.286-911.0
1.286-923.0
HD 10/23-4 SX
1.286-924.0
Main Supply
Voltage V 400 220 Current type Hz 3~ 50 3~60 Connected load kW 9,0 Protection (slow, char. C) A 13 25 Type of protection IPX5 Maximum allowed net impedance Ohm (0,189+j0,118) (0,145+j0,090) Extension cable 10 m mm Extension cord 30 m mm
2
2
2,5
4
Water connection
Max. feed temperature °C 60 Min. feed volume l/h (l/min) 1200 (20) Suck height from open container (20 °C) m 0,5 Max. feed pressure MPa (bar) 1 (10)
Performance data
Operating pressure of water (using standard nozzle)
MPa (bar) 23 (230) 3...23
(30...230) Size of standard nozzle 050 Max. operating over-pressure MPa (bar) 25,3 (253) Flow rate l/h (l/min) 1000 (16,7) Detergent suck in l/h (l/min) 0...80 (0...1,3) Max. recoil force of trigger gun N 62
Values determined as per EN 60335-2-79
Hand-arm vibration value Hand spray gun m/s Spray lance m/s Uncertainty K m/s Sound pressure level L Uncertainty K
pA
Sound power level L
pA
+ Uncertainty K
WA
WA
2
2
2
<2,5 <2,5
dB(A) 72 dB(A) 2 dB(A) 87
1
Fuel
Amount of oil l 1,2 Oil grade SAE 90
Dimensions and weights
Length x width x height mm 560 x 500 x 1090 Weight without accessories (SX) kg 66(68) Content detergent tank l 6
– 9
23EN
Lire ce manuel d'utilisation origi-
nal avant la première utilisation de votre appareil, le respecter et le conser­ver pour une utilisation ultérieure ou pour le futur propriétaire.

Table des matières

Éléments de l'appareil. . . . . . . FR 1
Consignes de sécurité . . . . . . FR 1
Utilisation conforme . . . . . . . . FR 2
Dispositifs de sécurité. . . . . . . FR 2
Protection de l’environnement FR 3
Avant la mise en service. . . . . FR 3
Mise en service. . . . . . . . . . . . FR 4
Utilisation . . . . . . . . . . . . . . . . FR 5
Transport. . . . . . . . . . . . . . . . . FR 7
Entreposage . . . . . . . . . . . . . . FR 7
Entretien et maintenance . . . . FR 7
Assistance en cas de panne . . FR 8 Accessoires et pièces de re-
change . . . . . . . . . . . . . . . . . . FR 9
Garantie . . . . . . . . . . . . . . . . . FR 9
Déclaration UE de conformité . FR 9 Caractéristiques techniques . . FR 10

Éléments de l'appareil

cf. page de couverture
1 Pistolet de pulvérisation à main EA-
SY!Lock 2 Levier de départ 3 Manette de sécurité 4 Flexible haute pression EASY!Lock 5 Support de poignée-pistolet 6 Vanne de dosage du détergent 7 Couvercle de fermeture du réservoir de
détergent 8 Réservoir de détergent 9 Flexible d'aspiration du détergent avec
filtre 10 Vis de fixation du capot 11 Interrupteur principal 12 Capot 13 Manomètre 14 Raccordement haute pression EA-
SY!Lock 15 Récepteur de buse 16 Arrivée d'eau 17 Filtre fin 18 Indicateur de niveau d'huile
19 Réservoir d'huile 20 Dépose du flexible 21 Ventilation du réservoir de détergent 22 Espace de rangement pour les acces-
soires 23 Attache-câble 24 Dévidoir 25 Manivelle 26 Poignée 27 Écrou chapeau 28 Buse 29 Tube d’acier EASY!Lock 30 Régulateur de pression et de quantité
(seulement 1.286-911.0) 31 Cran de sécurité

Repérage de couleur

– Les éléments de commande pour le
processus de nettoyage sont jaunes. – Les éléments de commande pour la
maintenance et l'entretien sont en gris
clair.

Consignes de sécurité

– Avant la première mise en service, vous
devez impérativement avoir lu les
consignes de sécurité N° 5.951-949.0 ! – Respecter les dispositions légales na-
tionales respectives pour les jets de li-
quide. – Respecter les dispositions légales na-
tionales respectives pour la prévention
des accidents. Les jets de liquides
doivent être contrôlés régulièrement et
le résultat du contrôle consigné par
écrit. – Il est interdit d'effectuer des modifica-
tion sur l'appareil/les accessoires.

Niveaux de danger

DANGER
Signale la présence d'un danger imminent entraînant de graves blessures corporelles et pouvant avoir une issue mortelle.
AVERTISSEMENT
Signale la présence d'une situation éven­tuellement dangereuse pouvant entraîner de graves blessures corporelles et même avoir une issue mortelle.
24 FR
– 1
PRÉCAUTION
Remarque relative à une situation poten­tiellement dangereuse pouvant entraîner des blessures légères.
ATTENTION
Remarque relative à une situation éven­tuellement dangereuse pouvant entraîner des dommages matériels.

Des symboles sur l'appareil

Une utilisation incorrecte des
jets haute pression peut présen­ter des dangers. Le jet ne doit pas être diri­gé sur des personnes, animaux, installa­tions électriques actives ni sur l'appareil lui­même. Selon les directives en vigueur, l'appareil ne doit jamais être ex­ploité sans séparateur de système sur le réseau d'eau potable. Utili­ser un séparateur de système approprié de la société KÄRCHER ou en alternative un séparateur système selon EN 12729 type BA. L'eau qui s'est écoulée à travers un sépara­teur système est classifiée comme non po­table.
PRÉCAUTION
Toujours connecter le séparateur de sys­tème à l'alimentation en eau, et jamais di­rectement à l'appareil.

Utilisation conforme

Utiliser exclusivement ce nettoyeur haute pression – pour nettoyer au jet basse pression et
avec du détergent (par exemple pour le nettoyage de machines, véhicules, bâti­ments, outils),
– pour nettoyer au jet haute pression
sans détergent (par ex. nettoyage de façades, de terrasses, d'appareils de
jardinage). Pour des salissures tenaces nos recom­mandons le fraiseur de saleté comme ac­cessoire en option.
Exigences à la qualité d'eau :
ATTENTION
Utiliser uniquement de l'eau propre comme fluide haute pression. Des saletés en­traînent une usure prématurée ou des dé­pôts dans l'appareil. Si de l'eau de recyclage est utilisée, les va­leurs limites suivantes ne doivent pas être dépassées.
Valeur de pH 6,5...9,5 conductivité électrique * Conductivité
de l'eau du ro­binet +1200 µS/cm
substances qui se dé­posent **
substances qui peuvent être filtrées ***
Hydrocarbures < 20 mg/l Chlorure < 300 mg/l Sulfate < 240 mg/l calcium < 200 mg/l Dureté globale < 28 °dH
Fer < 0,5 mg/l Manganèse < 0,05 mg/l Cuivre < 2 mg/l Chlore actif < 0,3 mg/l exempt de mauvaises odeurs * Total maximal 2000 µS/cm
** Volume d'essai 1 l, temps de dépose 30 min *** pas de substance abrasive
< 0,5 mg/l
< 50 mg/l
< 50 °TH < 500 ppm (mg CaCO
/l)
3

Dispositifs de sécurité

Les dispositifs de sécurité ont pour but de protéger l'utilisateur et ils ne doivent donc jamais être désactivés ni évités.

Clapet de décharge avec pressostat

En cas de réduction de la quantité d'eau avec le réglage de pression/quantité, la cla­pet de décharge s'ouvre et une partie de
– 2
25FR
l'eau est évacuée vers le côté aspiration de
2.
1.
la pompe. Si vous relâchez la gâchette du pistolet ma­nuel, la pompe est coupée par un pressos­tat, le jet haute pression est arrêté. Si vous tirez sur la gâchette, la pompe est remise en service. Le clapet de dérivation et l'interrupteur de pression sont réglé et plombé par l'usine. Seul le service après-vente est autorisé à effectuer le réglage. Si la consommation de courant est trop éle­vée, le disjoncteur de protection moteur met l’appareil hors marche.
Protection de
l’environnement
Les matériaux constitutifs de l’emballage sont recyclables. Ne pas jeter les emballages dans les ordures ménagères, mais les remettre à un système de recy­clage.
Les appareils usés contiennent des matériaux précieux recy­clables lesquels doivent être ap­portés à un système de recy­clage. Il est interdit de jeter les batteries, l'huile et les subs­tances similaires dans l'environ­nement. Pour cette raison, utili­ser des systèmes de collecte adéquats afin d'éliminer les ap­pareils hors d'usage.
Les appareils électriques et électroniques renferment souvent des composants qui peuvent représenter un danger potentiel pour l'intégrité physique et l'environnement s'ils sont mal utilisés ou éliminés. Ces com­posants sont pourtant nécessaires au bon fonctionnement de l'appareil. Les appareils qui présentent ce symbole ne doivent pas être jetés avec les déchets ménagers.
Instructions relatives aux ingrédients (REACH)
Les informations actuelles relatives aux in­grédients se trouvent sous :
www.kaercher.com/REACH

Avant la mise en service

Déballage

– Vérifier le contenu du paquet lors de
l'ouverture de l'emballage.
– Contactez immédiatement le revendeur
en cas d'avarie de transport.

Contrôle du niveau d'huile

Affichage du niveau d'huile avec l'appa-
reil à l'arrêt. Le niveau d'huile doit repo­ser au-dessus des deux indicateurs.

Activer la purge du carter d'huile

Dévisser la vis de fixation du capot et
retirer celui-ci.
Couper la pointe du couvercle du réser-
voir d'huile.
Fixer le capot.
Monter la poignée pistolet, la lance
et la buse
Remarque : Le système EASY!Lock relie
les composants au moyen d’un filetage ra­pide et fiable avec une seule rotation.
Brancher la buse haute pression au
tube d’acier.
Monter l'écrou-raccord et le serrer à la
main (EASY!Lock).
Relier le tube d’acier au pistolet à main
et serrer à la main (EASY!Lock).

Montage des accessoires

Pour les appareils sans dévidoir :
Relier le flexible haute pression au pis-
tolet à main et au flexible haute pres-
26 FR
– 3
sion de l’appareil et serrer à la main
(EASY!Lock). Enclencher le support de câble dans
l'alésage latéral sur la poignée.
Pour les appareils avec dévidoir :
Enficher en enclencher la manivelle
dans l'arbre de dévidoir. Avant d'enrouler le flexible haute pres-
sion, veiller à le placer de manière ten-
due. Enrouler uniformément le flexible haute
pression sur le dévidoir en tournant la
manivelle. Choisir le sens de rotation de
telle sorte que le flexible haute pression
ne soit pas plié. Relier le flexible haute pression au pis-
tolet à main et serrer à la main (EA-
SY!Lock).

Mise en service

AVERTISSEMENT
Risque de blessure ! L'appareil, les acces­soires, les conduites et les raccords doivent être dans un parfait état. Ne pas utiliser l'appareil si son état n'est pas irrépro­chable.

Branchement électrique

DANGER
Risque d'électrocution. – L'appareil doit impérativement être rac-
cordé au réseau électrique avec une
fiche. Une connexion au secteur ne
pouvant pas être coupée est interdite.
La fiche électrique sert à la séparation
du secteur. – Branchement de l’appareil uniquement
à du courant alternatif. – Protection minimale par fusible de la
prise de courant (voir les données tech-
niques) – L'impédance de réseau maximale ad-
missible au niveau du point de raccor-
dement ne doit en aucun cas être dé-
passée (voir Caractéristiques tech-
niques). En cas de doute concernant
l'impédance de réseau présente sur
votre point de raccordement, veuillez
vous adresser à l'entreprise respon­sable de votre alimentation énergé­tique.
– Utiliser un câble de prolongation avec
une section suffisante (voir "Caractéris­tiques techniques") et le dérouler com­plètement de l'enrouleur.
Données de raccordement, voir plaque si­gnalétique / caractéristiques techniques Dérouler le câble secteur et le poser sur
le sol.
Brancher la fiche secteur dans une
prise de courant.

Arrivée d'eau

Raccordement à la conduite d'eau
AVERTISSEMENT
Respecter les prescriptions de votre socié­té distributrice en eau. Selon les directives en vigueur, l'appareil ne doit jamais être ex­ploité sans séparateur de système sur le réseau d'eau potable. Utili­ser un séparateur de système approprié de la société KÄRCHER ou en alternative un séparateur système selon EN 12729 type BA. L'eau qui s'est écoulée à travers un sépara­teur système est classifiée comme non po­table.
Pour les valeurs de raccordement, se re­porter à la section Caractéristiques tech­niques. Raccorder la conduite d'alimentation
(longueur minimale 7,5 m, diamètre mi­nimum 3/4") au raccord pour l'arrivée d'eau de l'appareil et à l'alimentation en eau (ex. un robinet).
Remarque :
La conduite d'alimentation n'est pas com­prise dans la livraison. Ouvrir l'alimentation d'eau.
Aspiration d'eau depuis des réservoirs ouverts
Visser le flexible d’aspiration avec le
filtre (n° de commande 4.440-238.0) sur la prise d’eau. Purge d'air de l'appareil :
– 4
27FR
Dévisser l'injecteur.
Laisser l'appareil en route jusqu'à l'eau
sorte sans faire de bulles. Arrêter l'appareil et dévisser de nou-
veau l'injecteur.

Utilisation

DANGER
Risque de blessure ! Ne jamais utiliser l'ap­pareil si la lance n'est pas montée. Contrô­ler avant chaque utilisation la bonne fixa­tion de la lance. Le raccord vissé de la lance doit être serré à la main. Risque d'explosion ! Ne pas pulvériser de liquides inflammables. Si l’appareil est utilisé dans des zones de danger (par exemple des stations es­sence), il faut tenir compte des consignes de sécurité correspondantes. Risque de blessure ! Pendant le travail, re­tenir la poignée pistolet et la lance des deux mains. Risque de blessure ! Lors du fonctionne­ment, ne pas coincer le levier de départ et le levier de sécurité. Risque de blessure ! En cas de levier de sécurité défectueux, se rendre au service après-vente. Risque de blessure dû au jet d’eau sous haute pression. Pousser, avant tout travail sur l’appareil, le cran de sécurité du pistolet manuel vers l’avant.
PRÉCAUTION
Nettoyer les moteurs uniquement à des en­droits équipés des séparateurs d'huile né­cessaires (protection de l'environnement).
ATTENTION
Risque d'obturation. Poser les buses uni­quement avec l'embouchure vers le haut dans le compartiment des accessoires.
Ouvrir/fermer le pistolet de
pulvérisation à main
Ouvrir le pistolet de pulvérisation à
main : Actionner le levier de sécurité et
le levier de départ. Fermer le pistolet de pulvérisation à
main. Relâcher le levier de sécurité et le
levier de départ.

Fonctionnement à haute pression

Remarque :
L'appareil est équipé d'un pressostat. Le moteur ne tourne que lorsque le pistolet manuel est ouvert. Dérouler complètement le flexible haute
pression de l'enrouleur.
Régler l'interrupteur principal sur "I".
Le témoin de contrôle s'allume (vert).
Enlever la sécurité du pistolet de pulvé-
risation à main en poussant le loquet de sécurité vers l’arrière.
Ouvrir le pistolet manuel.
Uniquement 1.286-911.0:
DANGER
Lors du réglage de la régulation de quanti­té/de pression, veiller que le raccord vissé de la lance ne se desserre pas.
Régler (+/-) la pression de service et le
débit en tournant (en continu) le dispo­sitif régulateur de pression et de quanti­té.

Fonctionnement avec détergent

AVERTISSEMENT
Des détergents non appropriés peuvent endommager l'appareil et l'objet à nettoyer. N'utiliser que des détergents homologués par Kärcher. Respecter les consignes et re­commandations de dosage jointes aux dé­tergents. Protéger l'environnement en utili­sant les détergents avec parcimonie. Respecter les consignes de sécurité men­tionnées sur les détergents.
Des détergents de Kärcher garantissent un travail sans défauts. Veuillez-vous conseil­ler ou demander notre catalogue ou notre bulletins d'information sur des produits de nettoyage. Remplir le réservoir de détergent.
DANGER
Risque de blessure ! Mettre l'appareil hors service et actionner la poignée-pistolet jus­qu'à ce que l'appareil soit hors pression avant de procéder au remplacement de la buse.
28 FR
– 5
Sécuriser le pistolet de pulvérisation à
main en poussant le loquet de sécurité
vers l’avant. Remplacer la buse haute pression par
la buse basse pression (taille 250, ac-
cessoires). Régler le clapet de dosage du dé-
tergent sur la concentration souhaitée. Concentration du détergent [%] (avec le débit max.)
Réglage de la sou­pape de dosage
Concentration de détergent [%] (avec le débit max.)
Méthode de nettoyage conseillée
Pulvériser le détergent sur la surface
sèche et laisser agir sans toutefois le
laisser sécher complètement. Ôter les salissures décollées à l'aide du
jet haute pression. Après utilisation, plonger le filtre dans
de l'eau claire. Tourner la valve de do-
sage sur la concentration en détergent
la plus élevée. Démarrer l'appareil et
rincer à l'eau claire pendant une minute.
1357
0,5 2,5 5,0 7,0

Interrompre le fonctionnement

Fermer la poignée-pistolet.
L'appareil se coupe automatiquement. Sécuriser le pistolet de pulvérisation à
main en poussant le loquet de sécurité
vers l’avant.
Après une interruption :
Enlever la sécurité du pistolet de pulvé-
risation à main en poussant le loquet de
sécurité vers l’arrière. Ouvrir le pistolet manuel.
L'appareil démarre de nouveau.

Mise hors service de l'appareil

Couper l'alimentation en eau.Ouvrir le pistolet manuel.Activer la pompe à l’aide de l’interrup-
teur principal et laisser tourner 5 à 10
secondes.
Fermer la poignée-pistolet.Positionner l'interrupteur sur '0/OFF'.
En veillant à avoir les mains bien
sèches, débrancher la fiche secteur.
Déconnecter l'arrivée d'eau.Actionner la poignée-pistolet jusqu'à ce
que l'appareil soit hors pression.
Sécuriser le pistolet de pulvérisation à
main en poussant le loquet de sécurité vers l’avant.
DANGER
Risque de brûlure provoquée par l'eau chaude . lorsque l'appareil est hors service, l'eau résiduelle contenue peut se réchauf­fer. Lors de l'enlèvement du tuyau de l'arri­vée d'eau, l'eau réchauffée peut être proje­tée et provoquer des ébouillantements. Re­tirer tout d'abord le tuyau lorsque l'appareil a refroidi.

Ranger l’appareil

Enficher la poignée-pistolet dans le
support.
Enrouler le flexible haute pression et
l'accrocher sur la dépose du flexible. ou Enrouler le flexible haute pression sur le dévidoir. Enfoncer la poignée de la manivelle pour bloquer le dévidoir.
Enrouler le câble d'alimentation autour
de l'attache-câbles.

Protection antigel

ATTENTION
Le gel peut endommager l'appareil si l'eau n'a pas été intégralement vidée.
Conserver l'appareil dans un lieu à l'abri du gel.
Si un entreposage à l'abri du gel n'est pas possible :
Vidanger le réservoir de détergent (voir
"Maintenance et entretien/si néces­saire").
Purger l'eau.
Pomper produit antigel d'usage par l'ap-
pareil.
Remarque :
utiliser un produit antigel courant pour auto­mobile à base de glycol.
– 6
29FR
Respecter les consignes d'utilisation du fa­bricant du produit antigel. Faire tourner l'appareil au max. 1 mi-
nute jusqu'à ce que la pompe et les
conduites soient entièrement vides.

Transport

PRÉCAUTION
Risque de blessure et d'endommagement ! Respecter le poids de l'appareil lors du transport.
ATTENTION
Protéger le levier de départ contre tout en­dommagement lors de son transport.
Pour transporter l’appareil sur de plus
longues distances, le tirer derrière soi
au moyen du manche de poussée. Vidanger le réservoir de détergent
avant un transport en position allongée. Sécuriser l'appareil contre les glisse-
ments ou les basculements selon les di-
rectives en vigueur lors du transport
dans des véhicules.

Entreposage

PRÉCAUTION
Risque de blessure et d'endommagement ! Prendre en compte le poids de l'appareil à l'entreposage.
Cet appareil doit uniquement être entrepo­sé en intérieur.

Entretien et maintenance

DANGER
Risque de blessure et de choc électrique par un démarrage inopiné de l'appareil. Avant d'effectuer des travaux sur l'appareil, couper l'interrupteur principal et débran­cher la fiche secteur.
Remarque :
L'huile usagée doit impérativement être éli­minée auprès d'un point de collecte prévu à cet effet. Y apporter l'huile usagée. L'huile usagée est polluante. Toute élimination in­correcte est passible d'une amende.
Inspection de sécurité/Contrat
d'entretien
Vous pouvez accorder avec votre commer­çant une inspection de sécurité régulière ou passer un contrat d'entretien. Conseil­lez-vous.

Avant chaque mise en service

Contrôler que le câble d'alimentation
n'est pas endommagé (risque de choc électrique), faire remplacer immédiate­ment tout câble d'alimentation endom­magé par un service après-vente auto­risé/un électricien spécialisé.
Vérifier le tuyau à haute pression s'il est
endommagé (danger d'éclatement). Un flexible haute pression endommagé doit immédiatement être remplacé.
Vérifier l'étanchéité de l'appareil
(pompe). 3 gouttes d'eau par minute sont admis­sibles et peuvent s'écoulent au côté in­férieure de l'appareil. En cas de non étanchéité plus forte, adressez-vous au Centre de Service Après-vente.

Hebdomadairement

Vérifier le niveau d'huile Si l'huile est lai-
teux (eau dans l'huile), adressez-vous immédiatement au Centre de Service Après-vente.
Nettoyer le filtre fin.
Mettre l'appareil hors pression. Dévisser la vis de fixation du capot et retirer celui-ci. Dévisser le couvercle et le filtre. Nettoyer le filtre à l'eau propre ou à l'air comprimé. Remonter en suivant les étapes dans l'ordre inverse.
Nettoyer le filtre situé sur le tuyau d'as-
piration de détergent.
Toutes les 500 heures de service, au
moins une fois par an.
Faire effectuer la maintenance de l'ap-
pareil par le service après-vente.
Remplacer l'huile.
30 FR
– 7
Loading...