Operating Instructions FR 30 Me English
For your own safety!
Use
¾ Prior to utilization the appliance
and its working facilities must
be checked regarding their
proper condition and that they
operate safely. It must not be
used if its condition is not
faultless.
— No modifications permitted on
the machine.
Operation
— Never reach under the unit
while the high-pressure cleaner
is operating
— Take into account the
afterrunning of the rotation arm
of the stopped unit
— Never direct the jet at humans
or animals
Intended use
The FR 30 is suitable for cleaning
floors and walls in conjunction with
a high-pressure cleaner.
Maximum water pressure:
25 MPa (250 bar)
Maximum water temperature:
85 °C
Important
Prior to initial operation of the unit
we request you to carefully read
the information given in the
operating instructions.
Inform your dealer immediately
of shipping damage.
Please dispose of packaging
environmentally responsibly
The packaging materials are
recyclable. Please do not throw
the packaging in with household
rubbish but take it to a recycling
centre.
Please dispose of scrapped
units environmentallyresponsibly
Scrapped units consist of valuable
recyclable materials that should be
taken to a recycling centre.
Batteries, oil and similar products
must not be allowed to
contaminate the environment.
Therefore, please dispose of
scrapped units via appropriate
disposal systems.
Nozzle kits
Warning!
The required nozzle kits are
adapted to the relevant connecting
unit and must be ordered
separately if they are not already
installed or included with the unit .
High-pressure cleaner with flow
rate of 450-500 l/h
Nozzle kit 2.640-482
High-pressure cleaner with flow
rate of 500-650 l/h
Nozzle kit 2.640-401
High-pressure cleaner with flow
rate of 650-850 l/h
Nozzle kit 2.639-187
High-pressure cleaner with flow
rate of 850-1100 l/h
Nozzle kit 2.640-442
High-pressure cleaner with flow
rate of 1100-1300 l/h
Nozzle kit 2.639-188
9

Operating Instructions FR 30 Me English
Nozzle kit assembly
Fig. 1
Note:
Observe sequence!
¾ Insert O-ring in groove of
rotation arm
¾ Plug-on nozzle
¾ Screw nozzle not too tight with
union nut
Fig. 2
Warning!
The discharge jet must be aligned
parallel to the rotation arm
¾ Align spanner-grip surface of
the nozzle (width across
flats 10) parallel to rotation arm
¾ Tighten union nut (width across
flats 22) with a spanner
Cleaning floors
Fig. 3
¾ Connect steel pipe of high
pressure cleaner to the FR 30
and tighten it with a spanner
(width A/F 24)
Cleaning walls
Preparation for
siphoning-off water
Note:
A suction device or a drain hose
can be connected with the
provided suction drain fitting
Removing the wheel set
(as required)
Fig. 4
¾ Do not remove swivel casters
from bracket
¾ Unscrew bracket from unit
¾ Refasten screws to the unit
(stabilisation of the bristles)
Installing the suction
fitting
Fig. 5
¾ Pull off cover
Fig. 6
¾ Fasten the suction fitting with
the supplied screws and nuts
High-pressure cleaner
connection
Fig. 7
¾ Disconnect angle joint from unit
(width A/F 27)
¾ Screw on handgun directly
¾ Tighten union nut with a
spanner
Siphoning-off water
options
Hose connection
Fig. 8
¾ Fasten hose with hose clamp to
suction fitting
Fig. 9
¾ Hold the unit at the centre
support
¾ Ensure that the hose hangs
down vertically
Siphon connection
Fig. 10
¾ The cover must be removed in
order to prevent a vacuum
developing
Fig. 11
¾ Connect hose of the siphon to
the suction fitting
Note
See accessory page for coupling
sleeves
Fig. 12
¾ Hold the unit at the centre
support
¾ Ensure that the hose hangs
down vertically
Care
— protect from frost
— Lubricate swivel casters
regularly
— Ensure bristles are not
deformed during storage
10

Zubehör /Accessories/Accessoires FR 30 Me