Kane KANE452NO Quick Reference Manual

Page 1
www.kane.co.uk
Welcome
KANE452NO Flue Gas Analyser with
direct CO
2 measurement,
CO sensor ‘over-range’ protection & low range NO sensor
Quick reference guide
Page 2
Menu controls ­Scroll Up/Down
Enter
Particle filter
Water trap
Flue gas inlet (see section 2)
Analyser connections (see section 2)
Battery charging indicator
Rotary switch
Function buttons x4 (see below)
Hello KANE452NO getting started
1 Know your KANE452NO
2 Connections
3 Before use
4 Product registration
Please register your analyser at www.kane.co.uk & download the full instruction manual from the product selector
PLEASE READ ALL SAFETY WARNINGS IN THE MANUAL
Analyser On/Off
Pump On/Off Hold button to zero pressure or zero gas
Torchlight On/Off
Send/Enter Send readings to printer Press for 1 second to print Press for 2 seconds to log
Know your KANE452NO
1
Page 3
Before use
3
Check
Particle lter is not dirty; Water trap & ue probe are empty of water; Water trap & red screw plug are tted to analyser; Flue probe hose is connected to ue gas inlet; Flue probe temperature plug is connected to T1 temperature connection
Fresh air purge
Position ue probe in fresh air & press “On/O” Analyser auto-calibrates within 90 seconds Select “Ratio” on dial. In fresh air CO reading = 0ppm Select “O
2/E” on dial. In fresh air 02 reading = 20.9%
Select “Status” on dial to view
For best pressure sensor accuracy
Switch analyser on for 5 minutes to let temperature stabilise Zero pressure sensor when analyser in exact position it will be used
To charge NiMH rechargeable batteries
Switch o Connect the charger; charging indicator illuminates Display shows “BATTERY CHARGING” if batteries need charging
Connections
2
Battery charger connection
Watertrap drain with red screw plug
Flue probe temperature T1
Inlet temperature T2
Pressure connection P1
Pressure connection P2 (Differential)
Flue gas inlet
Fit spigot to hose before connecting to flue gas inlet
Page 4
Northern Customer Service Kane International Ltd
Gibfield Park Avenue, Atherton, Manchester, M46 0SY, UK Tel: +44 (0) 1942 873434 Fax: +44 (0) 1942 873558 Email: nservice@kane.co.uk
Southern & International Customer Service Kane International Ltd
Kane House, 11 Bessemer Road, Welwyn Garden City, Hertfordshire, AL7 1GF, UK Tel: +44 (0) 1707 384834 Fax: +44 (0) 1707 384833 Email: sservice@kane.co.uk
01707 384810
UK Sales Line
Fax: 01707 393277
Email: sales@kane.co.uk
® The KANE logo is a registered trademark of Kane Group Limited. All other marks are trademarks of their respective holders.
Stock No. 20105 November 2017
Follow us on...
Outside UK Call
+44 1707 375550
4
We really want you to register your Kane analyser at www.kane.co.uk
Benefits include:
Download full instruction manual
Automatic reminder when time to
Service – Calibrate – Recertify
Fixed prices always visible
Simple online procedure to
arrange to Service - Calibrate
- Recertify ensures fastest turnaround times possible
Easy access to your calibration certicate & service history
Easy to report your analyser stolen
Product specic information &
resources in one place
Please register
Please register your analyser at www.kane.co.uk & download the full instruction manual from the product selector
PLEASE READ ALL SAFETY WARNINGS IN THE MANUAL
Loading...