Part IX: Warranty
Kaman Precision Products Standard Limited Warranty
Products of Kaman Precision Products are warranted to be free from
defects in materials and workmanship when installed and operated
in accord with instructions outlined in the instruction manual.
Kaman Precision Products' obligation under this warranty shall be
limited to repair or replacement (at the discretion of Kaman Precision Products of the defective goods returned to Kaman's plant
within one (1) year from date of shipment. Extreme environment
sensors are limited to the maximum operating temperature as
specified within the most current Kaman Precision Products
Extreme Environment Systems data sheets.
This warranty is valid except when the products have been subject
to misuse, accident, negligent damage in transit or handling, or
operation outside the conditions prescribed in the data sheet or
instruction manual. This will be determined by Kaman Precision Products
personnel.
In no event shall Kaman be liable for incidental or consequential
damages, including commercial loss, resulting from any article
sold under this Agreement.
In the event Buyer fails to limit to Kaman's warranty set forth
above, any express or implied warranty Buyer may make with
respect to any product of which any article sold thereunder is a
component, Buyer shall indemnify and hold Kaman harmless from
any and all liability, costs and expenses to which Kaman may be
subjected as a result of Buyer's failure to so limit its express or
implied warranties.
THIS WARRANTY IS EXCLUSIVE AND IS MADE IN LIEU
OF ALL OTHER WARRANTIES; AND THOSE IMPLIED
WARRANTIES, INCLUDING SPECIFICALLY THE
WARRANTIES OR MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE ARE HEREBY E X PRESSLY
LIMITED TO ONE (1) YEAR DURATION.
NO MODIFICATION OR ALTERATION OF THE
FOREGOING WARRANTY AND LIMITATION OR
REMEDIES PROVISIONS SHALL BE VALID OR
ENFORCEABLE UNLESS SET FORTH IN A WRITTEN
AGREEMENT SIGNED BY KAMAN AND THE BUYER.
Kaman Precision Products Warranty No. 7A
SMU-9000 User Manual 23 •••• Part IX: Warranty
Part I: Welcome
Introduction
Ka SMU-9000 measuring systems use
inductive (eddy current) technology to measure position without
contacting the target. SMU-9000 measuring systems are ideally
suited for applications requiring high resolution and economical
performance-to-price ratio. Based on Kaman’s proprietary Pulse Width Modulated electronics, the SMU-9000 systems incorporate
the latest surface-mount components with printed circuit board
designs. The use of pulse width modulation techniques virtuall y
eliminates the noise of traditional linear amplifiers, thereby
“unmasking” position/motion sensing down into sub-atomic
dimensions. This technology requires only simple, single ended
supply voltage and low power circuitry.
SMU-9000 User Manual 1 •••• Part I: Welcome
Features Summary / Advantages
• Extremely high resolution, to 1Å
• Signal-to-noise ratio: 1 PPM
• Precision of 0.1% of full scale, using computer correction.
• Small size for efficient system integration: 2 channels in less
than 5.5 cubic inches (91cc)
• Flexible packaging and performance.
• Multiple configurations available: 9000 single channel, 9200
dual or balanced differential operation, and three and four
channel models.
• Wide range of sensor options.
• Low power consumption: less than 40 mW per channel.
The SMU-9000
Figure 1. Single Channel SMU-9000.(Poly-carbonate Enclosure shown)
SMU-9000 User Manual 2 •••• Part I: Welcome
SMU-9000 Configurations
The SMU-9000 measuring system is available in several
configurations. These configurations include: Singl e Channel,
Dual Channel, Three Channel, and Four Channel systems shown
in figures 2 through 4. The system electronics is housed in an
enclosure made of die cast aluminum or poly-carbonate material.
Sensors for the SMU-9000 come in a wide variety. The selection
of a specific sensor is dependent upon the application in which the
system is used.
Figure 2. Outline Drawing, Single and Dual Channel SMU-9000
SMU-9000 User Manual 3 •••• Part I: Welcome
Figure 3. Outline Drawing, 3 Channel SMU-9000
Figure 4. Outline Drawing, 4 Channel SMU-9000
SMU-9000 User Manual 4 •••• Part I: Welcome
Part II: Setting Up the System
Power Supply Requirements
The critical circuit voltages needed for operation of the SMU9000 are internally regulated. Therefore, any single ended DC
voltage power supply which can furnish from 6.5 to 30 volts at
20ma per channel may be used.
Note: Avoid using switching power supplies if high resolution
(low noise) output is required.
The output amplifier runs directly from the supply voltage
(positive) and an internally generated negative voltage. The
system can be calibrated to have an output voltage swing
anywhere from -5 volts to within 1.5 volts below the supply
voltage. T ypi cal output voltage ranges and the r equired input
supply voltages are as follows:
Output Voltage Range Required Input Supply Voltage
-5 Vdc to +5 Vdc Requires a minimum 6.5 Volt
supply
0 Vdc to +10 Vdc Requires a minimum 11.5 Volt
supply
0.2 Vdc to 3.5 Vdc Requires a 5 Volt supply and
special 3.5 Volt internal requlator
to achieve minimum power drain
of 40 mW per channel
-10 Vdc to +10 Vdc
balanced differential
Table 1. Output Voltage Range and Required Input Voltages for
the SMU-9000
Requires differential SMU-9200
with ± 5 Volt output from each
channel and a minimum 6.5 Volt
supply
SMU-9000 User Manual 5 •••• Part II: Setting Up the System