Kaise SK-8402 Instruction Manual

SK
-8402
Instruction Manual
SK-8402 取扱説明書(英文)表1
O2 SENSOR CHECKER
CONTENTS
Thank you for purchasing KAISE "SK-8402 O2 SENSOR CHECKER". To obtain the maximum performance of this instrument, read this Instruction Manual carefully, and take safe measurement.
SAFETY PRECAUTIONS OPERATING PRECAUTIONS FEATURES UNPACKING AND INSPECTION NAME ILLUSTRATION SPECIFICATIONS
1. General Specifications
2. Measurement Specifications
3. LCD Specifications
4. Simulation Test
BEFORE USE
1. Types of O2 Sensors
2. Battery Installation
3. Confirmation of O2 Sensor Cables
4. Colors of O2 Sensor Cables
PREPARATION FOR USE
1. Inspection of Check Harness and Test Lead
2. Check Harness Connection
BASIC CONNECTION DIAGRAM NORMAL TEST
1. Measurement Flow Chart
2. Measurement Procedure with Check Harness
3. Measurement Procedure with Test Pin
SIMULATION TEST MAINTENANCE
1. Battery Replacement
2. Periodical Check and Calibration
TROUBLE SHOOTING WARRANTY
15 67
10
8 9
1112
1314
13
14
15 16 17 17
24
2531
3233 3438
39 39
41
23
SK-8402 取扱説明書(英文)表2
INTRODUCTION
40
2122
1820
SK-8402 取扱説明書(英文)_P1
SAFETY PRECAUTIONS (strict observance is required)
1
This instruction manual contains the important contents to prevent harm to user or others and damage of property, and to use the instrument safely and correctly. Read this manual carefully and obey the contents after having understand the following terms and symbols.
The points where the following symbols are attached in this manual describe the degree of harm and damage that would be caused by incorrect usage due to neglect of this description.
WARNING
CAUTION
This symbol in this manual advises the user of an electrical shock hazard that could result in serious injury or even death.
This symbol in this manual advises the user of an electrical shock hazard that could cause injury or material damages.
The points where the following symbols are attached in this manual describe the matters which must obey
in accordance with the each meanings. (following symbols are some examples.)
This symbol shows the warnings and cautions.
This symbol shows the prohibited matters.
This symbol shows the matters that is forced to do.
2
SK-8402 取扱説明書(英文)_P2
SAFETY PRECAUTIONS (strict observance is required)
WARNING
Be careful about your hands, gloves and clothes not to be caught in the engine belt or cooling fan.
Important to prevent injury.
Do not to touch the heated part of the engine such as exhausting parts.
Important to prevent burn injury.
Be careful not to catch your feet in the test leads.
Important to prevent injury.
Confirm that the shift lever is set to "Parking" position (set to "Neutral" for stick shift car).
The car runs accidentally and could cause unexpected accident, electric shock, or damage to the instrument or the car.
Confirm that the parking brake is applied.
The car runs accidentally and could cause unexpected accident, electric shock, or damage to the instrument or the car.
Take the measurement or its preparation under well-ventilated environment.
Carbon monoxide poisoning may occur due to the engine running during the measurement.
Use the "car lift" when lifting the car for measurement preparation.
Important to prevent any accident.
Use the supplied test leads and cables when taking the measurement.
Important to prevent any accident, electric shock, or damage to the instrument or the car.
SK-8402 取扱説明書(英文)_P3
3
SAFETY PRECAUTIONS (strict observance is required)
WARNING
Do not drive the car keeping the instrument connected.
Unexpected accident, electric shock, fire, or damage to the instrument or the car may occur.
Do not work under the car when it is jacked up.
Unexpected accident may occur.
Do not open the battery cover keeping the instrument connected to the car.
Electric shock may occur.
Do not replace the battery with the wet hands.
Electric shock may occur.
Keep the instrument away from babies or children.
Important to prevent any accident, injury, or electric shock hazard.
Do not work in the dark place.
Unexpected accident, electric shock, fire, or damage to the instrument or the car may occur.
Do not point the tip of Test Pin or Check Harness at the person.
Loss of eyesight or injury may occur.
Do not get the instrument wet.
Fire or electric shock may occur.
4
SK-8402 取扱説明書(英文)_P4
Do not attempt to disassemble or modify the instrument.
Fire, electric shock, or damage to the instrument may occur.
Do not use the instrument if it is in the abnormal condition.
Stop using the instrument immediately and consult with your local dealer when recognizing smoke, strange smell, or abnormal noise. Using the faulty instrument may cause the unexpected accident, fire, or electric shock.
Do not use the Test Lead or Check Harness with which coating were damaged by heat.
Fire or electric shock may occur.
SAFETY PRECAUTIONS (strict observance is required)
WARNING
Do not use the faulty instrument that can recognize such as display trouble, switch failure.
Stop using the instrument immediately and consult with your local dealer. Using the faulty instrument may cause the unexpected accident, fire, or electric shock.
SK-8402 取扱説明書(英文)_P5
5
SAFETY PRECAUTIONS (strict observance is required)
CAUTION
Be careful about the instrument or the cables not to be caught in the engine belt or cooling fan.
Short circuit or wire breaking may occur that could cause unexpected accident, electric shock, or damage to the instrument or the car.
Be careful about the instrument or the cables not to touch the heated part of the engine such as exhausting parts.
Important to prevent any accident, electric shock, or damage to the instrument or the car.
Do not use this instrument for a purpose other than O2 Sensor measurement.
Unexpected accident or damage to the instrument may occur.
Do not use any battery that have wrong rated specification.
Fire, injury, or damage to the surroundings may occur due to battery explosion or leakage.
Install the battery with the correct polarity as shown in the plus○+ and minus○− indications.
Installing with wrong polarity may cause fire, injury, or damage to the surroundings due to battery explosion or leakage.
Do not heat or disassemble the battery. Do not put the battery into the fire or water.
Fire or injury may occur due to battery explosion or leakage.
Dispose the exhausted battery in accordance with the local government rule after applying adhesive tape to both electrodes for insulation.
Disposing the battery with other conductive materials such as metal pieces may cause the fire or battery explosion due to their short circuit.
SK-8402 取扱説明書(英文)_P6
6
OPERATING PRECAUTIONS
SK-8402 is the O2 Sensor Checker for the O2 sensor of Zirconia, Titania 1V and Titania 5V. SK-8402 can not check deterioration judgment of A/F (air-fuel ratio) Sensor or Rear O2 Sensor.
Check object of this instrument is O2 sensor unit only. If the other parts are defective, engine trouble might not be solved even if the O2 sensor is replaced.
To obtain the stable measurement, keeping the engine speed at approx. 2,500rpm for 3 to 4 minutes to warm up the O2 sensor is necessary. When measuring the car without tachometer, estimate the engine speed by its sound. Keeping the constant engine speed at approx. 2,500rpm is also necessary during the normal test mode.
Scanning tool which can live monitor of ECU control is required to check ECU in simulation test.
Error code is memorized in Engine Control Unit (ECU) when taking off the connector of O2 sensor with the ignition key
switch is activated and the engine is running. Error code must be deleted by using the Code Reader or equivalent tool to prevent any engine troubles.
Do not apply any oil to Input Terminal, Test Lead, Check Harness, Alligator Clip or metal part of Test Pin to prevent contact failure.
Do not polish the case with the fluid that contains alcohol to prevent the cracking.
Use this instrument under the environment of 0 to 40, 80RH or less to obtain the accurate measurement.
Test Lead or Check Harness that coating are heat damaged might cause the short circuit. Do not use them and replace
into the new ones.
Measurement by using the Test Pin might weaken the waterproof property of the connectors of O2 sensor and ECU. Wrap heat-resistance/waterproof tape around them after taking the measurement.
Remove the batteries when the instrument is out of use for a long time. The exhaust battery might leak electrolyte and corrode the inside.
SK-8402 取扱説明書(英文)_P7
7
OPERATING PRECAUTIONS
Cautions for Handling
Do not apply mechanical shock.
 The shock such as dropping or beating might
damage the instrument and may cause the trouble.
Do not pull cables forcibly.
 Pulling the cables forcibly, such as when removing
the plugs from terminal, may cause the cable disconnection.
It might cause the instrument trouble if taking the simulation test with mischoice the type of O2 sensor (zirconia, titania 1V or titania 5V).
Do not take the simulation test for heater cable or power supply cable during the electric car components are activated. It may damage to the instrument.
Cautions for safekeeping
Do not keep the instrument in the following place.  ・The place where has the water splash  ・The place where applies the hard shock  ・-20 or less, 60℃ or more, 70%RH or more  ・The place where has the condensation  ・The place where is exposed to direct sunlight
SK-8402 取扱説明書(英文)_P8
8
FEATURES
Deterioration level of O2 sensor can be checked easily by bar-graph.
O2 sensor signal can be measured directly without changing the present exhaust system.
Simulated sensor signal output is possible that is useful for checking wiring error or ECU control with a combination of scanning tool.
Rich, Lean, Average voltages and Cycle are displayed respectively.
mV
RICH
TEST
Z
APO
GOOD CHECK BAD
mV
RICH
TEST
Z
APO
GOOD CHECK BAD
GOOD
(No problem)
mV
RICH
TEST
Z
APO
Rich voltage
mV
TEST
Z
AVG APO
Average voltage
mV
TEST
Z
LEAN
APO
Lean voltage
C
TEST
Z
APO
Cycle
CHECK
replacement
recommended
BAD
replacement
required
mV
RICH
TEST
Z
GOOD CHECK BAD
APO
(
)
(
P
O
W
E
R
(
1
S
e
c
<
)
S
(
1
S
ec
<
)
(
T
es
t
)
O
2
S
E
N
S
O
R
C
H
E
C
K
E
R
D
H
T5
T
1
Z
R
I
C
H
L
E
AN
DIS
P
L
AY
T
E
S
T
S
K
-
8
4
0
2
T
E
S
T
S
E
L
G
O
O
D
C
HEC
K
B
A
D
V
R
I
CH
T
E
S
T
Z
S
A
P
O
)
SK-8402 取扱説明書(英文)_P9
9
UNPACKING AND INSPECTION (Check before use)
Confirm if the following items are contained in the package in good condition. If there are any damages or missing items, ask your local dealer for replacement.
O2 Sensor Checker…1pce. ②Test Lead (100-65)…1pce. ③Check Harness (911)…1pce.
Alligator Clip (947)…1pce. ⑤Test Pins: Red & Black (795)
1pce. each
Carrying case (1030)…1pce.
Batteries (manganese 1.5V R6P, AA)
2pcs.
Instruction Manual…1pce.
Use parts numbers that are listed along with the
parts names when ordering them for replacement.
Use commercially available batteries for replacement.
POWER
(1Sec<)
S
(1Sec<)
(Test)
O2 SENSOR CHECKER
DH
T5
T1
Z
RICH
LEAN
DISPLAY
TEST
SK-8402
TEST SEL
C mV
AUTO
DH
RICH
TEST
ZT1T5
S
AVG
LEAN
APO
GOOD CHECK BAD
POWER
(1Sec<)
S
(1Sec<)
(Test)
O2 SENSOR CHECKER
DH
T5
T1
Z
RICH
LEAN
DISPLAY
TEST
SK-8402
TEST SEL
C mV
AUTO
DH
RICH
TEST
ZT1T5
S
AVG
LEAN
APO
GOOD CHECK BAD
SK-8402 取扱説明書(英文)_P10
10
NAME ILLUSTRATION
Input
Terminal
()
Input
Terminal
()
LCD
TEST Key
Press this key for 1 second or more to start the normal test.Press this key for 2 seconds or more to finish the normal test.Press this key less than 1 second to change the display mode
during the normal test. (this function is available when " " lights up)
Press this key to output simulated signal in the simulation test
mode.
DH
SEL Key (SELECT Key)
In stand-by modePress this key less than 1 second to select the
types of O2 sensor.
In stand-by modePress this key for 1 second or more to change
testing mode (normal test or simulation test).
In simulation testPress this key less than 1 second to change
RICH test or LEAN test.
Display HoldPress this key less than 1 second during normal test mode to
hold display value on LCD.(" " lights up)
To Cancel : Press SEL Key for 1 second or more.
DH
POWER Key
Press this key for 1 second or more
to turn on/turn off the unit.
O2 Sensor Checker
Power turns off automatically after approx. 20 minutes of the last key operation.
Note : Less than 2μA is consumed even in the power off condition. To cancel : Turn on the unit holding down SEL Key. ("APO" disappears
from LCD)
Auto Power Off (this function is activated in default setting)
⊿ΣConversion Input voltage calculation by microprocessor 500 times/second (LCD : 1 time/second in stand-by mode)
a. Numerical Display: LCD 999 count, 13 segment bar graph b. Units and Symbols: TEST, AUTO, , DH, Z, T1, T5, S, RICH, LEAN, AVG, APO, C, m, V,
within 1 second (in stand-by mode) Auto range (range-up) 0 to 40, 80RH or lower (in non-condensing)
-20 to 60, 70RH or lower (in non-condensing) Add ×0.01/ to the accuracy outside 23±5 "H" display on LCD when 6V or more is input (same display for overflow indication)
"- - -" display on LCD when + side of input terminal is grounded (only in stand-by mode) "- - -" display on LCD when input is less than threshold (same as grounding indication)
"Err" display on LCD when minus voltage is input between input terminals Err (error) : Indication of minus voltage input
"OL" blinks on LCD and stop testing when over current is detected during the simulation test OL (Over Load) : Warning indication of over current input
SK-8402 取扱説明書(英文)_P11
11
SPECIFICATIONS
1. General Specifications
OPERATING PRINCIPLE TEST METHOD SAMPLING RATE
DISPLAY (LCD)
RESPONSE TIME RANGE SELECTION
OPERATING TEMPERATURE & HUMIDITY
STORAGE TEMPERATURE & HUMIDITY
TEMPERATURE COEFFICIENT
OVERVOLTAGE INDICATION GROUNDING INDICATION OPEN-INPUT INDICATION
REVERSE CONNECTION WARNING
OVER CURRENT PROTECTION
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
SK-8402 取扱説明書(英文)_P12
12
SPECIFICATIONS
sign starts blinking when the battery voltage becomes at approx. 2.5V. Simulation test should be stopped when it is detected.
sign blinks on LCD at approx. 2.4V or less.
1.5V R6P or LR6(AA) batteries × 2 Hold LCD display by pressing SEL Key (effective in normal test mode) Power turns off automatically after approx. 20 minutes of the last key operation. (cancelable) Approx. 2.5V or more and 3.6V or less 10A or less in normal test mode (approx. 2μA or less in power-off mode) 300mVA MAX (in simulation test mode)
Approx.
80 hours (manganese battery)
Approx. 180 hours (alkaline battery)
1.1kV 50Hz sine wave, for 1 minute (between circuit and case) CE marking approved. (IEC61010-1 CAT 600V class2)
148(H)×83(W)×33(D)mm, approx. 220g
BATTERY WARNING
POWER SUPPLY DISPLAY HOLD AUTO POWER OFF OPERATING POWER SUPPLY VOLTAGE POWER CONSUMPTION
MAXIMUM MOMENTARY POWER CONSUMPTION
CONTINUOUS OPERATING TIME (in normal test mode)
DIELECTRIC STRENGTH SAFETY LEVEL
DIMENSION & WEIGHT (accessories are not included)
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
Product specifications and appearance are
subject to change without notice.