Kaise KT-2022 Instruction Manual

LISTED
82
CM
300
V CAT
600
V CAT
1
kV CAT
A
C
U L
US
KT-2022
Automotive DMM
LISTED
82
CM
300
V CAT
600
V CAT
1
kV CAT
10
A
C
U
L
US
KT-2022
Automotive DMM
- 1 -
- 2 - - 3 - - 4 -
To prevent an electrical shock hazard to the operator and/or damage to the instruments, read this instruction manual carefully before using the instrument. WARNINGS with the symbol on the instrument and this instruction manual are highly important.
Important Symbols
The symbol in this manual advises the user of an electrical shock hazard that could cause injury or material damages.
1. DISPLAYLCD
a. Numerical Display: 4 digit 6000 count, with Bar Graph   b. Units and Symbols
2. OPERATING PRINCIPLE Sigma-delta Conversion
3. MEASURING PRINCIPLE Average Rectification
4. SAMPLING RATE 5 times per second (Bar Graph40 times per second max.) 
5. RANGE SELECTIONAuto / Manual (Frequency, Injection Pulse width and
Capacitance measurement are Auto only)
6. BATTERY WARNING:indication at approx. 2.3V or less
7. DISPLAY HOLDHold indicating values by pressing HOLD Key
8. AUTO POWER OFFPower turns off automatically after approx. 34 minutes
9. OVERLOAD PROTECTION
10. OPERATING TEMPERATURE & HUMIDITY
Maximum relative humidity 80% for temperature up to 31 decreasing linearly to 50% relative humidity at 40
11. STORAGE TEMPERATURE & HUMIDITY
-20 to 60,less than80%RH in non-condensing.
12. TEMPERATURE COEFFICIENTAccuracy at 23±5×0.15/
13. SAFETY LEVELCE marking approved.
14. POWER SUPPLY1.5V R03(AAA) Battery ×2
15. FUSEFast-acting 11A/1000V(φ10×38mm)×1
Fast-acting 0.4A/1000V(φ6×32mm)×1
16. POWER CONSUMPTION:approx. 4.3mA (in Auto Power Off approx. 10
μ
A, in backlightingapprox. 27mA)
17. CONTINUOUS OPERATING TIME:approx. 180 hours (manganese cell),
approx. 360 hours (alkaline cell)
18. DIMENSIONS & WEIGHT161(H)×80(W)×50(D)mm, approx. 340g
19. ACCESSORIES
20. OPTIONAL ACCESSORIES
a)
μ
A & mA0.4A/1000V fast-acting fuse b) A11A/1000V fast-acting fuse c) V1050Vrms or 1450Vpeak d) mV, Ω and others1000Vrms
Thank you for purchasing "KT-2022 AUTOMOTIVE DIGITAL MULTIMETER". To obtain the maximum performance of this instrument, read this Instruction Manual carefully, and take safe measurement.
2. SPECIFICATIONS
Do not measure High Power Line (High Energy Circuits) that might exceed 6kVA. High Power Line is very dangerous and sometimes includes High Surge Voltage that could cause explosive short in the instrument and could result in serious injury to the operator. For dangerous voltage measurement, always keep the instrument away from your body without holding it in your hands. Do not touch the instrument, test leads, and any part of the circuit.
WARNING
FOR SAFETY MEASUREMENTS!!
The symbol listed in IEC 61010-1 and ISO 3864 means "Caution (refer to instruction manual)".
WARNING
CAUTION
The symbol in this manual advises the user of an electrical shock hazard that could result in serious injury or even death.
INTRODUCTION
Confirm if the following items are contained in the package in good condition. If there are any damage or missing items, ask your local dealer for replacement.
1. Digital Multimeter (with holster)
2. Test Lead (100-66)
3. RPM Sensor (653 / for Direct Ignition Engine)
4. RPM Sensor (654 / for High Tension Code)
5. Temperature Probe (818-02)
6. Alligator Clip (943)
7. Carrying Case (1024)
8. Spare Fuse (F38, 11A/1000V and F39, 0.4A/1000V)
9. Instruction Manual
1. UNPACKING AND INSPECTIONS
1 pce. 1 set 1 pce. 1 pce. 1 pce. 1 pce. 1 pce. 1 pce. each 1 pce.
AUTO, , , , , RPM , RPM , , , Ω, kΩ, MΩ, Hz, kHz, ms, V,
μ
F, μA, mA, A, %, Trig and decimal point
2-1. GENERAL SPECIFICATIONS
2-2. MEASUREMENT SPECIFICATIONS
(23±5, <80RH in non-condensing)
1. DC Voltage ( mV / V )
6.000 V
60.00 V
600.0 V 1000 V
±0.4rdg±3dgt
±0.7rdg±3dgt
Range
60.00 mV
600.0 mV
10MΩ,
50pF
1000Vrms
Accuracy
±0.4rdg±3dgt ±0.3rdg±3dgt
Resolution
0.01 mV
0.1 mV
Input
Impedance
Overload Protection
10MΩ,
50pF
1050Vrms
1450Vpeak
1 mV
10 mV
100 mV
1 V
2. AC Voltage ( 〜mV / V ) 50Hz to 500Hz
Average Rectification
3. DC Current ( μA / mA / A )
10A Continuous measurement is possible. 10A to 20A is measurable within 30 seconds but 5 minutes cooling down interval is necessary.
4. AC Current ( 〜μ
A / mA / A ) 50Hz to 500Hz
10A Continuous measurement is possible. 10A to 20A is measurable within 30 seconds but 5 minutes cooling down interval is necessary.
Average Rectification
5. Resistance ( Ω )
Range
600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000
M
Ω
60.00
M
Ω
0.45V DC
Accuracy
±0.5rdg±6dgt
±0.5rdg±3dgt
±0.8rdg±4dgt ±1.0rdg±5dgt ±1.5rdg±5dgt
Resolution
0.1 Ω 1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
Open Circuit Voltage
6. Frequency ( Hz )
Function
6 V
60 V
600 V
1000 V
±0.1rdg±3dgt
Range (Auto)
10 Hz to 10 kHz
10 Hz to 50 kHz
45 Hz to 1 kHz
Sensitivity
0.5 V rms 5 V rms 50 V rms
500 V rms
Accuracy
NOTE : Measurement cannot be made depending on the vehicles.
RPM4 RPM2
RPM2-M
Range 240 to 20000RPM 120 to 10000RPM
60 to 5000RPM
7. IP-RPM ( Inductive Pickup type )
±0.2rdg±20dgt
Accuracy
NOTE : Measurement cannot be made depending on the vehicles.
RPM4 RPM2
RPM2-M
Range 60 to 20000RPM 30 to 10000RPM
15 to 5000RPM
8. IG-RPM ( Contact Signal type )
±0.2rdg±20dgt
Accuracy
Selectable Number of Cylinders
1,2,3,4,5,6,8,10,12
(Select by CYLINDER Key)
WARNING 1. Checks of Body and Test Lead
WARNING 3. Warning for High Voltage Measurements
WARNING 4. Dangerous Voltage Measurement Procedure
WARNING 2. High Power Line Measurements is Prohibited
Before measurement, confirm the body of this instrument and handle insulators of the Test Lead have no cracks or any other damages. Dust, grease and moisture must be removed.
Do not hold multimeter in your hands. Keep safety distance from power source or circuit to be measured not to touch the dangerous voltage. Attach black and red alligator clips to test lead pins. Turn off the power of the circuit to be measured when connecting test leads. After measurement, before detaching alligator clips (test leads), turn the circuit power off and discharge the all capacitors.
For dangerous voltage measurement, strictly observe the warnings below.
3-1. WARNINGS
Correct knowledge of electric measurements is essential to avoid unexpected danger such as operator's injury or damage to the instrument. Read carefully and observe the following precautions for safety measurements.
3. SAFETY PRECAUTIONS
Even for Low Energy Circuits of electric/electronic appliances, such as heating elements, small motors, line cords and plugs, High Voltage Measurements are very dangerous. Do not touch any part of the circuit.
Do not measure High Power Line (High Energy Circuits) such as Distribution Transformers, Bus Bars and Large Motors. High Power Line sometimes includes High Surge Voltage that could cause explosive short in the instrument and could result in shock hazard. Generally, shock hazard could occur when the current between the circuit, that involves more than 33V rms or 46.7V DC or peak, and ground goes up to 0.5mA or more.
WARNING 1. Correct Selection of Function Switch
WARNING 2. Maximum Input Observance
WARNING 3. Test Lead Detachment
Do not measure anything that might exceed the specified maximum input values.
Always confirm that FUNCTION Switch is set to the correct position. Do not measure voltage except at Voltage measurement function.
Detach test leads from measuring circuit before changing measurement functions or removing rear cover for battery or fuse replacement.
In case of live-line measurement, strictly observe the warnings below
Do not hold multimeter in your hands. Keep safety distance from power source or circuit to be measured not to touch the dangerous voltage. Black test lead : Attach black alligator clip and connect to (earth) side of the circuit. Red test lead : Connect to (positive) side of the circuit.
3-3. GENERAL WARNINGS AND CAUTIONS
Children and the persons who do not have enough knowledge about electric measurements must not use this instrument. Do not measure the electricity naked or barefooted to protect yourself from electrical shock hazard. Be careful not to get hurt with the sharp test lead pins. Do not polish the case or attempt to clean it with any cleaning fluid like gasoline or benzine. If necessary, use silicon oil or antistatic fluid. Away the instrument from hot and humid conditions like in the car. Do not apply hard mechanical shock or vibration. Remove the battery when the instrument is out of use for a long time. The exhausted battery might leak electrolyte and corrode the inside.
WARNING 1.
WARNING 2.
WARNING 3. CAUTION 1.
CAUTION 2.
CAUTION 3. CAUTION 4.
Power turns off automatically after approx. 34 minutes of last operation.
To cancel it : Turn the power on holding down Select Key. Auto power off is disabled. NOTE : Small current consumption remains even in the auto power off condition.
Be sure to set FUNCTION Switch to "OFF" after finishing the measurement.
Caution (refer to instruction manual)
Alternating Current
Direct Current
Earth (Ground)
Fuse
Double Insulation
DC / AC
Do not apply around, or remove from HAZARDOUS LIVE conductors.
LCD displays "OL" when measurement value exceeds the maximum value of each measurement range.
The following symbol marks shown on the instrument and instruction manual are listed in IEC 61010-1 and ISO 3864.
0.4A/1000V and 11A/1000V fuses are installed to protect current measurement functions. If the fuse is blown out, replace it referring to "7-1. BATTERY AND FUSE REPLACEMENT".
4. NAME ILLUSTRATION
fig-1
LCD
FUNCTION Switch
Input Terminals
Hold Key ±TRIGGER
Key
(
Key
CYLINDER
Key
(
Select Key
Key
(
Range Key Level Key
(
fig-2
4-1. LCD
: Auto-ranging : Low battery warning : Dwell angle measurement : Continuity test : Lights up
in display hold function
: RPM measurement : Direct current (DC)
RPM
: Alternating current (AC) : Resistance measurement : Frequency measurement : Injection pulse width measurement : Voltage measurement : Capacitance measurement : Current measurement : Duty cycle
Ω, kΩ, MΩ
Hz, kHz
ms
mV, V
μ
F
μ
A, mA, A
4-11. Input Terminals
4-10. Level Key
Use this key to select the sensitivity level in IP-RPM, IG-RPM, Dwell Angle and Injection Pulse Width measurements.
Connect black test lead to COM terminal and red test lead to RPM/Temp+/Ω/V/ Terminal for all measurements except
μ
A, mA, A measurements.
NOTE:Connect red test lead to mA/
μ
A terminal for mA/μA measurement and connect it to
A terminal for 6A (10A for 30sec) measurement.
5. MEASUREMENT PROCEDURES
5-1. PREPARATION FOR USE
Read INSTRUCTION MANUAL carefully to understand the specification and functions correctly. "3. SAFETY PRECAUTIONS" is very important for safety measurement.
1. INSTRUCTION MANUAL
2. BATTERY
Two 1.5V R03 batteries are installed in this instrument. When " " lights up on LCD, replace them into the new ones referring to "7-1. BATTERY AND FUSE REPLACEMENT".
3. FUSE
4. OVERLOAD INDICATION
5. AUTO POWER OFF
6. SYMBOL MARK
Specified ranges depend on engine rpm and number of cylinders (cyl).
Range
0.0° to 360.0°
0.0 to 100.0
Accuracy
±1.2°/krpm±1dgt
±0.04/krpm/cyl±2dgt
9. Dwell Angle ( ), Duty Cycle ( )
Selectable Number of Cylinders
1,2,3,4,5,6,8,10,12
(Select by CYLINDER Key)
Specified ranges depend on trigger slopes, engine rpm and number of cylinders (cyl).
Accuracy
±0.05ms±1dgt
±0.04%/krpm±2dgt
±0.05ms±1dgt
±0.04%/krpm/cyl±2dgt
Range
0.05ms to 250.0ms
0.0% to 100.0%
0.05ms to 250.0ms
0.0% to 100.0%
10. Injection Pulse Width ( ms ), Duty Cycle ( )
Multi Point Injection
Single Point Injection
WARNING
Do not measure any voltage that might exceed maximum input value. (V1000V AC/DC, mV600mV AC/DC). Read "3. SAFETY PRECAUTIONS" carefully to avoid electric shock hazard and serious damage to the instrument. Do not touch any part of power line or the circuit to be measured.
1
2 3
4
5 6
Connect the instrument IN PARALLEL to the circuit. Use alligator clips for dangerous voltage measurement.
NOTE:Display shows " V→〜VHz " each time the Select Key is pressed. Connect black test lead to (earth) side of the circuit being measured and connect red test lead to (positive) side.
NOTE :
NOTE :
Read the measurement value on LCD. After finishing the measurement, set
FUNCTION Switch to "OFF".
5-2.
VOLTAGE AND FREQUENCY MEASUREMENT ( V / V / Hz ) ( mV / mV)
fig-3
Battery voltage measurement
Black()
Red()
Battery
( V / V / Hz )
Insert black test lead to COM terminal, and insert red test lead to RPM/Temp/Ω/V/ terminal. Set FUNCTION Switch to " ". Press Select Key to select DC( ) or AC( ).
V
Hz
100-66 Test Lead, 653 RPM Sensor (for Direct Ignition), 654 RPM Sensor (for High Tension Code), 818-02 Temperature Probe, 943 Alligator Clip, 1024 Carrying Case, Holster, 1.5V R03(AAA) Battery (Installed), F38 Spare Fuse (11A/1000V), F39 Spare Fuse (0.4A/1000V), Instruction Manual
11. Diode Test ( )
Range
1.000 V
Test Current
0.50mA typ.
Open Circuit Voltage
1.6V DC typ.
Accuracy
±1.0rdg±3dgt
Range
6.000
μ
F
60.00
μ
F
600.0
μ
F
2000
μ
F
Accuracy
±2.0rdg±5dgt
±3.5rdg±5dgt
±4.0rdg±5dgt
14. Capacitance ( )
660 AC/DC Clamp Adapter, 100-41 Test Lead Kit, 100-62 Test Lead Set, 944 Test Pin, 946 Battery Clip, 793 Coil Contact Pin
Threshold Level
between 10Ω and 200Ω
Response Time
32ms
13. Continuity ( )
Turns the power on and selects measurement functions. After measurement, turn it to "OFF".
4-3. Select Key
Use this Key to select sub-measurement functions.
4-2. FUNCTION Switch
Press this key for 1 second or more to turn on the LCD backlight. Press for 1 second or more again, backlight is turned off.
4-4.   Key
4-6. CYLINDER Key
4-8. ±TRIGGER Key
Change +/− Trigger slopes in Duty Cycle and Injection Pulse Width measurements. (Refer to 6-2).
4-5.    Key
4-7. Hold KeyDisplay Hold
Use this key to select the engine strokes in IP-RPM and IG-RPM measurements: Four-stroke/Two-stroke/Two-stroke, 2-cylinder simultaneous ignition.
Use this Key to set number of cylinders in Dwell Angle and IG-RPM measurements.
Holds displayed value on LCD by pressing this Key. ("  " lights up).
To release itPress Hold Key again.
FREQUENCY MEASUREMENT ( Hz )
(1)
(2) (3)
Press Select Key during voltage measurement. "Hz" lights up on LCD and Frequency of the measuring voltage is displayed. Press Select Key again to return to voltage measurement. In Frequency measurement, input sensitivity can be changed in the following procedures.
a.
b. c.
Press Level Key during frequency measurement. Input sensitivity level is changed as Level 1 (6V)2 (60V)3 (600V)4 (1000V). (default setting is Level 1 (6V)). Sensitivity level is shown with the number of " " under the bar graph. Change of input sensitivity is effective in the following cases. When measured value is unstable, reduce the current input sensitivity level. When measured value is "0", increase the current input sensitivity level.
( mV / mV )
1
2 3
4
5 6
Insert black test lead to COM terminal, and insert red test lead to RPM/Temp/Ω/V/ terminal. Set FUNCTION Switch to " ". Press Select Key to select DC ( ) or AC ( ) NOTE:Display shows " mV→〜mV→°C→°F " each time the Select Key is pressed. Connect black test lead to (earth) side of the circuit being measured and connect red test lead to (positive) side.
NOTE : Connect the instrument IN PARALLEL to the circuit. NOTE : Use alligator clips for dangerous voltage measurement.
Read the measurement value on LCD. After finishing the measurement, set FUNCTION Switch to "OFF".
Do not measure voltage in " " position. This will cause electrical shock hazard to the operator and/or damage to the instrument. Be careful not to drop off the instrument and test leads into the engine room. Ignition system generates high voltage that could cause an electrical shock hazard. Stop the engine when connecting or removing the test leads. Read "3. SAFETY PRECAUTIONS" carefully before measurement.
WARNING
5-3. RPM MEASUREMENT (IG-RPM) ※measuring RPM with test lead
-ms
IG-RPM
Stop the engine. Insert black test lead to COM terminal, and insert red test lead to RPM/Temp/Ω/V/ terminal. Set FUNCTION Switch to " ", and press Select Key until "RPM" appears on LCD.
-ms
IG-RPM
1 2
3
4-9. Range Key
Use this Key to change Auto or Manual-ranging (Refer to 6-1).
3-2. PREVENTION OF FAILURE
Maximum Input
600mV AC/DC
1000V AC/DC
6.000 V
60.00 V
600.0 V 1000 V
±2.0rdg±5dgt
±2.2rdg±5dgt
Range
60.00 mV
600.0 mV
10MΩ,
50pF
1000Vrms
Resolution
0.01 mV
0.1 mV
Input
Impedance
Overload Protection
10MΩ,
50pF
1050Vrms
1450Vpeak
Maximum Input
600mV AC/DC
1000V AC/DC
Accuracy
±2.0rdg±5dgt
1 mV
10 mV
100 mV
1 V
60.00 mA
600.0 mA
6.000 mA
10.00 mA
Range
600.0
μ
A
6000
μ
A
0.25mV
/μA
0.4A
1000V
Fuse
Resolution
0.1
μ
A
1
μ
A
Burden Voltage
Overload Protection
Maximum Input
6000
μ
A AC/DC
0.01 mA
0.1 mA 1 mA
10 mA
Accuracy
±0.7rdg±3dgt ±0.5rdg±3dgt
±0.7rdg±3dgt ±0.5rdg±3dgt ±0.7rdg±3dgt ±0.5rdg±3dgt
2.5mV
mA
0.4A
1000V
Fuse
600mA AC/DC
0.03V
A
11A
1000V
Fuse
10A AC/DC
60.00 mA
600.0 mA
6.000 mA
10.00 mA
Range
600.0
μ
A
6000
μ
A
0.25mV
/μA
0.4A
1000V
Fuse
Resolution
0.1
μ
A
1
μ
A
Burden Voltage
Overload Protection
Maximum Input
6000
μ
A AC/DC
0.01 mA
0.1 mA 1 mA
10 mA
Accuracy
±2.2rdg±5dgt ±2.0rdg±5dgt
±2.2rdg±5dgt ±2.0rdg±5dgt ±2.2rdg±5dgt ±1.2rdg±5dgt
2.5mV
mA
0.4A
1000V
Fuse
600mA AC/DC
0.03V
A
11A
1000V
Fuse
10A AC/DC
1000Vrms
Overload Protection
6553 count max.
Display
1000Vrms
Overload Protection
1000Vrms
Overload Protection
Resolution
0.001
μ
F
0.01
μ
F
0.1
μ
F
F
1000Vrms
Overload Protection
KT-2022
AUTOMOTIVE
DIGITAL MULTIMETER
INSTRUCTION MANUAL
LVDCAT1000V, CAT600V, CAT300V AC and DC EMCEN61326-1 (2013)
When using Clamp Adapter, read its instruction manual carefully.
K-type thermocouple / sensor accuracy is not included.
Range
-50°C to 1000°C
-58°F to 1832°F
Accuracy
±0.5rdg±3dgt ±0.5rdg±6dgt
12. Temperature ( °C /
°F
)
Resolution
1°C 1°F
1000Vrms
Overload Protection
LISTED
82
CM
300
V CAT
600
V CAT
1
kV CAT
A
C
U
L
US
KT-2022
Automotive DMM
LISTED
82
CM
300
V CAT
600
V CAT
1
kV CAT
A
C
U L
US
KT-2022
Automotive DMM
LISTED
82
CM
300
V CAT
600
V CAT
1
kV CAT
A
C
U L
US
KT-2022
Automotive DMM
- 5 -
- 6 - - 7 - - 8 -
Confirm if the clamp of the sensor is completely closed.
After finishing the measurement, remove the fixing tapes used for 653 RPM sensor.
Direct Ignition Engine:653 RPM Sensor Put contact surface of the sensor on the top or side of Direct Ignition Coil as shown in fig-7.
NOTE
NOTE NOTE
Measurement may not be done depending on the sensor position. In that case, move the sensor to the measurable position. Contact surface is marked in Red. Use tapes to fix the sensor.
fig-7
5-11. TEMPERATURE MEASUREMENT ( °C / °F )
Do not measure voltage in position. This will cause electrical shock hazard to the operator and/or damage to the instrument. Read "3. SAFETY PRECAUTIONS" carefully to avoid electric shock hazard and serious damage to the instrument.
WARNING
fig-8
4
5
6
7
8
9
Earth
IGNITION COIL
fig-4
+
_
Black()
Red()
Set number of cylinders. Press Cylinder Key for 1 second or more to enter cylinder setting mode, and press Cylinder Key again within 1 second to select the number of cylinders from 1, 2, 3, 4, 5, 6, 8, 10, 12. Default setting is "4". Stop pressing Cylinder Key when necessary number is displayed. Connect Test Lead to IGNITION COIL as shown in fig-4. Start the engine and read the measurement value on LCD. After finishing the measurement, set FUNCTION Switch to "OFF".
Input sensitivity can be changed in the following procedures.
a.
b. c.
Press Level Key during IG-RPM measurement. Input sensitivity level is changed as Level 3214. (default setting is Level 3). Sensitivity level is shown with the number of " " under the bar graph. Change of input sensitivity is effective in the following cases. When measured value is unstable, reduce the current input sensitivity level. When measured value is "0", increase the current input sensitivity level.
Do not measure voltage in " " position. This will cause electrical shock hazard to the operator and/or damage to the instrument. Read "3. SAFETY PRECAUTIONS" carefully before measurement.
WARNING
fig-6
ON
Throttle Body Injection (TBI)
ON
Port Fuel Injection (PFI)
INJECTOR
Red:Connect to ECU signal
Black:Connect to ground
12V
ECU signal
5-5. INJECTION PULSE WIDTH MEASUREMENT ( ms )
-ms
IG-RPM
1
2
3
4 5
Cautions for 654 RPM Sensor
Clamp a sensor gently without letting go of a lever suddenly when clamping 654 RPM Sensor on high tension cord. 654 RPM Sensor Pick Up may be damaged by strong shock. Do not apply hard mechanical shock to RPM Sensor by the fall.
CAUTION
1 2
3 4
5
6
7 8
Stop the engine. Insert black plug of 653 or 654 to COM terminal and inset red plug to RPM/Temp/Ω/V/ terminal. Set FUNCTION Switch to " ". Press Key and choose the engine strokes from the following list.
- Four-stroke cycle engine
- Two-stroke cycle engine
- Two-stroke cycle,
2-cylinder simultaneous ignition engine M
Clamp the sensor on No.1 High Tension Cord facing the arrow sign to the spark plug. (refer to fig-8)
NOTE
Start the engine and read the measurement value. After finishing the measurement, set
FUNCTION switch to "OFF". NOTE
High Tension Code type Engine : 654 RPM Sensor
KT-2022 is able to change the sensor sensitivity, however, RPM measurement may not be done depending on the types of engines. In that case, we recommend to use "SK-8401 Digital Tachometer". Do not apply hard mechanical shock to RPM Sensors. Measurement does not work for rotary engine / diesel engine / vehicles with MSD or MDI systems / some vehicles with wasted spark ignition.
NOTES FOR RPM MEASUREMENT
Input sensitivity can be changed in the following procedures.
a.
b. c.
Press Level Key during IP RPM measurement. Input sensitivity level is changed as Level 3214. (default setting is Level 3). Sensitivity level is shown with the number of " " under the bar graph. Change of input sensitivity is effective in the following cases. When measured value is unstable, reduce the current input sensitivity level. When measured value is "0", increase the current input sensitivity level.
Insert black test lead to COM terminal and insert red test lead to RPM/Temp/Ω/V/ terminal. Set FUNCTION Switch to " " and press Select Key until " MΩ " appears on LCD. If the resistor to be measured is connected in a circuit, turn off power to the circuit and discharge the all capacitors. Then, disconnect one side of the resistor. Connect test leads to the resistor (or circuit) to be measured. Read the measurement value on LCD. After finishing the measurement, set FUNCTION Switch to "OFF".
Do not measure voltage in position. This will cause electrical shock hazard to the operator and/or serious damage to the instrument. In case in-circuit resistance is measured, turn off power to the circuit being measured and discharge the all capacitors. Discharge high-capacity capacitor through appropriate resistance load. Read "3. SAFETY PRECAUTIONS" carefully before measurement.
1
2 3
4 5 6
WARNING
5-7. RESISTANCE MEASUREMENT ( Ω )
Insert black test lead to COM terminal and insert red test lead to RPM/Temp/Ω/V/ terminal. Set FUNCTION Switch to " " and press Select Key until " V " appears on LCD. If the diode is connected in a circuit, turn off the power to the circuit and discharge the all capacitors. Disconnect one side of the diode. Connect black test lead to Anode side and red test lead to Cathode side of the diode (Reverse connection). Confirm "OL" is displayed on LCD. Connect test leads to the opposite side of 4 (Forward Connection). Test results are good if the following voltage values are displayed on LCD.
After finishing the measurement, set FUNCTION Switch to "OFF".
1
2 3
4
5
6
Do not measure voltage in position. This will cause electrical shock hazard to the operator and/or damage to the instrument. If the diode is connected in a circuit, turn off the power to the circuit and discharge the all capacitors. Discharge high-capacity capacitor through appropriate resistance load. Read "3. SAFETY PRECAUTIONS" carefully before measurement.
fig-9
Black
Black
Red
Red
WARNING
Anode
Cathode
Anode
Cathode
Reverse Connection
Forward Connection
Silicon diodes....0.4V to 0.9V
Germanium diodes....0.1V to 0.4V
5-8. DIODE TEST ( )
+
_
5-4. DWELL ANGLE MEASUREMENT ( )
Do not measure voltage in " " position. This will cause electrical shock hazard to the operator and/or damage to the instrument. Be careful not to drop off the instrument and test leads into the engine room. Ignition system generates high voltage that could cause an electrical shock hazard. Stop the engine when connecting or removing the test leads. Read "3. SAFETY PRECAUTIONS" carefully before measurement.
WARNING
-ms
IG-RPM
1 2
3
4
5
6
7 8
Start the engine and read the measurement value on LCD. After finishing the measurement, set FUNCTION Switch to "OFF".
Earth
IGNITION COIL
fig-5
Black()
Red()
Stop the engine. Insert black test lead to COM terminal, and insert red test lead to RPM/Temp/Ω/V/ terminal. Set FUNCTION Switch to " ", and press Select Key until " " appears on LCD. Set number of cylinders. Press Cylinder Key for 1 second or more to enter cylinder setting mode, and press Cylinder Key again within 1 second to select the number of cylinders from 1, 2, 3, 4, 5, 6, 8, 10, 12. Default setting is "4". Stop pressing Cylinder Key when necessary number is displayed. Connect Test Lead to IGNITION COIL as shown in fig-5.
-ms
IG-RPM
Duty Cycle (%) Converted value is displayed by pressing Select Key once during Dwell Angle measurement. Input sensitivity can be changed in the following procedures.
DUTY CYCLE MEASUREMENT ( % )
a.
b. c.
Press Level Key during Duty Cycle measurement. Input sensitivity level is changed as Level 3214. (default setting is Level 3). Sensitivity level is shown with the number of " " under the bar graph. Change of input sensitivity is effective in the following cases. When measured value is unstable, reduce the current input sensitivity level. When measured value is "0", increase the current input sensitivity level.
Duty Cycle (%) Converted value is displayed by pressing Select Key three times during Injection Pulse Width measurement. Input sensitivity can be changed in the following procedures.
DUTY CYCLE MEASUREMENT ( % )
a.
b. c.
Press Level Key during Duty Cycle measurement. Input sensitivity level is changed as Level 3214. (default setting is Level 3). Sensitivity level is shown with the number of " " under the bar graph. Change of input sensitivity is effective in the following cases. When measured value is unstable, reduce the current input sensitivity level. When measured value is "0", increase the current input sensitivity level.
Do not measure voltage in position. This will cause electrical shock hazard to the operator and/or damage to the instrument. Be careful not to drop off the instrument and RPM sensor into the engine room. Ignition system generates high voltage that could cause an electrical shock hazard. Stop the engine when connecting or removing the RPM sensor. Read "3. SAFETY PRECAUTIONS" carefully before measurement.
WARNING
5-6. RPM MEASUREMENT ( IP-RPM ) ※measuring RPM with RPM Sensor
5-9. CONTINUITY TEST ( )
Do not measure voltage in position. This will cause electrical shock hazard to the operator and/or damage to the instrument. When measuring in-circuit continuity, turn off power to the circuit to be measured and discharge the all capacitors. Discharge high-capacity capacitor through appropriate resistance load. Read "3. SAFETY PRECAUTIONS" carefully before measurement.
WARNING
1
2 3
4
5
Insert black test lead to COM terminal and insert red test lead to RPM/Temp+/Ω/V/ terminal. Set FUNCTION Switch to " " and press Select Key until " " appears on LCD. If the diode is connected in a circuit, turn off the power to the circuit and discharge the all capacitors. Disconnect one side of the diode. Connect test lead to both side of the circuit to be measured. Buzzer sounds when the circuit resistance is between 10Ω and 200Ω. After finishing the measurement, set FUNCTION Switch to "OFF".
5-10. CAPACITANCE MEASUREMENT ( )
Do not measure voltage in position. This will cause electrical shock hazard to the operator and/or damage to the instrument. If the capacitor is connected in a circuit, turn off the power to the circuit and discharge the all capacitors. Discharge high-capacity capacitor through appropriate resistance load. Read "3. SAFETY PRECAUTIONS" carefully before measurement.
WARNING
1
2 3
4 5
6
Insert black test lead to COM terminal and insert red test lead to RPM/Temp/Ω/V/ terminal. Set FUNCTION Switch to " " and press Select Key until "
μ
F " appears on LCD. If the capacitor is connected in a circuit, turn off the power to the circuit and discharge the all capacitors. Disconnect one side of the capacitor. Connect test lead to both side of the capacitor to be measured. Read the measurement value on LCD. NOTE:High capacitance capacitor should be taken longer to get a measurement value. After finishing the measurement, set FUNCTION Switch to "OFF".
1
2
3 4
Insert "" side of temperature probe to COM terminal and insert "" side to RPM/Temp+ /Ω/V/  terminal. Set FUNCTION Switch to " " and press Select Key until
°C (
) or
°F ( )
appears on LCD. Put the tip of temperature probe on the object to be measured, and read the LCD. After finishing the measurement, set FUNCTION Switch to "OFF".
6-3. LCD BACKLIGHT
1
2
Backlight turns on LCD. It helps the measurement in a dark place.
6-4. IMPROPER CONNECTION WARNING
1
2
When the function except " " and "  " is selected, warning buzzer sounds with "InEr" indication on LCD by connecting test lead to "mA/
μ
A" or "A" terminal.
When the function "   " is selected, warning buzzer sounds with "InEr" indication on LCD by connecting test lead to "A" terminal.
Insert black test lead to COM terminal, and insert red test lead to RPM/Temp/Ω/V/ terminal. Set FUNCTION Switch to " ", and press Select Key until " ms " appears on LCD. Connect test leads to an INJECTOR as shown in fig-6.
NOTE
NOTE
Read the measurement value on LCD. After finishing the measurement, set FUNCTION Switch to "OFF". This function can measure both Port Fuel Injectors (PFI) which operate with a single on time pulse and Throttle Body Injectors (TBI) which operate with twin pulses.
Try some connections to find ECU signal when it is difficult to be found depending on the injection wiring. Use of 100-41 Test Lead Kit or 100-62 Test Lead Set, which contains a narrow test pin model 792, are recommended for safety measurement.
-ms
IG-RPM
Do not measure the current that exceeds the maximum value (A:10A AC/DC, mA 600mA AC/DC,
μ
A6000μA AC/DC) to avoid electrical shock hazard and/or damage
to the instrument. Connect RED test lead to "mA/
μ
A" or "A" terminal. Do not measure the current that exceeds 250V open circuit voltage. 20A AC/DC measurement is possible, but within 30 seconds. For continuous measurement, every 5 minutes interval is necessary for cooling down. Do not measure voltage in " " or " " position. This will cause electrical shock hazard to the operator and/or damage to the instrument. Read "3. SAFETY PRECAUTIONS" carefully before measurement.
5-12. CURRENT MEASUREMENT ( μA, mA / A )
WARNING
WARNING
10A AC/DC measurement is possible, but within 30 seconds. For continuous measurement, every 5 minutes interval is necessary for cooling down.
1 2
3
4 5
6
Insert black test lead to COM terminal. Insert red test lead to mA/
μ
A terminal for mA or μA measurement, or insert it to A terminal for A measurement. Set FUNCTION Switch to " " for A or mA measurement, or set it to " " for
μ
A
measurement. Press Select Key to select DC ( ) or AC ( ). Turn off the power of the circuit to be measured. Open the circuit after discharging the capacitors. Connect black test lead to (earth) side and connect red test lead to (positive) side of the circuit to measured.
NOTE NOTE
Connect the instrument IN SERIES to the circuit. Use Alligator Clips for dangerous current measurement.
Turn on the power of the circuit being measured and read the measurement value on LCD. Disconnect test leads from the circuit being measured after turn it off and discharge the all capacitors. After finishing the measurements, set FUNCTION Switch to "OFF".
7 8
9
fig-10
6-2. TRIGGER / CHANGING±TRIGGER Key
For example: In the case of fig-10
This function is available in Duty Cycle and Injection Pulse Width measurements. "" and "" sides of measuring trigger slope can be displayed by pressing ±TRIGGER Key. Default display is "".
Manual-range measurement is possible by pressing Range Key during auto-range measurement (" " disappears from LCD). To change the measurement range in manual-range, press Range Key.
To return to Auto-rangePress Range Key for more than 1 second. (" " lights up).
6-1. RANGE HOLDRange Key
6. FUNCTIONS
1
2 3
4
3.18ms is measuring in Injection Pulse Width measurement. "" sign shows that this value is "−" side of the measuring trigger slope. Press ±TRIGGER Key for 1 second or more. LCD display is changed into "" side of the trigger slope and "7.42ms" is displayed. LCD returns into "" value by pressing ± TRIGGER Key again for 1 second or more.
fig-11
7.42ms (70%)
3.18ms (30%)
5
6
For reference, the waveform of this measurement becomes like fig-11. In Duty Cycle terms, "" should be 30% and "" value should be 70% as shown in fig-11.
Press Key for more than 1 second to turn on the backlight. NOTE:Backlight turns off automatically after 32 seconds. During backlight turns on, press Key for more than 1 second again to turn off the backlight.
7-1. BATTERY AND FUSE REPLACEMENT
To avoid electrical shock, detach test leads from circuit when to replace battery and fuse. Set FUNCTION Switch to "OFF". Always use the specified fuse. Do not use this instrument shorting fuse holder or without using the fuse.
FUSE SPECIFICATIONFast-acting 11A/1000V (φ10×38mm)
Fast-acting 0.4A/1000V (φ6×32mm)
WARNING
7. MAINTENANCE
Replace the battery when "  " lights up on LCD. 1 2 3 4
5 6 7
NOTE
NOTE
Installed battery is for inspection purpose and might be exhausted earlier than the new battery. Remove the battery when the instrument is out of use for a long time. The exhausted battery might leak electrolyte and corrode the inside.
Finish the measurement and set FUNCTION Switch to "OFF". Remove the holster and loosen a screw on rear cover. Remove rear cover from the bottom side. Remove the exhausted battery and replace it into 2 pcs of new 1.5V R03 (AAA) batteries
in the correct polarity.
When replacing a fuse, replace a blown fuse into a new one. Fix rear cover onto the rear case from upper side fitting their hooks together. Tighten the screws on rear case and fix the holster.
fig-12
1.5V R03 (AAA)
Batteries (2 pcs)
Fuse 0.4A/1000V
Fuse 11A/1000V
Rear Cover
Check the battery connection, polarity, and capacity (" " lights up or not). Confirm that FUNCTION Switch is set to the correct position. Confirm that the body of this instrument and handle insulators of test leads have no cracks or any other damages. Check if any noise affects the instrument. This instrument is fully shielded against noise, but possibly to be affected by very strong noise.
Periodical check and calibration is necessary to make safety measurements and to maintain the specified accuracy. The recommended check and calibration term is once a year and after the repair service. This service is available at KAISE AUTHORIZED SERVICE AGENCY through your local dealer.
Repair service is available at KAISE AUTHORIZED SERVICE AGENCY through your local dealer. Pack the instrument securely with your name, address, telephone number and problem details, and ship prepaid to your local dealer.
7-2. PERIODICAL CHECK AND CALIBRATION
7-3. REPAIR
1 2 3
4
Check the following items before asking repair service.
KT-2021 is warranted in its entirety against any defects of material or workmanship under normal use and service within a period of one year from the date of purchase of the original purchaser. Warranty service is available at KAISE AUTHORIZED SERVICE AGENCY through your local dealer. Their obligation under this warranty is limited to repairing or replacing KT-2021 returned intact or in warrantable defect with proof of purchase and transport charges prepaid. KAISE AUTHORIZED DEALER and the manufacturer, KAISE CORPORATION, shall not be liable for any consequential damages, loss or otherwise. The foregoing warranty is exclusive and in lieu of all other warranties including any warranty of merchantability, whether expressed or implied. This warranty shall not apply to any instrument or other article of equipment which shall have been repaired or altered outside of KAISE AUTHORIZED SERVICE AGENCY, nor which have been subject to misuse, negligence, accident, incorrect repair by users, or any installation or use not in accordance with instructions provided by the manufacturer.
WARRANTY
70-1201-2022-1 1804
KAISE AUTHORIZED DEALER
422 Hayashinogo, Ueda City, Nagano Pref., 386-0156 Japan TEL : +81-268-35-1600 (REP.) / FAX : +81-268-35-1603 E-mail : sales@kaise.com http://www.kaise.com
Product specifications and appearance are subject to change without notice due to continual improvements.