KaiDeng WVC User Manual

Wireless 433/462MHz
WVC Modem
User Manual
2017/3 V3.0
Contents
1 Summarize
1.2 Application Fields and Range
1.3 Copyright statement
2 WVC Modem User Manual
2.1 System Comprehensive description
2.2 Equipment components
2.3 WVC Modem Installation
2.4 WVC-Modem Instructions
2.5 System communication control flow chart
2.6 Equipment reboot
2.7 Disconnect sequence
3 Operational environment & fault handling
3.1 Natural environment
3.2 Errors handling
4 Thank you
1
1
1
1
1
1
3
4
5
5
6
6
6
6
6
6
1
1.1 Background
1 Summarize
As a prof essional sola r, wind power generatio n system provi ders, with the strong resear ch and develop ment, design,
product ion capacity, we alwa ys will meet th e maximizatio n and diversifi cation demand of user a s our service s tandards.
From 21 c entury, solar, wind an d other renewa ble clean ener gy is applied more and more widely, b ut the existin g solar,
wind pow er generation system generally have the difficul t to monitor an d maintenance, new gen eration of
communi cation type PV power system came into being and solv e this kind of p roblem perfec t. WVC Modem is a
importa nt part of comm unication generation system. The success of res earch and deve lopment of WVC Modem ha ve
provide d a reliable re lay communication dat a support for c entralized an d round-the-c lock devices monitori ng
managem ent. And the u ser can through this manual to unders tanding the de tailed of WVC M odem’s use method an d
attenti ons.
1.2 Application Fields and Range
WVC Mo dem is a sp ecial dev ice for communi cation ty pe genera tion syst em and nee d to match up to comm unicatio n
Micro inverter and Power Monitoring Sys tem for us e. It hasn ’t compat ibility f or other c ompany pr oducts.
1.3 Copyright statement
WVC Mode m is research a nd development by us. have the owners hip and power o f interpretat ion of its Engl ish logo,
Chinese label and imag e identification , and r elated softwa re intellectu al property.
2.1 System Comprehensive description
2 WVC Modem User Manual
WVC Mode m is the import ant component of communication powe r generating s ystem. Accordi ng to the appli ed
charact eristics, we d esign a WVC Modem which can monitorin g and manage of 100 pcs micro i nverter. 100pc s micro
inverte r and one WVC Mo dem make a group. In the same group, mi cro inverters and WVC Modem m ust be install ed
inthesa me phase circuit ,WVC Modem’s standard i nterface is RS23 2,If there are no RS 232 interface on your computer
you need to b uy the USB To RS232 con nector then us e the USB port to c ommunicate dir ectly.
In the whole p ower syste m, WVC Modem system simp le structu re schemes like below: ( detailed i nsta llation ch art please see commu nication power generation syste m installation struc ture guide):
WV C
Mo dem
WV C
Mo dem
WV C
Mo dem
WV C
Mo dem
Communicational PV Micro Inverters Generating System Structure Chart
PV panels & Inverters array
Quantity of Inverters 100
PV panels & Inverters array
Quantity of Inverters 100
PV panels & Inverters array
Quantity of Inverters 100
PV panels & Inverters array
Quantity of Inverters 100
2
2. One RS232 serial connections
Signal lamps
Power light
Power line/plug
Signal line
3
1.WVC M odem unit.
2.2 Equipment components
WVC Mod em standrd c omponent s including:
4
Female contact of l unk
Connect to Modem se rial port
2. Con nect the s erial por t of the ma le contact of lunk to comp uter main c hassis’s seri al port an d tighten the screw on both e nds of the c onnectio ns, show l ikes below:
Male contact of lun k
Connect to compu ter main
chassis’s serial port
3. Con nect the p ower;
4. Fin ish insta llation o f WVC Mode m;
1. Con nect the s erial por t of the fe male contact of lunk to WV C Modem se rial port and tight en the scr ew on both ends of the co nnection s, show li kes below:
Wh en the micr o inverter s is less th an or equal to 100pcs i n g enerati on system, we only nee d t o instal l o ne WVC Mo de m. Th e instal lation i s v ery simp le, just need usi ng the seri al port t o connect t he WVC Mo dem and c om puter, th en plugg ed in po wer. Of course, the fir st pre mise is y our co mpute r needs a seria l port (If ther e are n o RS23 2 interf ace on your c omputer you ne ed to buy t he USB To R S232 conn ector the n use the U SB port to communic ate directly.). An d the deta ils insta llation like b elow:
2.3 WVC Modem Installation
WVC Mod em w ill sta rt t o w r ok afte r p o wer on . WV C Mo dem is a com mun ica tio n an d da ta t run king . T her e is no func t ion k e y s on t h e Mod e m, we j ust n e ed to k e ep i t c onti n uous p ower s uppl y. P a rts o f oper a t ion o r der w i ll autom atica lly comp let e by WVC Mo dem and Mon itori ng Syste m w ill manu ally or aut omati cal ly co mpl et e t he rest
The seque nce of devices sta rt and operation is the most im portant in Gener ation System, an d details of the seq uence please re fer to section 4.x o f the manual.
2.4 WVC-Modem Instructions
instruc tions. (Referr ing to Monitoring System Instructions)
2.5 System communication control flow chart
The devic es of the new commun icational PV generate sys tem is like an organ ic whole that each r elated closely , we have designe d a WVC Modem‐based communicati onal PV generate s ystem and reliable workin g process of data tr ansmission. And here is t he system commun ication control flow chart as follows:
SolarPanel
Solar
Panel
Micro
Inverte r
Solar
Panel
Micro
Inverte r
Solar
Panel
Micro
Inverte r
SolarPanel
Solar
Panel
Micro
Inverte r
Solar
Panel
Micro
Inverte r
Solar
Panel
Micro
Inverte r
WVC
Modem
Instructions
Auto- Data Colle ction
Instructions
System
Datebase
Chart OF
Analysis
433/462MHz433/462MHz
5
6
It is simpl e to reboot WVC Mode m:Turn WVC Modem p ower off, then wait for second s to restore power s upply;
2.6 Equipment reboot
Accordi ng to WVC Modem' ser ial port connection, plea se DO NOT disconne ct or install WVC Mo dem to keep the hardwar e safe when power on . Please refer to the followi ng steps to discon nect:
1. Discon nect WVC Modem pow er plug;
2.7 Disconnect sequence
First you need to disconnect
the power of Modem
2. Discon nect WVC Modem wit h serial port line;
3. Discon nect PC with seria l port line;
4. WVC Mode m disconnected c omplete;
3. Operational environment & fault handling
3.1 Natural environment
WVC Modem i s an ordinary comm unicational trucking de vice, and it would n ot work in good cond ition, or even be damaged i n a very bad environ ment. Please note that no hig h temperature, n o high humidity an d no ultra‐low tempera ture working env ironment. waterproof bo xes needed for out door working env ironment, no dir ect sunlight exposur e and no extremely c old environment without h eat preservati on devices.
3.2 Errors handling
How to d ea l wi th failing to connect devices and monit or in g system online?
There are rea sons about failure to connect as the following be low, please kind ly check:
1. Check th e device driver if s et up correctly. I f use USB TO RS232 it needs to set up the drivers corre ctly. If not, it will not w ork;
2. Check th e condition of WVC M odem and confirm the gird powe r is steady;
3. Check th e temperture of th e WVC‐Modem . If the tem perature is higher ,pleas e shutdown the pow er and restart a fter heat dissip ation;
4. All abov e checked and syst em online failure still exi sts, please cont act us and we will sup ply you the profess ional tsting to yo ur equipment.
How to d ea l wi th one WVC Mod em f ai li ng to communicate cor rectl y in norm al monitoring pro ce ssing?
WVC Modem i s design for 24‐hour w ork and long time with thousa nds times of testi ng. However, WVC M odem may not com municate corre ctly all the time in the bad condition below: hig h temperature, m oisture, signa l interfe rence of wireles s and other factors.When it occur to the bad situ ation, please cu t the modem power off and wait a fe w minutes and then c onnect the power, the probl em can be solved gen erally. Or call ou r local after‐ser vice branch for su pport and help after trying several times.
4. Thank you
Thanks fo r choosing our pro ducts and the service!Mee ting our custome rs' maximize nee ds is the final goal to p ursue. Thank you v ery much for readi ng this manual, and hope it wou ld be helpful to you r work and life!Th ank you!
Loading...